PVG 32 Technical Information

Download as pdf or txt
Download as pdf or txt
You are on page 1of 76

Technical Information

Proportional Valve Group


PVG 32

powersolutions.danfoss.com
Technical Information
PVG 32 Proportional Valve Group

Revision history Table of revisions

Date Changed Rev

March 2016 Pressure-compensated PVB, open center PVP; Characteristics for float position 0801
main spools.

March 2016 Updated for Engineering Tomorrow design. 0710

August 2015 PVPX modules description updated 0709

June 2015 Oil consumption corrected HH

November 2014 Drawings adjusted in size HG

May 2014 Fluid consumption change page 30 HF

February 2014 Spec. sheet update HE

January 2014 Converted to Danfoss layout – DITA CMS HD

February 2006 - Aug 2013 Various changes BA - HC

January 2005 New Edition AA

2 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Contents

General description
Features of PVG 32........................................................................................................................................................................... 5
PVG modules .....................................................................................................................................................................................5
PVP, pump side modules..........................................................................................................................................................5
PVB, basic modules.....................................................................................................................................................................5
Actuation modules..................................................................................................................................................................... 6
Remote control units ......................................................................................................................................................................6
PVG 32 with open center PVP...................................................................................................................................................... 7
PVG 32 with closed center PVP....................................................................................................................................................8
PVG 32 sectional view.....................................................................................................................................................................9
Load sensing for variable displacement pump supply.......................................................................................................9
Safety in application
Control system example..............................................................................................................................................................12
Examples of wiring block diagram..................................................................................................................................... 14
Function
Load sensing controls...................................................................................................................................................................16
LS control with bleed orifice (do not use with PVG valves).......................................................................................16
Integral PC function................................................................................................................................................................. 16
Load sensing system characteristics:.................................................................................................................................16
Remote pressure compensated controls.............................................................................................................................. 16
Remote pressure compensated system characteristics:............................................................................................ 17
Typical applications for remote pressure compensated systems:..........................................................................17
PVG 32 main spool with pressure compensated control................................................................................................ 17
Pressure compensated system characteristics.............................................................................................................. 18
Typical applications for pressure compensated systems...........................................................................................18
PVPC adapter for external pilot oil supply............................................................................................................................ 18
PVPC with check valve for open center PVP................................................................................................................... 18
PVPC without check valve for open or closed center PVP.........................................................................................19
PVMR, friction detent....................................................................................................................................................................21
PVMF, mechanical float position lock.....................................................................................................................................21
PVBS, main spools for flow control (standard).................................................................................................................... 21
PVBS, main spools for flow control (linear characteristic)............................................................................................... 21
PVBS, main spools for pressure control................................................................................................................................. 22
Background.................................................................................................................................................................................22
Principle....................................................................................................................................................................................... 22
Application..................................................................................................................................................................................23
Sizing.............................................................................................................................................................................................23
Limitation.................................................................................................................................................................................... 24
PVPX, electrical LS unloading valve.........................................................................................................................................24
PVG 32 technical data
PVH, hydraulic actuation............................................................................................................................................................. 26
PVM, mechanical actuation........................................................................................................................................................26
PVE, electrical actuation.............................................................................................................................................................. 26
PVPX, electrical LS unloading valve.........................................................................................................................................29
Electrical actuation
Electrical control of PVG.............................................................................................................................................................. 30
Closed loop control....................................................................................................................................................................... 31
PVEO................................................................................................................................................................................................... 32
PVEM...................................................................................................................................................................................................32
PVEA, PVEH, PVES, PVEU.............................................................................................................................................................. 33
PVEP.................................................................................................................................................................................................... 33
PVED-CC and PVED-CX.................................................................................................................................................................33
PVHC................................................................................................................................................................................................... 34
Technical characteristics
General...............................................................................................................................................................................................36
PVP, pump side module.............................................................................................................................................................. 36

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 3


Technical Information
PVG 32 Proportional Valve Group

Contents

PVB, basic modules oil flow characteristics.......................................................................................................................... 36


Pressure-compensated PVB, open center PVP ..............................................................................................................37
PVB without pressure compensation, open center PVP.............................................................................................38
PVB without pressure compensation, closed center PVP.......................................................................................... 39
PVLP, shock and PVLA, suction valves...............................................................................................................................41
Pressure build-up for pressure controlled spools.........................................................................................................41
Pressure control spool flow characteristics.......................................................................................................................... 41
Examples of how to use the characteristics for pressure control spools...................................................................42
Characteristics for float position main spools..................................................................................................................... 43
Hydraulic systems
Manually actuated PVG 32 – fixed displ. pump.................................................................................................................. 45
Electrically actuated PVG 32 – variable displ. pump......................................................................................................... 46
Other operating conditions
Oil.........................................................................................................................................................................................................47
Particle content, degree of contamination...........................................................................................................................47
Filtration............................................................................................................................................................................................ 47
Dimensions
PVM, control lever positions...................................................................................................................................................... 50
Surface treatment.......................................................................................................................................................................... 51
Modules symbols, description and code numbers
PVP, pump side modules.............................................................................................................................................................52
PVB, basic modules........................................................................................................................................................................54
PVLA, suction valve (fitted in PVB)........................................................................................................................................... 56
PVLP, shock and suction valve (fitted in PVB)...................................................................................................................... 56
PVM, mechanical actuation........................................................................................................................................................57
PVH, hydraulic actuation............................................................................................................................................................. 58
PVS, end plate..................................................................................................................................................................................58
PVAS, assembly kit.........................................................................................................................................................................58
PVPX, electrical LS unloaded valve.......................................................................................................................................... 59
PVPC, plug for external pilot oil supply..................................................................................................................................59
Module selection chart
Standard FC spools........................................................................................................................................................................60
Standard FC spools, hydraulic actuation...............................................................................................................................61
FC spools for mechanical float position, PVMF................................................................................................................... 61
FC spools for friction detent, PVMR.........................................................................................................................................62
FC spools with linear flow characteristic .............................................................................................................................. 62
Standard PC spools .......................................................................................................................................................................63
Standard PC spools, hydraulic actuation...............................................................................................................................64
PVB, basic valves.............................................................................................................................................................................65
PVP, pump side module.............................................................................................................................................................. 66
PVE, electrical actuation.............................................................................................................................................................. 68
Order specification
Standard and option assembly................................................................................................................................................. 70
Reordering........................................................................................................................................................................................70
Pressure setting limits.................................................................................................................................................................. 70
PVG 32 specification sheet......................................................................................................................................................... 72

4 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

General description

PVG 32 is a hydraulic load sensing valve designed to give maximum flexibility. From a simple load sensing
directional valve, to an advanced electrically controlled load-independent proportional valve.
The PVG 32 modular system makes it possible to build up a valve group to meet requirements precisely.
The compact external dimensions of the valve remain unchanged whatever combination is specified.

Features of PVG 32
• Load-independent flow control:
‒ Oil flow to an individual function is independent of the load pressure of this function
‒ Oil flow to one function is independent of the load pressure of other functions
• Good regulation characteristics
• Energy-saving
• Up to 12 basic modules per valve group
• Several types of connection threads
• Low weight
• Compact design and installation

PVG modules

PVP, pump side modules


• Built-in pressure relief valve
• Pressure gauge connection
• Versions:
‒ Open center version for systems with fixed displacement pumps
‒ Closed center version for systems with variable displacement pumps
‒ Pilot oil supply for electrical actuator built into the pump side module
‒ Pilot oil supply for hydraulic actuation built into the pump side module
‒ Versions prepared for electrical LS unloading valve PVPX

PVB, basic modules


• Interchangeable spools
• Depending on requirements the basic module can be supplied with:
‒ Integrated pressure compensator in channel P
‒ Load holding check valve in channel P
‒ Shock/suction valves for A and B ports

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 5


Technical Information
PVG 32 Proportional Valve Group

General description

‒ LS pressure limiting valves individually adjustable for ports A and B


‒ Different interchangeable spool variants
‒ All versions suitable for mechanical, hydraulic and electrical actuation

Actuation modules
The basic module is always fitted with mechanical actuator PVM and PVMD, which can be combined with
the following as required:
• Electrical actuator (11 - 32 V ===):
‒ PVES – proportional, Super
‒ PVEH – proportional, High performance
‒ PVEH-F – proportional high performance, Float
‒ PVEA – proportional low hysteresis
‒ PVEM – proportional, Medium performance
‒ PVEO – ON/OFF
‒ PVEU – proportional, voltage control, 0-10 V
‒ PVED-CC – Digital CAN controlled J1939/ISOBUS
‒ PVED-CX – Digital CAN controlled CANopen X-tra safety
‒ PVEP – PWM voltage controlled (11-32 V)
‒ PVHC – High Current actuator for PVG
• PVMR, cover for Mechanical detent
• PVMF, cover for Mechanical Float
• PVH, cover for Hydraulic actuation

Remote control units


• Electrical remote control units:

‒ PVRE, PVRET ‒ JS1000 Ball grip


‒ PVREL ‒ JS1000 PRO grip
‒ PVRES ‒ JS2000
‒ Prof 1 ‒ JS6000
‒ Prof 1 CIP ‒ JS7000
‒ JS120
• Hydraulic remote control unit: PVRHH

6 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

General description

Electrical and hydraulic remote control units

PVRE, electrical control unit, 162F… PVRH, hydraulic control unit, 155N…

155N0003 155N0001 155N0004 155N0005 155N0002

PVREL, electrical control unit, 155U… PVRES, electrical control unit, 155B…

Prof 1, 162F…

PVG 32 with open center PVP


PVG 32 with open center PVP (fixed displacement pump) and PVB with flow control spool.
When the pump is started and the main spools in the individual basic modules (11) are in the neutral
position, oil flows from the pump, through connection P, across the pressure adjustment spool (6) to
tank.
The oil flow led across the pressure adjustment spool determines the pump pressure (stand-by pressure).
When one or more of the main spools are actuated, the highest load pressure is fed through the shuttle
valve circuit (10) to the spring chamber behind the pressure adjustment spool (6), and completely or
partially closes the connection to tank to maintain pump pressure.
Pump pressure is applied to the right-hand side of the pressure adjustment spool (6).
The pressure relief valve (1) will open should the load pressure exceed the set value, diverting pump flow
back to tank.
In a pressure-compensated basic module the compensator (14) maintains a constant pressure drop
across the main spool – both when the load changes and when a module with a higher load pressure is
actuated.
With a non pressure-compensated basic module incorporating a load drop check valve (18) in channel P,
the check valve prevents return oil flow.
The basic module can be supplied without the load drop check valve in channel P for functions with over-
center valves.
The shock valves PVLP (13) with fixed setting and the suction valves PVLA (17) on ports A and B are used
for the protection of the individual working function against overload and/or cavitation.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 7


Technical Information
PVG 32 Proportional Valve Group

General description

An adjustable LS pressure limiting valve (12) can be built into the A and B ports of pressure-compensated
basic modules to limit the pressure from the individual working functions. Please see the sectional
drawingPVG 32 sectional view on page 9 below for better understanding of this example.
The LS pressure limiting valves save energy compared with the shock valves PVLP:
• with PVLP all the oil flow to the working function will be led across the combined shock and suction
valves to tank if the pressure exceeds the fixed setting.
• with LS pressure limiting valves an oil flow of about 2 l/min [0.5 US gal/min] will be led across the LS
pressure limiting valve to tank if the pressure exceeds the valve setting.

