02 Sip 5
02 Sip 5
02 Sip 5
modules
new
PS 201
CB 202
Life Contact
Busbar compartment
Breaker compartment
Busbar compartment
Breaker compartment
Cable connection
compartment
Busbar compartment
Breaker compartment
Cable connection
compartment
7SA82
Fault recorder
7SA84 7SJ82
7SJ85
7SA86 Distance protection Overcurrent protection 7SJ86
7SA87
7SD82
7SD84 Line Motor 7SK82
7SD86
7SD87
differential protection
7SK85
7SL82
Combined distance Bay 6MD85
7SL86
7SL87
controller 6MD86
& line differential
Breaker-
7UT82
7VK87
Management 7UT85
7UT86 Busbar protection
7UT87
Transformer differential protection &
Unrestricted © Siemens 2020
Page 44 Jul 2020 voltage regulator Zoran Ristanović / SI DG
SIPROTEC 5
Overcurrent protection
OC protection
7SJ85
(modular IO)
OC protection 7SJ82
(non-modular IO)
OC protection,
as line protection backup 7SJ86
(modular IO)
7SA82 7SD82 7SA86 7SD86 7SL86 7SJ86 7SA87 7SD87 7SL87 7VK87
3-pole tripping ■ ■ ■ ■ ■ ■
1-/3-pole tripping ■ ■ ■ ■
Distance Protection ■ ■ ■
Circuit-breaker Management ■
Larger units
Large hardware
7UM85
(e.g. 16 I and 8V)
Application range
• Single busbar
• Double busbar / single breaker
• Triple busbar
• Double busbar with combined bus
• Double busbar with transfer bus
• 1 ½ circuit-breaker arrangement
• Double busbar / double breaker (1 or 2 CT)
• H- and T-circuits arrangements
• Ring bus, meshed corner
Protection functions
• 87B Phase-selective differential protection
• 50BF Breaker fail protection 1/3pole or 3pole
• 50EF End fault protection for feeders and couplers
• 62BF Breaker fail protection with no current
monitoring
• 50/87B Sensitive operate curve
• 50/74 Current transformer supervision
• 74TC Trip circuit supervision
• 50BFinh. Inherent breaker fail protection 3pole for
busbar faults
• 27/59 Under- / Overvoltage protection
• 81>< Frequency protection
• 50/51(N) Overcurrent protection 3 phase (ground) per bay
Protection functions
• Cross stabilization
• Bus coupler differential protection
• 21T Impedance protection
• 67/67N Directional overcurrent protection
phase/ground
System features
• 20 current measuring points (3-ph CT sets)
• 26 bays (feeder, coupler, sectionalizer)
• 6 (4 until V7.5x) bus zones
• 4 coupler
• 4 voltage measuring points (3-ph VT sets)
• Very short tripping time (<10ms)
• Integrated check zone as additional trip criterion
• High stability for external faults
(CT saturation-free time 2ms)
• Graphical engineering, configuration, and operation
with DIGSI5
• Comprehensive supervision and control functions
• Online substation monitoring (Single-line based) via display
or DIGSI5
• One 3-phase device for processing and HMI
Unrestricted © Siemens 2020
Page 54 Jul 2020 Zoran Ristanović / SI DG
Distributed Busbar Protection (max. 20 bays)
7SS85 + Merging Units: Basics
PRP LAN B
(optional for PRP)
• Selection according disconnector image, number bus
zones, functions points as before
(FPs for bays necessary)
6MU85 6MU85 7SJ85 7SA86 3rd party MU
• Process bus client functionality needs no additional
function points.
• 6MU85 Standard Variant AJ1 6MU85 6MU85 7SJ85 7SA86 3rd party MU
A lot more functions are available – table shows only the features which are different
between 6MD85 and 6MD86
• Simple
parameterization
• Reduced investment
having full
redundancy
Up to 40% savings
Total Cost with redundancy
• Simple
parameterization
• Faster commissioning
• Simple
parameterization
• Faster
More than 25% savings commissioning
siemens.com