Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SC836

Download as pdf or txt
Download as pdf or txt
You are on page 1of 146

SC836 Chassis Series

SC836BE1C-R1K03B SC836BE2C-R1K03B
SC836BHA-R1K28B SC836BHE16-R1K28B
SC836BHE26-R1K28B SC836BE16-R1K28B
SC836BE26-R1K28B SC836BA-R1K28B
SC836BE16-R920B SC836BE26-R920B
SC836BA-R920B SC836TQ-R500B
SC836E16-R500B SC836E16-R1200B
SC836E26-R1200B SC836A-R1200B
SC836BE1C-R1K23B SC836TQ-R710B
SC836TQ-R800V / SC836TQ-R800B

USER’S MANUAL
Revision 2.2
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.

Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and
documentation, is the property of Supermicro and/or its licensors, and is supplied only under a
license. Any use or reproduction of this product is not allowed, except as expressly permitted by
the terms of said license.

IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,


SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
A n y
disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for
all claims will not exceed the price paid for the hardware product.

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”

WARNING: Handling of lead solder materials used in this


product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.

Manual Revision 2.2


Release Date: March 09, 2020

Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.

Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.

Copyright © 2020 by Super Micro Computer, Inc.


All rights reserved.
Printed in the United States of America
Preface

Preface

About this Manual


This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the chassis. Installation and
maintenance should be performed by experienced technicians only.
This document lists compatible parts available when this document was published.
Refer to the Supermicor web site for updates on supported parts and configurations.

Warnings
Special attention should be given to the following symbols used in this manual.

Warning! Indicates important information given to prevent equipment/


property damage or personal injury.

Warning! Indicates high voltage may be encountered when performing


a procedure.

iii
SC836 Chassis Manual

Contents

Contacting Supermicro ................................................................................................. vii


Chapter 1 Introduction
1-1 Overview.......................................................................................................... 1-1
1-2 Shipping List..................................................................................................... 1-2
1-3 Chassis Features............................................................................................. 1-2
Processor Support........................................................................................... 1-2
PCI Expansion Slots........................................................................................ 1-2
Cooling............................................................................................................. 1-2
Control Panel................................................................................................... 1-2
1-4 Returning Merchandise for Service................................................................. 1-3
1-5 Where to get Replacement Components......................................................... 1-3
Chapter 2 Standardized Warning Statements for AC Systems
About Standardized Warning Statements........................................................ 2-1
Warning Definition............................................................................................ 2-1
Installation Instructions..................................................................................... 2-4
Circuit Breaker................................................................................................. 2-5
Power Disconnection Warning......................................................................... 2-6
Equipment Installation...................................................................................... 2-8
Restricted Area................................................................................................. 2-9
Battery Handling............................................................................................. 2-10
Redundant Power Supplies .......................................................................... 2-12
Backplane Voltage......................................................................................... 2-13
Comply with Local and National Electrical Codes......................................... 2-14
Product Disposal............................................................................................ 2-15
Hot Swap Fan Warning.................................................................................. 2-16
Power Cable and AC Adapter ....................................................................... 2-18
Chapter 3 System Interface
3-1 Overview.......................................................................................................... 3-1
3-2 Control Panel Buttons...................................................................................... 3-2
Power............................................................................................................... 3-2
Reset................................................................................................................ 3-2
3-3 Control Panel LEDs......................................................................................... 3-2
Power............................................................................................................... 3-2
HDD.................................................................................................................. 3-2
NIC2................................................................................................................. 3-3

iv
Preface

NIC1................................................................................................................. 3-3
Information LED............................................................................................... 3-3
Power Fail........................................................................................................ 3-3
Overheating...................................................................................................... 3-4
Overheat Temperature Setting.................................................................... 3-4
Responses................................................................................................... 3-4
3-4 Drive Carrier LEDs........................................................................................... 3-4
3-5 Power Supply LEDs......................................................................................... 3-5
Chapter 4 Chassis Setup and Maintenance
4-1 Overview.......................................................................................................... 4-1
4-2 Removing Power from the System.................................................................. 4-2
4-3 Removing the Chassis Cover.......................................................................... 4-3
4-4 Installing Hard Drives....................................................................................... 4-4
Primary Hot-Swap Drives................................................................................. 4-4
Optional HDDs in the Rear of the Chassis...................................................... 4-7
4-5 Expansion Cards ............................................................................................. 4-9
4-6 Installing the Air Shroud................................................................................. 4-10
4-7 System Fans...................................................................................................4-11
Checking the Server Air Flow........................................................................ 4-12
4-8 Power Supply ................................................................................................ 4-13
Chapter 5 Rack Installation
5-1 Unpacking the System..................................................................................... 5-1
5-2 Preparing for Setup.......................................................................................... 5-1
Choosing a Setup Location.............................................................................. 5-1
5-3 Warnings and Precautions............................................................................... 5-2
Rack Precautions............................................................................................. 5-2
General Server Precautions............................................................................. 5-2
Rack Mounting Considerations........................................................................ 5-3
Ambient Operating Temperature................................................................. 5-3
Sufficient Airflow.......................................................................................... 5-3
Circuit Overloading...................................................................................... 5-3
Reliable Ground.......................................................................................... 5-3
5-4 Installing the System into a Rack ................................................................... 5-4
Identifying the Sections of the Rack Rails....................................................... 5-4
Releasing the Inner Rail.................................................................................. 5-5
Installing the Inner Rails on the Chassis......................................................... 5-6
Installing the Outer Rails onto the Rack.......................................................... 5-7
Sliding the Chassis onto the Rack Rails.......................................................... 5-8

v
SC836 Chassis Manual

Appendix A Chassis Cables


Appendix B SC836 Power Supply Specifications
Appendix C Backplane Specifications
C-1 Overview..........................................................................................................C-1
C-2 Safety Guidelines.............................................................................................C-2
C-3 BPN-SAS-836A Backplane..............................................................................C-3
C-4 BPN-SAS-836TQ Backplane.........................................................................C-10
C-5 BPN-SAS2-836EL Backplane and SAS2 JBOD Configuration.....................C-19
C-6 BPN-SAS3-836EL Backplane and SAS3 JBOD Configuration.....................C-43
Appendix D SC836B Added Features
Appendix E CSE-PTJBOD-CB3 Control Board

vi
Preface

Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com

Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Web Site: www.supermicro.nl

Asia-Pacific
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Web Site: www.supermicro.com.tw

vii
SC836 Chassis Manual

Notes

viii
Chapter 1: Introduction

Chapter 1

Introduction

1-1 Overview
Supermicro's SC836 storage chassis supports up to sixteen hot-swappable 3.5"
SAS/SATA hard drives, the industry's highest storage density for a 3U system. The
SC836 includes 100% cooling redundancy and high efficiency (1+1) redundant
power supplies with PM BUS functionality for enhanced power management. The
chassis is optimized for the next-generation dual-processor Intel Xeon (5500 series)
and AMD Opteron platforms. Direct attached HDD backplane (TQ version), multilane
backplane (A version) and expander backplane (E1, E2 versions) are available
for application-specific solution optimization. Heavy duty palletized packaging is
available to ensure secure system reliability during shipping. Tool-less, roller rail
designs for easy installation and maintenance are standard with each system.
SC836 Chassis Series

Model HDD PCI Slots Power Supply

SC836BE1C-R1K03B 16x 3.5" SAS


7x FF 1000W (Redundant, Titanium)
SC836BE2C-R1K03B 2x 2.5" SAS

SC836BHA-R1K28B
SC836BHE16-R1K28B
SC836BHE26-R1K28B 16x 3.5" SAS
7x FF 1280W (Redundant, Platinum)
SC836BE16-R1K28B (opt) 2x 2.5" SAS
SC836BE26-R1K28B
SC836BA-R1K28B
SC836BE16-R920B
16x 3.5" SAS
SC836BE26-R920B (opt) 2x 2.5" SAS
7x FF 920W (Redundant, Platinum)
SC836BA-R920B
SC836TQ-R500B 16x 3.5" SAS
7x FF 500W (Redundant, Platinum)
SC836E16-R500B 2x 2.5" fixed

SC836E16-R1200B
16x 3.5" SAS
SC836E26-R1200B 3x 2.5" fixed
7x FF 1200W (Redundant, Gold)
SC836A-R1200B
SC836TQ-R800V /
16x 3.5" SAS 7x FF 800W (Redundant)
SC836TQ-R800B
SC836TQ-R710B 16x 3.5" SAS 7x FF 710W DC (Redundant)
16x 3.5" SAS
SC836BE1C-R1K23B (opt) 2x 2.5" SAS
7x FF 1200W (Redundant, Titanium)

1-1
SC836 Chassis Manual

1-2 Shipping List


Visit the Supermicro web site for the latest shipping lists and part numbers for
your particular chassis model at www.supermicro.com.

1-3 Chassis Features


The SC836 3U high-performance chassis includes the following features:

Processor Support
The chassis supports dual Dual-core Xeon processors and serverboards up to 13.7"
x 13", E-ATX and ATX. Refer to the motherboard specifications pages on our web
site for updates on supported processors for this chassis.

Drives
The chassis supports up to sixteen 3.5" hot-swap SAS or SATA drives with SES2.
With RAID, these drives may be replaced without powering down the server. Some
models also support two hot-swap 2.5" drives in the rear, or two or three internal
fixed 2.5" drives. Supporting backplanes are described in the the appendices.
The chassis supports one slim DVD drive (optional).

PCI Expansion Slots


Each version of the chassis includes seven full height, full width expansion slots.

Cooling
Three hot-plug 80mm fans plus two 80mm exhaust fans provide 100% cooling
redundancy, aided by an adjustable air shroud. The 4-pin fans are controlled
though IPMI.

Control Panel
The front control panel includes system status LED indicators and power switches.

1-2
Chapter 1: Introduction

1-4 Returning Merchandise for Service


A receipt or copy of your invoice marked with the date of purchase is required before
any warranty service will be rendered. You can obtain service by calling your vendor
for a Returned Merchandise Authorization (RMA) number. When returning to the
manufacturer, the RMA number should be prominently displayed on the outside of
the shipping carton, and mailed prepaid or hand-carried. Shipping and handling
charges will be applied for all orders that must be mailed when service is complete.
For faster service, RMA authorizations may be requested online (http://www.
supermicro.com/support/rma/).
Whenever possible, repack the chassis in the original Supermicro carton, using the
original packaging material. If these are no longer available, be sure to pack the
chassis securely, using packaging material to surround the chassis so that it does
not shift within the carton and become damaged during shipping.
This warranty only covers normal consumer use and does not cover damages
incurred in shipping or from failure due to the alteration, misuse, abuse or improper
maintenance of products.
During the warranty period, contact your distributor first for any product problems.

1-5 Where to get Replacement Components


Although not frequently, you may need replacement parts for your system. To
ensure the highest level of professional service and technical support, we strongly
recommend purchasing exclusively from our Supermicro Authorized Distributors/
System Integrators/Resellers. A list of Supermicro Authorized Distributors/System
Integrators/Resellers can be found at: www.supermicro.com. Click the Where to
Buy link

1-3
SC836 Chassis Manual

Notes

1-4
Chapter 2: Warning Statements for AC Systems

Chapter 2

Standardized Warning Statements for AC Systems

About Standardized Warning Statements


The following statements are industry standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions
or experience difficulty, contact Supermicro's Technical Support department
for assistance. Only certified technicians should attempt to install or configure
components.
Read this appendix in its entirety before installing or configuring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/
about/policies/safety_information.cfm.

Warning Definition

Warning!
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.

警告の定義
この警告サインは危険を意味します。
人身事故につながる可能性がありますので、いずれの機器でも動作させる前に、
電気回路に含まれる危険性に注意して、標準的な事故防止策に精通して下さい。

此警告符号代表危险。
您正处于可能受到严重伤害的工作环境中。在您使用设备开始工作之前,必须充分
意识到触电的危险,并熟练掌握防止事故发生的标准工作程序。请根据每项警告结
尾的声明号码找到此设备的安全性警告说明的翻译文本。

此警告符號代表危險。
您正處於可能身體可能會受損傷的工作環境中。在您使用任何設備之前,請注意觸
電的危險,並且要熟悉預防事故發生的標準工作程序。請依照每一注意事項後的號
碼找到相關的翻譯說明內容。

2-1
SC836 Chassis Manual

Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den
Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung
vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.

INSTRUCCIONES IMPORTANTES DE SEGURIDAD


Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al
final de cada advertencia encontrará el número que le ayudará a encontrar el texto
traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.

IMPORTANTES INFORMATIONS DE SÉCURITÉ


Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées pour
éviter les accidents. Pour prendre connaissance des traductions des avertissements
figurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS.

‫תקנון הצהרות אזהרה‬

‫ על מנת להזהיר את המשתמש מפני חבלה‬,‫הצהרות הבאות הן אזהרות על פי תקני התעשייה‬


‫ יש ליצור קשר עם מחלקת תמיכה‬,‫ במידה ויש שאלות או היתקלות בבעיה כלשהי‬.‫פיזית אפשרית‬
.‫ טכנאים מוסמכים בלבד רשאים להתקין או להגדיר את הרכיבים‬.‫טכנית של סופרמיקרו‬

.‫יש לקרוא את הנספח במלואו לפני התקנת או הגדרת הרכיבים במארזי סופרמיקרו‬

2-2
Chapter 2: Warning Statements for AC Systems

. ‫تحذٌز!هذا الزهز ٌعًٌ خطز اًك فً حالة ٌوكي أى تتسبب فً اصابة جسذٌة‬
‫كي على علن بالوخاطز الٌاجوة عي الذوائز‬،‫قبل أى تعول على أي هعذات‬
‫الكهزبائٍة‬
‫وكي على دراٌة بالووارسات الىقائٍة لوٌع وقىع أي حىادث‬
‫استخذم رقن البٍاى الوٌصىص فً ًهاٌة كل تحذٌز للعثىر تزجوتها‬

안전을 위한 주의사항

경고!

이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수


있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와
관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준
작업절차를 준수해 주시기 바랍니다.

해당 번역문을 찾기 위해 각 경고의 마지막 부분에 제공된 경고문 번호를


참조하십시오

BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken,
dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico's
en dient u op de hoogte te zijn van de standaard procedures om ongelukken te
voorkomen. Gebruik de nummers aan het eind van elke waarschuwing om deze te
herleiden naar de desbetreffende locatie.
BEWAAR DEZE INSTRUCTIES

2-3
SC836 Chassis Manual

Installation Instructions

Warning!
Read the installation instructions before connecting the system to the power source.
設置手順書

システムを電源に接続する前に、設置手順書をお読み下さい。

警告
将此系统连接电源前,请先阅读安装说明。

警告
將系統與電源連接前,請先閱讀安裝說明。
Warnung
Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen
lesen.

¡Advertencia!
Lea las instrucciones de instalación antes de conectar el sistema a la red de
alimentación.

Attention
Avant de brancher le système sur la source d'alimentation, consulter les directives
d'installation.

.‫יש לקרוא את הוראות התקנה לפני חיבור המערכת למקור מתח‬

‫اقر إرشادات التركيب قبل توصيل النظام إلى مصدر للطاقة‬

시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오.

Waarschuwing
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron
aansluit.

2-4
Chapter 2: Warning Statements for AC Systems

Circuit Breaker

Warning!
This product relies on the building's installation for short-circuit (overcurrent)
protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
サーキット・ブレーカー

この製品は、短絡(過電流)保護装置がある建物での設置を前提としています。

保護装置の定格が250 V、20 Aを超えないことを確認下さい。

警告
此产品的短路(过载电流)保护由建筑物的供电系统提供,确保短路保护设备的额定电
流不大于250V,20A。

警告
此產品的短路(過載電流)保護由建築物的供電系統提供,確保短路保護設備的額定電
流不大於250V,20A。

Warnung
Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss-
bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der
Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt.

¡Advertencia!
Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes)
del edificio. Asegúrese de que el dispositivo de protección no sea superior a: 250
V, 20 A.

Attention
Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit
dépend de l'installation électrique du local. Vérifiez que le courant nominal du
dispositif de protection n'est pas supérieur à :250 V, 20 A.

‫ יש לוודא כי‬.‫מוצר זה מסתמך על הגנה המותקנת במבנים למניעת קצר חשמלי‬


250 V, 20 A-‫המכשיר המגן מפני הקצר החשמלי הוא לא יותר מ‬

‫هذا المنتج يعتمد على معداث الحمايت مه الدوائرالقصيرة التي تم تثبيتها في‬
‫المبنى‬
20A, 250V :‫تأكد من أن تقييم الجهاز الوقائي ليس أكثر من‬

2-5
SC836 Chassis Manual

경고!

이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에


의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지
않도록 해야 합니다.

Waarschuwing
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van
uw electrische installatie. Controleer of het beveiligde aparaat niet groter
gedimensioneerd is dan 220V, 20A.

Power Disconnection Warning

Warning!
The system must be disconnected from all sources of power and the power cord
removed from the power supply module(s) before accessing the chassis interior to
install or remove system components.

電源切断の警告
システムコンポーネントの取り付けまたは取り外しのために、
シャーシー内部にアクセス
するには、
システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り
外す必要があります。

警告
在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。

警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
Warnung
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel
getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es
auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder
zu entfernen.

2-6
Chapter 2: Warning Statements for AC Systems

¡Advertencia!
El sistema debe ser disconnected de todas las fuentes de energía y del cable
eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso
el interior del chasis para instalar o para quitar componentes de sistema.

Attention
Le système doit être débranché de toutes les sources de puissance ainsi que de
son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour
installer ou enlever des composants de systéme.
‫אזהרה מפני ניתוק חשמלי‬
!‫אזהרה‬
‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬
.‫לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬

‫يجب فصم اننظاو من جميع مصادر انطاقت وإزانت سهك انكهرباء من وحدة امداد‬
‫انطاقت قبم‬
‫انىصىل إنى انمناطق انداخهيت نههيكم نتثبيج أو إزانت مكىناث الجهاز‬

경고!

시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에


반드시 전원 공급장치로부터 연결되어있는 모든 전원과 전기코드를 분리해주어야
합니다.

Waarschuwing
Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren
of verwijderen van systeem onderdelen, dient u alle spanningsbronnen en alle
stroomkabels aangesloten op de voeding(en) van de behuizing te verwijderen

2-7
SC836 Chassis Manual

Equipment Installation

Warning!
Only trained and qualified personnel should be allowed to install, replace, or service
this equipment.

機器の設置
トレーニングを受け認定された人だけがこの装置の設置、交換、
またはサービスを許可
されています。

警告
只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。

警告
只有經過受訓且具資格人員才可安裝、更換與維修此設備。

Warnung
Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem,
qualifiziertem Personal gestattet werden.

¡Advertencia!
Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo.

Attention
Il est vivement recommandé de confier l'installation, le remplacement et la
maintenance de ces équipements à des personnels qualifiés et expérimentés.

!‫אזהרה‬
.‫ להחליף את הציוד או לתת שירות עבור הציוד‬,‫צוות מוסמך בלבד רשאי להתקין‬

‫يجب أن يسمح فقط للمىظفيه المؤهليه والمدربيه لتزكيب واستبدال أو خدمة هذا الجهاس‬

경고!

훈련을 받고 공인된 기술자만이 이 장비의 설치, 교체 또는 서비스를 수행할 수


있습니다.

2-8
Chapter 2: Warning Statements for AC Systems

Waarschuwing
Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door
geschoold en gekwalificeerd personeel.

Restricted Area

Warning!
This unit is intended for installation in restricted access areas. A restricted access
area can be accessed only through the use of a special tool, lock and key, or other
means of security. (This warning does not apply to workstations).

アクセス制限区域
このユニットは、
アクセス制限区域に設置されることを想定しています。
アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いての
み出入りが可能です。

警告
此部件应安装在限制进出的场所,限制进出的场所指只能通过使用特殊工具、锁和
钥匙或其它安全手段进出的场所。

警告
此裝置僅限安裝於進出管制區域,進出管制區域係指僅能以特殊工具、鎖頭及鑰匙
或其他安全方式才能進入的區域。

Warnung
Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen.
Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und
Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich.

