JOSAN
JOSAN
JOSAN
A1 - PERSPECTIVE
SITE DEVELOPMENT PLAN
LOCATION MAP
TABLE OF CONTENTS
A2 - FLOOR PLAN
ROOF PLAN
ELEVATIONS
OFFICE OF THE BUILDING OFFICIALS
SECTIONS
DIPOLOG CITY
DISTRICT/CITY/MUNICIPALITY
A3 - REFLECTED CEILING PLAN
CEILING DETAILS LAND USE & ZONING
SECTION
E1 - LIGHTING LAYOUT
POWER LAYOUT
ELETRICAL DETAILS AND SPECIFICATIONS
perspective APPROVED BY
STRUCTURAL
DATE
APPROVED BY DATE
TECHNICAL DESCRIPTION
LINE BEARING DISTANCE (M)
SANITARY
LOT 1523-D-1-A
1-2 S63°37'E 10.259
2-3 S24°24'W 17.398
3-4 N65°57'W 12.440
4-1 N31°24'E 17.962
APPROVED BY DATE
2
ELECTRICAL
APPROVED BY DATE
MECHANICAL
APPROVED BY DATE
GEODITIC ENGINEER
APPROVED BY DATE
FIRE PROTECTION
5 LOCATION MAP
5 SITE DEVELOPMENT PLAN A1 NTS
A1 NTS
3
SEAL CIVIL ENGINEER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
PAULO O. SANCHEZ COMMERCIAL BUILDING
CHECKED BY:
A3
A3
A3
A3
A3
A3
6
7
8
8
591 5670 5800 5490 364 591 5672 5800 5486 364
W2 W2 W2
SERVICE/LAUNDRY SERVICE/LAUNDRY SERVICE/LAUNDRY
1600
1600
AREA TOILET & AREA TOILET & AREA TOILET &
D4
BATH
D4
BATH
D4
BATH 5 5
W1 D2 D2 D2
A3 A3
2 2
PROVIDE FLASHING
4900
D3 D3 D3
3 3
LIVING AREA LIVING AREA LIVING AREA A3 A3
BEDROOM 1 BEDROOM 1 BEDROOM 1
1 1
W1 D1 W1 W1 D1 W1 W1 D1 W1
2575 3100 2700 3100 2700 3149 PROPERTY BOUNDARY PROPERTY BOUNDARY
A A' B C D D' 1 2
FASCIA BOARD
1600 3175 1600 3175 1600 3235
DECORATIVE CONCRETE
EL.+5100 TOP OF ROOF
1118
CONCRETE CANOPY
DESIGNED AS SHOWN
EL.+3900 TOP OF ROOF BEAM (PAINT FIN.)
W1 D1 W1 W1 D1 W1 W1 W1 BRICK FIN.
2400
EL.+0300 1ST-FFL
300
EL.+0000 NGL
D' D C B A' A 2 1
D2 W1 D2 W1 D2 W1 W2 D3
EL.+0300 1ST-FFL
300
EL.+0000 NGL
SEAL CIVIL ENGINEER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
PRC.NO.: 0119608
PAULO O. SANCHEZ
Date Issue: 11/18/2023 LOCATION:
COMMERCIAL BUILDING
SANDRA F. RICHARDSON FLOOR PLAN; ROOF PLAN; ELEVATIONS
CHECKED BY:
DATE:
A3
A3
A3
6
8
591 5670 5800 5490 364
LIGHTING FIXTURES
1600
5
A3
2
3 DETAILS
350
350
A3
1 SECTION
PERSPECTIVE
FASCIA BOARD
CONCRETE CANOPY
DESIGNED AS SHOWN
EL.+3900 TOP OF ROOF BEAM (PAINT FIN.)
WALL TILES
3100
BRICK FIN.
