Professional Documents
Culture Documents
Attachment To Test Report Iec 62471 European Group Differences and National Differences
Attachment To Test Report Iec 62471 European Group Differences and National Differences
50B
IEC62471A - ATTACHMENT
Clause Requirement + Test Result - Remark Verdict
EN 62471
Clause Requirement + Test Result – Remark Verdict
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
Test condition: GLS Non GLS Worst Case
Lamp classification group: exempt risk 1 risk 2 risk 3
Emission Measurement For BN108C LED28 CW L1200, α= 100 mrad
Action
Risk Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light,
B(λ) EB W•m-2 0,01* -- 1,0 400
small source
Retinal
R(λ) LR W•m-2•sr-1 28000/α 429,32 28000/α 71000/α
thermal
545000
Retinal --
0,0017≤ α ≤ 0,011
thermal, -2 -1
R(λ) LIR W•m •sr
weak visual
6000/α
stimulus** --
0,011≤ α ≤ 0,1
IR radiation,
EIR W•m-2 100 0,05 570 3200
eye
* Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian.
** Involves evaluation of non-GLS source
NOTE The action functions: see Table 4.1 and Table 4.2
The applicable aperture diameters: see 4.2.1
The limitations for the angular subtenses: see 4.2.2
The related measurement condition 5.2.3 and the range of acceptance angles: see Table 5.5.
Page 3 of 3 Report No.: 3150235.50B
EN 62471
Clause Requirement + Test Result – Remark Verdict
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
Test condition: GLS Non GLS Worst Case
Lamp classification group: exempt risk 1 risk 2 risk 3
Emission Measurement For BN108C LED36 CW L1200 MB, α= 100 mrad
Action
Risk Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light,
B(λ) EB W•m-2 0,01* -- 1,0 400
small source
Retinal
R(λ) LR W•m-2•sr-1 28000/α 511,68 28000/α 71000/α
thermal
545000
Retinal --
0,0017≤ α ≤ 0,011
thermal, -2 -1
R(λ) LIR W•m •sr
weak visual
6000/α
stimulus** --
0,011≤ α ≤ 0,1
IR radiation,
EIR W•m-2 100 0,04 570 3200
eye
* Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian.
** Involves evaluation of non-GLS source
NOTE The action functions: see Table 4.1 and Table 4.2
The applicable aperture diameters: see 4.2.1
The limitations for the angular subtenses: see 4.2.2
The related measurement condition 5.2.3 and the range of acceptance angles: see Table 5.5.