¡Advertencia!
Esta unidad ha sido diseñada para instalación en áreas de acceso restringido.
Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una
herramienta especial, cerradura con llave u otro medio de seguridad.

Attention
Cet appareil doit être installée dans des zones d'accès réservés. L'accès à une
zone d'accès réservé n'est possible qu'en utilisant un outil spécial, un mécanisme
de verrouillage et une clé, ou tout autre moyen de sécurité.

2-9
SC836 Chassis Manual

‫אזור עם גישה מוגבלת‬

!‫אזהרה‬
‫ הגישה ניתנת בעזרת‬.‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה‬
.)'‫ מנעול וכד‬,‫כלי אבטחה בלבד (מפתח‬

. ‫تم تخصيص هذه انىحذة نتركُبها فٍ مناطق محظورة‬


،‫َمكن انىصىل إنً منطقت محظورة فقط من خالل استخذاو أداة خاصت‬
‫قفم ومفتاح أو أٌ وسُهت أخري نالمألما‬
경고!

이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다. 특수도구, 잠금 장치 및


키, 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다.

Waarschuwing
Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang.
Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te
maken van speciaal gereedschap, slot en sleutel of andere veiligheidsmaatregelen.

Battery Handling

Warning!
There is the danger of explosion if the battery is replaced incorrectly. Replace the
battery only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer's instructions

電池の取り扱い

電池交換が正しく行われなかった場合、破裂の危険性があります。交換する電池はメー
カーが推奨する型、または同等のものを使用下さい。使用済電池は製造元の指示に従
って処分して下さい。
警告
电池更换不当会有爆炸危险。请只使用同类电池或制造商推荐的功能相当的电池更
换原有电池。请按制造商的说明处理废旧电池。

警告
電池更換不當會有爆炸危險。請使用製造商建議之相同或功能相當的電池更換原有
電池。請按照製造商的說明指示處理廢棄舊電池。

2-10
Chapter 2: Warning Statements for AC Systems

Warnung
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die
Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp.
Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.

Attention
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer
que par une pile de type semblable ou équivalent, recommandée par le fabricant.
Jeter les piles usagées conformément aux instructions du fabricant.

¡Advertencia!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta.
Reemplazar la batería exclusivamente con el mismo tipo o el equivalente
recomendado por el fabricante. Desechar las baterías gastadas según las
instrucciones del fabricante.

!‫אזהרה‬
‫ יש להחליף‬.‫קיימת סכנת פיצוץ של הסוללה במידה והוחלפה בדרך לא תקינה‬
.‫את הסוללה בסוג התואם מחברת יצרן מומלצת‬
.‫סילוק הסוללות המשומשות יש לבצע לפי הוראות היצרן‬

‫هناك خطر من انفجار في حالة اسحبذال البطارية بطريقة غير صحيحة فعليل‬
‫اسحبذال البطارية‬
‫فقط بنفس النىع أو ما يعادلها مما أوصث به الشرمة المصنعة‬
‫جخلص من البطاريات المسحعملة وفقا لحعليمات الشرمة الصانعة‬

경고!
배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와
동일하거나 제조사에서 권장하는 동등한 종류의 배터리로만 교체해야 합니다.
제조사의 안내에 따라 사용된 배터리를 처리하여 주십시오.

Waarschuwing
Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt. Vervang de
batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen
wordt. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd
te worden.

2-11
SC836 Chassis Manual

Redundant Power Supplies

Warning!
This unit might have more than one power supply connection. All connections must
be removed to de-energize the unit.

冗長電源装置
このユニットは複数の電源装置が接続されている場合があります。
ユニットの電源を切るためには、すべての接続を取り外さなければなりません。

警告
此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。

警告
此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。

Warnung
Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass
der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.

¡Advertencia!
Puede que esta unidad tenga más de una conexión para fuentes de alimentación.
Para cortar por completo el suministro de energía, deben desconectarse todas las
conexiones.

Attention
Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute
tension et tout courant électrique de l'unité, toutes les connexions d'alimentation
doivent être débranchées.

‫אם קיים יותר מספק אחד‬

!‫אזהרה‬
‫ יש להסיר את כל החיבורים על מנת לרוקן‬.‫ליחדה יש יותר מחיבור אחד של ספק‬
.‫את היחידה‬

2-12
Chapter 2: Warning Statements for AC Systems

.‫قد يكون لهذا الجهاز عدة اتصاالت بوحدات امداد الطاقة‬


‫يجب إزالة كافة االتصاالت لعسل الوحدة عن الكهرباء‬
경고!

이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에


전원을 차단하기 위해서는 모든 연결 단자를 제거해야만 합니다.

Waarschuwing
Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle
aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken.

Backplane Voltage

Warning!
Hazardous voltage or energy is present on the backplane when the system is
operating. Use caution when servicing.

バックプレーンの電圧
システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。
修理する際には注意ください。

警告
当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。

警告
當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。

Warnung
Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche
Spannungen oder Energien auf. Vorsicht bei der Wartung.

¡Advertencia!
Cuando el sistema está en funcionamiento, el voltaje del plano trasero es peligroso.
Tenga cuidado cuando lo revise.

Attention
Lorsque le système est en fonctionnement, des tensions électriques circulent sur
le fond de panier. Prendre des précautions lors de la maintenance.

2-13
SC836 Chassis Manual

‫מתח בפנל האחורי‬

!‫אזהרה‬
‫ יש להיזהר במהלך‬.‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת‬
.‫העבודה‬

‫هناك خطز مه التيار الكهزبائي أوالطاقة المىجىدة على اللىحة‬


‫عندما يكىن النظام يعمل كه حذرا عند خدمة هذا الجهاس‬
경고!

시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생


합니다. 서비스 작업 시 주의하십시오.

Waarschuwing
Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het
systeem in gebruik is. Voorzichtigheid is geboden tijdens het onderhoud.

Comply with Local and National Electrical Codes

Warning!
Installation of the equipment must comply with local and national electrical codes.

地方および国の電気規格に準拠
機器の取り付けはその地方および国の電気規格に準拠する必要があります。

警告
设备安装必须符合本地与本国电气法规。
警告
設備安裝必須符合本地與本國電氣法規。

Warnung
Die Installation der Geräte muss den Sicherheitsstandards entsprechen.

¡Advertencia!
La instalacion del equipo debe cumplir con las normas de electricidad locales y
nacionales.

2-14
Chapter 2: Warning Statements for AC Systems

Attention
L'équipement doit être installé conformément aux normes électriques nationales
et locales.

‫תיאום חוקי החשמל הארצי‬

!‫אזהרה‬
.‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬

‫تركيب المعدات الكهربائية يجب أن يمتثل للقىاويه المحلية والىطىية المتعلقة‬


‫بالكهرباء‬
경고!

현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다.

Waarschuwing
Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale
elektriciteitsvoorschriften.

Product Disposal

Warning!
Ultimate disposal of this product should be handled according to all national laws
and regulations.

製品の廃棄

この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要が
あります。

警告
本产品的废弃处理应根据所有国家的法律和规章进行。

警告
本產品的廢棄處理應根據所有國家的法律和規章進行。

Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen
des Landes erfolgen.

2-15
SC836 Chassis Manual

¡Advertencia!
Al deshacerse por completo de este producto debe seguir todas las leyes y
reglamentos nacionales.

Attention
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des
lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de
l'organisme compétent.

‫סילוק המוצר‬

!‫אזהרה‬
.‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬

‫عند التخلص النهائي من هذا المنتج ينبغي التعامل معه وفقا لجميع القىانين واللىائح الىطنية‬

경고!

이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다.

Waarschuwing
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming
met alle nationale wetten en reglementen.

Hot Swap Fan Warning

Warning!
The fans might still be turning when you remove the fan assembly from the chassis.
Keep fingers, screwdrivers, and other objects away from the openings in the fan
assembly's housing.

ファン・ホットスワップの警告

シャーシから冷却ファン装置を取り外した際、ファンがまだ回転している可能性がありま
す。ファンの開口部に、指、
ドライバー、およびその他のものを近づけないで下さい。

警告
当您从机架移除风扇装置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他
物品太靠近风扇

2-16
Chapter 2: Warning Statements for AC Systems

警告
當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他
物品太靠近風扇。

Warnung
Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis
genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände
von den Öffnungen des Lüftergehäuses entfernt.

¡Advertencia!
Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador
del chasis. Mandtenga los dedos, los destornilladores y todos los objetos lejos de
las aberturas del ventilador

Attention
Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez
le bloc ventilateur du châssis. Prenez garde à ce que doigts, tournevis et autres
objets soient éloignés du logement du bloc ventilateur.

!‫אזהרה‬
‫ יש‬.‫ יתכן והמאווררים עדיין עובדים‬,‫כאשר מסירים את חלקי המאוורר מהמארז‬
‫להרחיק למרחק בטוח את האצבעות וכלי עבודה שונים מהפתחים בתוך המאוורר‬

‫مه انممكه أن انمراوح ال تسال تدورعند إزانة كتهة انمروحة مه انهيكم يجب إبقاء‬
‫األصابع ومفكات انبراغي‬
.‫وغيرها مه األشياء بعيدا عه انفتحات في كتهة انمروحة‬

경고!

섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬


조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이
가까이 하지 않도록 배치해 주십시오.

Waarschuwing
Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het
ventilatorsamenstel uit het chassis. Houd uw vingers, schroevendraaiers
en eventuele andere voorwerpen uit de buurt van de openingen in de
ventilatorbehuizing.

2-17
SC836 Chassis Manual

Power Cable and AC Adapter

Warning!
When installing the product, use the provided or designated connection cables,
power cables and AC adaptors. Using any other cables and adaptors could cause
a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the
use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any
other electrical devices than products designated by Supermicro only.

電源コードとACアダプター

製品を設置する場合、提供または指定された接続ケーブル、電源コードとACアダプター
を使用下さい。他のケーブルやアダプタを使用すると故障や火災の原因になることがあ
ります。電気用品安全法は、ULまたはCSA認定のケーブル(UL/CSEマークがコードに表
記)を Supermicroが指定する製品以外に使用することを禁止しています。

警告
安装此产品时,请使用本身提供的或指定的连接线,电源线和电源适配器.使用其它线
材或适配器可能会引起故障或火灾。除了Supermicro所指定的产品,电气用品和材
料安全法律规定禁止使用未经UL或CSA认证的线材。(线材上会显示UL/CSA符号)。

警告
安裝此產品時,請使用本身提供的或指定的連接線,電源線和電源適配器.使用其它線
材或適配器可能會引起故障或火災。除了Supermicro所指定的產品,電氣用品和材
料安全法律規定禁止使用未經UL或CSA認證的線材。(線材上會顯示UL/CSA符號)。

Warnung
Bei der Installation des Produkts, die zur Verfügung gestellten oder benannt
Anschlusskabel, Stromkabel und Netzteile. Verwendung anderer Kabel und Adapter
kann zu einer Fehlfunktion oder ein Brand entstehen. Elektrische Geräte und
Material Safety Law verbietet die Verwendung von UL-oder CSA-zertifizierte Kabel,
UL oder CSA auf der Code für alle anderen elektrischen Geräte als Produkte von
Supermicro nur bezeichnet gezeigt haben.

¡Advertencia!
Al instalar el producto, utilice los cables de conexión previstos o designados, los
cables y adaptadores de CA. La utilización de otros cables y adaptadores podría
ocasionar un mal funcionamiento o un incendio. Aparatos Eléctricos y la Ley de
Seguridad del Material prohíbe el uso de UL o CSA cables certificados que tienen
UL o CSA se muestra en el código de otros dispositivos eléctricos que los productos
designados por Supermicro solamente.

2-18
Chapter 2: Warning Statements for AC Systems

Attention
Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné.
L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement
ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit
l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code
pour tous les autres appareils électriques que les produits désignés par Supermicro
seulement.

AC ‫חשמליים ומתאמי‬

!‫אזהרה‬
‫ אשר‬AC ‫ ספקים ומתאמים‬,‫ יש להשתמש בכבלים‬,‫כאשר מתקינים את המוצר‬
‫ שימוש בכל כבל או מתאם אחר יכול לגרום לתקלה או‬.‫נועדו וסופקו לשם כך‬
‫ קיים איסור‬,‫ על פי חוקי שימוש במכשירי חשמל וחוקי בטיחות‬.‫קצר חשמלי‬
‫ (כשאר מופיע עליהם קוד של‬CSA -‫ או ב‬UL -‫להשתמש בכבלים המוסמכים ב‬
.‫) עבור כל מוצר חשמלי אחר שלא צוין על ידי סופרקמיקרו בלבד‬UL/CSA

‫والكابالث الكهربائيت‬،‫عىذ تركيب الجهاز يجب استخذام كابالث التىصيل‬


‫ومحىالث التيار المتردد‬
.‫ أن استخذام أي كابالث ومحىالث أخري يتسبب في حذوث عطل أو حريق‬. ‫التي‬
‫تم تىفيرها لك مع المىتج‬
UL ‫ أو‬CSA ‫األجهسة الكهربائيت ومىاد قاوىن السالمت يحظر استخذام الكابالث‬
‫معتمذة مه قبل‬
Supermicro ‫ألي أجهسة كهربائيت أخري غير المىتجاث المعيىت مه قبل‬
(UL/CSA ‫)التي تحمل عالمت‬
경고!

제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블, AC어댑터를


사용해야 합니다. 그 밖의 다른 케이블들이나 어댑터들은 고장 또는 화재의 원인이
될 수 있습니다. 전기용품안전법 (Electrical Appliance and Material Safety
Law)은 슈퍼마이크로에서 지정한 제품들 외에는 그 밖의 다른 전기 장치들을
위한 UL또는 CSA에서 인증한 케이블(전선 위에 UL/CSA가 표시)들의 사용을
금지합니다.

Waarschuwing
Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels,
stroomkabels en adapters. Het gebruik van andere kabels en adapters kan leiden
tot een storing of een brand. Elektrisch apparaat en veiligheidsinformatiebladen wet
verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op
de code voor andere elektrische apparaten dan de producten die door Supermicro
alleen.

2-19
SC836 Chassis Manual

Notes

2-20
Chapter 3: System Interface

Chapter 3

System Interface

3-1 Overview
The server includes a control panel on the front that houses power buttons and
status monitoring lights. The externally accessible hard drives display status lights.
The power supply displays status lights visible from the back of the chassis.

Figure 3-1. Front Control Panel

3-1
SC836 Chassis Manual

3-2 Control Panel Buttons


The chassis includes two push-buttons that control power to the system.

Power
The main power switch is used to apply or remove power from the power supply
to the server system. Turning off system power with this button removes the main
power but keeps standby power supplied to the system. Therefore, you must unplug
system before servicing.

Reset
The reset button is used to reboot the system.

3-3 Control Panel LEDs


There are six LEDs that provide status information about the system.

Power
Indicates power is being supplied to the system power supply units. This LED should
normally be illuminated when the system is operating.

HDD
Indicates activity on the hard drive when flashing.

3-2
Chapter 3: System Interface

NIC2
Indicates network activity on GLAN2 when flashing.

NIC1
Indicates network activity on GLAN1 when flashing.

Information LED
Alerts operator of several states, as noted in the table below.

Information LED
Status Description
An overheat condition has occured.
Continuously on and red
(This may be caused by cable congestion.)
Blinking red (1Hz) Fan failure, check for an inoperative fan.
Blinking red (0.25Hz) Power failure, check for a non-operational power supply.
Local UID has been activated. Use this function to locate
Solid blue
the server in a rack mount environment.
Remote UID is on. Use this function to identify the
Blinking blue
server from a remote location.

Power Fail
Indicates a power supply has failed.

3-3
SC836 Chassis Manual

Overheating
There are several possible responses if the system overheats.

Overheat Temperature Setting


Some backplanes allow the overheat temperature to be set at 45, 50, or 55 by
changing a jumper setting. For more information, consult the backplane user manual
at www.supermicro.com. (Click Support, then the Manuals link.)

Responses
If the server overheats:

1. Use the LEDs to determine the nature of the overheating condition.

2. Confirm that the chassis covers are installed properly.

3. Check the routing of the cables and make sure all fans are present and operating
normally.

4. Verify that the heatsinks are installed properly.

3-4 Drive Carrier LEDs


The chassis includes externally accessible SAS/SATA drives. Each drive carrier
displays two status LEDs on the front of the carrier.

LED Color Blinking Pattern Behavior for Device


Activity LED Blue Solid On SAS drive installed
Blue Blinking I/O activity
Status LED Red Solid On Failed drive for SAS/SATA/NVMe
with RSTe support
Red Blinking at 1 Hz Rebuild drive for SAS/SATA with
RSTe support
Red Blinking with two Hot spare for SAS/SATA with
blinks and one stop RSTe support
at 1 Hz
Red On for five Power on for SAS/SATA with
seconds, then off RSTe support
Red Blinking at 4 Hz Identify drive for SAS/SATA with
RSTe support

3-4
Chapter 3: System Interface

3-5 Power Supply LEDs


On the rear of the power supply module, an LED displays the status.
• Solid Green: When illuminated, indicates that the power supply is on.

• Solid Amber: When illuminated, indicates the power supply is plugged in and
turned off, or the system is off but in an abnormal state.

• Blinking Amber: When blinking, this system power supply temperature has
reached 63C. The system will automatically power-down when the power supply
temperature reaches 70C and restart when the power supply temperature goes
below 60C.

3-5
SC836 Chassis Manual

Notes

3-6
Chapter 4: Chassis Setup and Maintenance

Chapter 4

Chassis Setup and Maintenance

4-1 Overview
This chapter covers the steps required to install components and perform
maintenance on the chassis. The only tool required is a Phillips screwdriver.
Review the warnings and precautions listed in the manual before setting up or
servicing this chassis. These include information in Chapter 2: System Safety and
the warning/precautions listed in the setup instructions.

Control Panel

Primary Hot-Swap HDDs (16)

Power Supply Modules

Supports Two 2.5" HDDs


with optional kit
(SC836B models only)

Figure 4-1. Front and Rear View

4-1
SC836 Chassis Manual

4-2 Removing Power from the System


Before performing some setup or maintenance tasks, use the following procedure
to ensure that power has been removed from the system.
1. Use the operating system to power down the node, following the on-screen
prompts.

2. After the system has completely shut-down, carefully grasp the head of the
power cord and gently pull it out of the back of the power supply. If your system
has dual power supplies, remove the cords from both power supplies.

3. Disconnect the cord from the power strip or wall outlet.

4-2
Chapter 4: Chassis Setup and Maintenance

4-3 Removing the Chassis Cover

13
13

13

Release Tab
2
Remove this screw

(if necessary)

Figure 4-2. Removing the Chassis Cover

Removing the Chassis Cover

1. If necessary, unplug the chassis from any power source

2. If necessary, remove the two screws securing the cover to the side of the chassis.

3. Depress the two release buttons, pushing the cover toward the rear of the
chassis, and lift it up and off.

Caution: Except for short periods of time, do not operate the server without the
cover in place. The chassis cover must be in place to allow proper airflow and
prevent overheating.

4-3
SC836 Chassis Manual

4-4 Installing Hard Drives

Primary Hot-Swap Drives


The drives are mounted in drive carriers to simplify their installation and removal
from the chassis. These carriers also help to promote proper airflow for the drive
bays.
Enterprise level hard disk drives are recommended for use in Supermicro chassis
and servers.

Figure 4-3. Removing Hard Drive

Removing Hard Drive Carriers from the Chassis

1. Press the release button on the drive carrier. This extends the drive carrier
handle.

2. Use the handle to pull the drive carrier out of the chassis.

4-4
Chapter 4: Chassis Setup and Maintenance

Caution: Except for short periods of time, such as while swapping hard drives,
do not operate the server with the carriers removed from the chassis drive bays.

Dummy Drive
1
Drive Carrier

Figure 4-4. Removing the Dummy Drive from the Carrier

Installing a Hard Drive into the Hard Drive Carrier

1. Remove the two screws securing the dummy drive to the drive carrier and
remove the dummy drive. Place the hard drive carrier on a flat surface such as
a desk, table or work bench.