PVG 32 with closed center PVP


PVG 32 with closed center PVP (variable displacement pump) and PVB with flow control spool.
In the closed center version of PVP an orifice (5) and a plug (7) have been fitted instead of the plug (4).
This means that the pressure adjustment spool (6) will only open to tank when the pressure in channel P
exceeds the set value of the pressure relief valve (1).
In load sensing systems the load pressure is led to the pump control via the LS connection (8).
In the neutral position the pump load sense control sets the displacement so that leakage in the system is
compensated, to maintain the set stand-by pressure.
When a main spool is actuated the pump load sense control will adjust the displacement so that the set
differential pressure (margin) between P and LS is maintained.
The pressure relief valve (1) in PVP should be set at a pressure of approx. 30 bar [435 psi] above maximum
system pressure (set on the pump or external pressure relief valve).

8 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

General description

PVG 32 sectional view

1 2
T P

3
M

PVP
4 5
LS A
8

9
12 7 B A 6 13

T T
11

PVB 10

LS B P LS A
14 16 B A 17 15

B
T T

PVB

19 18 20 V310106.A

1. Pressure relief valve 11. Main spool


2. Pressure reduction valve for pilot oil supply 12. LS pressure limiting valve
3. Pressure gauge connection 13. Shock and suction valve, PVLP
4. Plug, open center 14. Pressure compensator
5. Orifice, closed center 15. LS connection, port A
6. Pressure adjustment spool 16. LS connection, port B
7. Plug, closed center 17. Suction valve, PVLA
8. LS connection 18. Load drop check valve
9. LS signal 19. Pilot oil supply for PVE
10. Shuttle valve 20. Maximum oil flow adjustment screws for A/B ports

Load sensing for variable displacement pump supply


The pump receives fluid directly from the reservoir through the inlet line. A screen in the inlet line
protects the pump from large contaminants.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 9


Technical Information
PVG 32 Proportional Valve Group

General description

The pump outlet feeds directional control valves such as PVG-32, hydraulic integrated circuits (HIC), and
other types of control valves.
The PVG valve directs and controls pump flow to cylinders, motors and other work functions. A heat
exchanger cools the fluid returning from the valve. A filter cleans the fluid before it returns to the
reservoir.
Flow in the circuit determines the speed of the actuators. The position of the PVG valve spool determines
the flow demand. A hydraulic pressure signal (LS signal) communicates demand to the pump control.
The pump control monitors the pressure differential between pump outlet and the LS signal, and
regulates servo pressure to control the swashplate angle. Swashplate angle determines pump flow.
Actuator load determines system pressure. The pump control monitors system pressure and will decrease
the swashplate angle to reduce flow if system pressure reaches the pump control setting.
A secondary system relief valve in the PVG valve acts as a back-up to control system pressure.
Pictorial circuit diagram
8
7

10

1
2
13
12 3
11
4
5
6
P101 658E

10 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Safety in application

All makes and all types of control valves (incl. proportional valves) can fail, thus the necessary protection
against the serious consequences of function failure should always be built into the system. For each
application an assessment should be made for the consequences of pressure failure and uncontrolled or
blocked movements.
To determine the degree of protection that is required to be built into the application, system tools such
an FMEA (Failure Mode and Effect Analysis) and Hazard and Risk Analysis can be used.

FMEA – IEC EN 61508


FMEA (Failure Mode and Effect Analysis) is a tool used for analyzing potential risks. This analytical
technique is utilized to define, identify, and prioritize the elimination or reduction of known and/or
potential failures from a given system before it is released for production. Please refer to IEC FMEA
Standard 61508.

Hazard and risk analysis ISO 12100-1 / 14121


This analysis is a tool used in new applications as it will indicate whether there are special safety
considerations to be met according to the machine directives EN 13849. Dependent on the determined
levels conformity this analysis will detirmine if any extra requirements for the product design,
development process, production process or maintenance, i.e. the complete product life cycle.

W Warning
All makes/brands and types of directional control valves – inclusive proportional valves – can fail and
cause serious damage. It is therefore important to analyze all aspects of the application.

Because the proportional valves are used in many different operation conditions and applications,
the manufacturer of the application is alone responsible for making the final selection of the products –
and assuring that all performance, safety and warning requirements of the application are met.

The process of choosing the control system – and safety levels – is governed by the machine directives
EN 13849 (Safety related requirements for control systems).

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 11


Technical Information
PVG 32 Proportional Valve Group

Safety in application

Control system example


Example of a control system for manlift using PVE Fault monitoring input signals and signals from external
sensors to ensure the PLUS+1® main controllers correct function of the manlift.

Legend:
1 – Main power supply
2 – Emergency stop/man present switch
3 – HMI/Joystick control
4 – Movement detection sensors
5 – Main controller
6 – PVG control valve
7 – Hydraulic deactivation

12 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Safety in application

Electrical block diagram for the above illustration

W Warning

It is the responsibility of the equipment manufacturer that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.

PVG 32 – mainly used in system with fixed displacement pumps:


• PVSK, commonly used in crane application - full flow dump
• PVPX, LS dump to tank
PVG 100 – alternative LS dump or pilot supply disconnect:
• PVPP, pilot oil supply shut off
• External cartridge valve connecting LS pressure or main pressure to tank
PVG 120 – pump disconnect / block for variable pumps:
• PVPE, full flow dump for the PVG 120
• External cartridge valve connecting LS pressure to tank

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 13


Technical Information
PVG 32 Proportional Valve Group

Safety in application

Examples of wiring block diagram


Example of a typical wiring block diagram using PVEH with neutral power off switch and fault monitoring
output for hydraulic deactivation.
Emergency Man present
stop switch
A

PVE 1 Neutral detection / Supply control PVEH


1) with AMP
C signal connector
OFF
≠ Delay US
neutral UDC2

B Error

PVE 2 Neutral detection / Supply control PVEH


1) with AMP
C signal connector
OFF
≠ Delay US
neutral UDC2

B Error

E1 E2
2) Alarm
logic
Output
OR

3) Memory

high=on
AND

low=off

Hydraulic
Fault detection output D deactivation

P301 318

A– Emergency stop / man present switch


B– PVE Fault monitoring signals
C– Neutral signal detection.
D– Hydraulic deactivation
System Control Logic e.g. PLUS+1® for signal monitoring and triggering signal for deactivation of the
hydraulic system.

W Warning

It is the responsibility of the equipment manufacturer that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.

14 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Safety in application

Example of fault monitoring for deactivation of the hydraulic system with extra fault inputs using the PVE’s
with DI (Direction Indication) function.
Emergency Man present
Stop switch

PVE 1 Neutral detection / Supply control PVEH-DI


1) AMP supply
signal connector
OFF
≠ Delay US
neutral UDC2

Error

PVEH-DI
AMP connector
2) Fault detection DI-A
DI-B 3) 4) DI-B
DI-A DI Output Delay Memory
US Logic Error

PVE 2 Neutral detection / Supply control PVEH-DI


1) AMP supply
signal connector
OFF US
≠ Delay
neutral UDC2

Error

PVEH-DI
AMP connector
Fault detection DI-A
2)
DI-B 3) 4)
DI-A DI Output Delay Memory
US Logic Error
OR

AND

high=on
low=off

Hydraulic
Fault detection output deactivation

P301 319

System Control Logic e.g. PLUS+1® for signal monitoring and triggering signal for deactivation of the
hydraulic system.

W Warning

It is the responsibility of the equipment manufacturer that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 15


Technical Information
PVG 32 Proportional Valve Group

Function

Load sensing controls


The LS control matches system requirements for both pressure and flow in the circuit regardless of the
working pressure. Used with a closed center control valve, the pump remains in low-pressure standby
mode with zero flow until the valve is opened. The LS setting determines standby pressure.

Typical operating curve Load sensing circuit

Q max
Flow

0 PC setting
0 Pressure
P101 968E

P101 967

Most load sensing systems use parallel, closed center, control valves with special porting that allows the
highest work function pressure (LS signal) to feed back to the LS control.
Margin pressure is the difference between system pressure and the LS signal pressure. The LS control
monitors margin pressure to read system demand. A drop in margin pressure means the system needs
more flow. A rise in margin pressure tells the LS control to decrease flow.

LS control with bleed orifice (do not use with PVG valves)
The load sense signal line requires a bleed orifice to prevent high-pressure lockup of the pump control.
Most load-sensing control valves include this orifice. An optional internal bleed orifice is available, for use
with control valves that do not internally bleed the LS signal to tank.

Integral PC function
The LS control also performs as a PC control, decreasing pump flow when system pressure reaches the PC
setting. The pressure compensating function has priority over the load sensing function.

For additional system protection, install a relief valve in the pump outlet line.

Load sensing system characteristics:


• Variable pressure and flow
• Low pressure standby mode when flow is not needed
• System flow adjusted to meet system requirements
• Lower torque requirements during engine start-up
• Single pump can supply flow and regulate pressure for multiple circuits
• Quick response to system flow and pressure requirements

Remote pressure compensated controls


The remote PC control is a two-stage control that allows multiple PC settings. Remote PC controls are
commonly used in applications requiring low and high pressure PC operation.

16 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Function

Typical operating curve Closed center circuit with remote PC

Q max

Flow

Remote PC setting

PC setting
0
0 Pressure P101 969E
P101 966

The remote PC control uses a pilot line connected to an external hydraulic valve. The external valve
changes pressure in the pilot line, causing the PC control to operate at a lower pressure. When the pilot
line is vented to reservoir, the pump maintains pressure at the load sense setting.
When pilot flow is blocked, the pump maintains pressure at the PC setting. An on-off solenoid valve can
be used in the pilot line to create a low-pressure standby mode. A proportional solenoid valve, coupled
with a microprocessor control, can produce an infinite range of operating pressures between the low
pressure standby setting and the PC setting.

Size the external valve and plumbing for a pilot flow of 3.8 l/min [1 US gal/min]. For additional system
protection, install a relief valve in the pump outlet line.

Remote pressure compensated system characteristics:


• Constant pressure and variable flow
• High or low pressure standby mode when flow is not needed
• System flow adjusts to meet system requirements
• Single pump can provide flow to multiple work functions
• Quick response to system flow and pressure requirements

Typical applications for remote pressure compensated systems:


• Modulating fan drives
• Anti-stall control with engine speed feedback
• Front wheel assist
• Road rollers
• Combine harvesters
• Wood chippers

PVG 32 main spool with pressure compensated control


The PC control maintains constant system pressure in the hydraulic circuit by varying the output flow of
the pump. Used with a closed center control valve, the pump remains in high pressure standby mode at
the PC setting with zero flow until the function is actuated.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 17


Technical Information
PVG 32 Proportional Valve Group

Function

Typical operating curve Simple closed center circuit


Q max

Flow

PC setting
0
0 Pressure P101 166E

P101 965

Once the closed center valve is opened, the PC control senses the immediate drop in system pressure
and increases pump flow by increasing the swashplate angle.
The pump continues to increase flow until system pressure reaches the PC setting.
If system pressure exceeds the PC setting, the PC control reduces the swashplate angle to maintain
system pressure by reducing flow. The PC control continues to monitor system pressure and changes
swashplate angle to match the output flow with the work function pressure requirements.
If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum
displacement. In this condition, actual system pressure depends on the actuator load.

For additional system protection, install a relief valve in the pump outlet line.