2400
EL.+0300 1ST-FFL
SERVICE /LAUNDRY SERVICE /LAUNDRY SERVICE /LAUNDRY
BEDROOM 1 LIVING AREA BEDROOM 1 LIVING AREA BEDROOM 1 LIVING AREA AREA T & B AREA T & B AREA T & B
300
EL.+0000 NGL
A A' B C D D' 1 2 2 1 1 2
EL.+0300 1ST-FFL
SERVICE
/LAUNDRY
KITCHEN/DINING KITCHEN/DINING KITCHEN/DINING KITCHEN/DINING KITCHEN/DINING AREA
BEDROOM 2 BEDROOM 2 BEDROOM 2 LIVING AREA T & B LIVING AREA BEDROOM 1 BEDROOM 2
AREA AREA AREA AREA AREA
300
EL.+0000 NGL
SEAL CIVIL ENGINEER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
PRC.NO.: 0119608
PAULO O. SANCHEZ
Date Issue: 11/18/2023 LOCATION:
COMMERCIAL BUILDING
SANDRA F. RICHARDSON
REFLECTED CEILING PLAN; DOORS AND
CHECKED BY:
DATE:
400
1200
2100
2100
2100
2100
1700
900
FFL FFL
QTY : 3 SETS QTY : 3 SETS QTY : 6 SETS QTY : 3 SETS QTY : 9 SETS QTY : 3 SETS
HANDLING : 3 LEFT HANDLING : 3 RIGHT HANDLING : 3 LEFT, 3 RIGHT HANDLING : 3 LEFT DIMENSION : 1200X1200 MM DIMENSION : 400X400 MM
D1 PANEL DOOR (MAIN DOOR) D2 PANEL DOOR (EXIT DOOR) D3 PANEL DOOR (INTERIOR DOOR) D4 PVC BATHROOM DOOR W1 SLIDING GLASS WINDOW W2 AWNING GLASS WINDOW
2320 1200
450
700
700
GRANITE COUNTER
750
750
850
850
SEAL CIVIL ENGINEER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
PRC.NO.: 0119608
PAULO O. SANCHEZ
Date Issue: 11/18/2023 LOCATION:
COMMERCIAL BUILDING
SANDRA F. RICHARDSON
KITCHEN DETAILS; DOORS AND WINDOWS
CHECKED BY:
DATE:
A3
A3
A3
A3
A3
A3
6
7
8
8
591 5670 5800 5490 364 591 5672 5800 5486 364
3165 2000 2700 2000 2700 1734 2775 2900 2900 2900 2900 2600
1600
1600
ELEV: +0.150 ELEV: +0.250 ELEV: +0.150 ELEV: +0.250 ELEV: +0.150 ELEV: +0.250 5 5
A3 A3
2 2
F1C1 F2C1 F2C1 F1C1
4900
ELEV: +0.300 ELEV: +0.300 ELEV: +0.300
3 3
A3 A3
ELEV: +0.300 ELEV: +0.300 ELEV: +0.300
1 1
ELEV: +0.150
RIB-TYPE ROOFING
350
300X300mm COLUMNS
200
RC BEAM
2 STRUCTURAL PERSPECTIVE
S1 scale 1:100
SAG ROD CONNECTION DETAILS 4 RAFTER TRUSS DETAILS
S1 scale 1:25
SEAL CIVIL ENGINEER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
PRC.NO.: 0119608
PAULO O. SANCHEZ
Date Issue: 11/18/2023 LOCATION:
COMMERCIAL BUILDING
SANDRA F. RICHARDSON FOUNDATION PLAN; ROOF FRAMING PLAN
CHECKED BY:
DATE:
A3
A3
6-12mmØ RSB
A3
6
8
WITH 10mmØ STIRRUPS
5@50, 5@75, 5@100, REST@150mm
720
591 5670 5800 5490 364
FFL
1600
5
A3
VARIABLE
2 RB-1 RB-1 RB-1
100mm THK. GRAVEL FILL
300
4900
3100
200
ffl
NGL
800
1 BEAM PLAN
S2 scale 1:100
200
F1C1 F2C1
1000
200X200mm COLUMN WITH 200X200mm COLUMN WITH
4-12mmØ WITH 10mmØ STIRRUPS 4-12mmØ WITH 10mmØ STIRRUPS
5@50, 5@75, 5@100, REST@150mm 5@50, 5@75, 5@100, REST@150mm
RB-1
1000
2-12mmØ 2-12mmØ
STIRRUPS SPACED
5@50; 5@75. 5@100,
300
300
REST@150mm
150 150
@SUPPORT @MIDSPAN
RB1
FOOTING DETAILS
No. OF DSB No. OF DSB
DESCRIPTION DEPTH (D) LENGTH (L) WIDTH (W) THICKNESS (T) SIZE OF DSB
ALONG LENGTH ALONG WIDTH
6pcs (184mm 6pcs (184mm
F1 1.00 M 1.00 M 1.00 M 0.20 M 12mm Ø
SPACING) SPACING)
COLUMN DETAILS
SIZE AND NUMBER OF DSBTO BE
DESCRIPTION LENGTH WIDTH CLEAR COV. LATERAL TIES SIZE AND SPACING
USED
1 REINFORCEMENT PERSPECTIVE
S2 NDTS