2. Slide the hard drive into the carrier with the printed circuit board side facing down.

3. Carefully align the mounting holes in both the drive carrier and the hard drive.

4-5
SC836 Chassis Manual

SAS/SATA
Hard Drive

4
Drive Carrier

Figure 4-5. Installing the Hard Drive into the Carrier

4. Secure the hard drive to the carrier using six screws.

5. Replace the drive tray into the chassis. Make sure to close the drive carrier
handle to lock the drive carrier into place.

4-6
Chapter 4: Chassis Setup and Maintenance

Optional HDDs in the Rear of the Chassis


Chassis models SC836Bxx... offer the option of adding two hot-swap 2.5" hard
disk drives accessable from the rear of the chassis. It requires the kit, MCP-220-
83605-0N.

Figure 4-6. Removing the Cover Plate

Installing the Hot-Swap Drive Kit


4
(A more detailed procedure can be found in Appendix D.)

1. Remove the small external cover plate from the rear of the chassis by removing
the screws under the chassis.

2. From the kit, on the mounting cage at the end opposite where the drives will be
inserted, mount the small PCB backplane using three screws.

Figure 4-7. Attaching the PCB Backplane to the Hot-Swap HDD Cage

4-7
SC836 Chassis Manual

Figure 4-8. Installing Rear Hot-Swap Drives

3. Attach cables to the small PCB backplane. Route the cables into the chassis
and through the chassis opening under the power supplies.

4. Insert the drive cage assembly into the chassis carefully following the cables.
4 Secure the cage with screws through the bottom of the chassis.

5. Attach power and data cables to the power distributor and the serverboard.

6. Slide two 2.5" hard drives mounted in hard drive carriers into the tray.

Figure 4-9. Inserting the Rear Drives

4-8
Chapter 4: Chassis Setup and Maintenance

4-5 Expansion Cards


The chassis includes seven PCI slots for full-height, full-length expansion cards.
Installing Expansion Cards

1. Power down the system as described in Section 4-2, lay the chassis on a flat
surface, and open the chassis cover.

2. Remove the screw holding the chassis slot shield in place.

3. Insert the expansion card into the serverboard slot, while aligning the expansion
card shield with the slot in the rear of the chassis.

4. Secure expansion card shield to the chassis using the screw previously removed.

4-9
SC836 Chassis Manual

4-6 Installing the Air Shroud

Figure 4-10. Air Shroud Installation

Air shrouds concentrate airflow to maximize fan effectiveness. It does not require
screws for its installation. It is designed with removeable break-away tabs that allow
the air shroud to be adjusted to fit a variety of serverboards.
Installing the Air Shroud

1. Power down the system as described in Section 4-2 and remove the cover.

2. Place the air shroud in the chassis. The air shroud fits behind the fans and
beside to the power supply.

3. After checking the fit of the air shroud, remove any break-away tabs necessary
to ensure a proper fit with the serverboard.

4-10
Chapter 4: Chassis Setup and Maintenance

4-7 System Fans


Three hot-swappable, heavy-duty fans provide cooling from the middle of the
chassis, augmented by two rear exhaust fans.

Release Tab

Airflow Direction
Indicator

Figure 4-11. System Fan

Replacing a System Fan

1. Open the chassis while the power is running to determine which fan has failed.
(Never run the server for an extended period of time with the chassis cover
open.)

2. Remove the failed fan's power cord from the serverboard.

3. Press the fan release tab to lift the failed fan from the chassis and pull it
completely out of the chassis.

4. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating airflow direction) point in the same
direction as the arrows on the other fans.

5. Check that the fan is working properly before replacing the chassis cover.

4-11
SC836 Chassis Manual

Figure 4-12. Placing the System Fan

Checking the Server Air Flow


Checking the Air Flow

• Make sure there are no objects to obstruct airflow in and out of the server. In
addition, if you are using a front bezel, make sure the bezel's filter is replaced
periodically.

• Do not operate the server without drives or drive trays in the drive bays. Use
only recommended server parts.

• Make sure no wires or foreign objects obstruct air flow through the chassis. Pull
all excess cabling out of the airflow path or use shorter cables.

The control panel LEDs inform you of system status. See “Chapter 4: System
Interface” for details on the LEDs and the control panel buttons.

4-12
Chapter 4: Chassis Setup and Maintenance

4-8 Power Supply


The chassis has a redundant power supply. Redundant power supplies are hot-
swappable, and can be changed without powering down the system. New units can
be ordered directly from Supermicro.
This power supply is auto-switching capable. This enables it to automatically sense
and operate at a 100v to 240v input voltage. An amber light will be illuminated on
the power supply when the power is off. An illuminated green light indicates that
the power supply is operating.

Figure 4-13. Power Supply Module

4-13
SC836 Chassis Manual

Changing the Power Supply:

1. Unplug the AC cord from the module to be replaced.

2. Push the release tab on the back of the power supply as illustrated.

Release Tab

Figure 4-14. Power Supply Release Tab

3. Pull the power supply out using the handle provided.

4. Replace the failed power module with the same model.

5. Push the new power supply module into the power bay until it clicks.

6. Plug the AC power cord back into the module.

4-14
Chapter 5: Rack Intallation

Chapter 5

Rack Installation

This chapter provides instructions for preparing and mounting your chassis in a rack.

5-1 Unpacking the System

You should inspect the box the chassis was shipped in and note if it was damaged
in any way. If the chassis itself shows damage, file a damage claim with the carrier
who delivered it.

5-2 Preparing for Setup

Decide on a suitable location for the rack unit that will hold your chassis. It should
be a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical
noise and electromagnetic fields are generated. A nearby grounded power outlet.
is required

The box your chassis was shipped in should include two sets of rail assemblies, two
rail mounting brackets and the mounting screws to mount the system into the rack.
Please read this chapter in its entirety before beginning the installation procedure.

Choosing a Setup Location


• Leave at least 25 inches clearance in front of the rack to open the front door
completely.
• Leave approximately 30 inches of clearance in the back of the rack to allow
for sufficient airflow and access for servicing.
• It should be a restricted access location, such as a dedicated equipment room
or a service closet.

5-1
SC836 Chassis Manual

5-3 Warnings and Precautions

Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the floor with the full weight of the rack resting on them.

• In single rack installations, stabilizers should be attached to the rack.

• In multiple rack installations, the racks should be coupled together.

• Always make sure that the rack is stable before extending a component from
the rack.

• Only one chassis should be extended from the rack at a time. Extending two
or more chassis simultaneously may cause the rack to become unstable.

General Server Precautions


• Review the electrical and general safety precautions that came with the com-
ponents you are adding to your chassis.

• Determine the placement of each component in the rack before you install the
rails.

• Install the heaviest server components on the bottom of the rack first, and
then work upward.

• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.

• Allow the hot-swappable hard drives and power supply modules to cool be-
fore touching them.

• Always keep the rack's front door and all panels and components on the serv-
ers closed when not servicing to maintain proper cooling.

5-2
Chapter 5: Rack Intallation

Rack Mounting Considerations

Ambient Operating Temperature

If installed in a closed or multi-unit rack assembly, the ambient operating tempera-


ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (TMRA).

Sufficient Airflow

Equipment should be mounted into a rack so that the amount of airflow required
for safe operation is not compromised.

Circuit Overloading

Consideration should be given to the connection of the equipment to the power


supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.

Reliable Ground

A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).

Warning: To prevent bodily injury when mounting or servicing this unit in a


rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:

• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.

• When mounting this unit in a partially filled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.

• If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.

• Slide rail mounted equipment is not to be used as a shelf or a work space.

5-3
SC836 Chassis Manual

5-4 Installing the System into a Rack

This section provides information on installing the server into a rack with the rails
provided. There are a variety of racks on the market, so the assembly procedure
may differ slightly. Refer to the installation instructions that came with your rack.
Note: These rails fit a rack between 26.5" and 36.4" deep.

Identifying the Sections of the Rack Rails


The chassis package includes two rail assemblies, one designed and labeled for
each side of the chassis. Each assembly consists of an inner rail that secures
directly to the chassis, and an outer rail that secures to the rack. The outer rail has
two sections that can slide and adjust to fit your rack depth.

Right Side
Outer Rail

Right Side
Inner Rail

Figure 5-1. Identifying the Rails

5-4
Chapter 5: Rack Intallation

Releasing the Inner Rail


Each inner rail has a locking latch. This latch prevents the server from coming
completely out of the rack when when the chassis is pulled out for servicing.

To mount the rail onto the chassis, first release the inner rail from the outer rails.

Releasing Inner Rail from the Outer Rails

1. Pull the inner rail out of the outer rail until it is fully extended as illustrated below.

2. Press the locking tab down to release the inner rail.

3. Pull the inner rail all the way out..

12

13

Figure 5-2. Extending and Releasing the Inner Rail

5-5
SC836 Chassis Manual

Installing the Inner Rails on the Chassis


Installing the Inner Rails

1. Identify the left and right inner rails. They are labeled.

2. Place the inner rail firmly against the side of the chassis, aligning the hooks on
the side of the chassis with the holes in the inner rail.

3. Slide the inner rail forward toward the front of the chassis until the quick release
bracket snaps into place, securing the rail to the chassis.

4. Optionally, you can further secure the inner rail to the chassis with screws. .

Inner Rails

12

14

13
Figure 5-3. Installing the Inner Rails

Figure 5-4. Inner Rails Installed on the Chassis

5-6
Chapter 5: Rack Intallation

Installing the Outer Rails onto the Rack


Installing the Outer Rails

1. Press upward on the locking tab at the rear end of the middle rail.

2. Push the middle rail back into the outer rail.

3. Hang the hooks on the front of the outer rail onto the square holes on the front
of the rack. If desired, use screws to secure the outer rails to the rack.

4. Pull out the rear of the outer rail, adjusting the length until it just fits within the
posts of the rack.

5. Hang the hooks of the rear section of the outer rail onto the square holes on the
rear of the rack. Take care that the proper holes are used so the rails are level.
If desired, use screws to secure the rear of the outer rail to the rear of the rack.

6. Repeat for the other outer rail.

1
L-min=676.00(26.61")(outer rail)
14

21D01
12

13

Figure 5-5. Extending and Mounting the Outer Rails

Stability hazard. The rack stabilizing mechanism must be in place, or the rack
must be bolted to the floor before you slide the unit out for servicing. Failure to
stabilize the rack can cause the rack to tip over.

Do not use a two post "telco" type rack.

5-7
SC836 Chassis Manual

Sliding the Chassis onto the Rack Rails


Warning: Mounting the system into the rack requires at least two people to
support the chassis during installation. Please follow safety recommendations
printed on the rails.

Installing the Chassis into a Rack

1. Align the inner rails of the chassis with the outer rails on the rack.

2. Slide the inner rails into the outer rails, keeping the pressure even on both
sides. When the chassis has been pushed completely into the rack, it should
click into the locked position.

3. Optionally, screws may be used to hold the front of the chassis to the rack.

Figure 5-6. Installing into a Rack

Note: The figure above is for illustrative purposes only. Always install servers to
the bottom of the rack first.

Caution: Do not pick up the server with the front handles. They are designed
to pull the system from a rack only.

5-8
Appendix A: Chassis Cables

Appendix A

Cables

This appendix describes cables compatible with your chassis system. Some
motherboards require non-standard cables. More information may be obtained
from the manufacturer of the motherboard or our web site at: www.supermicro.com.

A-1 Standard and Optional Cables for SC836 Models


The tables below list included and optional cables available by model and by the
Supermicro cable part number. A brief description of each cable by part number
follows.

836BE1C 836BE2C 836BHA 836BHE16 836BHE26 836BE16 836BE26 836BA

CBL # 2 models 2 models 2 models

0071L ● ● ● ● ● ● ● ●

0088L ● ●

***Cables listed below are optional***


0084 ● ● ● ● ● ●

0157L ● ● ● ● ● ●

0044L ● ● ● ● ● ●

0082L ● ● ● ● ● ●

0296L ● ● ● ● ● ●

0108L-02 ● ● ● ● ● ●

0281L ● ● ● ● ● ●

836E16 836E26 836A 836TQ

CBL # -R500B -R1200B -R1200B -R800B/V -R710B -R500B

0071L ● ● ● ● ● ● ●

0088L

0180L-01 ● ● ●

0087 ● ● ● ●

0078 ●

0139L ●

A-1
SC836 Chassis Manual

836E16 836E26 836A 836TQ

CBL # -R500B -R1200B -R1200B -R800B/V -R710B -R500B

***Cables listed below are optional***


0084 ● ● ● ● ●

0157L ● ● ● ● ●

0044L ● ● ● ● ● ● ●

0082L ● ● ● ● ● ● ●

0296L ● ● ● ● ● ● ●

0108L-02 ● ● ● ●

0281L ● ● ● ●

Cable Description by Part Number


CBL # Description
0071L Front panel, Round 16-pin to 16 Pin Ribbon FP cable 75cm. 28AWG
0088L Fan, 10.5" 4-pin Middle fan power extension (PWM). 24AWG
0180L-01 SATA Cable Set
0087 20" 16-pin to 16-pin Round Ribbon Cable
0078 floppy, 45cm Round Floppy Cable
0139L DVD drive 50cm Cable
0084 Split Front Panel Cable
0157L SGPIO, 8-pin to 8-pin Ribbon Cable for SGPIO (For Additonal Drives)
0044L SATA S-S, 61cm
0082L SATA Power Y Split Adapter
0296L Fan, 4-pin fan extension cord, 9" length
0108L-02 SFF 8087 to SFF 8087 Internal Backplane Cable, 39cm
0281L SFF 8087 to SFF 8087 Internal Backplane Cable, 75cm

A-2
Appendix A: Chassis Cables

A-2 SAS Cables


Some compatible motherboards have varying types of SAS connectors. This section
lists optional compatible cables. Note: For SAS2 or SAS3, see Appendix C.

Alternate SAS Cables


If your motherboard has only one SAS connector that the SAS cables must share,
use one of the following cables. These cables must be purchased separately.

Cable Name: SAS Cable Quantity: 1


Part #: CBL-0175L Placement: Internal cable
Alt. Name: "Big Four"

Description: This cable has one SFF-8484 (32-pin) connector on one end and
four SAS connectors (7 pins each) at the other. This cable connects from the host
(motherboard or other controller) to the backplane SAS hard drive port.

Cable Name: SAS Cable Quantity: 1


Part #: CBL-0116 Placement: Internal cable
Alt. Name: iPass or "Small Four"

Description: This cable has one iPass (SFF-8087/Mini-SAS) connector (36-pin) at


one end and four SAS connectors on the opposite end. This cable connects from
the host (motherboard or other controller) to the backplane SAS hard drive port.

Cascading/JBOD SAS Cables


Use the following cables when setting up a cascading or JBOD system.

Cable Name: SAS Cable Quantity: varies by setup


Part #: CBL-0167L Placement: Internal cable
Ports: Single
Description: Internal cable. Connects the backplane to the host bus adapter or
external port. Used in single port environments.

A-3
SC836 Chassis Manual

Cable Name: SAS Cable Quantity: varies by setup


Part #: CBL-0168L Placement: Internal cable
Ports: Dual

Description: Internal cascading cable. Connects the backplane to the host bus
adapter or external port. Used in dual port environments.

Cable Name: SAS Cable Quantity: varies by setup


Part #: CBL-0166L Placement: External cable
Ports: Single or Dual
Description: External cascading cable. Connects ports between servers. With most
connectors, use one cable for single port connections and two cables for dual port
connections.

A-4
Appendix A: Chassis Cables

A-3 Extending Power Cables


Some compatible motherboards have power connectors in locations that require
extended power cables. Use the following chart as a guide.

Power Cable Extenders


Number of Pins Cable Part # Length
24-pin CBL-0042 7.9” (20 cm)

20-pin CBL-0059 7.9” (20 cm)

8-pin CBL-0062 7.9” (20 cm)

4-pin CBL-0060 7.9” (20 cm)

A-4 Front Panel to the Motherboard


The chassis includes a cable to connect the chassis front panel to the motherboard.
If your motherboard uses a different connector, use the following list to find a
compatible cable.

Front Panel to Motherboard Cable (Ribbon Cable)


Number of Pins Number of Pins
Cable Part #
(Front Panel) (Motherboard)
16-pin 16-pin CBL- 049

16-pin 20-pin CBL-0048

20-pin 20-pin CBL-0047

16-pin varies CBL-0068

20-pin various* CBL-0067


* Split cables: Use these cable if your motherboard requires several different
connections from the front panel.

A-5
SC836 Chassis Manual

Notes

A-6
Appendix B: Power Supply Specifications

Appendix B

SC836 Power Supply Specifications

This appendix lists power supply specifications for your chassis system.

1280W (Redundant)

MFR Part # PWS-1K28P-SQ

1000W Output @ 100-140V, 12-8A, 50-60Hz


AC Input
1280W Output @ 180-240V, 8-6A, 50-60Hz
1000W: +12V/83A; +5Vsb/4A
DC Output
1280W: +12V/106.7A, +5Vsb/4A

1200W (Redundant)
MFR Part # PWS-1K21P-1R
100 - 140V, 50 - 60Hz, 8 - 11.5 Amp
AC Input
180 - 240V, 50 - 60Hz, 5.5 - 8 Amp
1000W, 83 Amp @ 100-140V
DC Output
1200W, 100 Amp @ 180-240V
+12V
5Vsb: 4A
+5V: 50 Amp
DC Output
+3.3V: 30 Amp
with PDB
-12V: 0.6 Amp

1000W (Redundant)

MFR Part # PWS-1K03A-1R

AC Input 100-240V, 11-4.5A, 50-60Hz

DC Output +12V/75A; +5Vsb/4A

920W (Redundant)

MFR Part # PWS-920P-SQ

AC Input 100-240V, 11-4.5A, 50-60Hz

DC Output +12V/75A; +5Vsb/4A

B-1
SC836 Chassis Manual

800W (Redundant)

MFR Part # PWS-801-1R

100 - 240V
Rated AC Voltage 50 - 60Hz
10A - 4 Amp

+5V standby 4 Amp

+12V 66 Amp

+5V 25 Amp

+3.3V 12 Amp

710W (Redundant)

MFR Part # PWS-711-1R

Rated DC Input Voltage Range: -36 to -75V (24A-11A)


Voltage Nominal Voltage: -48V

+5V standby 4 Amp

+12V 58 Amp

+5V 24 Amp

+3.3V 21 Amp

-12V 0.6 Amp

500W (Redundant)

MFR Part # PWS-501P-1R

AC Input 100-240 V, 50-60 Hz, 6.1-2.6 Amp

4 Amp @ +5V standby


DC Output
41.7 Amp @ +12V
+5V 30 Amp

+3.3V 24 Amp

-12V 0.6 Amp

B-2
Appendix C Backplane Specifications

Appendix C

Backplane Specifications

C-1 Overview
This appendix provides details about the backplanes used in the various models
of the SC836 chassis.

Model Backplane Section


SC836BE1C-R1K03B BPN-SAS3-836EL1 C-6
SC836BE2C-R1K03B BPN-SAS3-836EL2 C-6
SC836BHA-R1K28B BPN-SAS-836A C-3
SC836BHE16-R1K28B BPN-SAS2-836EL1 C-5
SC836BHE26-R1K28B BPN-SAS2-836EL2 C-5
SC836BE16-R1K28B BPN-SAS2-836EL1 C-5
SC836BE26-R1K28B BPN-SAS2-836EL2 C-5
SC836BA-R1K28B BPN-SAS-836A C-3
SC836BE16-R920B BPN-SAS2-836EL1 C-5
SC836BE26-R920B BPN-SAS2-836EL2 C-5
SC836BA-R920B BPN-SAS-836A C-3
SC836TQ-R500B BPN-SAS-836TQ C-4
SC836E16-R500B BPN-SAS2-836EL1 C-5
SC836E16-R1200B BPN-SAS2-836EL1 C-5
SC836E26-R1200B BPN-SAS2-836EL2 C-5
SC836A-R1200B BPN-SAS-836A C-3
SC836TQ-R800V/B BPN-SAS-836TQ C-4
SC836TQ-R710B BPN-SAS-836TQ C-4

All images and layouts shown in this guide are based upon the latest PCB revision
available at the time of publishing. Your backplane may or may not look exactly
the same. Refer to the Supermicro web site at www.supermicro.com for the latest
updates, compatible parts and supported configurations.

