Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Catalog MSG14-2550/US Servovalves

Technical Information Series PH76

General Description
Series PH76 servovalves are high performance, two
stage valves, with a range of rated flows from
3.8 to 57 LPM (1 to 15 GPM). The pilot stage is a
symmetrical double-nozzle and flapper, driven by a
double air gap, dry torque motor. A low current signal
to the torque motor pilot stage results in a proportional
flow from the output stage. The output stage is a 4-way,
sliding spool which provides a mechanical feedback
using an exclusive “no ball glitch” design.

C Features
• Built to survive tank port pressure spikes

• No ball glitch

• Tool steel spool and body

• Optional 5th port for external pilot

• ISO 10372 standard 22.23 mm (0.875 in) port circle

Specifications
Flow Rating ±10% 3.8, 9.5, 19, 28, 38, 57 LPM Threshold ≤ 0.5%
@ 70 Bar (1000 PSID) (1, 2.5, 5, 7.5, 10, 15 GPM)
Null Shift
Supply Pressure 10 – 210 Bar with temperature ≤ 2% per 55°C (100°F)
(145 – 3000 PSI) with pressure ≤ 2% per 70 Bar (1000 PSI)
Tank Port Pressure 210 Bar (3000 PSI) Max. Pressure Gain 30% minimum, 70% max.
< 10 Bar (145 PSI) for % change in pressure per
best performance 1% change in input
command
Null Leakage Flow 0.2 – 0.8 LPM
per 70 Bar (1000 PSID) (0.05 – 0.20 GPM) Step Response 10 – 90%, < 6 ms
Pilot Flow 0.8 – 1.2 LPM Fluid Mineral Oil, 60 – 225 SSU
@ 210 Bar (3000 PSID) (0.21 – 0.33 GPM) 1000 SSU maximum
Input Command ±50 mA std. Operating Temperature -1°C to +82°C
(+30°F to +180°F)
Frequency Response > 90 Hz
@ 90° phase shift (See Performance Curves) Protection Class NEMA 4, IP65
Non-Linearity ≤ 10% Fluid Cleanliness ISO 4406 15/12 or better

WARNING: This product can expose you to chemicals including Lead, Nickel (Metallic), or 1,3-Butadiene which are known to the State of California to
cause cancer, and Lead or 1,3-Butadiene which is known to the State of California to cause birth defects and other reproductive harm. For more information
go to www.P65Warnings.ca.gov.
C01_Cat2550.indd, ddp, 04/19

C12 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog MSG14-2550/US Servovalves
Ordering Information Series PH76

PH76 A
Series Pilot Material Coils Wiring Seal Operating Flows Special
Source Options Pressure Options Factory Code for Special Options

Code Description Code Description


C External (5th port) Omit Standard
A Internal D (Specify)
Consult factory for price,
For internal pilot the 5th

C
delivery, and availability
port is blocked internally.
of special options.

Code Description
Code Description
A Steel (standard)
1 3.8 LPM (1.0 GPM)
2.5 9.5 LPM (2.5 GPM)
5 19.0 LPM (5.0 GPM)
Code Description Parallel Series 7.5 28.0 LPM (7.5 GPM)
D 200 ohm (Std.) 50 mA 25 mA 10 38.0 LPM (10.0 GPM)
F 80 ohm 40 mA 20 mA 15 57.0 LPM (15.0 GPM)
G 22 ohm 200 mA 100 mA
K 40 ohm 150 mA 75 mA
M 475 ohm 40 mA 20 mA Code Description
T 1000 ohm 8 mA 4 mA A 210 Bar (3000 PSI)
Z Special (Specify) B 450 Bar (5000 PSI)

Code Connector over Flow P to C2 with: Code Description


B Port C2 (+) signal to A, C V Fluorocarbon (std.)
Weight: 1 kg (2.2 lb)
A Port C1 (+) signal to A, C N Nitrile
P Port P (+) signal to A, C * Consult factory for delivery.
T Port T (+) signal to A, C