SEAL CIVIL ENGINEER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
PRC.NO.: 0119608
PAULO O. SANCHEZ
Date Issue: 11/18/2023 LOCATION:
COMMERCIAL BUILDING
SANDRA F. RICHARDSON STRUCTURAL REINFORCEMENT DETAILS
CHECKED BY:
DATE:
591 5670 5800 5490 364 591 5672 5800 5486 364
3165 2000 2700 2000 2700 1734 3165 2000 2700 2000 2700 1734
CO
F WC F WC F WC wc wc wc
1600
1600
2" pvc soil pipe fd fd fd fd
F F F co
LAV LAV LAV TO LOCAL DRAINAGE
1.2" PPR PIPE lav lav lav
2 2
KS KS KS
ks ks
ks
4900
4900
2575 3100 2700 3100 2700 3149 PROPERTY BOUNDARY PROPERTY BOUNDARY
septic
tank
FD SHOWER/FLOOR DRAIN
VS VENT STACK
SS SOIL STACK
VAC VENT ACROSS CEILING
VP VENT PIPE
PVC POLYVINYL CHLORIDE
WP WET PIPE
SP SOIL PIPE
VTR VENT THRU ROOF
ST SEPTIC TANK
AC AIR CHAMBER
WASTE, SEWER & VENT SYSTEM
DRAINAGE LINE
DS DOWNSPOUT
SEAL MASTER PLUMBER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
DATE:
VTR
wc
f lav ks
VTR
wc
f fd
co
wc
f lav
fd
ks
wc
500
SEE SEPTIC TANK DETAILS
fd
f
200 100 200
12mmØ BAR HANDLE
co
wc
F lav
100
fd
ks
wc
50 50 50 50
fd CONCRETE SERVICE
F
ENTRANCE COVER DETAILS
co
3200
co
fd 100 1150 100 825 100 825 100
2 PLUMBING ISOMETRIC
P2 scale 1:100 500 500 500
1300
500
500
500
service service service
entrance entrance entrance
GATE VALVE
STRAINER 1"
c.o. c.o. c.o. outlet
WATER METER
CHECK VALVE 1"
BALL VALVE 1"
12mmØ DEF. BARS
SPACED@0.15m 0.C.B.W
plan
12mmØ DEF. BARS
SPACED@0.15m 0.C.B.W service service service
entrance c.o. entrance c.o. entrance c.o.
4"Ø PVC INLET PIPES S-1000
DISTRIBUTION
300
inlet 0.30M air space
outlet
1500
4"X8"X15" CHB
10mmØ DEF. BARS
SPACED @0.60m O.C.
digestive chamber leaching leaching
10mmØ DEF. BARS
SPACED @0.40m O.C. chamber chamber
200
400 400 400 400
100mm THK. GRAVE BASE
SEAL MASTER PLUMBER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
DATE:
A3
A3
A3
A3
A3
A3
6
7
8
8
591 5670 5800 5490 364 591 5672 5800 5486 364
S1 S1
1600
1600
5 5
CKT1 CKT1 CKT1 A3 CKT2 CKT2 CKT2 A3
2 2
CKT3 CKT3 CKT3
S2 S2 S2
S1 S1 S1
4 4
A3 A3
4900
4900
3 3
S1 S1 S1 A3 A3
CKT4 CKT4 CKT4
S3 S3 S3
S2 S2 S2
1 1
2575 3100 2700 3100 2700 3149 PROPERTY BOUNDARY PROPERTY BOUNDARY
SPECIAL
30A 30A LIGHTING WIRE HOMERUN 7. ALL WIRING DEVICES ARE APPOREVED TYPES.
OUTLET 3 4 SPECIAL 8.
ALL MATERIALS WERE NEW AND APPROVED TYPE FOR THE LOCATION AND PURPOSE. All materials to be supplied shall be new and of high quality suitable for the location and purpose. Materials shall be standard products of
OUTLET
SWITCH WIRE HOMERUN 10. COVER ALL JUCNTION BOXES (NO EXPOSED WIRE) reputable manufacturers.
11.
MOUNTING HEIGHTS OF WIRING DEVICES ARE AS FOLLOWS: C. TECHNICAL SPECIFICATION:
CIRCUIT HOMERUN
A. CONVENIENCE OUTLETS 300mm AFFL
SPARE B. TELEPHONE 300mm AFFL
C. LIGHT SWITCHES 1400mm AFFL 1. Power service: 115/230 volts, single phase, 3 wires solid neutral 60 hertz.
1-8.0mm2 TW COPPER WIRE D. PANELBOARDS 1400mm AFFL
2 MAIN FEEDER DIAGRAM E. DATA OUTLETS 300mm AFFL
E1 nts
12. 2. Wiring methods: all power and control wiring shall be in rigid mild steel conductor.
