Getriebebau NORD GmbH & Co.

KG
Getriebebau-Nord-Straße 1 • 22941 Bargteheide, Germany • www.nord.com

CABLE PLUG (F) M12-08 L= xxM


Cable IG-IGx1P

Scope of supply
1x M12 plug (M), 8-poles, straight,
1x Cable with 8 single wires, shielded, twisted pair

Part number Cable length


1955 1580 2 m
1955 1581 5 m
1955 1582 10 m
1955 1583 15 m
Incremental encoder cable for NORD option:
“IGx1P” / “IGx1P8” with 8-poles M12 plug

It only is allowed for qualified electricians to install and commission the module. An electrician is a person
who, because of their technical training and experience, has sufficient knowledge relating to
• switching on, switching off, isolating, earthing and marking power circuits and devices,
• proper maintenance and use of protective devices in accordance with defined safety standards.

DANGER! Danger of electric shock


The frequency inverter continues to carry hazardous voltages for up to 5 minutes after it was switched off.
• Work must not be carried out unless the device has been disconnected from the voltage and at least 5 minutes
have elapsed since the mains was switched off!

Field of use
Incremental encoder cable connects the electronic device with the NORD motor via “IGx1P” or
“IGx1P8” motor option. The “IGx1P” / “IGx1P8” option is equipped with 8-poles standard plug.

Technical Information / Datasheet Kabel IG-IGx1P (OE-IG-A8F


gerade)
Specification of connection cable -- 1.0 3519 en
Specification of connection cable – Kabel IG-IGx1P (OE-IG-A8F gerade)

Female

Inverter connection Encoder connection

Information Fixed laying system for the cable


This cable is only useable for stationary (not moved) installation. All values for the fixed laying system are noted
on this data sheet. Other laying systems are not allowed with this cable type.

Technical Data

M12 plug Specification Cable Specification

Contact quantity 8-poles AWM Style 20233


Coding A – coded Jacket material PUR
Contact type Female (F) Jacket color Grey
Screw M12x1 Nut Outside diameter 7.2 mm (+/- 0.28)
Construction type Straight Bending radius 10x cable diameter
Protection (screwed) NEMA 1,3,4,6P IP68 Wire cross section 4x 2x 0.25 mm²
Breakaway torque 0,6 Nm Wire isolation PVC
Pollution degree 3 General information
Operating voltage max. 60 V DC
Cable Specification Operating current max. 2 A
Braid shield coverage 26 AWG, braided shield Operating temperature -10 … + 80°C
Material Tinned copper Flammability test FT1

PIN assignment:

PIN Female (F)


Function Cable color Open wires Schematic diagram
electronic

GND 0V White Wire end sleeve 1

+Ub Brown Wire end sleeve 2

Spur „A“ Green Wire end sleeve 3

Spur „A \“ Yellow Wire end sleeve 4

Spur „B“ Grey Wire end sleeve 5

Spur „B \“ Pink Wire end sleeve 6

Spur „0“ Blue Wire end sleeve 7

Spur „0 \“ Red Wire end sleeve 8