C-1
SC836 Chassis Manual

C-2 Safety Guidelines

ESD Safety Guidelines


Electrostatic Discharge (ESD) can damage electronic com­ ponents. To prevent
damage to your system, it is important to handle it very carefully. The following
measures are generally sufficient to protect your equipment from ESD.
• Use a grounded wrist strap designed to prevent static discharge.

• Touch a grounded metal object before removing a component from the antistatic
bag.

• Handle the backplane by its edges only; do not touch its components, peripheral
chips, memory modules or gold contacts.

• When handling chips or modules, avoid touching their pins.

• Put the backplane and peripherals back into their antistatic bags when not in use.

General Safety Guidelines


• Always disconnect power cables before installing or removing any components
from the computer, including the backplane.

• Disconnect the power cable before installing or removing any cables from the
backplane.

• Make sure that the backplane is securely and properly installed on the
motherboard to prevent damage to the system due to power shortage.

C-2
Appendix C Backplane Specifications

C-3 BPN-SAS-836A Backplane

Front Connectors

18 13 17 16 15 13
111 110
110 111 111
111
14
14 1
14
14 19 19 19 19 12

Figure A-1. Front Connectors

#1. Activity LED Header #7. I2C Connector#3 JP52


ACT_IN#0-7: JP26 #8. I2C Connector#4 JP96
#2. Activity LED Header #9. Power Connectors (4-pin): JP10,
ACT_IN#8-15: JP47 JP13, JP46, and JP48
#3. Chip: MG9072 #10. Upgrade Connectors: JP69 and
#4. Fan Connectors: JP54, JP56, JP78
JP58 and JP60 #11. IPASS Connectors JSM1, JSM2,
#5. I2C Connector#1 JP37 JSM3 and JSM4
#6. I2C Connector#2 JP95

C-3
SC836 Chassis Manual

Front Connector and Pin Definitions


#1 - #2. Activity LED Header SAS Activity LED Header
Pin Definitions
The activity LED headers, designated JP26
Pin # Definition Pin # Definition
and JP47, are used to indicate the activity
1 ACT IN#0 6 ACT IN#4
status of each SAS drive. These activity LED
2 ACT IN#1 7 ACT IN#5
headers are used by the host controller for
3 ACT IN#2 8 ACT IN#6
the SATA drives that previously had no activity
4 ACT IN#3 9 ACT IN#7
status output. If using a SAS drive, and for
5 Ground 10 Empty
most SATA drives, these activity headers are
not required.The Activity LED Header is located
on the front panel. For the Activity LED Header
SAS Activity LED Header
to work properly, connect using a 10-pin LED Pin Definitions
cable. Pin # Definition Pin # Definition

1 ACT IN#8 6 ACT IN#12

2 ACT IN#9 7 ACT IN#13

3 ACT IN#10 8 ACT IN#14

4 ACT IN#11 9 ACT IN#15

5 Ground 10 Empty

#3. MG9072 Chips


The MG9072 chips are enclosure management
chips that support the SES-2 controller and
SES-2 protocols.

#4. Fan Connectors Fan Connectors

The 4-pin connectors, designated JP54, JP56,


Pin# Definition
JP58 and JP60, provide power to the fans.
1 Ground
See the table on the right for pin definitions.
2 +12V
These 4-pin connectors are compatible with
3 Tachometer
3-pin and 4-pin fans.
4 No connection

C-4
Appendix C Backplane Specifications

#5., #6., #7., #8. I2C Connectors I2C Y-Cable


Connector
The I C connectors, designated JP37, JP52,
2
Pin Definitions
JP95, and JP96, are for enclosure manage- Pin# Definition
ment of the I2C mode connection. See the 1 Data
table on the right for pin definitions. 2 Ground

3 Clock

4 No Connection

#9. Backplane Main Power Connectors Backplane


Main Power
The 4-pin connectors, designated JP10, 4-Pin Connector
JP13, JP46, and JP48, provide power to the Pin# Definition
backplane. See the table on the right for pin 1 +12V
definitions. All four of these connectors must 2 and 3 Ground
be used at the same time. 4 +5V

#10. Upgrade Connectors


The upgrade connectors are designated
JP69 (for U19) and JP78 (for U40). Upgrade
connectors are for manufacturing use only.

C-5
SC836 Chassis Manual

Front Jumper Locations and Pin Definitions

JP84
JP35
JP50
JP100
JP99
JP61 JP62
JP98 JP63
JP97
JP64
Figure A-2. Front Jumpers

Explanation of Jumpers
3 2 1
To modify the operation of the backplane, Connector
Pins
jumpers can be used to choose between
optional settings. Jumpers create shorts
between two pins to change the function
of the connector. Pin 1 is identified with Jumper

a square solder pad on the printed circuit


board.
3 2 1
Note: On two pin jumpers, "Closed" means Setting
the jumper is on and "Open" means the
jumper is off the pins.

General Jumper Settings

Jumper Jumper Settings Note


Open: Default MG9072 chip reset #1
JP35
Closed: Reset
Open: Default MG9072 chip reset #2
JP50
Closed: Reset

C-6
Appendix C Backplane Specifications

Fan Jumper Settings


The BPN-SAS-836A backplane can use up to four fans. To utilize each fan, both
jumpers must be configured as instructed below.

Fan Jumper Settings

Jumper Jumper Settings Note


Closed: With fan (default) Fan#1 enable/disable
JP61
Open: No fan
JP54 Fan#1 connector
Closed: With fan (default) Fan#2 enable/disable
JP62
Open: No fan
JP56 Fan#2 connector
Closed: With fan (default) Fan#3 enable/disable
JP63
Open: No fan
JP58 Fan#3 connector
Closed: With fan (default) Fan#4 enable/disable
JP64
Open: No fan
JP60 Fan#4 connector
1-2 With fan (default) Fan #1 selection for MG907X
JP97
2-3 No fan Monitor
1-2 With fan (default) Fan #2 selection for MG907X
JP99
2-3 No fan Monitor
1-2 With fan (default) Fan #3 selection for MG907X
JP100
2-3 No fan Monitor
1-2 With fan (default) Fan #4 selection for MG907X
JP100
2-3 No fan Monitor

I2C and SGPIO Modes and Jumper Settings


This backplane can utilize I2C or SGPIO. SGPIO is the default mode and can be
used without making changes to your jumpers. The following information details
which jumpers must be configured to use SGPIO mode or restore your backplane
to I2C mode.

SGPIO/I2C Setting

Jumper SGPIO Jumper Setting I2C Jumper Setting


JP84 1-2 (default) 2-3

C-7
SC836 Chassis Manual

Front LED Indicators

POWER LEDS

FAN FAILURE LEDS ALARM LEDS

Figure A-3. Front LEDs

Front LEDs

LED State Specification


Fan #1 Fail On Fan #1 failure
Fan #2 Fail On Fan #2 failure
Fan #3 Fail On Fan #3 failure
Fan #4 Fail On Fan #4 failure
Overheat/fan failure/drive failure in
Alarm #1 On
Channel 1
Overheat/fan failure/drive failure in
Alarm #2 On
Channel 2
Backplane power failure. Light is on
+5V Off
during normal operation.
Backplane power failure. Light is on
+12V Off
during normal operation.

C-8
Appendix C Backplane Specifications

Rear Connectors and LED Indicators


D15 D24 D28 D87

ACT#15

D87
ACT#11
D33 D88

ACT#7

C
C

C
D24

C
D15

D28
D8 D29

R88

R177
ACT#3

R173

R191
R187
A

A
R428
C

C
R218
D33
SAS #7 SAS #11 SAS #15

R178
FAIL#3

FAIL#7

D29
D8

FAIL#15
SAS #3

FAIL#11
R90

A
A

A
R435

D88
J4 J15 J20 J31

R182
RP3

SAS SAS SAS SAS

J15 J20 J31


C94

J4

ACT#14
D27
#3 #7

D42
#15

D22
#11

D14
Q54

D42 C
R253
R158

R381
R345 R346 R105 R190 R395
R301 R347 R141

D27
C

C
ACT#6
R456 C89

D22
D32

ACT#10
R102 R108

D39
R310

D7 D23

R164

Q31 Q32
A

A
C

C
R176 R181
FAIL#10

R217
FAIL#6

R221
D23
SAS #6 SAS #10

D32
SAS #14

R165

A
A

A
D39 FAIL#14
Q33
SAS #2
J3 J13 J19 J28

R215
SAS SAS SAS R385

J13 J19

ACT#13
J28
#2 #6

D26
#10

J3
#14 Q44 Q43

D21 D41

R220
R443

D13

C150

D41 C
ACT#9
R157

ACT#5
R199 R146

D21
C
C

C
D26
ACT#1

R251
D13
R442

D31

R150
Q5 Q7 Q6 R390Q45

R84

R382
D20

R175
D38

R195

R193
D6
A

A
RT2
C

C
R202

Q24 Q23
R198
FAIL#1

R109
R189

FAIL#9
R87
R376

R214
D50

D31
SAS #9
R92

SAS #5

FAIL#5
A

A
A

A
D6

D20

Q17 Q16

D38
J18 J27

SAS #13
J2 J11

R149
Q41 Q40

SAS #1

R180
C262

FAIL#13
Q22
R314

Q3
SAS SAS SAS

R115

R384
R308 SAS

Q14
C261

Q18
D40
#1

J11 J18 D18 D25

R145
#5 #9

D12

ACT#12
R380
J2
Q4

J27
#13
R91

Q42
R389
R379

R219
D40
R192
R101

ACT#8
R188
R151

ACT#4

D25
C

C
R375

D37
ACT#0

D12

D18
D30
SAS836A

D5 D19

R250
R83

R95

R174
FAIL#8
A

A
C

C
REV 1.00

FAIL#12
SAS #4 SAS #8 SAS #12

D19
FAIL#4
R96

R179

D30
R85

D5
FAIL#0

A
A

R213

D37
J1 J9 J17 J21

SAS #0
SAS SAS
SAS SAS

J9 J17 J21
#0 #4 #8
#12

J1
Figure A-4. Rear Connectors and LEDs
Rear SAS/SATA Connectors

Rear SAS Drive Rear SAS Drive


Connector Number Connector Number
SAS #0 SAS/SATA HDD #0 SAS #8 SAS/SATA HDD #8
SAS #1 SAS/SATA HDD #1 SAS #9 SAS/SATA HDD #9
SAS #2 SAS/SATA HDD #2 SAS #10 SAS/SATA HDD #10
SAS #3 SAS/SATA HDD #3 SAS #11 SAS/SATA HDD #11
SAS #4 SAS/SATA HDD #4 SAS #12 SAS/SATA HDD #12
SAS #5 SAS/SATA HDD #5 SAS #13 SAS/SATA HDD #13
SAS #6 SAS/SATA HDD #6 SAS #14 SAS/SATA HDD #14
SAS #7 SAS/SATA HDD #7 SAS #15 SAS/SATA HDD #15
Rear LED Indicators

Rear LED Hard Drive Activity Failure LED


SAS #0 D12 D5
SAS #1 D13 D6
SAS #2 D14 D7
SAS #3 D15 D8
SAS #4 D18 D19
SAS #5 D21 D20
SAS #6 D22 D23
SAS #7 D24 D29
SAS #8 D25 D30
SAS #9 D26 D31
SAS #10 D27 D32
SAS #11 D28 D33
SAS #12 D40 D37
SAS #13 D41 D38
SAS #14 D42 D39
SAS #15 D87 D88

C-9
SC836 Chassis Manual

C-4 BPN-SAS-836TQ Backplane

Front Connectors

12 12
114 13 13 R194 R324 R325

114
R105 R246 R459
C89 C86

+
C198
BAR CODE

C200

+ +

JP106
BZ1 1 FAN#1 FAN#2 FAN#3 FAN#4 ALARM#1 ALARM#2 +5V +12V
BUZZER RESET UPGRADE#2 1 JP84 FAIL FAIL FAIL FAIL
+
JP25 D3 D36 D53 D54
C

JP45
1 UPGRADE#1 A CA CA C A C A CA CA
#15

C45

C284
1
D85 D79

JP69
D70 49
49

#3
JP18 C178

48
1
48

C162

#7
17 16 15

#11
18
J32 J25 J16 J8
C177
C204 C202 C5
C275 C285
C102

C100

33
33

17 17
32

+ +
32 R351 C176
R353 C88 Y1
C130

#2
R268 R170 U34
R273 R169
Y2

#10
C229 C158
C159 C139
D73 C245 C121
D69 C122 D66
#14

#6
R249
C148
14
R458
R455

1
I2C#4 JP100

14
U67
1 C173 JP97:FAN#1 SELECT I2C#2 R443 I2C#1
J30 C175 J24 I2C#3 JP52
JP95 J7
JP98:FAN#2 SELECT 1-2:WITH FAN C84
J14 1
C44
C199 C197
1 JP99:FAN#3 SELECT 2-3:NO FAN
+ JP99
C174
JP100:FAN#4 SELECT 1

+ + +
R393
SAS836TQ

JP50
REV 3.2

J29 C170

110

JP68
1

#9

112 11
R332
R222
C226 C155
C227 D83 D72

#5
D61
#13

C171 C29

#1
1
C172

113

R314
F3

J23
C267 R338 R339

R308
JP48 1 4

ACT13
ACT14

ACT15
JP63

+
C201
4

1
4

14
JP62 J12

JP60
C203 C85 C3 J6

+
F16 F15
ACT12 JP58
1
F1

FAN#2

JP26
+ +
JP46

JP13

JP10
C195

JP56 JP47

ACT0

ACT1

ACT2

ACT3
JP61
R437

ACT9

ACT10

ACT11
ACT8

R439
JP54 1 4 1 4
F14

F2

D46 F4 JP64
#12

#4
D60 C23 D55

1
C79 C80 D64

#0
19 19 19 14 19
#8

C258 JP61:FAN#1 SELECT F9


C257 JP62:FAN#2 SELECT ON:WITH FAN
FAN#1 JP63:FAN#3 SELECT OFF:NO FAN
JP64:FAN#4 SELECT
C179

J26 J22 J10 J5

Figure TQ-1. Front Components

#1. ACT_IN#0-15: JP26 and JP47 #15. SAS Port #0 J5


#2. DVD-ROM Drive Power: JP105 #16. SAS Port #1 J6
and JP106 #17. SAS Port #2 J7
#3. Chip: MG9072 #18. SAS Port #3 J8
#4. Fan Connectors: JP54, JP56, #19. SAS Port #4 J10
JP58 and JP60 #20. SAS Port #5 J12
#5. I2C Connector#1 JP37 #21. SAS Port #6 J14
#6. I2C Connector#2 JP95 #22. SAS Port #7 J16
#7. I2C Connector#3 JP52 #23. SAS Port #8 J22
#8. I2C Connector#4 JP96 #24. SAS Port #9 J23
#9. Power Connectors (4-pin): JP10, #25. SAS Port #10 J24
JP13, JP46, and JP48 #26. SAS Port #11 J25
#10. SideBand Connector#1 JP66 #27. SAS Port #12 J26
#11. SideBand Connector#2 JP68 #28. SAS Port #13 J29
#12. SideBand Connector#3 JP75 #29. SAS Port #14 J30
#13. SideBand Connector#4 JP77 #30. SAS Port #15 J32
#14. Upgrade Connector: JP69, JP78

SAS Ports
R194 R324 R325
R105 R246 R459
C89 C86

+
C198
BAR CODE

C200

+ +
JP106

FAN#1 FAN#2

310 216 212 118


BZ1 1 FAN#3 FAN#4 ALARM#1 ALARM#2 +5V +12V
BUZZER RESET UPGRADE#2 1 JP84 FAIL FAIL FAIL FAIL
+
JP25 D3 D36 D53 D54
C
JP45

1 UPGRADE#1 A CA CA C A C A CA CA
#15

C45

+
C284

1
D85 D79
JP69

D70 49
49
#3

JP18 C178
48

1
48

C162

#7
#11

J32 J25 J16 J8


C177
C204 C202 C5
C275 C285
C102

C100

+
33
33

17 17
32

+ +
32 R351 C176
R353 C88 Y1

219 215 211 117


C130

+
#2

R268 R170 U34


R273 R169
Y2
#10

C229 C158
C159 C139
D73 C245 C121
D69 C122 D66
#14

#6
R249
C148
R458
R455

I2C#4 JP100
U67
1 C173 JP97:FAN#1 SELECT I2C#2 R443 I2C#1
J30 C175 J24 I2C#3 JP52
JP95 J7
JP98:FAN#2 SELECT 1-2:WITH FAN C84
J14 1
C44
C199 C197
1 JP99:FAN#3 SELECT 2-3:NO FAN
+ JP99
C174
JP100:FAN#4 SELECT 1

+ + +
R393
SAS836TQ

JP50
REV 3.2

218 214 210 116


J29 C170
JP68

1
#9

R332
R222

C226 C155
C227 D83 D72
#5

D61
#13

C171 C29
#1

C172
R314

F3

J23
C267 R338 R339
R308

JP48 1 4
ACT13
ACT14

ACT15

JP63

+
C201
4

JP62 4 J12
JP60

C203 C85 C3 J6

+
F16 F15
ACT12 JP58
1
F1

FAN#2

JP26

+ +
JP46

JP13

JP10
C195

JP56 JP47
ACT0

ACT1

ACT2

ACT3

JP61

217 213 119 115


R437
ACT9

ACT10

ACT11

ACT8
R439

JP54 1 4 1 4
F14

F2

D46 F4 JP64
#12

#4

D60 C23 D55


C79 C80 D64
#0
#8

C258 JP61:FAN#1 SELECT F9


C257 JP62:FAN#2 SELECT ON:WITH FAN
FAN#1 JP63:FAN#3 SELECT OFF:NO FAN
JP64:FAN#4 SELECT
C179

J26 J22 J10 J5

Figure TQ-2. SAS Ports

C-10
Appendix C Backplane Specifications

Front Connector and Pin Definitions


#1. Activity LED Header SAS Activity LED Header
Pin Definitions
The activity LED headers, designated JP26
Pin # Definition Pin # Definition
and JP47, are used to indicate the activity
1 ACT IN#0 6 ACT IN#4
status of each SAS drive. These activity LED
2 ACT IN#1 7 ACT IN#5
headers are used by the host controller for
3 ACT IN#2 8 ACT IN#6
the SATA drives that previously had no activity
4 ACT IN#3 9 ACT IN#7
status output. If using a SAS drive, and for
5 Ground 10 Empty
most SATA drives, these activity headers are
not required.The Activity LED Header is located
on the front panel. For the Activity LED Header
SAS Activity LED Header
to work properly, connect using a 10-pin LED Pin Definitions
cable. Pin # Definition Pin # Definition

1 ACT IN#8 6 ACT IN#12

2 ACT IN#9 7 ACT IN#13

3 ACT IN#10 8 ACT IN#14

4 ACT IN#11 9 ACT IN#15

5 Ground 10 Empty

#2. CD-ROM 4-Pin Connectors CD-ROM/


FDD Power
The 4-pin connectors, designated JP105 and 4-Pin Connector
JP106, provide power to the CD-ROM drives.
See the table on the right for pin definitions. Pin# Definition

1 +5V

2 and 3 Ground

4 +12V

#3. MG9072 Chip


The MG9072 is an enclosure management
chip that supports the SES-2 controller and
SES-2 protocols.