Pressure compensated system characteristics


• Constant pressure and variable flow
• High pressure standby mode when flow is not needed
• System flow adjusts to meet system requirements
• Single pump can provide flow to multiple work functions
• Quick response to system flow and pressure requirements

Typical applications for pressure compensated systems


• Constant force cylinders (bailers, compactors, refuse trucks)
• On/off fan drives
• Drill rigs
• Sweepers
• Trenchers

PVPC adapter for external pilot oil supply

PVPC with check valve for open center PVP


PVPC with check valve is used in systems where it is necessary to operate the PVG 32 valve by means of
the electrical remote control without pump flow. When the external solenoid valve is opened, oil from
the pressure side of the cylinder is fed via the PVPC through the pressure reducing valve to act as the
pilot supply for the electrical actuators. This means that a load can be lowered by means of the remote
control lever without starting the pump.
The built-in check valve prevents the oil from flowing via the pressure adjustment spool to tank. With the
pump functioning normally the external solenoid valve is closed to ensure that the load is not lowered

18 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Function

due to the pilot supply oil flow requirement of approximately 1 l/min [0.25 US gal/min]. With closed
center PVP the external pilot oil supply can be connected to the pressure gauge connection without the
use of a PVPC plug.
PVPC with check valve for OC PVP
T P

LS

157-114.11

Hydraulic diagram

PVPC without check valve for open or closed center PVP


PVPC without check valve is used in systems where it is necessary to supply the PVG 32 valve with oil
from a manually operated emergency pump without directing oil flow to the pilot oil supply (oil
consumption about 0.5 l/min) [0.13 US gal/min].
When the main pump is working normally, the oil is directed through the PVPC plug via the pressure
reduction valve to the electrical actuators.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 19


Technical Information
PVG 32 Proportional Valve Group

Function

PVPC without check valve OC/CC PVP


T P

LS

157-193.11

Hydraulic diagram

When the main pump flow fails, the external shuttle valve ensures that the oil flow from the manually
operated emergency pump is used to pilot open the over center valve and lower the load. The load can
only be lowered using the mechanical operating lever of the PVG 32 valve.

20 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Function

PVMR, friction detent

The friction detent PVMR allows the directional spool to


be held in any position, resulting in infinitely variable, PVMR, friction detent
reversible, pressure compensated flow.
This can be sustained indefinitely without having to
continue to hold the mechanical lever.
Friction detent spool position may be affected by high
differential actuator flow forces and system vibration
resulting in work function flow reduction.

PVMF, mechanical float position lock


Allows the float spool to be held in the float position after release of the mechanical handle.

PVMF, standard mount only PVMF, optional mount only

P → A → F (Push-in) P → A → F (Pull-out)

PVBS, main spools for flow control (standard)


When using standard flow control spools, the pump pressure is determined by the highest load pressure.
This is done either via the pressure adjustment spool in open center PVP (fixed displacement pumps) or
via the pump control (variable displacement pumps).
In this way the pump pressure will always correspond to the load pressure plus the stand-by pressure of
the pressure adjustment spool or the pump control. This will normally give optimum and stable
adjustment of the oil flow.

PVBS, main spools for flow control (linear characteristic)


PVBS main spools with linear characteristic have less dead band than standard spools and a proportional
ratio between control signal and oil flow in the range beyond the dead band. PVBS with linear
characteristic must never be used together with PVEM electrical actuators.
The interaction between the small dead band of the spools and the hysteresis of the PVEM actuator of
20% involves a risk of building up a LS pressure in neutral position.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 21


Technical Information
PVG 32 Proportional Valve Group

Function

In a few systems load sensing pump pressure may result in unstable adjustment of the oil flow and a
tendency towards system hunting.
This may be the case with working functions that have a large moment of inertia or over-center valves. In
such systems main spools for pressure control can be advantageous.

PVBS, main spools for pressure control


The spools are designed in such a way that the pump pressure is controlled by the spool travel. The main
spool must be displaced until the pump pressure just exceeds the load pressure before the working
function is applied. If the main spool is held in this position, the pump pressure will remain constant –
even if the load pressure changes – giving a stable system.
The use of pressure control spools, however, also means that:
• the oil flow is load dependent
• the dead band is load dependent
• the pump pressure can exceed the load pressure by more than is usual
• the pressure drop across main spool varies (energy consumption)

Due to these factors it is recommended that pressure control spools are only used when it is known for
certain that problems with stability will arise or already have arisen, and in applications where constant
pressure is needed e.g. drill holding.

Background
Instability in load sense control systems in certain applications with oscillations in the range of 1/2 - 2 Hz
can cause severe instability problems while trying to control functions in an application.
Critical applications are usually related to functions with an important inertia torque and/or functions
with secondarily fitted pressure controlled components e.g. over-center valves.
Examples:
• a slewing function
• main lifting/lowering function of a crane

The problem usually manifests itself in prolonged oscillation phenomena (Fig. 1), in a relatively constant
sequence of oscillations (Fig. 2) or in the worst case in an amplified sequence of oscillations (Fig. 3).

Fig. 1 Prolonged sequence Fig. 2 Constant sequence Fig. 3 Amplified sequence

P Prolonged sequence P Constant sequence P Amplified sequence

time time time


P005 627E

To control the oscillation phenomena the "pressure control spool" was developed and is a patented
system which can minimize most of the oscillation issues.

Principle
The idea was to create a system operating independently of a constantly changing load pressure.
Therefore, we changed the well-known LS principle (Fig. 4), so that compensated pump pressure is part
of the LS system (Fig. 5) after the pressure compensator and before the metering range of the main spool.
Upon actuation of the spool, it will be led via a fixed and a variable orifice.

22 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Function

Fig. 4 Flow controlled spool Fig. 5 Pressure controlled spool

A A

B B

P005 625 P005 626

The opening area of the variable orifice is at maximum at


initial actuation and 0 at full stroke of the spool and then Pump pressure vs. spool travel curve
the pressure created between the two orifices is led into
the LS system in the usual way.
In this way the pump pressure is built up depending on
the spool travel, e.g. the spool will then have to be
stroked to a position that the pump pressure is higher
than the actual load pressure to make the oil flow from
P➝A/B.
When the load changes for a fixed spool position the flow
to for the function will also change.
The valve section is now a load-dependent valve, but
ensuring a constant pump pressure which is important in
obtaining a stable function.

Application
Pressure controlled spools should in principle only be used when you have stability issues. Typical
applications on a crane:
• Lifting/lowering movement
• Slewing movement with cylinders
• For the main lifting/lowering function on a crane it is recommended to fit a "half" pressure control
spool. This means that the spool is designed with a normal flow control on the lifting port and
pressure control connected to the port where the pilot signal to the over-center valve is acting. You
will thus maintain a load-independent lifting movement and achieve a stable but load-depending
lowering movement.
• As the load pressure on slewing movements is usually steady - irrespective of the crane being loaded
or not – it will be advantageous to use a "full" pressure control spool for A and B port.

In both cases we recommend the use of a basic valve, PVB, with pressure compensator. The pressure
compensator will ensure the individual load-independency between the basic valves.
It is further recommended to use the LS pressure relief valves as not only will they ensure individual
pressure limitation but also make it possible to adjust the maximum oil flow to the function.
It is not recommended to use shock valves as pressure limiting valves in connection with pressure control
spools.

Sizing
The size of "half" (e.g: P - A = flow control P - B pressure control) pressure control spools is determined on
basis of max. flow demand on the lifting port. If e.g. a max. pressure compensated flow of 65 l/min for the
lifting movement, you choose a 65 L/min spool (size D). The metering characteristic has then a given size.
As it is often requested to limit the use of the crane boom for downward push/force mode and the LS

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 23


Technical Information
PVG 32 Proportional Valve Group

Function

pressure limitation can be used. It will appear from the characteristics enclosed what effect a pressure
limitation, PLS will have on max. flow on the lowering port.
The size for a "full" pressure control spool is determined on basis of known load pressure, PLS max, and
requested max. flow.
It will appear from the characteristics enclosed that if the load PLS is low and the pump pressure, Pp, is
high as a result of max. stroked spool you will get a large flow.
If PLS is approaching PLS max. the flow will be reduced and the dead band increased. Max. oil flow can be
reduced by approx. 50% without limiting max. pressure.
The reduction is made by limiting the spool travel from 7 mm to 5.5 mm.

Limitation
If a pressure controlled spool is chosen for stability reasons consideration should be made to features
related to the pressure control principle.
Deadband will change according to the load conditions and the valve section will become load-
dependent and that the pump pressure may exceed the load pressure.
With all of the above in mind, a “pressure controlled spool” will minimize oscillation and obtain a stable
function that can be controlled smooth and precise.

PVPX, electrical LS unloading valve


PVPX is a solenoid LS unloading valve. PVPX is fitted into the pump side module enabling a connection to
be made between the LS and the tank lines. Thus the LS signal can be relieved to tank by means of an
electric signal.
For a PVP pump side module in open center version the relief to tank of the LS signal means that the
pressure in the system is reduced to the sum of the tank port pressure plus the neutral flow pressure for
the pump side module.
For a PVP pump side module in closed center version the relief to tank of the LS signal means that the
pressure is reduced to the sum of the tank port pressure for the pump side module plus the stand-by
pressure of the pump.
PVPX, electrical LS unloading valve

T P

LS

157-195.11

24 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

PVG 32 technical data

The characteristics in this catalog are typical measured values. During measuring a mineral based
hydraulic oil with a viscosity of 21 mm²/s [102 SUS] at a temperature of 50 °C [122 °F] was used.

PVG 32 technical data


Maximum pressure Port P, A/B continuous* 350 bar [5075 psi]
Port P intermittent** 400 bar [5800 psi]
Port A/B intermittent** 420 bar [6090 psi]
Port T, static/dynamic 25/40 bar [365/580 psi]
Oil flow rated Port P‡§ 140/230 l/min [37/61 US gal/min]
Port A/B, with press. comp.† 100 l/min [26.4 US gal/min]
Port A/B witout press. comp. 125 l/min [33 US gal/min]
Spool travel, standard ± 7 mm [± 0.28 in]
Spool travel, float position Proportional range ± 4.8 mm [± 0.19 in]
Float position ± 8 mm [± 0.32 in]
Dead band, flow control spools Standard ± 1.5 mm [± 0.06 in]
Linear characteristic ± 0.8 mm [± 0.03 in]
Maximum. internal leakage at 100 bar [1450 psi] A/B → T without shock valve 20 cm3/min [1.85 in3/min]
and 21 mm2/s [102 SUS]
A/B → T with shock valve 25 cm3/min [2.15 in3/min]
Oil temperature (inlet temperature) Recommended temperature 30 → 60 °C [86 → 140°F]
Minimum temperature -30 °C [-22 °F]
Maximum temperature +90 °C [194 °F]
Ambient temperature -30 → 60 °C [-22 → 140 °F]
Oil viscosity Operating range 12 - 75 mm2/s [65 - 347 SUS]
Minimum viscosity 4 mm2/s [39 SUS]
Maximum viscosity 460 mm2/s [2128 SUS]
Filtration / maximum contamination according to ISO 4406 23/19/16
Oil consumption in pilot oil pressure reduction valve 0.5 l/min [0.13 US gal/min]
* With PVSI end plate. With PVS end plate max. 300 bar [4351 psi].

** Intermittent pressure at max. 250,000 cycles of full PVG life time cycles, with PVSI end plate. The maximum intermittent pressure at max. 250,000
cycles stresses the need to confirm application duty cycle before proceeding with specification. For further information contact Danfoss Product
Application Engineering.
** Intermittent pressure at max. 250,000 cycles of full PVG life time cycles, with PVSI end plate. The maximum intermittent pressure at max. 250,000
cycles stresses the need to confirm application duty cycle before proceeding with specification. For further information contact Danfoss Product
Application Engineering.
‡ In open circuit systems with short P-hoses/tubes, attention should be paid to pressure peaks at flows >100 l/min [26.4 US gal/min].

§ For a system with mid inlet PVPVM.

† For 130 l/min contact Danfoss Product Application Engineering.

