Factory Automation Cable

KIC-35 (BE)
KIC-35 (R)
Oil and heat resistant PVC multi-conductor cables

UL AWM 2464
Characteristics Radar Chart
Heat resistance
Features
5 ■ Cables designed to UL, cUL standards and GOST-R

Cable carrier 4 ■ Oil resistance/Heat resistance/Flexibility


Oil resistance
resistance 3

1 Application
0
left/right ■ Internal/external cable connection to electrical equipment
bending Noise
resistance ■ Cable connection under oil environment
resistance

45°left/right vibration
Twist resistance
Certification/Marking
resistance

KIC-35(BE)、KIC-35(R) General VCTF


※The characteristics of the cable indicated on the radar chart are intended for
use as a general guide for selecting the cable meeting your requirements.

Technical Data
UL・cUL
Cable Type AWM Style 2464
Voltage Rating 300V
Temperature Rating 80℃
Test Voltage AC2000V・1min
Flame Resistance VW-1, FT1
Applicable Standard UL 758, CAN/CSA-C22.2 No210.2

Electrical Characteristics
Conductor Size Number of Cores Allowable Current(A)
Item
(AWG) 8∼51 8 11 15 21 25 31 41 51
Conductor Resistance(20℃)
18 22.2 10 9 8 7 7 6 6 5
Ω/Ü or below

Insulation Resistance(20℃) ●The conductor resistance of 14AWG (earth wire) is 8.83Ω/Ü or below at 20℃.
18, 14 10
MΩÜ or above

●Allowable Current (A) for the cable is based on calculation under aerial one-cable installation at ambient tempera-
ture of 30℃, not representing a guaranteed value.
Allowable current for the cable at ambient temperature above 30℃ is to be determined by multiplying the current
value by the appropriate current reduction factor specified in the following table for the ambient temperature.
●The Allowable current values are those calculated by JCS197, but not guaranteed.
JCS197… Japanese Electric Wire and Cable Makers’Association’
s Standard“Allowable Current for Cabtyre Cable”

■ Current Reduction Factor Table


Ambient Temperature(℃) 30 35 40 45 50 55 60 65 70 75
Current Reduction Factor 1.00 0.95 0.89 0.84 0.77 0.71 0.63 0.55 0.45 0.32

109
Core Identification
Number of cores Core identification system
Identification by number
8 or more
( marked on insulator surface in the order of
1, 2, 3, 4 and so on
)
●The cable code is identified by the cable insulator color:
Blue for KIC-35 (BE)
Red for KIC-35 (R)
●Green/yellow: Yellow straight lines on green (in green/yellow color ratio of 60/40)

Cable Construction
Item Configuration
Conductor Soft annealed stranded copper
Insulator Heat resistant PVC (blue or red)
Conductor stranding Circular

KIC-35(R)
KIC-35(BE)
Core wrapping tape Tape wrap around cores
Sheath Oil resistant/heat resistant PVC (light gray)

■ Example: 8 core (7 core (18AWG) + 1 core (14AWG)) cable


Oil resistant/heat resistant PVC sheath
Soft annealed stranded copper conductor
2 1

KIC-35(BE) KURAMO E162205-K AWM STYLE 2464 Ⅰ A 80C 300V VW-1 FT1 GOST-R LF
54 3

Tape
Heat resistant PVC insulator

Cable Outside Diameter/Weight


Conductor Size AWG Number of Cores
Conductor count/wire diameter 8 11 15 21 25 31 41 51
9.1 11.5 12.5 14.0 15.0 16.0 18.5 21.0
18 (35/0.18)
140 185 240 315 365 440 565 735
●The cable designed with its number of cores as indicated in the above table con- Upper: Standard cable outside diameter(Approx.Ù)
tains one core of 14AWG (41/0.26) green/yellow grounding conductor. Lower: Approximate weight(è/Ü)
※ indicates specifications for custom order production.
<PS>E
UL AWM
NFPA79
NFPA70
CE
CCCcUL/CSA
GOST-R

110