C-11
SC836 Chassis Manual

#4. Fan Connectors Fan Connectors

The 4-pin connectors, designated JP54, JP56,


Pin# Definition
JP58 and JP60, provide power to the fans.
1 Ground
See the table on the right for pin definitions.
2 +12V
These 4-pin connectors are compatible with
3 Tachometer
3-pin and 4-pin fans.
4 No connection

#5., #6., #7., #8. I2C Y-Cable Connectors I2C Y-Cable


Connector
The I C Y-cable connectors, designated JP37,
2 Pin Definitions

JP52, JP95, and JP96, are for enclosure


Pin# Definition
management of the I2C mode connection.
1 Data
These connectors are used only if the I2C is
2 Ground
not embedded into the sideband connectors.
3 Clock
See the table on the right for pin definitions.
4 No Connection

#9. Backplane Main Power Connectors Backplane


Main Power
The 4-pin connectors, designated JP10, 4-Pin Connector

JP13, JP46, and JP48, provide power to the


Pin# Definition
backplane. See the table on the right for pin
1 +12V
definitions. All four of these connectors must
2 and 3 Ground
be used at the same time.
4 +5V

#10., #11., #12., #13. Sideband Sideband Headers


Headers
Pin # Definition Pin # Definition
The sideband headers are
2 SGPIO: 1 Controller ID (SB6)
designated JP66, JP68, JP75 SDIN
and JP77. are for enclosure I2C:
Backplane
management of the SGPIO mode Addressing
connection. See the table to the (SB5)

right for pin definitions. 4 SGPIO: 3 GND (SB2)


SDOUT

I2C: Reset
(SB4)

6 GND (SB3) 5 SGPIO: SLOAD

I2C:SDA (SB1)

8 Backplane 7 SGPIO: SCLOCK


ID (SB7)
I2C:SCL (SB0)

10 No Connec- 9 No Connection
tion

C-12
Appendix C Backplane Specifications

#14. Upgrade Connectors


The upgrade connectors are designated JP69 (for U19) and JP78 (for U40).
Upgrade connectors are for manufacturing use only.
#15-#30. SAS Ports
The SAS ports are used to connect the SAS drive cables. The 16 ports are
designated #0 - #15. Each port is also compatible with SATA drives.

C-13
SC836 Chassis Manual

Front Jumper Locations and Pin Definitions

JP84
R194 R324 R325
R105 R246 R459
C89 C86

+
C198
BAR CODE

C200

+ +

JP106
BZ1 1 FAN#1 FAN#2 FAN#3 FAN#4 ALARM#1 ALARM#2 +5V +12V
BUZZER RESET UPGRADE#2 1 JP84 FAIL FAIL FAIL FAIL
+
JP25 D3 D36 D53 D54
C

JP45
1 UPGRADE#1 A CA CA C A C A CA CA

#15
C45

C284
1
D85 D79

JP69
D70 49
49

#3
JP18 C178

48
1

48

C162

#7
#11
JP35
J32 J25 J16 J8
C177
C204 C202 C5
C275 C285
C102

C100

33
33
17 17
32

+ +
32 R351 C176
R353 C88

JP50
Y1
C130

#2
R268 R170 U34
R273 R169
Y2

#10
C229 C158
C159 C139
D73 C245 C121

JP100
D69 C122 D66
#14

#6
R249
C148
R458
R455
JP99
I2C#4 JP100
U67
1 C173 JP97:FAN#1 SELECT I2C#2 R443 I2C#1
J30 C175 J24 I2C#3 JP52
JP95 J7
JP98:FAN#2 SELECT 1-2:WITH FAN C84
J14 1
C44
C199 C197
1 JP99:FAN#3 SELECT 2-3:NO FAN
+ JP99
C174
JP100:FAN#4 SELECT 1

R393
+ + +
SAS836TQ

JP50
REV 3.2

JP61
J29 C170

JP68
1

#9

R332
R222
C226 C155
C227 D83 D72

#5
D61
#13

C171 C29

#1
C172

JP98 JP63

R314
F3

J23
C267 R338 R339

R308
JP48 1 4

ACT13
ACT14

ACT15
JP63

+
C201
4

1
JP62 4 J12

JP60
C203 C85 C3 J6

+
F16 F15
ACT12 JP58
1

JP97
F1

FAN#2

JP26
+ +

JP46

JP13

JP10
C195

JP56 JP47

ACT0

ACT1

ACT2

ACT3
JP61
R437

ACT9

ACT10

ACT11
ACT8

R439
JP54 1 4 1 4
F14

F2
D46 F4 JP64
#12

#4
D60 C23 D55
C79 C80 D64

#0
#8
C258 JP61:FAN#1 SELECT F9

JP64
C257

JP62
JP62:FAN#2 SELECT ON:WITH FAN
FAN#1 JP63:FAN#3 SELECT OFF:NO FAN
JP64:FAN#4 SELECT
C179

J26 J22 J10 J5

Figure TQ-3. Jumpers

Explanation of Jumpers
3 2 1
Connector
Pins
To modify the operation of the backplane,
jumpers can be used to choose between
optional settings. Jumpers create shorts
Jumper
between two pins to change the function
of the connector. Pin 1 is identified with
a square solder pad on the printed circuit 3 2 1
board. Setting

Note: On two pin jumpers, "Closed" means


the jumper is on and "Open" means the
jumper is off the pins.

General Jumper Settings

Jumper Jumper Settings Note


Open: Default 9072 Chip Reset #1
JP35
Closed: Reset
Open: Default 9072 Chip Reset #2
JP50
Closed: Reset

C-14
Appendix C Backplane Specifications

Fan Jumper Settings


The BPN-SAS-836TQ backplane can use up to four fans. To utilize each fan, you
must configure both jumpers as instructed below.

Fan Jumper Settings

Jumper Jumper Settings Note


Closed: With fan (default) Fan#1 enable/disable
JP61
Open: No fan
JP54 Fan#1 connector
Closed: With fan (default) Fan#2 enable/disable
JP62
Open: No fan
JP56 Fan#2 connector
Closed: With fan (default) Fan#3 enable/disable
JP63
Open: No fan
JP58 Fan#3 connector
Closed: With fan (default) Fan#4 enable/disable
JP64
Open: No fan
JP60 Fan#4 onnector
1-2 With fan (default) Fan #1 selection for MG907X
JP97
2-3 No fan Monitor
1-2 With fan (default) Fan #2 selection for MG907X
JP98
2-3 No fan Monitor
1-2 With fan (default) Fan #3 selection for MG907X
JP99
2-3 No fan Monitor
1-2 With fan (default) Fan #4 Sselection for MG907X
JP100
2-3 No fan Monitor

I2C and SGPIO Modes and Jumper Settings


This backplane can utilize I2C or SGPIO. SGPIO is the default mode and can be
used without making changes to your jumpers. The following information details
which jumpers must be configured to use SGPIO mode or restore your backplane
to I2C mode.

SGPIO/I2C Settings

Jumper SGPIO Setting I2C Setting


JP84 1-2 (default) 2-3

C-15
SC836 Chassis Manual

SAS Port Connections in I2C and SGPIO Settings


Use the following chart when connecting this backplane. If you connect the SAS
ports out of order, you will not able to easily identify drives using the LED function.

SAS Port Connections in I2C and SGPIO Settings

Port # I2C SGPIO


#0-3 I C #1
2
Sideband #1
#4-7 I2C #2 Sideband #2
# 8 - 11 I2C #3 Sideband #3
# 12 - 15 I2C #4 Sideband #4

C-16
Appendix C Backplane Specifications

Front LED Indicators


R194 R324 R325
R105 R246 R459
C89 C86

+
C198
BAR CODE

C200

+ +

JP106
BZ1 1 FAN#1 FAN#2 FAN#3 FAN#4 ALARM#1 ALARM#2 +5V +12V
BUZZER RESET UPGRADE#2 1 JP84 FAIL FAIL FAIL FAIL
+
JP25 D3 D36 D53 D54
C

JP45
1 UPGRADE#1 A CA CA C A C A CA CA

#15
C45

C284
1
D85 D79

JP69
D70 49
49

#3
JP18 C178

48
1

48

C162

#7
#11
J32 J25 J16 J8
C177
C204 C202 C5
C275 C285

C102

C100
+

33
33
17 17
32

+ +
32 R351 C176
R353 C88 Y1
C130

#2
R268 R170 U34
R273 R169
Y2

#10
C229 C158
C159 C139
D73 C245 C121
D69 C122 D66
#14

#6
R249
C148
R458
R455
I2C#4 JP100
U67
1 C173 JP97:FAN#1 SELECT I2C#2 R443 I2C#1
J30 C175 J24 I2C#3 JP52
JP95 J7
JP98:FAN#2 SELECT 1-2:WITH FAN C84
J14 1
C44
C199 C197
1 JP99:FAN#3 SELECT 2-3:NO FAN
+ JP99
C174
JP100:FAN#4 SELECT 1

+ + +

R393
SAS836TQ

JP50
REV 3.2

J29 C170

JP68
1

#9

R332
R222
C226 C155
C227 D83 D72

#5
D61
#13

C171 C29

#1
C172

R314
F3

J23
C267 R338 R339

R308
JP48 1 4

ACT13
ACT14

ACT15
JP63

+
C201
4

1
JP62 4 J12

JP60
C203 C85 C3 J6

+
F16 F15
ACT12 JP58
1
F1

FAN#2

JP26
+ +

JP46

JP13

JP10
C195

JP56 JP47

ACT0

ACT1

ACT2

ACT3
JP61
R437

ACT9

ACT10

ACT11
ACT8

R439
JP54 1 4 1 4
F14

F2
D46 F4 JP64
#12

#4
D60 C23 D55
C79 C80 D64

#0
#8
C258 JP61:FAN#1 SELECT F9
C257 JP62:FAN#2 SELECT ON:WITH FAN
FAN#1 JP63:FAN#3 SELECT OFF:NO FAN
JP64:FAN#4 SELECT
C179

J26 J22 J10 J5

Power LEDS R194


R105
R324
R246
R325
R459
C89 C86

+ FAN#1 FAN#2 FAN#3 FAN#4 ALARM#1 ALARM#2 +5V +12V


FAIL FAIL FAIL FAIL D3 D36 D53 D54
C
UPGRADE#1 A CA CA C A C A CA CA
C45

Fan Failure LEDs Alarm LEDs


JP69

49

#3

48
J8
C5
Figure TQ-4. Front LEDs

33
17
32
C88 Y1
#2

U67
I2C#2 JP95 R443 I2C#1
1 J7
C44

+ Front Pane LEDs


JP68

D61

LED State Specification


C29
#1

Fan #1 Fail On Failure in Fan #1


R314

F3

Fan #2 Fail On Failure in Fan #2


R308

1 4
ACT14

ACT15

JP63
4

JP60

C3 J6
JP58

Fan #3 Fail On Failure in Fan #3


JP26

+
JP10

ACT0

ACT1

ACT2

ACT3
ACT10

ACT11

Fan #4 Fail On Failure in Fan #4


R439

1 4
F4 JP64
D60 C23 D55
#0

Overheat/fan failure/drive failure in Chan-


Alarm #1 On
nel 1
Overheat/fan failure/drive failure in Chan-
Alarm #2 On J5

nel 2
Backplane power failure. Light is on dur-
+5V Off
ing normal operation.
Backplane power failure. Light is on dur-
+12V Off
ing normal operation.

C-17
SC836 Chassis Manual

Rear Connectors and LED Indicators


D15 D24 D28 D87
D8 D29 D33 D88

ACT#11

D87C
D28
C
C

ACT#15
R173
ACT#3

ACT#7
D15

D24

R177
SAS #7 SAS #11 SAS #15

R88

R428
SAS #3

AC

AC

AC
AC
FAIL#11
FAIL#7
FAIL#3

D8

FAIL#15
R178

D29

R435
D33
R90

A
A

A
J4 J15 J20 J31

R182

D88
J4 J15 J20 J31
SAS SAS SAS SAS

D14 D22 D27 D42


#3 #7 #11 #15

D32

D42C
C

ACT#14
D23 D39

ACT#10
C

C
D7

ACT#6
ACT#2

D22

R253
R86

D27
R176
D14

R164
AC

AC

AC
A
C
SAS #6

FAIL#6
SAS #10
FAIL#2

FAIL#10

FAIL#14
SAS #14

D23
SAS #2

D7

D32
R89

R165

R215
R181

A
A

A
J3 J13 J19 J28

D39
SAS

J13
SAS SAS SAS

J3 D13 D21 J19 D26 J28


#2 #6

D41
#10 #14

D41C
D31

C
C

C
D20

ACT#13
ACT#1

ACT#5
D6

ACT#9
D38

D21
D13

R150

D26

R251
R175
R84

AC
AC

AC

AC
FAIL#1

SAS #5 SAS #9

FAIL#5

FAIL#9

FAIL#13
SAS #1 D6

R149

R214
R87

SAS #13

R180
D20
A

A
D31
J2 J11 J18 J27

D38
SAS SAS SAS

J11 J18
SAS

J2
#1

D25 J27
#5 #9

D12 D18 D40


#13

ACT#12

D40C
R250
C

C
C
ACT#0

ACT#8
R83

ACT#4
D30
D12

D25
D18
D5 D19 D37

R174
R95
AC

AC

AC

AC
FAIL#0

FAIL#8
SAS #8

FAIL#4
SAS #0 SAS #12

D19
R96

R179
SAS #4

D30
D5

A
A

A
FAIL#12
R85

J1 J9 J17 J21

R213

D37
SAS SAS SAS SAS

J1
#0

J9
#4

J17 #8

J21 #12

Rear SAS/SATA Connectors

Rear SAS Drive Rear SAS Drive


Connector Number Connector Number
SAS #0 SAS/SATA HHD #0 SAS #8 SAS/SATA HHD #8
SAS #1 SAS/SATA HHD #1 SAS #9 SAS/SATA HHD #9
SAS #2 SAS/SATA HHD #2 SAS #10 SAS/SATA HHD #10
SAS #3 SAS/SATA HHD #3 SAS #11 SAS/SATA HHD #11
SAS #4 SAS/SATA HHD #4 SAS #12 SAS/SATA HHD #12
SAS #5 SAS/SATA HHD #5 SAS #13 SAS/SATA HHD #13
SAS #6 SAS/SATA HHD #6 SAS #14 SAS/SATA HHD #14
SAS #7 SAS/SATA HHD #7 SAS #15 SAS/SATA HHD #15

Rear LED Indicators

Rear LED Hard Drive Activity Failure LED


SAS #0 D12 D5
SAS #1 D13 D6
SAS #2 D14 D7
SAS #3 D15 D8
SAS #4 D18 D19
SAS #5 D21 D20
SAS #6 D22 D23
SAS #7 D24 D29
SAS #8 D25 D30
SAS #9 D26 D31
SAS #10 D27 D32
SAS #11 D28 D33
SAS #12 D40 D37
SAS #13 D41 D38
SAS #14 D42 D39
SAS #15 D87 D88

C-18
Appendix C Backplane Specifications

C-5 BPN-SAS2-836EL Backplane and SAS2 JBOD


Configuration
This manual reflects BPN-SAS2-836EL1 and BPN-SAS2-836EL2 Revision 1.03.

Front Connectors
1
12 1
11 1
10 1
13 19 18 17
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

16

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
12
SEC_J3

OVERHEATFAIL1

12 1 13

C292
1

15
BUZZER_ENB1

1
EC18
+

EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
1
A
ACT18

C
+

U14

14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02

15
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA

BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1

+
EC16 EC11
+

C132 U3

+
14
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

15
C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120
BCA14
20

15
L41
+

J19
+

20
1

+
C227

25
+
+

+
+

C363

28
F3
EC21

EC9
PWR3

+
16
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

16

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8

12
MDIO2 C351

12

+
BCA105 C119
R249 FAN2 4

1
18 1
17
16
SUPER
RR SILKSCREEN UNLESS OTHERWISE
SPECIFIED DIMENSIONS
PRIMARY-SIDE ARE IN INCHES

Figure 2EL-1. Front Connectors


DESINGER: Minh TOLERANCES
DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

1. Primary I2C connector: PRI_I2C1 12. Secondary SAS connector SEC_


J3 (Not available on BPN-SAS2-
2. Power connectors: PWR1, PWR2, 836EL1 backplane)
PWR3 and PWR4
13. Primary UART connector: UART_
3. Primary expander chip P1 (Manufacturer's use only)

4. Secondary expander chip (Not 14. Secondary UART connector:


available on BPN-SAS2-836EL1 UART_S1 (Manufacturer's use
backplane) only, not present on BPN-SAS2-
836EL1 backplane)
5. EPP connectors: J16 and J19
15. P r i m a r y d e b u g c o n n e c t o r :
6. Fan connectors: FAN1, FAN2 and EXPDBG1 (Manufacturer's use
FAN3 only)

7. Primary SAS connector: PRI_J1 16. Secondary debug connector:


EXPDBG2 (Manufacturer's use
8. Primary SAS connector: PRI_J2 only, not present on BPN-SAS2-
836EL1 backplane)
9. Primary SAS connector: PRI_J3
17. Primary MDIO connector: MDIO1
10. Secondary SAS connector: SEC_ (Manufacturer's use only)
J1 (Not available on BPN-SAS2-
836EL1 backplane) 18. Secondary MDIO connector:
MDIO2 (Manufacturer's use only,
11. Secondary SAS connector SEC_ not present on BPN-SAS2-836EL1
J2 (Not available on BPN-SAS2- backplane)
836EL1 backplane)

C-19
SC836 Chassis Manual

Front Connector and Pin Definitions


1. Primary I2C Connector I2C Connector
Pin Definitions
The I2C connector is used to monitor the power
Pin# Definition
supply status and to control the fans. See the
1 Data
table on the right for pin definitions.
2 Ground

3 Clock

4 No Connection

2. Backplane Main Power Connectors Backplane


Main Power
The 4-pin connectors, designated PWR1, 4-Pin Connector
PWR2, PWR3 and PWR4, provide power
Pin# Definition
to the backplane. See the table on the right
1 +12V
for pin definitions.
2 and 3 Ground

4 +5V

3. and 4. Primary and Secondary Expander


Chips
These primary and secondary expander
chips allow the backplane to support dual
ports, cascading, and failover.

5. EPP Ports
The EPP ports are used for manufacturer
diagnostic purposes only.

C-20
Appendix C Backplane Specifications

6. Fan Connectors Fan Connectors

The 4-pin connectors, designated FAN1


Pin# Definition
through FAN3, provide power to the fans.
1 Ground
See the table on the right for pin definitions.
2 +12V

3 Tachometer

4 NC

7. - 12. SAS Connectors


The primary and secondary sets of SAS
connectors provide expander features
including cascading and failover. From right
to left the ports are Primary 1, Primary 2,
Primary 3 and Secondary 1, Secondary 2
and Secondary 3. Note that secondary SAS
ports are not present on the BPN-SAS2-
836EL1 backplane.

13. - 14. UART Connectors


The primary and secondary UART connectors
are for manufacturer's diagnostic purposes
only. (The secondary UART connector is
not present on the SAS2-836EL1 model
backplane)

15. - 16. Debug Connectors


The primary and secondary EXPDBG1
and EXPDBG2 connectors are for
manufacturer's diagnostic purposes only.
(The secondary EXPDBG2 connector is not
present on the BPN-SAS2-836EL1 model
backplane)
17. - 18. MDIO Connectors
The primary and secondary MDIO1 and
MDIO2 connectors are for Supermicro's
internal use only. (The secondary MDIO2
connector is not present on the BPN-SAS2-
836EL1 model backplane)

C-21
SC836 Chassis Manual

Front Jumper Locations and Settings

SEC_MODE1 PRI_MODE1 ACTLED1 FAN_MONITOR_


SEC_MODE2 PRI_MODE2 DISABLE
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3
OVERHEATFAIL1

C292
1

FANFAIL_LED_DIS-
BUZZER_ENB1

EC18
+

EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A
ACT18

C
+

U14

+
+

ABLE
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367

BUZZER_
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA

BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1

+
EC16 EC11

ENB1
+ C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120
BCA14
20

15
L41
+

J19
+

20
1

+
C227

25
+
+

+
C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE
SPECIFIED DIMENSIONS
PRIMARY-SIDE ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Figure 2EL-2. Front Jumper Locations and Settings

General Jumper Settings

Jumper Jumper Settings Note

Factory setting
PRI_MODE1 and 2 Pin 2-3
Do not change
Factory setting
SEC_MODE1 and 2 Pin 2-3
Do not change
Open: Disabled (Default)
BUZZER_ENB1 Buzzer settings*
Closed: Enabled
Open: Disabled (Default) Activity LED testing
ACTLED1
Closed: Enabled (Supermicro internal use only)
Open: Enabled
FAN_LED_DISABLE Turns off the FANFAIL1 LED
Closed: Disabled (Default)
FAN_MONITOR_ Open: Enabled (Default)
Turns off fan speed reporting
DISABLE Closed: Disabled

*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by one of the following conditions:

1. Hard drive failure.

2. Fan failure.

3. System temperature over 45º Celsius.

C-22
Appendix C Backplane Specifications

Explanation of Jumpers
3 2 1
To modify the operation of the backplane, Connector
Pins
jumpers can be used to choose between
optional settings. Jumpers create shorts
between two pins to change the function
of the connector. Pin 1 is identified with Jumper

a square solder pad on the printed circuit


board. Note: On two pin jumpers, "Closed"
3 2 1
means the jumper is on and "Open" means
Setting
the jumper is off the pins.