Cable with mating connector: EHC154S


Mating connector: MS3106E-14S-2S
Bolt kit: Included with valve. BK07 (4) 5/16-18x1"
Flushing valve: 1200127 (same for 4 or 5 port PH76 valve)
Subplate, 5 ports: 1402303 (4) #12 SAE side ports, (1) #4 SAE side port
Subplate, 4 ports: 810090-3 (4) #12 SAE side ports
Null adjust tool: 6522A13 Flushing valve is rated for 3000 psi operation.
Driver cards: 23-7030, BD90*, BD101*
When used in conjunction with Series BD90 and BD101 servo amplifiers or
a motion controller, Series BD valves will provide
accurate control of rotary and linear actuators.
* For output currents >15 mA

C01_Cat2550.indd, ddp, 04/19

C13 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog MSG14-2550/US Servovalves
Technical Information Series PH76

Performance Curves Frequency Response


Servovalve flow is proportional to the square root of the pressure The frequency response curves for the PH76 servovalves show
drop through the valve. The nominal flow rating for the servo- no significant change for signal amplitudes between ±10% and
valves is based upon a 70 Bar (1000 PSI) pressure drop. ±40%. Frequency response is unaffected by changes in supply
pressures above 70 Bar (1000 PSI).

Flow vs. Pressure Drop


at 100% command

Amplitude ratio (dB)


GPM LPM Flow Path: P C1 C2 R ± 40% Command
+5
32 120 15 0
21 80 10 No
7.5 load -5

C
11 40 5 flow -10
curves
7 28 at
Flow (Q)

5 20 2.5 rated
flow
3 12

Phase lag (degrees)


2 8 -135 1000 PSI
1
-90
1 4
0.5 2 -45
3000 PSI
0
0.2 0.8
Bar 21 35 70 140 210 1 10 50 100
PSI 300 500 1000 2000 3000 Frequency (Hz)
Pressure Drop

Installation Wiring Options


The PH76 servovalve has two coils. One is wired across pins A to B, the other across pins C to D. When con-
necting the valve to a drive amplifier, the user's external wiring may put the coils either in parallel or in series as
needed. In either case, a positive voltage to pin A connects valve flow from ports P to C2 and ports C1 to R.

A B C D A B C D

Parallel Series

+ +
- -

Polarity shown (+A, -B, +C, -D) connects flow from P to C2 port.

C01_Cat2550.indd, ddp, 04/19

C14 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Catalog MSG14-2550/US Servovalves
Dimensions Series PH76
Inch equivalents for millimeter dimensions are shown in (**)
55.1
(2.17)

50.8
(2.00)

Connector shown over C2 port. See ordering


information for other connector locations.
C
The connector location is factory set and is
not field changeable.
59.2
(2.33)

D A

C B

66.0
(2.60)

8.4
(0.33)

7.4
18.0 62.7 (0.29) 72.4
(0.71) (2.47) (2.85)

Mounting Surface Dimensions


Metric Dimensions (millimeters) ± 0.1 mm 0 x
Axis P C1 R C2 G X F1 F2 F3 F4
0
∅ 8.2 ∅ 8.2 ∅ 8.2 ∅ 8.2 ∅ 3.5 ∅5 M8 M8 M8 M8
max. max. max. max. max. F1 F2
y
X 22.2 11.1 22.2 33.3 12.3 49.5 0 44.4 44.4 0 P
G
Y 21.4 32.5 43.6 32.5 19.8 39 0 0 65 65
82
(3.23)
U.S. Dimensions (inches) ± .004 in C1 C2

Axis P C1 R C2 G X F1 F2 F3 F4
R X
∅ 0.32 ∅ 0.32 ∅ 0.32 ∅ 0.32 ∅ 0.14 ∅ 0.2 5/16 - 18
max. max. max. max. max.
F4 F3
X 0.875 0.437 0.875 1.311 0.484 1.531 0 1.750 1.750 0.000
65
Y 0.846 1.280 1.717 1.280 0.780 1.950 0 0 2.562 2.562
(2.56)

Minimum depth of G is 2 mm (0.08 in)


Recommended full thread depth for bolt holes 22 mm (0.87 in)
Surface roughness: Ra < 0.8 µm (0.031 in) as specified in ISO 468 and 1302
Surface flatness: 0.025 mm (0.001 in) as specified in ISO 1101

C01_Cat2550.indd, ddp, 04/19

C15 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA

You might also like