Rated pressure
Product P-port max. continuous pressure
PVG 32; PVG 120/32; PVG 100/32 with PVS 300 bar [4351 psi]
PVG 32; PVG 120/32; PVG 100/32 with PVSI 350 bar [5076 psi]
PVG 32 with PVBZ 250 bar [3626 psi]
PVG 32 with HIC steel 350 bar [5076 psi]
PVG 32 with HIC aluminium 210 bar [3046 psi]

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 25


Technical Information
PVG 32 Proportional Valve Group

PVG 32 technical data

PVH, hydraulic actuation

Technical data for PVH


Control range pressure 5 – 15 bar [75 – 220 psi]

Max. pilot pressure 30 bar [435 psi]

Max. pressure on port T (the hydraulic remote control lever should be 10 bar [145 psi]
connected directly to tank.)

PVM, mechanical actuation

Operating torque for PVM


Spool displacement Operating torque N•m [lbf•in]

PVM + PVMD PVM + PVE PVM + PVH PVM + PVMR PVM+PVMF


from neutral position 2.2 ±0.2 2.2 ±0.2 2.5 ±0.2 17 22
[19.5 ±1.8] [19.5 ±1.8] [22.1 ±1.8] [3.8] [5.0]
max. spool travel 2.8 ±0.2 2.8 ±0.2 6.9 ±0.2 – –
[24.8 ±1.8] [24.8 ±1.8] [61.0 ±1.8]
into float position – – – – 60 [13.5]
away from float position – – – – 28 [6.3]
from any other position – – – 8.5 [73.3] –

No control lever position 2x6

Control lever range ±19.5°

Proportional control lever range ±13.4°

Control lever range – float position 22.3°

For further information about PVE please see the Technical Information PVE, Series 4 for PVG 32/100/120 ,
520L0553.

PVE, electrical actuation

Technical data for PVEO and PVEM


Supply voltage UDC rated 12 VDC 24 VDC

range 11 V to 15 V 22 V to 30 V

max. ripple 5%

Current consumption at rated voltage 0.65 A @ 12 V 0.33 A @ 24 V

Signal voltage (PVEM) neutral 0.5 x UDC

A-port ↔ B-port 0.25 • UDC to 0.75 • UDC

Signal current at rated voltage (PVEM) 0.25 mA 0.50 mA

Input impedance in relation to 0.5 • UDC 12 KΩ

Power consumption 8W

26 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

PVG 32 technical data

Technical data for PVEA, PVEH and PVES


Supply voltage UDC rated 11 V to 32 V

range 11 V to 32 V

max. ripple 5%

Current consumption at rated voltage PVEH/PVES (PVEA) 0.57 (33) A @ 12 V 0.3 (17) A @ 24 V

Signal voltage neutral 0.5 x UDC

A-port ↔ B-port 0.25 • UDC to 0.75 • UDC

Signal current at rated voltage 0.25 mA to 0.70 mA

Input impedance in relation to 0.5 • UDC 12 KΩ

Input capacitor 100 ηF

Power consumption PVEH/PVES (PVEA) 7 (3.5) W

(PVEH/PVES) Max. load 100 mA 60 mA


Active Reaction time at fault 500 ms (PVEA: 750 ms)

Passive Reaction time at fault 250 ms (PVEA: 750 ms)

Reaction time for PVEO and PVEM


Supply voltage Function PVEO, PVEO-R, PVEM, Prop.
On/Off On/Off med.
Disconnected by means of Reaction time from neutral max. 0.235 s 0.410 s 0.700 s
neutral switch position to max. spool travel
rated 0.180 s 0.350 s 0.450 s
min. 0.120 s 0.250 s 0.230 s
Disconnected by means of Reaction time from max. max. 0.175 s 0.330 s 0.175 s
neutral switch spool travel to neutral
rated 0.090 s 0.270 s 0.090 s
position
min. 0.065 s 0.250 s 0.065 s
Constant voltage Reaction time from neutral max. - - 0.700 s
position to max. spool
rated - - 0.450 s
position
min. - - 0.230 s
Constant voltage Reaction time from max. max. - - 0.700 s
spool travel to neutral
rated - - 0.450 s
position
min. - - 0.230 s
Hysteresis* rated - - 20%
* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz for one cycle.
(one cycle = neutral → full A → full B → neutral)

Reaction time for PVEA, PVEH and PVES


Supply voltage Function PVEA PVEH PVES
Prop. fine Prop. high Prop. super
s s s
Disconnected by means Reaction time from neutral max. 0.50 0.23 0.23
of neutral switch position to max. spool travel
rated 0.32 0.15 0.15
min. 0.25 0.12 0.12

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 27


Technical Information
PVG 32 Proportional Valve Group

PVG 32 technical data

Reaction time for PVEA, PVEH and PVES (continued)


Supply voltage Function PVEA PVEH PVES
Prop. fine Prop. high Prop. super
s s s
Disconnected by means Reaction time from max. spool max. 0.55 0.175 0.175
of neutral switch travel to neutral position
rated 0.40 0.09 0.09
min. 0.30 0.065 0.065
Constant voltage Reaction time from neutral max. 0.50 0.20 0.20
position to max. spool travel
rated 0.32 0.12 0.12
min. 0.25 0.05 0.05
Constant voltage Reaction time from max. spool max. 0.25 0.10 0.10
travel to neutral position
rated 0.20 0.09 0.09
min. 0.15 0.065 0.065
Hysteresis * rated 2% 4% ∼ 0%

The following technical data are from typical test results. For the hydraulic system a mineral based
hydraulic oil with a viscosity of 21 mm²/s [102 SUS] and a temperature of 50 °C [122 °F] were used.

Typical hysteresis characteristics for control signal vs spool travel of different PVE types*
+8

+6
PVEM PVEA PVEH PVES
+4

+2

0
20% 2% 4% ~0%
-2

-4

-6

-8
157-504.10

* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz. (one cycle = neutral
→ full A → full B → neutral)
The following technical data are from typical test results. For the hydraulic system a minetal based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] and a temperature of 50 °C [122 °F] were used.

Pilot oil consumption for PVEA, PVEH, PVES, PVEO and PVEM
Function PVEA PVEH PVES PVEO PVEM
Prop. fine Prop. high Prop. super ON/OFF Prop. medium
Neutral without 0 0 0.3 l/min 0 0
supply voltage [0.079 US gal/min]
Locked with supply 0.4 l/min 0.1 l/min 0.3 l/min 0.1 l/min 0.1 l/min
voltage [0.106 US gal/min] [0.026 US gal/min] [0.026 US gal/min] [0.026 US gal/min] [0.026 US gal/min]
Continuous actuations 1.0 l/min 0.7 l/min 0.8 l/min 0.7 l/min 0.5 l/min
with supply voltage [0.26 US gal/min] [0.185 US gal/min] [0.211 US gal/min] [0.185 US gal/min] [0.132 US gal/min]
One actuation 2 cm³ [0.12 in³]
(neutral → max)
with supply voltage

28 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

PVG 32 technical data

Fluids parameters
Oil viscosity* recommended range 12 - 75 mm²/s [65 - 347 SUS]
minimum 4 mm²/s [39 SUS]
maximum 460 mm²/s [2128 SUS]
Oil temperature recommended range 30 - 60˚C [86 -140˚F]
minimum -30˚C [-22˚F]
maximum 90˚C [194˚F]
Ambient temperature recommended range -30° → 60°C [-22° → 140°F]
Filtering in the hydraulic system Max. allowed degree of contamination: 23/19/16
(ISO 4406, 1999 version)
* Max. start up viscosity 2500 mm²/s.

PVPX, electrical LS unloading valve

PVPX technical data


Max. operating pressure 350 bar [5075 psi]

Enclosure to IEC 529 IP65

Max. pressure drop at an oil flow of 0.1 l/min [2.6 US gal/min] 2 bar [30 psi]

Oil temperature Recommended temperature 30 °C to 60 °C [86 °F to 140 °F]


(Inlet)
Min. temperature -30 °C [-22 °F]

Max. temperature 90 °C [194 °F]

Max. coil surface temperature 155 °C [311 °F]

Ambient temperature -30 °C to 60 °C [-22 °F to 140 °F]

Oil viscosity Operating range 12 to 75 mm2/s [65 to 347 SUS]

Min. viscosity 4 mm2/s [39 SUS]

Max. viscosity 460 mm2/s [2128 SUS]

Response time for LS pressure relief 300 ms

Rated voltage 12 V 24 V

Max. premissible deviation from rated supply voltage ± 10%

Current consumption at rated at 22 °C [72 °F] coil temperature 1.55 A 0.78 A


voltage
at 110 °C [230 °F] coil temperature 1A 0.5 A

Power consumption at 22 °C [72 °F] coil temperature 19 W

at 110 °C [230 °F] coil temperature 12 W

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 29


Technical Information
PVG 32 Proportional Valve Group

Electrical actuation

Electrical control of PVG


Valve actuation with electrical actuators has been supported by Danfoss for a long time. The actuation
can be controlled directly by joystick, by a PLUS+1® controller or by a broad range of third part
controllers. The actuator controls the spool by building up pilot oil pressure on the end of the spool. For
the PVE a pilot oil pressure between 10 and 15 bar is used. For the PVHC a pilot oil pressure between 20
and 25 bar is used.
PVG with PVE

Valve section with naming - standard mounted - seen from PVP


P -> A

Pilot oil supply Oil


B port A port
PVE PVM
PVB

Electronics
Neutral spring

NC Solenoid valves
PVBS
LVDT
NO solenoid valves
V310072.B

A detailed description of the variants is presented in:


PVE-Series 4 for PVG 32, PVG 100 and PVG 120 Technical Information, 520L0553, covers all analogue PVE –
PVEO, PVEH, PVES, PVEA, PVEM, PVEU, PVEP and the current controlled PVHC.
Electrohydraulic Actuator – PVED-CC Series 4 Technical Information, 520L0665, covers the ISOBUS/SAE
J1939 CAN controlled PVED-CC.
Electrohydraulic Actuator – PVED-CX Series 4 Technical Information, 11070179, covers the IEC61508 SIL2
certified CANopen controlled PVED-CX.

30 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Electrical actuation

PVE characteristic - control by voltage

PVEP
control range
PVEU
2.5V 5V 7.5V fixed

Closed loop control


The PVE variants PVEA/H/M/S/U/P and the PVED-CC/-CX has a closed loop control supported by a spool
position sensor that ensures integrity towards flow forces and oil viscosity.
Hysteresus for PVE variants*
+8

+6
PVEM PVEA PVEH PVES
+4

+2

0
20% 2% 4% ~0%
-2

-4

-6

-8
157-504.10

* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz. (one cycle = neutral
→ full A → full B → neutral)
The standard PVE’s are proportional activated actuator except PVEO which is on/off. The PVE’s have fault-
monitoring.
• PVEU is available with PVEH and PVES hysteresis
• PVEP, PVED-CC and PVED-CX are available with PVES hysteresis

The values are typical test data for exact ranges, see PVE Technical Information, 520L0553.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 31


Technical Information
PVG 32 Proportional Valve Group

Electrical actuation

Fault monitoring overview


Type Fault Delay before error Error mode Error output Fault output LED light Memory†
monitoring out status on PVE
PVEO No fault monitoring
PVEM
PVEA Active 500 ms No fault Low <2V Green –
PVEH (PVEA: 750 ms)
Input signal faults High ~UDC Flashing red Yes
PVEP
PVES Transducer (LVDT) Constant red
PVEU Close loop fault
Passive 250 ms No fault Low <2V Green –
(PVEA: 750 ms)
Input signal faults High ~UDC Flashing red No
Transducer (LVDT) Constant red
Close loop fault
PVE Active 500 ms Float not active High ~UDC Constant red Yes
Float
750 ms Float still active
six pin
Measured between fault output pin and ground.
† Reset needed

PVEO
The PVEO is an on/off activated actuator. The PVEO has not fault-monitoring.