C-23
SC836 Chassis Manual

Front LEDs

12V_LED1
5V_LED1
OVERHEATFAIL1
FANFAIL1
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1

C292
1

ACT18 ACT17
BUZZER_ENB1

EC18
+

EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A
ACT18

C
+

U14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA

BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1

+
EC16 EC11
+

C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120
BCA14
20

15
L41
+

J19
+

20
1
+

+
C227

25
+
+

+
+

C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
+ C212
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE
SPECIFIED DIMENSIONS
PRIMARY-SIDE ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Figure 2EL-3. Front LEDs

Front LEDs

LED Active State Specification


FANFAIL1 On Fan failure
5V_LED1 On 5V power on LED
12v_LED1 On 12V power on LED
ACT17 On Primary Ethernet Tx activity LED
ACT18 On Secondary Ethernet Tx activity LED
Overheat/Drive Failure LED Indicator
OVERHEATFAIL1 On
(Red light: flashing, buzzer: on)

C-24
Appendix C Backplane Specifications

Rear Connectors and LED Indicators

ACT15
ACT#15
ACT7
ACT#7
ACT3
ACT#3
C C

R65

C
C ACT#11
ACT11 R81

A A A

A
C

FAIL3

FAIL11
FAIL#11
C C C

FAIL7
FAIL#7
A A A

SAS #3 SAS #11


A

SAS #7
PRI_FLASH1

SAS #15

FAIL#15
FAIL15
J3 C272 R67 J7 J11 J15
1 4

C7
SAS SAS SAS SAS

ACT#14
ACT14
ACT#10
#3 #11 #15

ACT10
#7

ACT#2
ACT2
SEC_FLASH1
C
C C C

ACT6
ACT#6
FAIL2
FAIL#2
A A A
C A C
C C

FAIL#10
FAIL10
FAIL6
FAIL#6
SAS #10 SAS #14
A A A
A

SAS #2
U2
C147

C148

J6 J10

SAS #6
J2 J14

FAIL#14
FAIL14
BCA41
SAS
#6
SAS
#2 SAS SAS

ACT#13
#10 #14

ACT13
C140
C136

ACT9
ACT#9
A
ACT1
ACT#1

C C C

ACT5
ACT#5
C

A A A
A C C C
C

FAIL5
FAIL#5
SAS #1 SAS #9
A A A
A

SAS #5 SAS #13


SAS
FAIL1
FAIL#1

FAIL9
FAIL#9
C135

C139

C145

C146

FAIL13
J1 J5 J9 #13
J13

FAIL#13
SAS SAS
#1 #5
SAS

RA4
LA2
#9
BCA7

ACT12
ACT0
ACT#0

ACT#12
C C
C

ACT4
ACT#4
C

ACT#8
ACT8
A A A A
C C
C C

FAIL4
FAIL#4

FAIL8
FAIL#8
FAIL0
FAIL#0

A A
C143
C144

SAS #0 SAS #8
A A
C138

C141

SAS #4 SAS #12


J0 J4 J8
SAS2-836EL2 U8
J12

REV1.02 SAS
#0 SAS SAS SAS
#4 #8 #12

REPUS
ESIWREHTO SSELNU SILKSCREEN
RR
SNOISNEMID DEIFICEPS
SECONDARY-SIDE

Figure 2EL-4. Rear Connectors


SEHCNI NI ERA

SECNARELOT hniM :REGNISED


.A.S.U ORCIMREPUS YB DENGISED
ELGNA LAMICED moc.orcimrepus.www
03 1. X 20.1 :VER 82 50 0102 :ETAD
HSINIF HCAM 30. XX 13159 AC,ESOJ NAS
010X. XX 2LE638-2SAS-NPB :EMAN TCEJ8O00R8P-305-804:XAF 0008-305-804:LET

Rear SAS/SATA Connectors

Rear
SAS/SATA Drive Number
Connector
SAS #0 SAS/SATA HDD #0
SAS #1 SAS/SATA HDD #1
SAS #2 SAS/SATA HDD #2
SAS #3 SAS/SATA HDD #3
SAS #4 SAS/SATA HDD #4
SAS #5 SAS/SATA HDD #5
SAS #6 SAS/SATA HDD #6
SAS #7 SAS/SATA HDD #7
SAS #8 SAS/SATA HDD #8
SAS #9 SAS/SATA HDD #9
SAS #10 SAS/SATA HDD #10
SAS #11 SAS/SATA HDD #11
SAS #12 SAS/SATA HDD #12
SAS #13 SAS/SATA HDD #13
SAS #14 SAS/SATA HDD #14
SAS #15 SAS/SATA HDD #15

C-25
SC836 Chassis Manual

Rear LED Indicators

Rear Connector Hard Drive Activity LED Failure LED


SAS #0 ACT #0 FAIL #0
SAS #1 ACT #1 FAIL #1
SAS #2 ACT #2 FAIL #2
SAS #3 ACT #3 FAIL #3
SAS #4 ACT #4 FAIL #4
SAS #5 ACT #5 FAIL #5
SAS #6 ACT #6 FAIL #6
SAS #7 ACT #7 FAIL #7
SAS #8 ACT #8 FAIL #8
SAS #9 ACT #9 FAIL #9
SAS #10 ACT #10 FAIL #10
SAS #11 ACT #11 FAIL #11
SAS #12 ACT #12 FAIL #12
SAS #13 ACT #13 FAIL #13
SAS #14 ACT #14 FAIL #14
SAS #15 ACT #15 FAIL #15

C-26
Appendix C Backplane Specifications

Single and Dual Port Expanders

Single Ports
BPN-SAS2-836EL1 backplanes have a single-port expander that accesses all hard
drives and supports cascading.

Dual Ports
BPN-SAS2-836EL2 backplanes have dual-port expanders that access all the
hard drives. These dual-port expanders support cascading, failover, and multipath
functionality.

From HBA or higher From HBA or higher


backplane backplane
J2
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3

J1
+

R284

J2
MH1 MH9 4 4 MH6
+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1

+
FAN_MONITOR_DISABLE
+

3 3
PRI_J1

ACTLED1 J1
L1

JP106
3

1
Q3

1 C C
+

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A
PRI_I2C1
R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18
+

EC3
+

BCA185

EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120

BCA14
20

L41 15
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9
PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE
SPECIFIED DIMENSIONS
PRIMARY-SIDE ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
DECIMAL ANGLE

Secondary
www.supermicro.com DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: XXX.010

Primary ports
TEL:408-503-8000 FAX:408-503-8008 BPN-SAS2-836EL2

ports To lower To lower Expander 1


Expander 2 backplane backplane
in cascaded in cascaded
system system

From HBA or higher


backplane
J1
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 C154

J0
3
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE
SPECIFIED DIMENSIONS
PRIMARY-SIDE ARE IN INCHES

Primary ports
DESINGER: Minh TOLERANCES
DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Expander 1
To lower backplane in
cascaded system

Figure 2EL-5. Dual Port Cascading Configurations

C-27
SC836 Chassis Manual

Failover

The BPN-SAS2-836EL2 backplane has two expanders which allow effective failover.

SAS HBA
Single Host Bus
Adapter
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3

+
MH1 R284 MH9 4 4 MH6

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
In a single host bus configuration, the

Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3
OVERHEATFAIL1

C292
1

BUZZER_ENB1
EC18

+
EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A

ACT18

C
+
U14

+
+

+
BPN-SAS2-836EL2
3 3 4 4
MH10 MH5

C367
C259
REV 1.02
B

+
SEC_MODE2
SEC_MODE1
DESIGNED IN USA

BCA64
C352

+
1

backplane connects to one Host Bus

EXPDBG2
UART_S1
C366
C361
PWR4
WWN
1 1

BAR CODE

AH

AE
WWN

E
PWR1

+
EC16 EC11

+
C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402
C121
+5V GND GND +12V

EC27
10

5
EC19

+
+
D4

15

10
+
C262

C120
BCA14

20

15
L41

+
J19

20
1

+
C227

25
+
+
Adapter (HBA).
+

+
C363

28
F3

EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

Secondary ports
DESINGER: Minh

Primary ports
DESIGNED BY SUPERMICRO U.S.A. TOLERANCES
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Expander 2 Expander 1

SAS HBA
Single Host Bus Adapter
Failover U18 EC1 SEC_J2 SEC_J1 PRI_J3
PRI_J2
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1

+
FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1

JP106
3

1
Q3

1 C C
+

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1

If the expander or data path in Port A


SEC_J3

OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18
+

EC3
+

BCA185

EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

fails, the system automatically switches


5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19

+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121

to Port B.
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE

Secondary ports
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH

Primary ports
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Expander 2 Expander 1

Figure 2EL-6. Single and Dual HBAs

C-28
Appendix C Backplane Specifications

Failover with RAID Cards and Multiple HBAs


The BPN-SAS2-836EL backplane may be configured for failover with multiple HBAs
using either RAID controllers or HBAs to achieve failover protection.

RAID Controllers: If RAID controllers are used, the failover is accomplished through
port failover on the same RAID card.

HBAs: If multiple HBAs are used to achieve failover protection and load balancing,
Linux MPIO software must be installed and correctly configured to perform
the load balancing and failover tasks.

Dual Host Bus


Adapter SAS HBA

In a dual host bus configuration, SAS HBA


the backplane connects to two
HBAs.
PRI_J2
PRI_J1

SEC_J0 SEC_J1
SEC_J2

PRI_J0

Port B Port A
Expander 2 Expander 1

Figure 2EL-7. Dual HBA

Dual Host Bus Adapter SAS HBA


Failover
If the expander or data path in Port SAS HBA
A fails, the system automatically
switches to Port B. This maintains a full SEC_J2
SEC_J0 SEC_J1
PRI_J2
PRI_J1

PRI_J0

connection to all drives.


Port B Port A
Expander 2 Expander 1

Figure 2EL-7. Dual HBA Failover

IMPORTANT: For RAID controllers, redundancy is achieved through port failover.


For multiple HBAs MPIO software is required to achieve failover protection.

C-29
SC836 Chassis Manual

SAS2 JBOD Configuration with BPN-SAS2-836EL

In a cascaded configuration, the first chassis (head node) includes a motherboard


and at least one host bus adapter (HBA). The SC836 chassis with 836EL backplane
can be configured as JBOD with a JBOD control board. This section describes the
supported JBOD control board for the BPN-SAS2-836EL series backplanes.

4 1 4 1 4 1 4 1
FAN4 FAN3 FAN1
R4 FAN2
MH1
R3 F3 R2 R1 MH2

F2
F4

F1
1

FAN5/X J1
J13

+
1 F5
C1

24
12
U1

EC2
U2
R5

C3
4

+
FAN6/X U4
1 R18
F7 U6 D314

EC3
+
C4
R22

+
U3
R6

BUZZER1 U9
U8

EC1
FAN7/X R94
C2

1 C33
F8
R93
U92 R23 R13
R92 D1
C35 R70 A C
R24

C36
R7

4 C22
C659

BAR CODE
R20
R17

R31
Q1
+

FAN8/X D315 D316


U7

13
1

1
F9

C37
C39 C38
J17
R8

R19

JP7

CSE-PTJBOD-CB2
4
R21

1 5
R14

R15

R16

REV 1.01 JF1


R12

R11

I2C 2 20

1 19

MH3 HDD PWR


3 2 1 PWR PWR OH
NIC2

NIC1
RST

X NMI MH4
ON FAIL /FF LED LED

Figure 2EL-8. CB2 JBOD Control Board (Sold Separately)

Power Card
Part Number Part Type Where Used
Allows the chassis to be used as
CSE-PTJBOD-CB2 JBOD Control Board a JBOD (Just a Bunch of Drives)
system.

C-30
Appendix C Backplane Specifications

Connecting an Internal Host Bus Adapter to the Backplane


The following section lists the most common cables used to connect the host bus
adapter to the backplane.

HBA

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3
OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18
+

EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A
ACT18

C
+

U14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA

BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1

+
EC16 EC11
+

C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120
BCA14
20

15
L41
+

J19
+

20
1

+
C227

25
+
+

+
+

C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

HBA HBA

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Figure 2EL-9. Connecting an Internal HBA to the Backplane

IMPORTANT: See Section 3-3 of this manual, Failover with RAID Cards and Multiple
HBAs for important information on supported configurations.

Supported Internal HBA Cables


Use the following cables to create connections between the internal HBA and SAS2-
836EL backplane. The cables required depend upon the HBA connector.

Cable Name: iPass to 4-lane


Part #: CBL-0117L Length: 46 cm (18 inches)
Description: This cable has one SFF-8484 (32-pin) connector on one end and one
iPass (SFF-8087/Mini-SAS) connector (36-pin) at the other. This cable connects
from the HBA to the BPN-SAS2-836EL backplane.

C-31
SC836 Chassis Manual

Cable Name: iPass (Mini-SAS) to iPass (Mini-SAS)


Part #: CBL-0108L-02 Length: 39 cm (15 inches)
Part #: CBL-0109L-02 Length: 22 cm (9 inches)
Part #: CBL-0110L-02 Length: 18 cm (7 inches)

Description: This cable has an iPass (SFF-8087/Mini-SAS) connector (36-pin) at


each end. It connects from the HBA to the SAS2-836EL backplane.

C-32
Appendix C Backplane Specifications

Connecting an External Host Bus Adapter to the Backplane


This backplane supports external host bus adapters. In this configuration, the
HBA and the backplane are in different physical chassis. This allows a JBOD
configuration system to connect to another system that has an HBA.

Single External Host Bus Adapter


PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3

+
MH1 R284 MH9 4 4 MH6

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3
OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18

+
EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A

ACT18

C
+
U14

+
+

+
BPN-SAS2-836EL2
3 3 4 4
MH10 MH5

C367
C259
REV 1.02
B

+
SEC_MODE2
SEC_MODE1
DESIGNED IN USA

BCA64
C352

+
1

EXPDBG2
UART_S1
C366
C361
PWR4
WWN
1 1

BAR CODE

AH

AE
WWN

E
PWR1

+
EC16 EC11

+
C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4

15

10
+
C262

C120
BCA14

20

15
L41

+
J19
+

20
1

+
C227

25
+
+
+

+
C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

JBOD Control Board

HBA

CBL-0200L
External HBA Cable

Dual External Host Bus Adapter

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

JBOD Control Board

HBA

HBA
CBL-0200L
External HBA Cables

Figure 2EL-10. Connecting Single and Dual HBAs to the Backplane

IMPORTANT: See Section C-12 of this manual, Failover with RAID Cards and
Multiple HBAs for important information on supported configurations.

C-33
SC836 Chassis Manual

Supported External HBA to Backplane Cable


Use the following cable if your external HBA has an InfiniBand connector.

Figure 2EL-11. External Cable (CBL-0166L)

Cable Name: SAS EL2/EL1 Cascading Cable (External), 68 cm


Part #: CBL-0166L (SFF-8088 1x to SFF-8088 x1)
Ports: Single or Dual
Placement: External cable
Description: External cascading cable. Connects ports between servers. With most
connectors, use one cable for single port connections and two cables for dual port
connections.

C-34
Appendix C Backplane Specifications

Connecting Multiple Backplanes in a Single Channel


Environment
This section describes the cables used when cascading from a single HBA. These
connections use CBL-0167L internal cables and CBL-0166L external cables.

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18
+

EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A
ACT18

C
+

U14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA

BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1

+
EC16 EC11
+

C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120
BCA14
20

15
CBL-0167L
L41
+

J19
+

20
1
+

+
C227

25
+
+

+
+

C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212
+

EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8

with Single Port Assembly


MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

(Internal cable)
PRIMARY-SIDE SPECIFIED DIMENSIONS
ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1

HBA

CBL-0166L
(External cable)
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1

JBOD Control
Board

Figure 2EL-12. Single HBA Configuration

C-35
SC836 Chassis Manual

Single HBA Configuration Cables

Single Port Cable


Assembly

Figure 2EL-13. Single Port Internal Cable (CBL-0167L)

Cable Name: SAS EL2/EL1 Backplane Cable (Internal) with 2-port Cascading Cable,
68 cm
Part #: CBL-0167L (SFF-8087 to SFF-8088 x1)
Ports: Single
Placement: Internal cable
Description: Internal cable. Connects the backplane to the HBA or external port.
Used in single port environments.

Figure 2EL-14. External Cable (CBL-0166L)


Cable Name: SAS EL2/EL1 Cascading Cable (External), 68 cm
Part #: CBL-0166L (SFF-8088 1x to SFF-8088 x1)
Ports: Single or Dual
Placement: External cable
Description: External cascading cable. Connects ports between servers. With most
connectors, use one cable for single port connections and two cables for dual port
connections.

C-36
Appendix C Backplane Specifications

Connecting Multiple Backplanes in a Dual Channel


Environment
This section describes the cables used when cascading from dual HBAs. These
connections use CBL-0168L internal cables and CBL-0166L external cables.

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18
+

EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A
ACT18

C
+

U14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA

BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1

+
EC16 EC11
+

C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120
BCA14
20

15
L41
+

J19
+

20
1
+

+
C227

25
+
+

+
+

C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS

Cable 0168L
ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

with Single Port Assembly


Secondary Port Primary Port (Internal cable)
Expander 2 Expander 1

HBA

HBA

Cable 0166L
(External cable)
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Primary
Port Port
Expander 2 Expander 1

JBOD Control
Board

Figure 2EL-15. Multiple Backplanes in a Dual Channel Environment

IMPORTANT: See Section C-12 of this manual, Failover with RAID Cards and
Multiple HBAs for important information on supported configurations.

C-37
SC836 Chassis Manual

Dual HBA Configuration Cables

Dual Port Cable


Assembly

Figure 2EL-16. Dual Port Internal Cable (CBL-0168L)

Cable Name: SAS Dual-port Cable Assembly, 68/76 cm


Part #: CBL-0168L Placement: Internal cable
Ports: Dual
Description: Internal cascading cable. Connects the backplane to the HBA or
external port. Used in dual port environments.

Figure 2EL-17. External Cable (CBL-0166L)

Cable Name: SAS EL2/EL1 Cascading Cable (External), 68 cm


Part #: CBL-0166L Placement: External cable
Ports: Single or Dual
Description: External cascading cable. Connects ports between servers. Use one
cable for single port connections and two cables for dual port connections.

C-38
Appendix C Backplane Specifications

Supported Cascading Configurations


Cascading allows the system to access data at a faster rate by allowing several
backplanes to share resources to reduce latency time.
The first backplane in a cascaded system requires a motherboard and an HBA.
Other servers require a JBOD Control Board but with no motherboard and no HBA.

