Factory Automation Cable

CE-36(BE)
UL AWM 2464
Characteristics Radar Chart
Heat resistance
5

4
Cable carrier Oil resistance
resistance 3

2 Features
1 ■ Global-standard cables designed to CE&UL・cUL&GOST-R
0 ■ Oil resistance/Heat resistance (105℃)/Flexibility
left/right
Noise
bending
resistance
resistance

Application
■ Internal/external cable connection to electrical equipment
45°left/right vibration
Twist resistance ■ Cable connection under oil environment
resistance

CE-36(BE) General VCTF


※The characteristics of the cable indicated on the radar chart are intended for Certification/Marking
use as a general guide for selecting the cable meeting your requirements.

Technical Data
CE UL・cUL
Voltage Rating 300/300V 300V
Temperature Rating 70℃ 80℃
Test Voltage AC2000V・15min AC3000V・1min
Flame Resistance VDE0482 Teil 265-2-1 VW-1, FT1
Applicable Standard VDE0281-13 UL 758 AWM Style 2464 CAN/CSA-C22.2 No210.2

Electrical Characteristics
Nominal Cross-Sectional Number of Cores Allowable Current(A)
Item
Area(Ý)(AWG) 2∼51 2 3 4 5 7 8 9 11 13 17 21 25 31 41 51
0.5 (20) 34.3 11 11 10 9 8 7 7 6 6 5 5 5 4 4 4

Conductor Resistance 0.75(18) 22.2 14 14 13 11 10 10 9 8 8 7 7 6 6 5 5


(20℃) 1 (18) 19.5 15 15 14 12 11 10 10 9 8 8 7 7 6 6 5
Ω/Ü or below 1.5 (16) 13.3 19 19 17 15 14 13 12 11 11 10 9 8 8 7 7
2.5 (14) 7.98 27 27 23 21 19 18 17 16 15 14 13 12 11 10 9

Insulation Resistance
(20℃) 0.5(20)∼2.5(14) 10
MΩÜ or above
●Thecable designed with its number of cores of 3 or more as indicated in the above table contains one core of 2.5Ý (14AWG) (50/0.25) green/yellow grounding conductor.
●The conductor resistance of the 2.5Ý (14AWG) green/yellow grounding conductor is 7.98Ω/km or less at 20℃.
●The insulation resistance of the 2.5Ý (14AWG) green/yellow grounding conductor is 10 MΩkm or more at 20℃.

●Allowable Current (A) for the cable is based on calculation under aerial one-cable installation at ambient temper-
ature of 30℃, not representing a guaranteed value.
Allowable current for the cable at ambient temperature above 30℃ is to be determined by multiplying the current
value by the appropriate current reduction factor specified in the following table for the ambient temperature.
●The Allowable current values are those calculated by JCS197, but not guaranteed.

( For details on Allowable current of the cable when used in Europe, refer to the applicable standard
− IEC60364-5 (Electrical installation of building − Part 5: Selection and erection of electrical equip-
ment − Section 523: Current-carrying capacities in wiring system).
)
JCS197… Japanese Electric Wire and Cable Makers’Association’
s Standard“Allowable Current for Cabtyre Cable”

■ Current Reduction Factor Table


Ambient Temperature(℃) 30 35 40 45 50 55 60 65
Current Reduction Factor 1.00 0.94 0.87 0.79 0.71 0.61 0.5 0.35

95
Core Identification
Core identification system

Identification by 2cores − Identified by numbering in white color on blue insulator surface


Number 3cores or more − Identified by numbering in white color on blue insulator surface + green/yellow

●Green/yellow: Yellow straight lines on green (in green/yellow color ratio of 60/40)

Cable Construction
Item Configuration
Conductor Soft annealed stranded copper
Insulator Heat resistant PVC
Conductor stranding Circular
Core wrapping tape Tape wrap around cores if their number is 4 or more
Sheath Oil resistant/heat resistant PVC (light gray)

CE-36(BE)
■Example: 8 core (7 core (2.5Ý)14AWG + 1 core (2.5Ý)14AWG) cable
Soft annealed stranded copper conductor Oil resistant/heat resistant PVC sheath
2.5Ý grounding conductor
2 1

CE-362(BE)KURAMO 300/500V
CE-36(BE)KURAMO-K VDE Reg.-Nr. 7898 300/300V
KURAMO E162205 AWM STYLE 2587 Ⅰ/Ⅱ A/B 90C 600V VW-1 FT1
KURAMO E162205-K AWM STYLE 2464 Ⅰ A 80C 300V VW-1 FT1 GOST-R LF
54 3

VCTF <PS>E JET タイネツ 300V GOST-R LF

Tape
Heat resistant PVC insulator

Cable Outside Diameter/Weight


Nominal cross-sectional area(Ý)<AWG> Number of Cores
Conductor count/wire diameter 2 3 4 9 115 13 7
17 21 8 25 31 41 51
0.5 (22/0.18) 5.6 7.1 7.3 10.0 7.7
10.5 11.0 11.5
8.9 13.0 13.0
8.3 15.0 17.0 18.0
※ ※ ※ ※ ※
<20> 45 80 90 150 100
150 175 210
115 250 130 270 340 430 520
0.75(35/0.18) 6.0 7.3 7.7 11.0 8.2
11.5 11.5 12.5
9.4 14.5 15.5
10.5 16.5 18.5 21.0
※ ※ ※ ※ ※ ※
<18> 55 86 100 170 115
195 215 270
140 330 160 375 450 580 740
1 (40/0.18) 6.3 7.4 7.9 11.0 8.4
12.0 12.0 13.5
9.6 15.0 16.0
10.5 17.0 19.5 21.5
※ ※ ※ ※ ※ ※ ※
<18> 60 90 105 180 120
210 235 290
150 360 165 415 495 640 800
1.5 (60/0.18) 7.1 7.9 8.5 12.5 9.3
12.5 13.5 15.5
11.0 17.0 18.0
12.0 19.5 23.0 25.0
※ ※ ※ ※ ※
<16> 75 105 125 235 145
265 310 400
185 485 210 560 690 920 1110
2.5 (50/0.25) 8.7 9.0 9.9 15.5 11.0
16.0 16.5 19.0
13.0 22.0 23.0
14.5 25.0 29.0 31.5
※ ※ ※ ※ ※ ※ ※
<14> 120 140 165 345 200
410 475 610
270 770 310 890 1090 1460 1770
●The cable designed with its number of cores of 3 or more as indicated in the above Upper: Standard cable outside diameter(Approx.Ù)
Lower: Approximate weight(è/Ü)
<PS>E

table contains one core of 2.5Ý (14AWG) (50/0.25) green/yellow grounding conductor.
※ indicates specifications for custom order production.
UL AWM
NFPA79
NFPA70
CE
CCCcUL/CSA
GOST-R