Variants: Power supply:


• PVEO-R with a ramp delayed actuation • 12 V
• PVEO-DI with direction indication feedback • 24 V
• Anodized aluminum block Connectors:
• ATEX certified • AMP
• DIN/Hirshmann
• Deutsch®

AMP version DIN/Hirschmann version Deutsch® version


PVEO/PVEO-R

3
U DC
U DC
2

157-502.11

PVEM
The PVEM is a proportional activated actuator. The PVEM has not fault-monitoring.
Variants:
• PVEM -R with a ramp delayed actuation
• PVEM for float in B-direction and max. flow B at 4.8 mm

Power supply: 12 / 24 V
Connectors:DIN/Hirshmann

32 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Electrical actuation

PVEA, PVEH, PVES, PVEU

Variants: Power supply: 11→ 32 V


• -F for float in B-direction Connectors:
max. flow B at 4.8 mm • AMP
• -F for float in A-direction • DIN/Hirshmann
max. flow A at 5.5 mm • Deutsch®
• PVES-SP with spool position feedback
• Anodized aluminum block
• ATEX certified

AMP version DIN/Hirschmann version Deutsch® version


PVEA/PVEH/PVES

LED
US LED
Pin no.
U DC 1
2
3
4
Error
Grey connector

157-500.10

PVEA, PVEH, PVES, PVEU PVEH, PVEM, PVES, PVEA, PVEH, PVES, PVEU
and PVEH float A PVEH float B and PVEM float B and PVEH float B

PVEP

The PVEP is controlled with separate PWM control signals


for A and B direction. Deutsch® version
The PVEP has hysteresis and fault monitoring like the PVES-SP
PVES.
Power supply: 11→ 32 V
LED
Connector: Deutsch®
Not Spool position
connected
3 4
Error 2 5
1 6
Us UDC

PVED-CC and PVED-CX


The CAN controlled PVE embedded microcontrollers support the same high spool controllability as the
PVES and additional has high quality feedbacks, safety monitoring and detailed diagnostics.
PVED has digital communication, that allows a wide range of feedback, setpoint and highly costumized
settings. CAN bus serial communication makes wiring much easier. Only one cable per PVG group.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 33


Technical Information
PVG 32 Proportional Valve Group

Electrical actuation

Power supply: 11 → 32 V
Connectors: PVE with Deutsch® connector incl. female connector
• Deutsch® (PVED-CC)
• AMP (PVED-CC and
PVED-CX)

For more information on PVED please see the PVED-CC, Series 4 Technical Information, 520L0665.

PVHC
For PVG controlled by PVHC, hysteresis is influenced by lever (PVM). The PVHC control is done by dual
Pulse Width Modulated (PVM) high current supply 100-400 Hz PWM control signals.
The PVHC does not have neither fault monitoring nor internal closed loop control of the spool.

Power supply:
• 12 V PVHC with AMP version PVHC with Deutsch® version
• 24 V 5.7
[0.224]
5.7
[0.224]
5.7
[0.224]
5.7
[0.224]
44.4 [1.748]
Connectors: 44.4 [1.748]

• Deutsch®
33.0 [1.299]
33.0 [1.299]

• AMP 26.75
[1.053]
26.75
[1.053]

74.0 92.25
[2.913] [3.631]
74.0 92.25
[2.913] [3.631]

16.5 5.75
[0.650] [0.226]

P301 124
16.5 5.75
[0.650] [0.226]
P301 123

34 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Electrical actuation

PVHC characteristic - Spool stroke vs current


Spool stroke, mm

5
Ideal curve
4

3
Hysteresis

Current in mA
0

800
200
800

400
600

400
200

600
1200

1000

1400
1200
1000
1400

1600
1600

@ 12V
600

@ 24V
400

200
300
500

400
100
100

200

300

700
600
700

500
800

800
500/1000 mA 280/560 mA 280/560 mA 500/1000 mA V310 000.A

PVHC current response and hysteresis @ 25 bar Pp, 21 ctS, 25 °C. The ideal curve is determined by the
main spool neutral spring. The PVHC has high hysteresis. The hysteresis is affected by viscosity, friction,
flow forces, dither frequency and modulation frequency. The spool position will shift when conditions are
changed e.g. temperature change.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 35


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

General
The characteristics in this catalog are typical measured values. During measuring a mineral based
hydraulic oil with a viscosity of 21 mm2/s [102 SUS] at a temperature of 50°C [122°F] was used.

PVP, pump side module

Pressure relief valve characteristic in PVP


The pressure relief valve is set at an oil flow of 15 l/min [4.0 US gal/min].
Setting range:
• 30 to 350 bar [435 to 5075 psi] with PVSI end plate
• 30 to 300 bar [435 to 4351 psi] with PVS end plate

Pressure relief valve characteristic Neutral by-pass pressure drop characteristic (open
center)

PVB, basic modules oil flow characteristics


The oil flow for the individual spool depends on:
• type of basic module (with/without compensation)
• type of pump (fixed or variable displacement).

36 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

Linear oil flow depending on spool type

US = Signal voltage; UDC = Supply voltage; 1 = First PVB after PVP; 8 = Eighth PVB after

Pressure-compensated PVB, open center PVP


The oil flow is dependent on the supplied pump oil flow.
The characteristics are plotted for a pump oil flow, QP, corresponding to the rated maximum spool oil
flow, QN. Increasing the pump oil flow to 1,4 × QN will give the same oil flow on the eighth as on the first
basic module.
The letters AA, A, B, etc. denote spool types. The characteristic below is shown for spool travel in both
directions. All other characteristics are shown for spool travel in one direction only.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 37


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

Progressive oil flow characteristic depending on spool type

PVM

PVM

PVE

PWM for PVEP/T


control range
157-61.im

US = Signal voltage; UDC = Supply voltage; 1 = First PVB after PVP; 8 = Eighth PVB after

PVB without pressure compensation, open center PVP


The spool flow is dependent on the supplied oil flow, QP.
The characteristics apply to supply oil flow of 130 l/min [34.3 US gal/min] with the actuation of one basic
module and the supply flow level.
If several basic modules are activated at the same time, the characteristic depends on the load pressure
of the actuated basic modules.
Oil flow as a function of spool travel characteristic

Oil flow QA/B as a function of supplied pump oil flow (QP)

38 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

The pressure drop of any oil flowing back to tank (QP - QA/B) is read on the curve for neutral flow pressure
in PVP.
Characteristic for fully displaced flow control spools

PVB without pressure compensation, closed center PVP

Set pressure difference between pump pressure and LS signal = 10 bar [145 psi].

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 39


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

Set pressure difference between pump pressure and LS signal = 20 bar [290 psi].

The oil flow is dependent on the pressure difference between the pump pressure and the LS signal.
Normally the pressure difference is set at the LS pump regulator. Also take into consideration pressure
drop from the pump to the PVG valve group. e.g. long pipeline.

Oil flow characteristics for PVB at

@ pressure drop at max. main spool travel @ pressure drop for open spool in neutral position

Load-independent, pressure-compensated LS pressure limiting, pressure-compensated PVB

40 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

PVLP, shock and PVLA, suction valves


PVLP is set at an oil flow of 10 l/min [2.6 US gal/min]. The shock valve PVLP is designed to absorb shock
effects. Consequently, it should not be used as a pressure relief valve.
If the working function requires the use of a pressure relief valve, a PVB basic module with built-in LSA/B
pressure limiting valve should be used.

PVLP, shock valve characteristic PVLA, suction valve characteristic

Pressure build-up for pressure controlled spools


Max. oil flow can be reduced by about 50%
without limitation of maximum pressure by
limiting the main spool travel from 7 mm
[0.28 in] to 5.5 mm [0.22 in].

Pressure control spool flow characteristics

Size A: Size B:

Example 1

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 41


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

Size C: Size D:

Example 2

Size E:

Examples of how to use the characteristics for pressure control spools

Example 1: Determining the oil flow Example 2: Determining the spool size
Given: Given:
• Spool type B • Max. oil flow, QA/B: 90 l/min [23.8 US gal/min]
• Pressure setting PP: 160 bar [2320 psi] • Pressure setting PP: 150 bar [2175 psi]
• Load pressure, LSA/B: 100 bar [1450 psi] • Load pressure, PLSA: 125 bar [1810 psi]
Result: Result: D spool
Oil flow = 75 l/min [19.8 US gal/min] (see Pressure CS flow characteristics, size D)

Normally a smaller spool can be chosen with pressure control. It is our experience that the spool can be
one size smaller than with normal flow control.

42 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

Characteristics for float position main spools


Characteristic of oil flow, spool travel and voltage

• 4.8 mm [0.19 in] spool displacement in direction A gives maximum oil flow to port A
• 4.8 mm [0.19 in] spool displacement in direction B gives maximum oil flow to port B
• 8 mm [0.32 in] spool displacement in direction B gives completely open float position A/B → T.

The spools have 4.8 mm spool travel in direction A and 8 mm travel in direction B:

For more information regarding electrical actuation of float spools please see PVE series 4 Technical
Information, 520L0553.

Pressure drop A/B → T at maximum spool travel within the proportional range (4.8 mm) [0.19 in]

Spools D and E have the same opening area for forward flow and return flow.
Spool E can give 100 l/min [26.4 US gal/min] pressure compensated oil flow due to a higher pressure
drop across spool E. This occurs during spool actuation only.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 43


Technical Information
PVG 32 Proportional Valve Group

Technical characteristics

Pressure drop A/B → T in float position

44 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Hydraulic systems

Manually actuated PVG 32 – fixed displ. pump


Example schematic of manually actuated PVG 32 – fixed displacement pump

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 45


Technical Information
PVG 32 Proportional Valve Group

Hydraulic systems

Electrically actuated PVG 32 – variable displ. pump


Example schematic of electrically actuated PVG 32 – variable displacement pump (electrical actuator, shock valves, relief valve)

46 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Other operating conditions

Oil
The main duty of the oil in a hydraulic system is to transfer energy. It must also lubricate the moving parts
in hydraulic components, protect them against corrosion, and transport dirt particles and heat out of the
system. It is therefore important to choose the correct oil with the correct additives. This gives normal
operation and long working life.

Mineral oil
For systems with PVG 32 valves Danfoss recommends the use of mineral-based hydraulic oil containing
additives: Type HLP (DIN 51524) or HM (ISO 6743/4).

Non-flammable fluids
Phosphate-esters (HFDR fluids) can be used without special precautions. However, dynamic seals must be
replaced with FPM (Viton) seals. Please contact the Danfoss Sales Organization if the PVG 32 valve is to be
used with phosphate-esters.
The following fluids should only be used according to agreement with the Danfoss Sales Organization
for:
• Water-glycol mixtures (HFC fluids)
• Water-oil emulsions (HFB fluids)
• Oil-water emulsions (HFAE fluids)

Particle content, degree of contamination

Biodegradable oils
PVG 32 valves can be used in systems with rapeseed oil. The use of rapeseed oil is conditioned by:
• complying with the demands on viscosity, water content, temperature and filtering etc. (see chapters
below and technical data).
• adapting the operating conditions to the directions of the oil supplier.
Before using other biodegradable fluids, please consult the Danfoss organization. Oil filtration must
prevent particle content from exceeding an acceptable level, i.e., an acceptable degree of contamination.
Maximum contamination for PVG 32 is 23/19/16 (see ISO 4406. Calibration in accordance with the ACFTD
method). In our experience a degree of contamination of 23/19/16 can be maintained by using a filter
fineness as described in the next section.
For more information, please see the Danfoss literature:
• Design Guidelines for Hydraulic Fluid Cleanliness Technical Information, 520L0467
• Hydraulic Fluids and Lubricants Technical Information, 521L0463
• Experience with Biodegradable Hydraulic Fluids Technical Information, 521L0465.

Filtration
Effective filtration is the most important precondition in ensuring that a hydraulic system performs
reliably and has a long working life. Filter manufacturers issue instructions and recommendations. It is
advisable to follow these.