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18
+

EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A
ACT18

C
+

U14
+

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA

BCA64
C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1

+
EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

5
EC19

+
+

D4
15

10
+
C262

C120
BCA14
20

15
L41
+

J19
+

20
1
+

+
C227

25
+
+

+
+

C363

28
F3
EC21

EC9
PWR3

+
MDIO1
+

GND
+
+5V GND GND +12V +5V GND +12V

C133
+

C212
+

EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
XX .03

Single Port Cable


SAN JOSE,CA 95131 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port Assembly


Expander 2 Expander 1
HBA

Cable 0167L
(Internal cable)

Cable 0166L
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1

(External cable)
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Cable 0167L
Secondary Port Primary Port (Internal cable)
Expander 2 Expander 1

JBOD Control Board

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1

JBOD Control Board

Figure 2EL-18. Simple Cascaded Configurations

C-39
SC836 Chassis Manual

HBA
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3

+
MH1 R284 MH9 4 4 MH6

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3
OVERHEATFAIL1

C292
1

BUZZER_ENB1
EC18

+
EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A

ACT18

C
+
U14

+
+

+
BPN-SAS2-836EL2
3 3 4 4
MH10 MH5

C367
C259
REV 1.02
B

+
SEC_MODE2
SEC_MODE1
DESIGNED IN USA

BCA64
C352

+
1

EXPDBG2
UART_S1
C366
C361
PWR4
WWN
1 1

BAR CODE

AH

AE
WWN

E
PWR1

+
EC16 EC11

+
C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402
C121
+5V GND GND +12V

EC27
10

5
EC19

+
+
D4

15

10
+
C262

C120
BCA14

20

15
L41

+
J19
+

20
1

+
C227

25
+
+
+

+
C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Primary Port
Expander 1

Cable 0167L
(Internal cable)

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

1
Q3

1 C C
+

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Primary Port
Expander 1
JBOD Control
Board

Cable 0166L
(External cable)

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Primary Port
Expander 1
JBOD Control
Board

Figure 2EL-19. Cascaded Configuration with Horizontal Branching

C-40
Appendix C Backplane Specifications

Dual SAS HBA and Cascaded Configuration


IMPORTANT: See Section 3-3 of this manual, Failover with RAID Cards and Multiple
HBAs for important information on supported configurations.
HBA HBA

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+
MH1 R284 MH9 4 4 MH6

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3
OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18

+
EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A

ACT18

C
+

U14

+
+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B

+
SEC_MODE2
SEC_MODE1
DESIGNED IN USA

BCA64
C352
+

EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE
WWN
Y

E
PWR1

+
EC16 EC11

+
C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4

15

10
+
C262

C120
BCA14

20

15
L41

+
J19
+

20
1

+
C227

25
+
+

+
C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1
Dual Port Cable
Assembly

Cable 0168L
(Internal cable)

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4

Cable 0166L
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+

(External cables)
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1
JBOD Control Board

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1

JBOD Control Board

Figure 2EL-20. Dual SAS HBA with Cascaded Configuration

C-41
SC836 Chassis Manual

Dual SAS HBA Cascaded Configuration with Branching

IMPORTANT: See Section of this manual, Failover with RAID Cards and Multiple
HBAs for important information on supported configurations.

HBA HBA
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3

+
MH1 R284 MH9 4 4 MH6

JP105
FANFAIL_LED_DISABLE MH4

+
EC15 1

+
FAN_MONITOR_DISABLE

+
3 3
PRI_J1

ACTLED1
L1

JP106
3

1
Q3

+
1 C C

1
C421 3 C154
EC20
A EC5 C182 A A

FANFAIL1
4 A C
1

5V_LED1

12V_LED1
JP1
EC12 1 1 1
C A

PRI_I2C1
R162

PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3
OVERHEATFAIL1

C292
1
BUZZER_ENB1

EC18

+
EC3

+
BCA185

EC10
+

A
EC22

ACT17
EC14
A

ACT18

C
+
U14

+
+

+
BPN-SAS2-836EL2
3 3 4 4
MH10 MH5

C367
C259
REV 1.02
B

+
SEC_MODE2
SEC_MODE1
DESIGNED IN USA

BCA64
C352

+
1

EXPDBG2
UART_S1
C366
C361
PWR4
WWN
1 1

BAR CODE

AH

AE
WWN

E
PWR1

+
EC16 EC11

+
C132 U3

+
C411 +5V GND GND +12V C134

AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V

EC27
10

5
EC19

+
+

D4

15

10
+
C262

C120
BCA14

20

15
L41

+
J19
+

20
1

+
C227

25
+
+
+

+
C363

28
F3
EC21

EC9
PWR3

+
MDIO1

+
GND

+
+5V GND GND +12V +5V GND +12V

C133
+
C212

+
EC28 EC26 1 FAN3

+
PWR2 C353 C365 BCA160
BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351

+
BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1

PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1

JBOD Control
Board

Cable 0166L
(External cable)
PRI_J2
U18 EC1 SEC_J2 SEC_J1 PRI_J3
+

MH1 R284 MH9 4 4 MH6


+

JP105

FANFAIL_LED_DISABLE MH4
+

EC15 1
+

FAN_MONITOR_DISABLE
+

3 3
PRI_J1
ACTLED1

L1
JP106

3
1
Q3

1 C C
+

C421 3 C154
EC20
A EC5 C182 A A
FANFAIL1

4 A C
1
5V_LED1

12V_LED1

JP1
EC12 1 1 1
C A
PRI_I2C1

R162
PRI_MODE2
PRI_MODE1
EXPDBG1

UART_P1
SEC_J3

OVERHEATFAIL1
C292

1
BUZZER_ENB1

EC18
+

EC3
+

BCA185
EC10
+

A
EC22

ACT17
EC14

A
ACT18

C
+

U14
+

+
+

BPN-SAS2-836EL2
3 3 4 4
MH10 MH5
C367
C259

REV 1.02
B
+
SEC_MODE2
SEC_MODE1

DESIGNED IN USA
BCA64

C352
+

1
EXPDBG2
UART_S1
C366

C361
PWR4
WWN
1 1

BAR CODE
AH

AE

WWN
Y

PWR1
+

EC16 EC11
+

C132 U3
+

C411 +5V GND GND +12V C134


AH

AE

E
5

EC7
+
C402

C121
+5V GND GND +12V
EC27
10

EC19
+
+

D4
15

10
+
C262

C120

BCA14
20

15

L41
+

J19
+

20

1
+

+
C227

25
+
+

+
+

C363
28

F3
EC21

EC9

PWR3
+

MDIO1
+

GND
+

+5V GND GND +12V +5V GND +12V


C133
+

C212
+

EC28 EC26 1 FAN3


+

PWR2 C353 C365 BCA160


BCA115 BCA111 BCA172 EC17 MH12 L121
1 FAN1 4 L18 BCA26 1 4 2 1
MH3 C60
C129 1 J16

MH8
MDIO2 C351
+

BCA105 C119
R249 FAN2 4

SUPER
RR SILKSCREEN UNLESS OTHERWISE

PRIMARY-SIDE SPECIFIED DIMENSIONS


ARE IN INCHES

DESINGER: Minh TOLERANCES


DESIGNED BY SUPERMICRO U.S.A.
www.supermicro.com DECIMAL ANGLE
DATE: 2010 05 28 REV: 1.02 X .1 30
SAN JOSE,CA 95131 XX .03 MACH FINISH
PROJECT NAME: BPN-SAS2-836EL2 XXX.010
TEL:408-503-8000 FAX:408-503-8008

Secondary Port Primary Port


Expander 2 Expander 1

JBOD Control
Board

Figure 2EL-21. Dual SAS HBA with Cascaded Configuration and Branching

C-42
Appendix C Backplane Specifications

C-6 BPN-SAS3-836EL Backplane and SAS3 JBOD


Configuration
This manual reflects BPN-SAS3-836EL1 and BPN-SAS3-836EL2 Revision 1.01.

Front Connectors

9 7
MH1 MH13 MH5 MH6 MH4

11
S_ICE_HDR P_SDB 1 2 3
L2

3
J37 2 20 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9

+
19 EC19 EC20 EC2
+

1
J33

L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
2

D7
D8
C7
C8
B7
B8
CG2 L10 L7

3
CG3 CG1
L5 DESIGNED IN USA

PRESS FIT
CG1

OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1
SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

2
B1

A1

J17 A P_MDIO CG3 CG1


CG2

3
MH2 C

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8

PRESS FIT
+

+
WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR

J22
CG3 CG1 PRI_I2C1
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

10
WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2
PRI_J2

D1
L6 1 C21 CG2

12
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

5 6
CG2
HS1

3
CG3 AF
CG1 AE

2
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

8
Y CG3 CG1
26
25

D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT
EC13 EC14
+

EC12

+
4
EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0

J21
C1

B1

A1

F3

F7
20
CG2
S_HB_LED U1

D2
C1

C2

B2
A1
A2
B1
K

D1
S_SDB PRI_J1
A C
J36 1 4 15 CG2
J35 Y2 PWR2
S_UART 1 4
E

1 2
10 CG3 CG1
A

A7
D7
D8

C8

B8

A8
C7

B7
H E A

PRESS FIT
H E A
26 25 20 15 10 5 1
5

J20
11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4

D1
D2
C1
C2
B1
B2
A1
A2
11 J34
+

2 EC6 EC5

+
S_JTAG P_MDIO 2 8
55

F1
J29 9 L1
EC18

MH9 J27
MH3 MH12 1

1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Figure 3EL-1. Front Connectors

1. Power connectors: PWR1, PWR2, 6. I2C connector: PRI_I2C1 (4-pin)


PWR3 and PWR4 (4-pin)
7. Primary UART connector: UART_
2. Primary SAS connectors: PRI_J0 P1 (J19; 4-pin)
(J20), PRI_J1 (J21), PRI_J2 (J22),
and PRI_J3 (J23) 8. Secondary UART connector:
UART_S1 (J35; 4-pin)
3. Secondary SAS connectors: SEC_
J0 (J30), SEC_J1 (J31), SEC_J2 9. Primary SDB (J24, 4-pin)
(J32), and SEC_J3 (J33)
10. Secondary SDB (J36, 4-pin)
4. Primary expander chip
11. SMB connector: JBOD controller
5. Secondary expander chip (J17, 4-pin)

12. Overheat_Fail2 (2-pin)

C-43
SC836 Chassis Manual

Front Connector and Pin Definitions


1. Backplane Main Power Connectors Backplane
Main Power
The 4-pin connectors, designated PWR1, 4-Pin Connector
PWR2, PWR3 and PWR4, provide power
Pin# Definition
to the backplane. See the table on the right
1 +12V
for pin definitions.
2 and 3 Ground

4 +5V

2-3. SAS Connectors


The primary and secondary sets of SAS connectors provide expander features
including cascading and failover.

4-5. Expander Chips


These primary and secondary expander chips allow the backplane to support
dual ports, cascading, and failover.

6-10. I2C Connector, UART Connectors, SDB Connectors


The I2C connector, the UART connectors, and the SDB connectors are for manu-
facturing diagnostic purposes only.
11. SMB Connector
This header provides for a connection with an optional JBOD controller board.

12. OVERHEAT_FAIL2 Connector


This header can be connected to an external overheat LED, if desired.

C-44
Appendix C Backplane Specifications

Front Jumper Locations and Settings

ACTLED1

MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9

+
19 EC19 EC20 EC2

+
1
J33

L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8
CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA

PRESS FIT
CG1

OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1
SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER

+
EC15 2 EC3 EC4 J28
+

4 EC7 EC8

PRESS FIT
+

+
WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR

J22
CG3 CG1 PRI_I2C1
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2
PRI_J2

D1
L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

CG3 AF
CG1 AE
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1
26
25

D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT
EC13 EC14
+

EC12

+
EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0

J21
C1

B1

A1

F3

F7
20
CG2
S_HB_LED U1

D2
C1

C2

B2
A1
A2
B1
K

D1
S_SDB PRI_J1
A C
J36 1 4 15 CG2
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A

A7
D7
D8

C8

B8

A8
C7

B7
H E A

PRESS FIT
H E A
26 25 20 15 10 5 1
5

J20
11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4

D1
D2
C1
C2
B1
B2
A1
A2
11 J34
+

2 EC6 EC5

+
S_JTAG P_MDIO 2 8
55

F1
J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Figure 3EL-2. Front Jumper Locations and Settings

General Jumper Settings

Jumper Jumper Settings Note

Open: Disabled (Default) Activity LED testing


ACTLED1
Closed: Enabled (Supermicro internal use only)

Explanation of Jumpers
3 2 1
To modify the operation of the backplane, Connector
Pins
jumpers can be used to choose between
optional settings. Jumpers create shorts
between two pins to change the function
of the connector. Pin 1 is identified with Jumper

a square solder pad on the printed circuit


board. Note: On two pin jumpers, "Closed"
3 2 1
means the jumper is on and "Open" means
Setting
the jumper is off the pins.

C-45
SC836 Chassis Manual

Front LED Indicators

S_HB_LED Overheat_Fail1 P_HB_LED 5V_LED1 12V_LED1

MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9

+
19 EC19 EC20 EC2

+
1
J33

L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8
CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA

PRESS FIT
CG1

OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1
SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8

PRESS FIT
+

+
WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR

J22
CG3 CG1 PRI_I2C1
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2
PRI_J2

D1
L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

CG3 AF
CG1 AE
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1
26
25

D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT
EC13 EC14
+

EC12

+
EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0

J21
C1

B1

A1

F3

F7
20
CG2
S_HB_LED U1

D2
C1

C2

B2
A1
A2
B1
K

D1
S_SDB PRI_J1
A C
J36 1 4 15 CG2
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A

A7
D7
D8

C8

B8

A8
C7

B7
H E A

PRESS FIT
H E A
26 25 20 15 10 5 1
5

J20
11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4

D1
D2
C1
C2
B1
B2
A1
A2
11 J34
+

2 EC6 EC5

+
S_JTAG P_MDIO 2 8
55

F1
J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Figure 3EL-3. Front LEDs

Front LEDs

Normal
LED Specification
State
S_HB_LED Blinking Secondary expander heartbeat indicator

OVERHEAT_FAIL1 Off System overheat


P_HB_LED Blinking Primary expander heartbeat indicator

5V_LED1 On 5V power LED


12v_LED1 On 12V power LED

C-46
Appendix C Backplane Specifications

Rear Connectors and LED Indicators

ACT#15
ACT15
ACT11
ACT#11
ACT3
ACT#3
C C C
C

ACT7
ACT#7

FAIL11
FAIL#11
A A A A
C

FAIL3
FAIL#3
C
C C

CG1

CG3
FAIL7
FAIL#7

B8
B7
C8
C7
A7
A A

D8
D7
A8
SAS #3
A

SAS #11
A SAS

SAS #7 SAS #15

FAIL15
#15

S14
S8

P1

S14
S8 S14 J11 S8

P1

P1
S1 J3 S8
S7 P1 P15 S1 J7 P15 S1 S7 P15 S1 J15 S7 P15

A2

B2

C2

D2
D1
A1

B1

C1
CG1

CG3

CG2
SAS SAS
B8
B7
C8
C7

#11
A7

#7
D8
D7
A8

SAS
#3

CG1

CG3

ACT#14
ACT14
ACT#2
ACT2

B8
B7
C8
C7
A7

D8
D7
A8
ACT10
C
A2

B2

C2

D2

FAIL2
FAIL#2
D1

C C C
A1

B1

C1

ACT6
ACT#6
CG2

A A

FAIL10
FAIL#10
A A
C

A2

B2

C2

D2
C

D1
A1

B1

C1
C C
CG1

CG3

FAIL6
FAIL#6

CG2
SAS #10 SAS #14
B8
B7
C8
C7

A
A7

A A
D8
D7
A8

SAS A

SAS #2

CG1

CG3
#14

S14
SAS #6

FAIL#14
FAIL14
S14
S8 S8 J14

S14
J2

P1

P1
J10
S1 S1 J6 S8

B8
B7
C8
C7
P15 S7 P15 S1 S7 P15 S1

A7
S7 P15

D8
D7
A8
A2

B2

C2

D2

SAS
D1
A1

B1

C1

#6
CG2

SAS
#2 SAS
#10

A2

B2

C2

D2
D1
A1

B1

C1

ACT#13
ACT13
CG2
ACT#9
ACT1
ACT#1

ACT9
C C

CG1

CG3
ACT5
ACT#5
C
C

B8
B7
C8
C7
A7
FAIL#9
FAIL9

D8
D7
A8
A A A A
C C C
CG1

CG3

FAIL5
FAIL#5
B8
B7
C8
C7
A7

D8
D7
A8

SAS #1 SAS #9
A A

A2

B2

C2

D2
A

SAS #5

D1
SAS #13
SAS
FAIL1
FAIL#1

A1

B1

C1

FAIL#13
FAIL13
#13

CG2
J1 S7 S14 J5 S14 S8 S14

S14
S1 S1 J9 J13
S8 S1 S7 S8 S7 S8

P1
P1 P15 P1 P15 S7 P1 P15 S1 P15
A2

B2

C2

D2
D1
A1

B1

C1

SAS
CG2

#1
SAS
#5 SAS
#9
CG1

CG3

LT8

ACT#12
ACT12
B8
B7
C8
C7
A7

D8
D7
A8

C C C
C

ACT4
ACT#4
ACT0
ACT#0

A
A2

B2

C2

D2

A A A
D1
A1

B1

C1

C C C
C
CG2

FAIL4
FAIL#4
ACT#8
FAIL0
FAIL#0

ACT8
A FAIL8 A
A

SAS #0 SAS #8
FAIL#8

SAS #4 SAS #12


SAS3-836EL2 S1 J0
S8
S7
S14
P1 P15
S1 J4
S7 P1 P15 S1 J8 S7
S8 S14
P1 P15
S1 J12 S7 S8
S14
P1 P15

REV1.01 SAS
#0 SAS SAS SAS
#4 #8 #12

Figure 3EL-4. Rear Connectors

Rear SAS/SATA Connectors

Rear
SAS/SATA Drive Number
Connector
SAS #0 SAS/SATA HDD #0
SAS #1 SAS/SATA HDD #1
SAS #2 SAS/SATA HDD #2
SAS #3 SAS/SATA HDD #3
SAS #4 SAS/SATA HDD #4
SAS #5 SAS/SATA HDD #5
SAS #6 SAS/SATA HDD #6
SAS #7 SAS/SATA HDD #7
SAS #8 SAS/SATA HDD #8
SAS #9 SAS/SATA HDD #9
SAS #10 SAS/SATA HDD #10
SAS #11 SAS/SATA HDD #11
SAS #12 SAS/SATA HDD #12
SAS #13 SAS/SATA HDD #13
SAS #14 SAS/SATA HDD #14
SAS #15 SAS/SATA HDD #15

C-47
SC836 Chassis Manual

Rear LED Indicators

Rear Connector Hard Drive Activity LED Failure LED


SAS #0 ACT #0 FAIL #0
SAS #1 ACT #1 FAIL #1
SAS #2 ACT #2 FAIL #2
SAS #3 ACT #3 FAIL #3
SAS #4 ACT #4 FAIL #4
SAS #5 ACT #5 FAIL #5
SAS #6 ACT #6 FAIL #6
SAS #7 ACT #7 FAIL #7
SAS #8 ACT #8 FAIL #8
SAS #9 ACT #9 FAIL #9
SAS #10 ACT #10 FAIL #10
SAS #11 ACT #11 FAIL #11
SAS #12 ACT #12 FAIL #12
SAS #13 ACT #13 FAIL #13
SAS #14 ACT #14 FAIL #14
SAS #15 ACT #15 FAIL #15

C-48
Appendix C Backplane Specifications

Dual Port and Cascading Configurations

Single and Dual Port Expanders


SAS connectors PRI-J1 to J4 and SEC-J1 to J4 are bidirectional and can be treated
as input or output.

Single Ports
BPN-SAS3-836EL1 backplanes have a single port expander that accesses all of
the drives and supports cascading.

