1145 Series: Medium Pressure Filters
1145 Series: Medium Pressure Filters
1145 Series: Medium Pressure Filters
1145 Series
Medium Pressure Filters
NG
RI
TU
F EA
TYPICAL APPLICATIONS
Industrial Power Units
Mobile Construction Equipment
Forestry Equipment
TYPICAL APPLICATIONS
72
02 MEDIUM PRESSURE FILTERS 27/6/02 4:39 pm Page 73
SPECIFICATION
Assembly: Indicator Options:
In-line filter Indicating differential pressure:
Connections: 2.5 ± 0.2 bar
Threads G1, G11/4, G11/2 (ISO 228/1) or 11/2” SAE 3000 flange - electronic indicator FPC.F (10 to 36 VDC)
- electrical indicator FPC.T (max 250 VAC)
Operating Pressure:
- visual indicator FPC.V
Max 40 bar, filter housing pressure pulse fatigue tested:
106 pulses 0-40 bar Indicator Housing:
Material brass (code M)
Seal Material:
Nitrile (ordering code B) or Fluoroelastomer eg. Viton (ordering code V) Filter Housing:
Head material cast iron (GSI).
Operating Temperature Range:
Bowl material steel.
-20° to +100°C
Filter Element; and Collapse Ratings:
Degree of Filtration:
7000 Series (Q0XX)
Determined by multipass test according to ISO 16889
Microglass III media, end cap material reinforced composite (code
Filtration Media: K) and metal inner core. Collapse rating 20 bar (ISO 2941).
Microglass III supported with epoxy coated metal wire mesh or 7000 Eco (QEXX)
Ecoglass III supported with plastic net (no metallic parts) (see Table 2) Ecoglass III media, end cap material reinforced composite (code
Flow Fatigue Characteristics: K), no metallic parts. Filter element can only be used together with
Filter media is supported so that the optimal fatigue life is achieved re-usable FEA Eco-adaptor. Collapse rating 10 bar (ISO 2941).
Bypass Valve: Note: Ecoglass III contributes to ISO14001 quality.
Opening pressure 3.5 bar
PLUG M12x1.5
TYPE A B C D
1145 116 (4.57) 237 (9.33) 192 (7.56) G1, G11/4
1146 208 (8.20) 330 (13.00) 285 (11.22) G11/2
1147 329 (13.00) 450 (17.72) 405 (15.94) SAE 1 /2” 3000 psi
1
D D
1148 428 (16.85) 550 (21.65) 505 (19.90)
69.8
4 pcs M12 depth
(2.75)
18 only model SAE
38
(1.50)
35.7
(1.40) A
M10 DEPTH 12
mm
(inches)
70 132
(2.75) (5.20)
50 MIN
(2.00)
58
(2.28)
73
02 MEDIUM PRESSURE FILTERS 27/6/02 4:39 pm Page 74
INDICATOR DETAILS
Visual Differential Pressure Indicator Electrical & Electronic Differential Pressure Indicator
CODE FPC.V CODE FPC.T & FPC.F
29
(1.14)
mm 70
(2.75)
(inches)
Visual Indicator
V25 N/A N/A FPC.V25.BM
(2.5 bar)
FPC.F 3 +V FPC.F 3 +V
NPN +10...36 VDC PNP +10...36 VDC
1 Load 1 Load
Electronic Indicator Normally
open
Normally
open
F25 +10 to 36 VDC (N.O.) (N.O.) FPC.F25.BM
(2.5 bar) 2 Load 2 Load
4 0V 4 0V
max 300 mA -10...36 VDC max 300 mA -10...36 VDC
P1-P2
No
Connect
Electrical Indicator Max 250 VAC
T25 (2.5 bar) FPC.T25.VM
Normally Closed (N.C.)
Pin 2 3 1
74
02 MEDIUM PRESSURE FILTERS 27/6/02 4:39 pm Page 75
∆p (psid)
14.5
∆p (bar)
GT16
0.8 11.6
GT20
0.6 8.7
0.4 5.8
GT24
0.2 ST24 2.9
0 0
0 25 50 75 100 125 150 175 200 225 250
Flow (l/min)
1145 Series with Microglass III 1146 Series with Microglass III
Flow (US GPM) Flow (US GPM)
∆p (psid)
∆p (bar)
∆p (bar)
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
Flow (l/min) Flow (l/min)
1147 Series with Microglass III 1148 Series with Microglass III
Flow (US GPM) Flow (US GPM)
Q010
∆p (psid)
Q005
∆p (bar)
∆p (bar)
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
Flow (l/min) Flow (l/min)
Note: These graphs relate to the 7000 Series elements which are used in all 1145 Series filters.
75
02 MEDIUM PRESSURE FILTERS 27/6/02 4:39 pm Page 76
1145 Series with Ecoglass III 1146 Series with Ecoglass III
Flow (US GPM) Flow (US GPM)
∆p (psid)
∆p (psid)
∆p (bar)
∆p (bar)
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
Flow (l/min) Flow (l/min)
1147 Series with Ecoglass III 1148 Series with Ecoglass III
Flow (US GPM) Flow (US GPM)
∆p (psid)
∆p (psid)
QE05 QE05
∆p (bar)
∆p (bar)
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
Flow (l/min) Flow (l/min)
Note: These graphs relate to the 7000 Series elements which are used in all 1145 Series filters.
76
02 MEDIUM PRESSURE FILTERS 27/6/02 4:39 pm Page 77
ECO Range
Part Number Flow (l/min) Media Rating Ports Replacement Elements
FF1145.QE20.BS35.GT16 100 QE20 G1 FC7005.QE20.BK
FF1145.QE10.BS35.GT16 80 QE10 G1 FC7005.QE10.BK
FF1145.QE05.BS35.GT16 60 QE05 G1 FC7005.QE05.BK
FF1145.QE02.BS35.GT16 50 QE02 G1 FC7005.QE02.BK
FF1146.QE20.BS35.GT16 150 QE20 G1 FC7006.QE20.BK
FF1146.QE20.BS35.GT20 170 QE20 G11/4 FC7006.QE20.BK
FF1146.QE10.BS35.GT16 100 QE10 G1 FC7006.QE10.BK
FF1146.QE10.BS35.GT20 120 QE10 G11/4 FC7006.QE10.BK
FF1146.QE05.BS35.GT16 80 QE05 G1 FC7006.QE05.BK
FF1146.QE05.BS35.GT24 100 QE05 G11/2 FC7006.QE05.BK
FF1146.QE02.BS35.GT16 60 QE02 G1 FC7006.QE02.BK
FF1147.QE10.BS35.GT24 170 QE10 G11/2 FC7007.QE10.BK
FF1147.QE05.BS35.GT24 130 QE05 G1 /2
1
FC7007.QE05.BK
FF1147.QE02.BS35.GT24 110 QE02 G11/2 FC7007.QE02.BK
Note: Filter assemblies ordered from the Part Number Matrix on the next page are on extended
lead times. Where possible, please make your selection from the tables above.
77
02 MEDIUM PRESSURE FILTERS 27/6/02 4:39 pm Page 78
Table 7 Table 8
p Indicator: FPC M
Table 3
Seal Kit: FD 1145-
Table 1B Table 3
Eco-adaptor: FEA
G1 Thread GT16 Non-return valve T Visual Indicator 2.5 bar V25 V25 Nitrile B
G 11/4 Thread GT20 Electronic Indicator 2.5 bar, (+10 to 36VDC) F25 F25 Nitrile B
G11/2 Thread GT24 Electrical Indicator 2.5 bar, (max 250VAC) T25 T25 Fluoroelastomer V
78