System filters
Where demands on safety and reliability are very high a pressure filter with bypass and indicator is
recommended. Experience shows that a 10 µm nominal filter (or finer) or a 20 µm absolute filter (or finer)
is suitable. It is our experience that a return filter is adequate in a purely mechanically operated valve
system. The fineness of a pressure filter must be selected as described by the filter manufacturer so that a
particle level of 23/19/16 is not exceeded. The filter must be fitted with pressure gauge or dirt indicator to
make it possible to check the condition of the filter. In systems with differential cylinders or accumulators

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 47


Technical Information
PVG 32 Proportional Valve Group

Other operating conditions

the return filter must be sized to suit the max. return oil flow. Pressure filters must be fitted to suit max.
pump oil flow.

Internal filters
The filters built into PVG 32 are not intended to filter the system but to protect important components
against large particles. Such particles can appear in the system as a result of pump damage, hose fracture,
use of quick-couplings, filter damage, starting up, contamination, etc. The filter in the electrical actuator
PVE protecting the solenoid valves has a mesh of 150 µm. Bursting pressure drop for internal filters is 25
bar [360 psi].

48 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Dimensions

PVG 32 Dimensions

Legend:
F: Shock and suction valve, PVLP M: LX connection: PVS; G 1 ∕8, 10 mm [3 ∕8–24; 0.39 in] deep
G: Pressure gauge connection: G¼, 12 mm [½ –20, 0.47 and
in] deep PVSI; G¼, 12 mm [½ –20; 0.47 in] deep
H: Plug for external pilot oil supply, PVPC: G½, 12 mm [½ N: LS pressure limiting valve
–20, 0.47 in] deep O: Tank connection; G¾, 16 mm [1 1 ∕16–12; 0.75 in] deep
I: Electrical LS unloading valve, PVPX P: Pressure relief valve
J: LS connection: G¼, 12 mm [½–20; 0.47 in or 9 ∕16–18, 0.5 Q: Pump connection; G½, 14 mm [7 ∕8–14; 0.65 in] deep or
in] deep G¾, 16 mm [1 1 ∕16–12; 0.75 in] deep
K: Fixing holes: M8 × min. 10 [5 ∕16–18; 0.39 in] deep R: LSA and LSB connections; G¼, 12 mm deep [9 ∕16–18, 0.5
L: Port A and B: G½, 14 mm [7 ∕8–14; 0.65 in] deep in] deep
S: Pp, pilot pressure connection G

PVB 1 2 3 4 5 6 7 8 9 10 11 12
L1 mm 82 130 178 226 274 322 370 418 466 514 562 610
[in] [3.23] [5.12] [7.01] [8.90] [10.79] [12.68] [14.57] [16.46] [18.35] [20.24] [562] [610]
L2 mm 140 189 238 287 336 385 434 483 527 576 622 670
in] [5.51] [7.44] [9.37] [11.30] [13.23] [15.16] [17.09] [19.02] [20.95] [22.87] [622] [670]

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 49


Technical Information
PVG 32 Proportional Valve Group

Dimensions

F A-A

0]
]
.732

6.5
65[
32[1.26]

44 [1

~1
P P
V
85[3.35]
85[3.35]

P V
M
58.5[2.303]

V M
R H D
45[1.77]

/
F

49.5[1.949] 33[1.30] 110[4.33] 60[2.36]


7[0.28]
7[0.28]

6.5[0.256]

max.200.5[7.894]

17[0.67]

85.5[3.366]
13[0.51]

B-B
129[5.08]
95[3.74]

PVEO

107[4.21] 110[4.33] 60[2.36]


7[0.28]

max.290.50[11.437]

89.5[3.524]

C-C
139[5.472]
117[4.61]

PVEM/PVEH/
PVES

107[4.21] 110[4.33] 60[2.36]


7[0.28]

max.290.50[11.437]

V310141.A

F : G ¼, 12 mm deep [½ in - 20, 0.47 in deep]

PVM, control lever positions

Base with an angle of 37.5° Base with an angle of 22.5°

19.5
˚
19.5˚

19
19

.5˚
.5˚

37.5 67
˚ .5˚
97
.5˚

22.5˚
127

52
.5˚ 82
.5˚

.5
˚
157.5˚

11
2.5
142.5
˚
187.5˚

˚
172.5˚

V310018.A
V310014.A

50 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Dimensions

The angle of the handle is determined by which side of the handle that is mount towards the base. If a
22.5° angle is needed the "dot" on the handle is not visible. If 37.5° is needed the dot should be visible.

Surface treatment
The PVG valve has as standard, an untreated surface. In certain applications, depend on different factors,
such as: salty environment, large temperature changes, high humidity, rust can develope on the surface.
This will not affect the performance of the PVG valve group. To prevent/reduce rust development,
Danfoss recommend the PVG valve group to be painted. Rust on the surface is not seen as a valid
complaint issue, neither on painted or unpainted PVG valve groups.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 51


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVP, pump side modules

Symbol Description Code number


Open center pump side module for pumps P=G½ 157B5000
with fixed displacement. T=G¾
For purely mechanically actuated valve
P = 7/8–14 157B5200
groups
T = 1 1/16–12
P, T = G ¾ 157B5100
P, T = 1 1/16–12 157B5300

Closed center pump side module for pumps P=G½ 157B5001


with vaiable displacement. T=G¾
P = 7/8–14 157B5201
T = 1 1/16–12
For purely mechanically actuated valve P, T = G ¾ 157B5101
groups.
P, T = 1 1/16–12 157B5301
Open center pump side module for pumps P=G½ 157B5010
with fixed displacement. T=G¾
With pilot oil supply for electrically actuated
P = 7/8–14 157B5210
valves.
T = 1 1/16–12
P, T = G ¾ 157B5110
P, T = 1 1/16–12 157B5310

Closed center pump side module for pumps P=G½ 157B5011


with variable displacement. T=G¾
With pilot oil supply for electrically actuated
P = 7/8–14 157B5211
valves.
T = 1 1/16–12
P, T = G ¾ 157B5111
P, T = 1 1/16–12 157B5311
Open center pump side module for pumps P=G½ 157B5012
with fixed displacement. T=G¾
With pilot oil supply for electrically actuated
P = 7/8–14 157B5212
valves
T = 1 1/16–12
Connection for electrical LS unloading valve,
PVPX (not incl.) P, T = G ¾ 157B5112
P, T = 1 1/16–12 157B5312

Closed center pump side module for pumps P=G½ 157B5013


with variable displacement T=G¾
With pilot oil supply
P = 7/8–14 157B5213
Connection for electrical LS unloading valve,
T = 1 1/16–12
PVPX (not incl.)
P, T = G ¾ 157B5113
P, T = 1 1/16–12 157B5313

Connections:
P = G ½ in; 14 mm deep or G ¾ in; 16 mm deep / LS, M = G ¼ in; 12 mm deep / T = G ¾ in; 16 mm deep.
P = 7/8–14; 0.65 in deep or 1 1/16–12; 0.75 in deep / LS, M = ½–20; 0.47 in deep / T = 1 1/16–12; 0.75 in
deep.

52 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVP, pump side modules


Symbol Description Code number
Open center pump side module for pumps with fixed P, T = G ¾ 157B5102
displacement.
For mechanical actuated valves.
Connection for LS unloading valve, PVPX (not incl)

Closed center pump side module for pumps with P, T = G ¾ 157B5103


vaiable displacement.
For mechanical actuated valves.
Connection for LS unloading valve, PVPX (not incl)

Open center pump side module for pumps with fixed P, T = G ¾ 157B5180
displacement.
P, T = 1 1/16–12 157B5380
With pilot oil supply for electrical actuation and
LS connection =
connection for pilot oil pressure
9/16–18
Incl. check valve

Closed center pump side module for pumps with P, T = G ¾ 157B5181


variable displacement.
P, T = 1 1/16–12 157B5381
With pilot oil supply for electrical actuation and
LS connection =
connection for pilot oil pressure
9/16–18
Incl. check valve

Open center pump side module for pumps with fixed P, T = G ¾ 157B5190
displacement.
P, T = 1 1/16–12 157B5390
With pilot oil supply for hydraulic actuation and
LS connection =
connection for pilot oil pressure
9/16–18

Closed center pump side module pumps with variable P, T = G ¾ 157B5191


displacement
P, T = 1 1/16–12 157B5391
With pilot oil supply for hydraulic actuation and
LS connection =
connection for pilot oil pressure
9/16–18

Connections:
P, T = G ¾ in; 16 mm deep / LS, M = G ¼ in; 12 mm deep
P, T = 1 1/16–12; 0.75 in deep / LS, M = ½–20; 0.47 in deep.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 53


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVB, basic modules

PVB, basic modules – without adjustable LSA/B pressure limiting valves


Symbol Description Code number

No facilities for Facilities for shock


shock valves A/B valves A/B
Without load drop check valve and G½ 157B6000 157B6030
pressure compensator. 14 mm deep
Can be used where load holding
7/8–14 157B6400 157B6430
valves prevent oil from flowing
0.65 in deep
back through channel P.

Load drop check valve. G½ 157B6100 157B6130


14 mm deep
7/8–14 157B6500 157B6530
0.65 in deep

Load drop check valve. G½ — 157B6136


LSA/B shuttle valve. 14 mm deep
To be used with float position
7/8–14 — 157B6536
spools.
0.65 in deep

Non-damped compensator valve G½ 157B6200 157B6230


14 mm deep
7/8–14 157B6600 157B6630
0.65 in deep

Without compensator valve G½ — 11071832


LSA/B shuttle valve 14 mm deep
7/8–14 — —
0.65 in deep

V310411.A

54 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVB, basic modules – without adjustable LSA/B pressure limiting valves (continued)
Symbol Description Code number

No facilities for Facilities for shock


shock valves A/B valves A/B
With damped compensator valve G½ 157B6206 157B6236
14 mm deep
7/8–14 11036629 11036630
0.65 in deep

PVB, basic modules – with adjustable LSA/B pressure limiting valves


Symbol Description Code number

No facilities for Facilities for


shock valves A/B shock valves A/B
With non-damped G½ 157B6203 157B6233
compensator valve 14 mm
Adjustable LSA/B pressure deep
limiting valves
7/8–14 157B6603 157B6633
External LS connection port
0.65 in deep
A/B.
Also used for float position
spools

Damped compensator valve G½ 157B6208 157B6238


Adjustable LSA/B pressure 14 mm deep
limiting valves
7/8–14 - 11036631
External LS connection port
0.65 in deep
A/B

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 55


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVLA, suction valve (fitted in PVB)

PVLA, suction valve


Symbol Description Code number
Suction valve for port A and/or B. 157B2001

Plug for connecting the nonactive port to tank, when using a 157B2002
single acting spool.

PVLP, shock and suction valve (fitted in PVB)

PVLP, shock/ and anti-cavitation valves


Code no. 2032 2050 2063 2080 2100 2125 2140 2150 2160 2175 2190
157B....
Settings bar 32 50 63 80 100 125 140 150 160 175 190
[psi] [460] [725] [914] [1160] [1450] [1813] [2031] [2175] [2320] [2538] [2755]

Code no. 2210 2230 2240 2250 2265 2280 2300 2320 2350 2380 2400
157B....
Settings bar 210 230 240 250 265 280 300 320 350 380 400
[psi] [3045] [3335] [3480] [3625] [3845] [4061] [4351] [4641] [5075] [5511] [5801]

PVLP, shock and suction valve


Symbol Description

Shock and suction valve for port A and/or B.


(Not adjustable).
Lifetime 200.000 actuations.

56 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVM, mechanical actuation

PVM, mechanical actuation


Symbol Description Code number
with stop screws w/o stop screws
PVM, Standard, spring centered 157B3171 157B3191
Individual oil flow adjustment to ports A and B
Without actuation lever and base. 157B3173 157B3193
Shaft for mounting of actuation lever
PVM, as standard, witout actuation lever. 157B3174 157B3194
With base for mounting of actuation lever
PVM, Standard, spring. Individual oil flow 157B3184 -
adjustment to ports A and B. (Anodized)

PVMD, cover for mechanical actuation


Symbol Description Material Code No. Anodized
— PVMD, Cover for purely mechanically operated valve aluminium 157B0001 no
aluminium 157B0009 yes
cast iron 157B0021 no

PVMR, friction detent


Symbol Description Material Code number Anodized
PVMR, Friction detent aluminium 157B0004 no
aluminium 157B0012 yes
cast iron 157B0024 -

PVMF, mechanical float position


Symbol Description Material Code number Anodized
PVMF, aluminium 157B0005 no
Mechanical float position lock

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 57


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVH, hydraulic actuation

PVH, hydraulic actuation


Symbol Description Material Code number Anodized
PVH, Cover for Hydraulic actuation aluminium 157B0007 no
PVH 9/16-18 UNF
aluminium 157B0010 yes
cast iron 157B0014 no
PVH, Cover for Hydraulic actuation aluminium 157B0008 no
PVH G1/4
aluminium 157B0011 yes
cast iron 157B0016 no

PVS, end plate

PVS, end plate


Symbol Description Mounting Code number
threads
PVS, without active elements. BSP 157B2000
No connections
SAE 157B2020
V310062.A

PVS, without active elements. G 1/8 10 mm deep BSP 157B2011


Max. intermittend LX pressure
3/8 in - 24; 0,39 in deep SAE 157B2021
250 bar [3625 psi]
LX V310063.A

PVSI, without active elements BSP 157B2014


Without connections.
SAE 157B2004
V310062.A

PVSI, without active elements G 1/4 10 mm deep BSP 157B2015


LX connections.
1/2 in - 20; 0,47 in deep SAE 157B2005
Max. intermittend LX pressure:
LX V310063.A 350 bar [5075 psi]

For mounting threats please see the chapter Dimensions.

PVAS, assembly kit

PVAS, assembly kit


Code no, 0 1 2 3 4 5 6 7 8 9 10 11 12
157B...
PVB’s 8000 8001 8002 8003 8004 8005 8006 8007 8008 8009 8010 8061 8062
PVB + PVPVM - 8021 8022 8023 8024 8025 8026 8027 8028 8029 8030 8081 8082
Weight kg [lb] 0.1[0.2] 0.15 0.25 0.30 0.40 0.45 0.50 0.60 0.65 0.70 0.80 0.85 0.9 [2.0]
[0.3] [0.6] [0.7] [0.9] [1.0] [1.1] [1.3] [1.4] [1.6] [1.7] [1.8]

58 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Modules symbols, description and code numbers

PVPX, electrical LS unloaded valve

PVPX, electrical LS unloaded valve


Symbol Description Code number
PVPX, Normally open: 12 V 157B4236
LS pressure relieved with no signal to PVPX 24 V 157B4238

PVPX, Normally closed: 12 V 157B4246


LS pressure relieved with signal to PVPX 24 V 157B4248

PVPX, Normally open with manual override: 12 V 157B4256


LS pressure relieved with no signal to PVPX 24 V 157B4258
Manual override DE-selects LS-pump

- Plug 157B5601

PVPC, plug for external pilot oil supply

PVPC, plug for external pilot oil supply


Symbol Description Code number
PVP, G 1/2, 157B5400
Plug without check valve for open 12 mm deep
or closed center
1/2 in - 20; -
0.47 in deep

PVP, G 1/2, 157B5600


Plug with check valve for 12 mm deep
open center
1/2 in - 20; 157B5700
0.47 in deep

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 59


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

Standard FC spools

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min] ISO symbol Symbol Press. compensated flow l/min [US gal/min]
F E D C B A AA AA A B C D E F
130 100 65 40 25 10 5 [1.3] 5 [1.3] 10 25 40 65 100 130
[34.3] [26.4] [17.2] [10.6] [6.6] [2.6] [2.6] [6.6] [10.6] [17.2] [26. [34.3]
4]
7026 7024 7023 7022 7021 7020 7025 7005 7000 7001 7002 7003 700 7006
4

4-way, 3-position
Closed neutral position
7126 7124 7123 7122 7121 7120 7125 7105 7100 7101 7102 7103 710 7106
4

4-way, 3-position
Throttled, open neutral position
- - - - - - - - 7200 7201 7202 7203 720 -
4

3-way, 3-position
Closed neutral position, P → A
- - - - - - - - - 7301 7302 7303 730 -
4

3-way, 3-position
Closed neutral position, P → B
- 7424 7423 7422 7421 - - - - 7401 7402 7403 740 7406
4

4-way, 3-position
Throttled, A → T in neutral position

60 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
- 7524 7523 7522 7521 - - - - 7501 7502 7503 750 -
4

4-way, 3-position
Throttled, B → T in neutral position
- 7624 7623 7622 7621 7620 - - - - - - - -

157-139.10 157-140.10

4-way, 4-position
Closed neutral position
Float P → B → F

Standard FC spools, hydraulic actuation

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min] ISO symbol Symbol Press. compensated flow: l/min [US gal/min]
E D C B A AA AA A B C D E
100 65 40 25 10 5 5 10 25 40 65 100
[26.4] [17.2] [10.6] [6.6] [2.6] [1.3] [1.3] [2.6] [6.6] [10.6] [17.2] [26.4]
9024 9023 9022 9021 9020 9025 9005 9000 9001 9002 9003 9004

4-way, 3-position
closed neutral position
9124 9123 9122 9121 9120 9125 9105 9100 9101 9102 9103 9104

4-way, 3-position
Throttled open neutral position

FC spools for mechanical float position, PVMF

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min] ISO symbol Symbol Press. compensated flow l/min [US gal/min]
F E D C B A AA AA A B C D E F
130 100 65 40 25 10 5 5 10 25 40 65 100 130
[34.3] [26.4] [17.2] [10.6] [6.6] [2.6] [1.3] [1.3] [2.6] [6.6] [10.6] [17.2] [26.4] [34.3]

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 61


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
- 9824 9823 9822 9821 9820 9825 - - - - - - -
BA

TPT
157-454.10

4-way, 4 position
Closed neutral position
P→A→F
- 9624 623 9622 9621 - - - - - - - - -

157-139.10 157-140.10

4-way, 4-position
Closed neutral position
Float P → B → F

FC spools for friction detent, PVMR

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min] ISO symbol Symbol Press. compensated flow: l/min [US gal/min]
E D C B A AA AA A B C D E
100 65 40 25 10 5 5 10 25 40 65 100
[26.4] [17.2] [10.6] [6.6] [2.6] [1.3] [1.3] [2.6] [6.6] [10.6] [17.2] [26.4]
9724 9723 9722 9721 9720 - - 9700 9701 9702 9703 9704

4-way, 3-position
closed neutral position
9734 9733 9732 9731 9730 - - 9710 9711 9712 9713 9714

4-way, 3-position
Throttled open neutral position

FC spools with linear flow characteristic

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min] ISO symbol Symbol Press. compensated flow: l/min [US gal/min]
F E D C B A AA AA A B C D E F
130 100 65 40 25 10 5 5 10 25 40 65 100 130
[34.3] [26.4] [17.2] [10.6] [6.6] [2.6] [1.3] [1.3] [2.6] [6.6] [10.6] [17.2] [26.4] [34.3]
- 9774 9773 9772 9771 - - - 9750 9751 9752 9753 9754 -

4-way, 3-position
Closed neutral position

62 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
- 9784 9783 9782 9781 - - - 9760 9761 9762 9763 9764 -

4-way, 3-position
Throttled, open neutral position
- - - - - - - - - - - - 9794 -

4-way, 3-position
Throttled, A → T in neutral position
- - - - - - - - - - - - 9804 -

4-way, 3-position
B → T in neutral position

Standard PC spools

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min] ISO symbol Symbol Press. compensated flow: l/min [US gal/min]
E D C B A AA AA A B C D E
100 65 40 25 10 5 5 10 25 40 65 100
[26.4] [17.2] [10.6] [6.6] [2.6] [1.3] [1.3] [2.6] [6.6] [10.6] [17.2] [26.4]
- 7033 7032 7031 7030 7035 7015 7010 7011 7012 7013 -

4-way, 3-position
Closed neutral position, PC → A and B
7134 7133 7132 7131 7130 7135 7115 7110 7111 7112 7113 -

4-way, 3-position Throttled, open neutral position,


PC → A and B
7064 7063 7062 7061 - - - 7040 7041 7042 7043 7044

4-way, 3-position
Closed neutral position, PC → A

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 63


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
7074 7073 7072 7071 - - - 7050 7051 7052 7053 7054

4-way, 3-position
Closed neutral position, PC → B
7164 7163 7162 7161 - - - 7150 7151 7152 7153 7154

4-way, 3-position
Throttled, open neutral position, PC → A
7174 7173 7172 7171 - - - 7150 7151 7152 7153 7154

4-way, 3-position
Throttled, open neutral position, PC → B
- 7473 7472 7471 7470 - - - - 7452 7453 -

4-way, 3-position
Throttled, A → T neutral position, PC → B
- 7563 7562 - - - - - 7541 7542 7543 -

4-way, 3-position
Throttled, B→ T neutral position , PC → A

Standard PC spools, hydraulic actuation

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
Press. compensated flow: l/min [US gal/min] ISO symbol Symbol Press. compensated flow: l/min [US gal/min]
E D C B A AA AA A B C D E
100 65 40 25 10 5 5 10 25 40 65 100
[26.4] [17.2] [10.6] [6.6] [2.6] [1.3] [1.3] [2.6] [6.6] [10.6] [17.2] [26.4]
- - - - - - 9015 9010 9011 9012 - -

4-way, 3-position
Closed neutral position, PC → A and B

64 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVB is with LSA/B shuttle valve Code number 157B.... PVB is without LSA/B shuttle valve
- - - - - - - - - 9042 9043 9044

4-way, 3-position
Closed neutral position, PC → A
- - - - - - - - - 9052 9053 9054

4-way, 3-position
Closed neutral position, PC → B

PVB, basic valves


0

0 c

1-13
16

14
a

15 c

V310168.A

PVB, basic valves


Description No facilities for shock valves A and B Facilities for shock valves A and B

G½ 7∕8 - 14 UNF G½ 7∕8 - 14 UNF


Without compensator /check valve 157B6000 157B6400 157B6030 157B6430
With check valve 157B6100 157B6500 157B6130 157B6530
With check valve and LSA/B shuttle valve - - 157B6136 157B6536
With compensator valve 157B6200 157B6600 157B6230 157B6630
With damped compensator valve 157B6206 - 157B6236 -
With compensator valve, LSA/B relief valve and LSA/B shuttle 157B6203 157B6603 157B6233 157B6633
valve

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 65


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVB, basic valves (continued)


Description No facilities for shock valves A and B Facilities for shock valves A and B

G½ 7∕8 - 14 UNF G½ 7∕8 - 14 UNF


With damped compensator valve, 157B6208 - 157B6238 -
LSA/B relief valve and LSA/B shuttle valve
Weight kg [lb] 3.1 [6.8] 3.0 [6.6]

PVPC, plugs
Description G 1/4 1/220 UNF Weight

kg [lb]
External pilot supply 157B5400 — 0.05 [0.1]
External pilot supply incl. check valve 157B5600 157B5700 0.05 [0.1]

PVM, mechanical actuation


Description Alu Alu anodized Cast iron Angle

with stop screws without stop with stop screws with stop screws
screws
Standard 157B3171 157B3191 157B3184 157B3161 22.5°/37.5°
Standard with base, without arm and button 157B3174 157B3194 — — 22.5°/37.5°
Standard without base, without arm and 157B3173 157B3193 157B3186 — —
button
Weight kg [lb] 0.4 [0.9] 0.8 [1.8]

PVAS, assembly kit


Code no. 0 1 2 3 4 5 6 7 8 9 10 11 12
157B....
PVB’s 8000 8001 8002 8003 8004 8005 8006 8007 8008 8009 8010 8061 8062
PVB + - 8021 8022 8023 8024 8025 8026 17B8027 8028 8029 8030 8081 8082
PVPVM
Weight 0.1 [0.2] 0.15 [0.3] 0.25 [0.6] 0.30 [0.7] 0.40 [0.9] 0.45 [1.0] 0.50 [1.1] 0.60 [1.3] 0.65 [1.4] 0.70 [1.6] 0.80 [1.7] 0.85 [1.8] 0.9 [2.0]
kg [lb]

PVP, pump side module

PVP, pump side module


Description Without pilot supply With pilot supply

for PVE for PVE with for PVE for PVE and for PVE and pilot for PVH and pilot
facilit. for PVPX facilit. for oil pressure take- oil pressure take-
PVPX off off
Open P = G1/2, T = G3/4 157B5000 - 157B5010 157B5012 - -
center
P = 7/8 -14, T = 11/16 -12 157B5200 - 157B5210 157B5212 - -
P = G3/4, T = G3/4 157B5100 157B5102 157B5110 157B5112 157B5180 157B5190
P = 1 1/16 -12, T = 11/16 -12 157B5300 - 157B5310 157B5312 157B5380 157B5390

66 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVP, pump side module (continued)


Description Without pilot supply With pilot supply

for PVE for PVE with for PVE for PVE and for PVE and pilot for PVH and pilot
facilit. for PVPX facilit. for oil pressure take- oil pressure take-
PVPX off off
Closed P = G1/2 , T = G3/4, 157B5001 - 157B5011 157B5013 - -
center
P = 7/8 -14, T = 11/16 -12 157B5201 - 157B5211 157B5213 - -
P = G3/4, T = G3/4, 157B5101 157B5103 157B5111 157B5113 157B5181 157B5191
P = 11/16 -12, T = 1 1/16 -12 157B5301 - 157B5311 157B5313 157B5381 157B5391
Weight kg [lb] 3 [6.6]

PVPX, electrical LS pressure relief valves


Description/ Code No. Hirsch. Code No. Weight
Supply voltage AMP kg [lb]
Normally open 12 V 157B4236 157B4981 0.3 [0.7]
24 V 157B4238 157B4982
Normally closed 12 V 157B4246 157B4983
24 V 157B4248 157B4984
Normally open with manual override 12 V 157B4256 157B4985
24 V 157B4258 157B4986
Plug 157B5601 0.06 [0.13]

PVS and PVSI, end plate


Description BSP SAE Weight
kg [lb]
PVS, without connections 157B2000 157B2020 0.5 [1.1]
PVS, with LX connection 157B2011 157B2021
G 1/8 [3/8 -24 UNF]
PVSI, without connections 157B2014 157B2004 1.7 [3.6]
PVSI, with LX connections 157B2015 157B2005
G 1/4 [1/2 -20 UNF]

PVLP, shock/ and anti-cavitation valves


Code no. 157B203 157B205 157B206 157B208 157B210 157B212 157B214 157B215 157B216 157B217 157B219
2 0 3 0 0 5 0 0 0 5 0
Settings bar 32 50 63 80 100 125 140 150 160 175 190
[psi] [460] [725] [914] [1160] [1450] [1813] [2031] [2175] [2320] [2538] [2755]

Code no. 157B221 157B223 157B224 157B225 157B226 157B228 157B230 157B232 157B235 157B238 157B240
0 0 0 0 5 0 0 0 0 0 0
Settings bar 210 230 240 250 265 280 300 320 350 380 400
[psi] [3045] [3335] [3480] [3625] [3845] [4061] [4351] [4641] [5075] [5511] [5801]

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 67


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVE, electrical actuation

PVE, electrical actuation


Description Code No. Weight
kg [lb]
Hirsch AMP Deut.
PVEO, on-off 12 V 157B4216 157B4901 157B4291 0.6 [1.3]
24 V 157B4228 157B4902 157B4292
PVEO-R, on/off 12 V 157B4217 157B4903 -
24 V 157B4229 157B4904 -
PVEM, prop. medium – 12 V 157B4116 - - 0.9 [2.0]
Standard
24 V 157B4128 - -
PVEM, prop. medium – Float 12 V 157B4416 - - 1.0 [2.2]
–>B
24 V 157B4428 - -
PVEA, active fault mon. - 157B4734 157B4792 0.9 [2.0]
PVEA, passive fault mon. - 157B4735 -
PVEA-DI, active fault mon. - 157B4736 157B4796
PVEA-DI, passive fault mon. - 157B4737 -
PVEH active fault mon. 157B4032 157B4034 157B4092 1.0 [2.2]
PVEH passive fault mon. 157B4033 157B4035 157B4093
PVEH float – > B, act. fault 157B4332 - 157B4392
PVEH float – > A, act. fault - 157B4338 -
PVEH- DI active fault mon. - 157B4036 157B4096
PVEH - DI passive fault mon. - 157B4037 -
PVES, active fault mon. 157B4832 157B4834 157B4892
PVES, passive fault mon. 157B4833 157B4835 -

PVMD, PVMR, PVMF, PVH covers


Description Code No. Material Anodized Weight

kg [lb]
PVMD 157B0001 aluminium no 0.1 [0.2]
Cover for PVB
157B0009 yes
157B0021 cast iron N/A 0.9 [2.0]
PVMR 157B0004 aluminium no 0.3 [0.6]
(Friction Detent)
157B0012 yes
157B0024 cast iron N/A
PVMF 157B0005 aluminium no
(Mech. float position)
Hydraulic actuation PVH 9/16-18 UNF 157B0007 aluminium no 0.2 [0.4]
157B0010 yes
157B0014 cast iron N/A
Hydraulic actuation PVH G1/4 157B0008 aluminium no
157B0011 yes
157B0016 cast iron N/A 0.9 [2.0]

68 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Module selection chart

PVLA, anti-cavitation valve


Description Code No. Weight

kg [lb]
Plug A or B 157B2002 0.04 [0.09]
Valve A or B 157B2001 0.05 [0.10]

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 69


Technical Information
PVG 32 Proportional Valve Group

Order specification

The form can be obtained from the Danfoss Sales Organization. An order form for PVG 32 hydraulic valve
is shown on the page PVG 32 order specification.
Both the module selection chart on the previous pages and the order form are divided into fields 0,
1-1-12, 13, 14, 15, a, b, and c.
Each module has its own field:
0:
• Pump side module PVP
• Plug for external pilot oil supply PVPC
• Electrical LS unloading valve PVPX

1-12: Basic valves PVB


13: Main spool PVBS
a: Mechanical actuator PVM (or PVE when option mounted)
b:
• Shock and suction valve PVLP
• Suction valve PVLA

c:
• Cover for mechanical actuation PVMD
• Cover for hydraulic actuation PVH
• Electrical actuators PVE (or PVM when option mounted)

14: End plate PVS


15: Assembly kit PVAS

Please state:
• Code numbers of all modules required
• Required setting (P) for pump side module
• Required setting of LSA/B pressure limiting valves, see pressure setting guidance below.

Standard and option assembly


The PVG 32 valve group is assembled the way the module selection chart shows if the code number for
PVM is written in field 'a', and the code number for PVMD, PVE or PVH in field 'c'.
The valve group is assembled so that the mechanical actuator is mounted on the opposite end of the
basic module, if the code number for PVM is written in field 'c' of the order form and the code numbers
for PVMD, PVE or PVH in field 'a'.

Reordering
The space at the top right-hand corner of the form is for Danfoss to fill in. The code number for the whole
of the specified valve group (PVG No.) is entered here.
In the event of a repeat order all you have to do is enter the number Danfoss has given on the initial
confirmation of order.

Pressure setting limits


The maximum setting pressure for the pressure limiting valves LSA or LSB depends on the chosen
pressure setting for shock valve PVLP. The maximum values recommended to avoid interaction can be
read in the following table.

70 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

Order specification

The figures in the table have been calculated according to the following expressions:
• PVLP ≤150 bar: LSA/B ≤ 0.8 × PPVLP
• PVLP >150 bar: PPVLP - LSA/B ≥ 30 bar.

Max. pressure setting of LSA and LSB valves relative to PVLP shock valve
Pressure for PVLP Max. for LSA/B Min. for LSA/B

bar [psi] bar [psi] bar [psi]


32 [460] - - 30 bar] [435 psi]
50 [725] 40 [580]
63 [914] 50 [720]
80 [1160] 64 [930]
100 [1450] 80 [1160]
125 [1813] 100 [1450]
140 [2031] 112 [1625]
150 [2175] 120 [1740]
160 [2320] 130 [1885]
175 [2838] 145 [2100]
190 [2755] 160 [2320]
210 [3045] 180 [2610]
230 [3335] 200 [2900]
240 [3480] 210 [3045]
250 [3625] 220 [3190]
265 [3843] 235 [3408]
280 [4061] 250 [3625]
300 [4351] 270 [3915]
320 [4641] 290 [4205]
350 5075 320 4641
380 5511 350 5075
400 5801 370 5366

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 71


Technical Information
PVG 32 Proportional Valve Group

Order specification

PVG 32 specification sheet

72 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 73


Technical Information
PVG 32 Proportional Valve Group

74 | © Danfoss | March 2016 520L0344 | BC00000038en-US0801


Technical Information
PVG 32 Proportional Valve Group

© Danfoss | March 2016 520L0344 | BC00000038en-US0801 | 75


Products we offer: Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electronic components. We specialize in providing state-of-the-art technology and solutions
• Bent Axis Motors
that excel in the harsh operating conditions of the mobile off-highway market. Building on
• Closed Circuit Axial Piston our extensive applications expertise, we work closely with our customers to ensure
Pumps and Motors exceptional performance for a broad range of off-highway vehicles.
• Displays
We help OEMs around the world speed up system development, reduce costs and bring
• Electrohydraulic Power vehicles to market faster.
Steering
• Electrohydraulics Danfoss – Your Strongest Partner in Mobile Hydraulics.

• Hydraulic Power Steering Go to www.powersolutions.danfoss.com for further product information.


• Integrated Systems Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support
• Joysticks and Control for our customers, ensuring the best possible solutions for outstanding performance. And
Handles with an extensive network of Global Service Partners, we also provide comprehensive global
service for all of our components.
• Microcontrollers and
Software Please contact the Danfoss Power Solution representative nearest you.
• Open Circuit Axial Piston
Pumps
• Orbital Motors
• PLUS+1® GUIDE
• Proportional Valves
• Sensors
• Steering
• Transit Mixer Drives

Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmueller- Local address:
inverter.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com

Danfoss
Power Solutions Trading
Danfoss Danfoss Danfoss (Shanghai) Co., Ltd.
Power Solutions (US) Company Power Solutions GmbH & Co. OHG Power Solutions ApS Building #22, No. 1000 Jin Hai Rd
2800 East 13th Street Krokamp 35 Nordborgvej 81 Jin Qiao, Pudong New District
Ames, IA 50010, USA D-24539 Neumünster, Germany DK-6430 Nordborg, Denmark Shanghai, China 201206
Phone: +1 515 239 6000 Phone: +49 4321 871 0 Phone: +45 7488 2222 Phone: +86 21 3418 5200

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

© Danfoss | March 2016 520L0344 | BC00000038en-US0801