Port A Primary Expander 1


Secondary Expander To Lower Backplane
Not Present on EL1 Models in Cascaded System

MH1 MH13 MH5 MH6 MH4

SEC-J4
S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9


+

19 EC19 EC20 EC2


+

1
J33

L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8
PRI-J4
CG2 L10 L7

SEC-J3
CG3 CG1
L5 DESIGNED IN USA

PRESS FIT
CG1
OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1

SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

SEC-J2
A P_MDIO CG3

PRI-J3
CG2 J17 CG1
MH2 C

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8
PRESS FIT
+

WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR
J22

CG3 CG1 PRI_I2C1


D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2
PRI_J2
D1

L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

SEC-J1
CG3 AF
CG1 AE

PRI-J2
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1
26
25
D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT

EC13 EC14
+

EC12
+

EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0
J21
C1

B1

A1

F3

F7

20
CG2
S_HB_LED U1
D2
C1

C2

B2
A1
A2
B1

K
D1

S_SDB PRI_J1
A C
J36 1 4 15 CG2
J35 Y2 PWR2
S_UART 1 4
E

PRI-J1
10 CG3 CG1
A
A7
D7
D8

C8

B8

A8
C7

B7

H E A
PRESS FIT

H E A
26 25 20 15 10 5 1
5
J20

11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4
D1
D2
C1
C2
B1
B2
A1
A2

11 J34
+

2 EC6 EC5
+

S_JTAG P_MDIO 2 8
55
F1

J29 9 L1
EC18

MH9 J27
MH3 MH12 1

From HBA or
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Higher Backplane
Figure 3EL-4. BPN-SAS3-836EL1 Single Port Configuration

Dual Ports
BPN-SAS3-836EL2 model backplanes have dual-port expanders that access all
of the hard drives. These dual-port expanders support cascading, failover, and
recovery.
Port B: Secondary Expander Ports Port A: Primary Expander Ports

To Lower Backplane in To Lower Backplane in


Cascaded System Cascaded System
MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A

SEC-J4
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9


+

19 EC19 EC20 EC2


+

1
J33

L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

PRI-J4
A7
A8
D7
D8
C7
C8
B7
B8

CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA
PRESS FIT

SEC-J3
CG1
OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1

SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2

L3
D1

C1
C2
B1
B2
A1
A2

PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

PRI-J3
J17 A P_MDIO CG3 CG1
CG2 C
MH2
A7
D7
D8
C7
C8
B7
B8

A8

SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8
PRESS FIT
+

WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR
J22

CG1

SEC-J2
CG3 PRI_I2C1
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2

PRI_J2
D1

L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

CG3 AF
CG1 AE

SEC-J1
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1

PRI-J2
26
25
D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT

EC13 EC14
+

EC12
+

EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0
J21
C1

B1

A1

F3

F7

20
CG2
S_HB_LED U1
D2
C1

C2

B2
A1
A2
B1

K
D1

S_SDB PRI_J1
A C
J36 1 4 15 CG2
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A
A7
D7
D8

C8

B8

A8
C7

B7

H E A

PRI-J1
PRESS FIT

H E A
26 25 20 15 10 5 1
5
J20

11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4
D1
D2
C1
C2
B1
B2
A1
A2

11 J34
+

2 EC6 EC5
+

S_JTAG P_MDIO 2 8
55
F1

J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

From HBA#2 or From HBA#1 or


Higher Backplane Higher Backplane

Figure 3EL-5. BPN-SAS3-836EL2 Dual Port Configuration

C-49
SC836 Chassis Manual

Failover
The BPN-SAS3-836EL2 model backplane has two expanders which enable effective
failover and recovery.

Single Host Bus


Adapter SAS HBA
In a single host bus configuration, the
backplane connects to one host bus
adapter. MH1

S_ICE_HDR
MH13 MH5

P_SDB
MH6

1 2 3
MH4

J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C

SEC-J4
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9

+
19 EC19 EC20 EC2

+
1
J33

PRI-J4
L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8
CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA

PRESS FIT
CG1

OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1
SEC_J2 CG3

SEC-J3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI-J3
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER

+
EC15 2 EC3 EC4 J28
+

4 EC7 EC8

PRESS FIT
+

+
WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR

J22
CG3 CG1 PRI_I2C1
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

SEC-J2

D2
C1
C2
B1
B2
A1
A2
PRI_J2

D1
L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

AF

PRI-J2
CG3 CG1 AE
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

SEC-J1
26 CG3 CG1
25

D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT
EC13 EC14
+

EC12

+
EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0

J21
C1

B1

A1

F3

F7
20
CG2
S_HB_LED U1

D2
C1

C2

B2
A1
A2
B1
K

D1
S_SDB PRI_J1
A C
J36 1 4 15 CG2

PRI-J1
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A

A7
D7
D8

C8

B8

A8
C7

B7
H E A

PRESS FIT
H E A
26 25 20 15 10 5 1
5

J20
11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4

D1
D2
C1
C2
B1
B2
A1
A2
11 J34
+

2 EC6 EC5

+
S_JTAG P_MDIO 2 8
55

F1
J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Port B Port A
Expander 2 Expander 1

Figure 3EL-6. Single HBA

Single Host Bus Adapter


Failover
If the expander or data path in Port A SAS HBA
fails, the system automatically switches
to Port B with application software or
failover support. MH1

S_ICE_HDR
MH13 MH5

P_SDB
MH6

1 2 3
MH4

J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C

SEC-J4
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9


+

19 EC19 EC20 EC2


+

1
J33

PRI-J4
L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8

CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA
PRESS FIT

CG1
OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1

SEC_J2 CG3

SEC-J3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2

L3
D1

C1
C2
B1
B2
A1
A2

PRI-J3
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2
A7
D7
D8
C7
C8
B7
B8

A8

SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8
PRESS FIT
+

WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR
J22

CG3 CG1 PRI_I2C1


D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

SEC-J2
D2
C1
C2
B1
B2
A1
A2

PRI_J2
D1

L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

AF

PRI-J2
CG3 CG1 AE
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

SEC-J1
26 CG3 CG1
25
D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT

EC13 EC14
+

EC12
+

EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0
J21
C1

B1

A1

F3

F7

20
CG2
S_HB_LED U1
D2
C1

C2

B2
A1
A2
B1

K
D1

S_SDB PRI_J1
A C
J36 1 4 15 CG2

PRI-J1
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A
A7
D7
D8

C8

B8

A8
C7

B7

H E A
PRESS FIT

H E A
26 25 20 15 10 5 1
5
J20

11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4
D1
D2
C1
C2
B1
B2
A1
A2

11 J34
+

2 EC6 EC5
+

S_JTAG P_MDIO 2 8
55
F1

J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Port B Port A
Expander 2 Expander 1

Figure 3EL-7. Single HBA Failover

C-50
Appendix C Backplane Specifications

Failover with RAID Cards and Multiple HBAs


The BPN-SAS3-836EL backplane may be configured for failover with multiple HBAs
using either RAID controllers or HBAs to acheive failover protection.
RAID Controllers: If RAID controllers are used, then the failover is accomplished
through port failover on the same RAID card.
HBAs: If multiple HBAs are used to achieve failover protection and load balancing,
Linux MPIO software must be installed and correctly configured to perform the load
balancing and failover tasks.

Dual Host Bus


SAS HBA
Adapter
In a dual host bus configuration, the
SAS HBA
backplane connects to two HBAs.
MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 1 J19 P_UART P_HB_LED

SEC-J4
EC16 4 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9

+
19 EC19 EC20 EC2
+

1
J33

PRI-J4
L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8
CG2 L10 L7
CG3 CG1
DESIGNED IN USA

SEC-J3
L5

PRESS FIT
CG1
OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1

SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI-J3
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8

PRESS FIT
+

+
WWN
EC17 1 2 20
J31

1 3

SEC-J2
P_ICE_HDR

J22
CG3 CG1 PRI_I2C1
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2
PRI_J2

D1
L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

PRI-J2
CG3 AF
CG1 AE

SEC-J1
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1
26
25

D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT
EC13 EC14
+

EC12
+

EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0

J21
C1

B1

A1

F3

F7

20
CG2
S_HB_LED U1

D2
C1

C2

B2
A1
A2
B1
K

D1
S_SDB PRI_J1
A C
J36 1 4 CG2

PRI-J1
15
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A

A7
D7
D8

C8

B8

A8
C7

B7
H E A

PRESS FIT
H E A
26 25 20 15 10 5 1
5

J20
11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4

D1
D2
C1
C2
B1
B2
A1
A2
11 J34
+

2 EC6 EC5

+
S_JTAG P_MDIO 2 8
55
F1

J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Port B Port A
Expander 2 Expander 1
Figure 3EL-8. Dual HBA
Dual Host Bus Adapter
Failover
If the expander or data path in Port SAS HBA
A fails, the system automatically
switches to Port B. This maintains
SAS HBA
a full connection to all drives.
MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED

SEC-J4
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9


+

19 EC19 EC20 EC2


+

1
J33

PRI-J4
L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8

CG2 L10 L7
CG3 CG1
DESIGNED IN USA

SEC-J3
L5
PRESS FIT

CG1
OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1

SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2

L3
D1

C1
C2
B1
B2
A1
A2

PRI-J3
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2
A7
D7
D8
C7
C8
B7
B8

A8

SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8
PRESS FIT
+

WWN
EC17 1 2 20
J31

1 3

SEC-J2
P_ICE_HDR
J22

CG3 CG1 PRI_I2C1


D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2

PRI_J2
D1

L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

PRI-J2
CG3 AF
CG1 AE

SEC-J1
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1
26
25
D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT

EC13 EC14
+

EC12
+

EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0
J21
C1

B1

A1

F3

F7

20
CG2
S_HB_LED U1
D2
C1

C2

B2
A1
A2
B1

K
D1

S_SDB PRI_J1
A C
J36 1 4 CG2

PRI-J1
15
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A
A7
D7
D8

C8

B8

A8
C7

B7

H E A
PRESS FIT

H E A
26 25 20 15 10 5 1
5
J20

11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4
D1
D2
C1
C2
B1
B2
A1
A2

11 J34
+

2 EC6 EC5
+

S_JTAG P_MDIO 2 8
55
F1

J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Port B Port A
Expander 2 Expander 1

Figure 3EL-9. Dual HBA Failover

Important: For RAID controllers, redundancy is achieved through port failover. For
multiple HBAs MPIO software is required to achieve failover protection.

C-51
SC836 Chassis Manual

SAS3 JBOD Configuration with BPN-SAS3-836EL

In a cascaded configuration, the first chassis (head node) includes a motherboard


and at least one host bus adapter (HBA). The SC836 chassis with 836EL backplane
can be configured as JBOD with a JBOD Control Board. This section describes
the supported JBOD Control Board for the BPN-SAS3-836EL series backplanes.
For more information, see the Supermicro web site at www.supermicro.com.

4 MH1 4 4 4 4 4 4
4 MH2
FAN1

JPI2C1
FAN8
JP1

FAN7
3
2
1

1 2 3 4
1 1 1 1 1 1 1 1
1 6 5
FAN2 FAN4 C160 FAN5 FAN6 13

1
FAN3

1 3 C146
2 4

4
4 +
U8

9 JP2 C

LE2
+
1 3 JP3 C10
2 4 U1 C4
5
1
1 FAN10 A
FAN9 U*
JP4

1 3
C130

J3 2 4
JP7 U5
Q3
#
U10

3 C89
+
1
20
2

R
Q18 C9
10

U9
Y1
+

K
BT1 15
1

J2
2

6
7
C

U3
10

E
LE1
U12
Q19

C93
Q13
A

A
5

U13 U14 U17 U18 U16 5 9 7 3 1


1

C144

17 16 15 19 F1 JP6 6 12 C115
+
2-3:DHCP
1-2:Static IP
JP7

U11

R138
U7 1
48 37
L7 36 A E K R Y U6
C8
Y2

J4 J5 J6 J7
12 2 2 2 2
25
13 1 1 1
24 1
MH4
Q16

JPW1
18 7 7 7 JP5 24
8 8 8 8 7 1-2:SAS3 1 JF1
14 13 J8 1 7 2-3:SAS2_847D JP5 3 20 JF1 2 MH3 NMI X PWR LED X NIC1 X OH/FF X RST ON PWR ON 12

1
2
3
Figure 3EL-10. CB3 JBOD Control Board (Sold Separately)

Power Card
Part Number Part Type Where Used
Allows the chassis to be used as
a JBOD (Just a Bunch of Disks)
CSE-PTJBOD-CB3 JBOD Control Board
system, which supports IPMI for
remote on/off control.

For more information about CB3, refer to Appendix E: CSE-PTJBOD-CB3 Control


Board.

C-52
Appendix C Backplane Specifications

Support Cables

Connecting an Internal HBA to the Backplane


The following section lists the most common cables used to connect the HBA to
the backplane.

HBA

MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9

+
19 EC19 EC20 EC2

+
1
J33

PRI-J4
L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8
CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA

PRESS FIT
CG1

OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1
SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI-J3
PRI_J3 CG2
2 4
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER

+
EC15 2 EC3 EC4 J28
+

4 EC7 EC8

PRESS FIT
+

+
WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR

J22
CG3 CG1 PRI_I2C1
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2
PRI_J2

D1
L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

PRI-J2
CG3 AF
CG1 AE
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1
26
25

D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT
EC13 EC14
+

EC12

+
EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0

J21
C1

B1

A1

F3

F7
20
CG2
S_HB_LED U1

D2
C1

C2

B2
A1
A2
B1
K

D1
S_SDB PRI_J1
A C
J36 1 4 CG2

PRI-J1
15
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A

A7
D7
D8

C8

B8

A8
C7

B7
H E A

PRESS FIT
H E A
26 25 20 15 10 5 1
5

J20
11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4

D1
D2
C1
C2
B1
B2
A1
A2
11 J34
+

2 EC6 EC5

+
S_JTAG P_MDIO 2 8
55

F1
J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Figure 3EL-11. Single Internal Host Bus Adapter

HBA
HBA

MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C

SEC-J4
D7
D8
C7
C8
B7
B8
A7
A8
+

D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2
PRESS FIT

EC1 EC10 EC9


+

19 EC19 EC20 EC2


+

1
J33

PRI-J4
L12
REV 1.01
D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8

CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA
PRESS FIT

SEC-J3
CG1
OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1

SEC_J2 CG3
A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2

L3
D1

C1
C2
B1
B2
A1
A2

PRI_J3

PRI-J3
2 4 CG2
J32

SMB 1 3
D2

C2
D1

B2

A2
C1

B1

A1

J17 A P_MDIO CG3 CG1


CG2 C
MH2
A7
D7
D8
C7
C8
B7
B8

A8

SECONDARY EXPANDER
+

EC15 2 EC3 EC4 J28


+

4 EC7 EC8
PRESS FIT
+

WWN
EC17 1 2 20
J31

1 3 P_ICE_HDR
J22

CG3 CG1 PRI_I2C1

SEC-J2
D8
C7
C8
B7

B8
A7
A8
D7

BAR CODE
MH8

WWN
MH7
PRESS FIT

D2
C1
C2
B1
B2
A1
A2

PRI_J2
D1

L6 1 C21 CG2
MH11
SEC_J1
D2

C2

B2

A2
D1

C1

B1

A1

CG2
HS1

AF

PRI-J2
CG3 CG1 AE

SEC-J1
D8
C7
C8
B7
B8
A7

A8

HS2
D7
PRESS FIT

Y CG3 CG1
26
25
D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT

EC13 EC14
+

EC12
+

EC11
D2

C2

B2

A2

R
TP75
D1

SEC_J0
J21
C1

B1

A1

F3

F7

20
CG2
S_HB_LED U1
D2
C1

C2

B2
A1
A2
B1

K
D1

S_SDB PRI_J1
A C
J36 1 4 15 CG2

PRI-J1
J35 Y2 PWR2
S_UART 1 4
E

10 CG3 CG1
A
A7
D7
D8

C8

B8

A8
C7

B7

H E A
PRESS FIT

H E A
26 25 20 15 10 5 1
5
J20

11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4
D1
D2
C1
C2
B1
B2
A1
A2

11 J34
+

2 EC6 EC5
+

S_JTAG P_MDIO 2 8
55
F1

J29 9 L1
EC18

MH9 J27
MH3 MH12 1
U48
1 9 1 4 J18
S_MDIO 1 Y1
1 2 3 P_JTAG 10

Figure 3EL-12. Dual Internal Host Bus Adapter

IMPORTANT: See page C-51 of this manual, Failover with RAID Cards and Multiple
HBAs for important information on supported configurations.

C-53
SC836 Chassis Manual

Supported Internal HBA Cables


Use the following cables to create connections between the internal HBA and
BPN-SAS3-826EL model backplane. The cables required depend upon the HBA
connector.
Cable Name: Internal iPass (Mini-SAS) to HD (Mini-SAS)
Part #: CBL-SAST-0508-01 Length: 50 cm (19 inches)
Part #: CBL-SAST-0507-01 Length: 80 cm (31 inches)

Description: This cable has an iPass (SFF-8087/Mini-SAS) connector (36-pin) at


one end and a Mini-SAS HD (SFF-8643) connector at the other end. It connects
from the SAS2 HBA to the BPN-SAS3-826EL model backplane.

Cable Name: Internal HD (Mini-SAS) to HD (Mini-SAS)

Part #: CBL-SAST-0568 Length: 35 cm (13 inches)


Part #: CBL-SAST-0593 Length: 60 cm (23 inches)

Description: This cable has a Mini-SAS HD (SFF-8643) connector at both ends. It


connects from the SAS3 HBA to the BPN-SAS2-826EL model backplane.

C-54
Appendix C Backplane Specifications

Connecting an External HBA to the Backplane


This backplane supports external host bus adapters. In this configuration, the HBA
and the backplane are in different physical chassis. This allows a JBOD (Just a
Bunch Of Disks) configuration from an existing system.

Single External Host Bus Adapter

MH1 MH13 MH5 MH6 MH4

S_ICE_HDR P_SDB 1 2 3
J37 20 L2
2 ACTLED1 1 J24 4 1 J19 P_UART P_HB_LED
EC16 A C A C

D7
D8
C7
C8
B7
B8
A7
A8
+
D21
1 4 L4 5V_LED1 12V_LED1
CG3 CG1 A
C
SEC_J3

BPN-SAS3-836EL2

PRESS FIT
EC1 EC10 EC9

+
19 EC19 EC20 EC2

+
1

J33
PRI-J4
L12
REV 1.01

D2
C1
C2
B1
B2
A1

A2
D1

A7
A8
D7
D8
C7
C8
B7
B8
CG2 L10 L7
CG3 CG1
L5 DESIGNED IN USA

PRESS FIT
CG1

OVERHEAT_FAIL2

J23
OVERHEAT_FAIL1
SEC_J2 CG3

A7
D7
D8

C8

B8

A8
C7

B7
PRESS FIT

D2
L3

D1

C1
C2
B1
B2
A1
A2
PRI_J3

PRI-J3
2 4 CG2

J32
SMB 1 3

D2

C2
D1

B2

A2
C1

B1

A1
J17 A P_MDIO CG3 CG1
CG2 C
MH2

A7
D7
D8
C7
C8
B7
B8

A8
SECONDARY EXPANDER

+
EC15 2 EC3 EC4 J28
+

4 EC7 EC8

PRESS FIT
+

+
WWN
EC17 1 2 20

J31
1 3 P_ICE_HDR

J22
CG3 CG1 PRI_I2C1

D8
C7
C8
B7

B8
A7
A8
D7
BAR CODE
MH8

WWN
MH7

PRESS FIT

D2
C1
C2
B1
B2
A1
A2
PRI_J2

D1
L6 1 C21 CG2
MH11
SEC_J1

D2

C2

B2

A2
D1

C1

B1

A1
CG2
HS1

CG3 AF
CG1 AE

PRI-J2
D8
C7
C8
B7
B8
A7

A8
HS2
D7
PRESS FIT

Y CG3 CG1
26
25

D7
D8
C7
C8
B7
B8
A7
A8
J30

F5

F9

PRESS FIT
EC13 EC14
+

EC12

+
EC11
D2

C2

B2

A2
R

TP75
D1

SEC_J0

J21
C1

B1

A1

F3

F7
20
CG2
S_HB_LED U1

D2
C1

C2

B2
A1
A2
B1
K

D1
S_SDB PRI_J1
A C
J36 1 4 15 CG2
J35 Y2 PWR2
S_UART 1 4
E

PRI-J1
10 CG3 CG1
A

A7
D7
D8

C8

B8

A8
C7

B7
H E A

PRESS FIT
H E A
26 25 20 15 10 5 1
5

J20
11
LT3
55 LT4
1 4 1
PWR1 A E K R Y AE AF PRI_J0
4 H E A U8 CG2
H E A 10
1 4 1 PWR3 1 MH10
PWR4

D1
D2
C1
C2
B1
B2
A1
A2
11 J34

+
2 EC6 EC5

+
S_JTAG P_MDIO 2 8
55

F1
J29

You might also like