ALL ELECTRICAL WORKS HEREIN WRE AXECUTED BY EXPERIENCE MEN UNDER THE DIRECT
SUPPERVISION OF A FULL-TIME LICENSED ELECTRICAL ENGINEER. WORK SHALL BE NEATLY PLACED.
SECURELY FASTENED AND PROPERLY FINISHED.
3. Grounding: Panel boards, raceways, gutters, metallic conduits and other non-current carrying metal parts of equipment, heaters,
1 TYP. SINGLE LINE DIAGRAM ABBREVIATION: motors frames, shall be provided with effective: grounding connection to a grounded cold center pipe.
E1 nts ACCU AIR CONDITIONING CONDENSING UNIT
4. Main as branch feeders: Conductors and complete conduit systems shall be provide as shown in drawing and no change, in sizes
AT AMPERE TRIP
shall be made without approval by the architect or his authorized representative.
AF AMPERE FRAME
5. Panel Board: Furnish and installs the electrical panel board as shown in plan. Disconnect switches and magnetic starters shall be
SCHEDULE OF LOADS BCW
CB
BARE COPPERWIRE WIRE
CIRCUIT BREAKER provided by motor equipment supplier.
CKT No. DESCRIPTION QTY VOLTS WATTS AMP. FUSE SIZE OF WIRE CONDUITS DF DEMAND FACTOR
EF EXHAUST FAN 6. Receptacles, switches, outlet:
PER UNIT FCU FAN COIL UNIT
HZ HERTZ
C1 LIGHTING OUTLET 10 230 1000 4.35 15A 2-2.00mm² THW 15mm DIA. I = [ It + (Ih x 0.25)] DEMAND FACTOR IMC INTERMEDIATE METAL CONDUIT
KAIC KILOAMPERE INTERRUPTING CAPACITY a. Provide as indicated in drawings, the switches and receptacles with proper cover plates. Switches shall be of the quiet-matic
C2 CONVENIENCE OUTLET 6 230 1200 5.22 15A 2-2.00mm² THW 15mm DIA.
I = [50.44+ 1.7045] 80% LO LIGHTING OUTLET type, “NATIONAL”or approve equal.
C3 SPECIAL OUTLET 1 230 2500 10.87 30A 2-3.50mm² THW 15mm DIA. MCCB MOLDED CASE CIRCUIT BREAKER
C4 SPECIAL OUTLET 1 230 2500 10.87 30A 2-3.50mm² THW 15mm DIA. I = 32.6736 AMP. MM MILLIMETER
b. Receptacles shall be duplex with proper cover plates, rated 10 amp. Min.250 V. A.C., “Eagles”or approved equal.
NEMA NATIONAL ELECTRICAL MANUFACTURERS
SPARE PVC POLYVINYL CHLORIDE CONDUIT
USE: 2-16.0mm² CU. WIRE W/ 25.0mmø RSC PIPE c. Lighting outlet at ceiling shall be provided 4” octagonal box ga. 18 min. connections from fixtures to boxes be made by
31.31 SQMM SQUARE MILLIMETER
WP
IØ
WATER PROOF
SINGLE PHASE (2-POLE)
using TW wire CHB in flexible conduit.
Ø CONDUIT DIAMETER 7. Lighting fixtures:
2P TWO POLE
a. All lighting fixtures shall be furnished by owner and installed by the contractors. Detail of fixture design when not standard
CONSTRUCTION NOTES: shall be shown in the architectural drawings.
b. Fluorescent fixtures if any shall be complete set with lamps and ballast of high quality, Philips G.Ephilec or approved equal.
1. FINAL LOCATIONS OF CONVENIENCE OUTLETS SHALL BE DETERMINED DURING CONSTRUCTION.
LOCATION OF CONDENSING UNIT FOR SPLIT TYPE AIR CONDINTIONING SHALL BE COORDINATED WITH AIRCON 8. Wires and cables:
2. SUPPLIER
a. Wire shall be Phelps dodge, durafex, far east wires or approve equivalent
3. PROVIDE NEMA-3R PANEL WITH CIRCUIT BREAKER FOR ACCU.
4. ALL SMOKE DETECTORS SHALL BE CONNECTE TO EXISTING BUILDINGS FIRE ALARMS SYSTEM.
b. No wire shall be drawn into a raceway until it is complete with all necessary fittings, boxes supports. Connections shall be
securely fastened such as not to loosen under vibration and normal strain. All connections, splices shall be made approved
5. LOCATION OF TELEPHONE AND DATA OUTLET SHALL BE COORDINATED WITH THE OWNER
methods.
SEAL PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE: APPROVED BY: SHEET CONTENTS: DRAWN BY: DRAWING NUMBER
REF.NO. DATE:
PROPOSED CONSTRUCTION OF ONE-STOREY
DATE: