PROCESS CONTROL INSTRUMENTATION

AIL 802P – MICROPROCESSOR BASED SIGNAL INDICATORS /


CONTROLLERS ( Fully configurable )
Technical Catalogue
Introduction
Programmable Microprocessor based Indicator cum Controller, AIL 802P is an ideal instrument for providing
indication as well as controlling set points to various processes. It is designed to accept various process inputs ( Current,
( 96*96, 0.5” display ) Voltage, RTD, Thermocouples, Resistances ) simultaneously i.e in UNIVERSAL manner or any one of these in PREDEFINED
manner. When UNIVERSAL manner, The user can configure from the front keys to select any one of the input automatically.
The user can also configure to set the range of linear inputs or calibrate the instrument without openint it. The AIL 802P
can give maximum 4 relay outputs. All the contact output related specs like – SETPOINT, ALARM TYPE, HYSTERISIS –
can be configured easily by the front panel keys itself. Retransmission facility is of course provided with all possible
configurations allowed by front keys as usual. The instrument can be optionally equipped with serial communication facility
to operate on MODBUS RTU protocols. Signle level password is there to keep the settings and configurations intact for the
right user only.
( 96*48, 0.5” display ) Low drift precession components are used for long term accuracy of the instruments. All instruments undergo a burn-in for
better reliability.The instrument is available in different formats and sizes. Information regarding specification and size is
given below.

Specifications
Inputs ( & Display range ) Analog output load capability
1)Current, 4 – 20 mA DC/ 0 – 20 mA DC ( -1999 to 9999) 800 maximum for current outputs
2)Voltage, 1 – 5V/0 – 10V (-1999 to 9999 ) Output accuracy
3)RTD Pt 100 – 3 wire ( -100.0 to 600.0 ) +/- 0.1% of span
( 96*48, 0.8” display ) 4)T/C Type J (-100 – 800)
5)T/C Type K (0 – 1200) Serial output with open protocol
6)T/C Type R (0 – 1760) 1)RS232 With modbus RTU protocol
7)T/C Type S (0 – 1700) 2)RS485 with modbus RTU protocol
8)T/C Type T (-100 – 400 ) Note: Any other protocol on demand
9)T/C Type B ( 450 to 1820 )
10)T/C Type E ( -100 to 1000 ) Transmitter power
11)T/C Type C 24 V DC for current inputs
12)Ohms-0-10K ohms ( -1999 to 9999 ) 10/12 V DC ( in case of Load cell/Proximity application)
13)mV DC Specials
( 72*72, 0.5” display ) 14)UNIVERSAL type 1 – 1…8 of above Power supply
15)UNIVERSAL type 2 – 1…13 of above 1)24 V DC
16)Pulse train input. ( open collector type )– 2)110 V AC, 50 Hz, +/- 10%
17)10 to 10 V DC / -mV to mV DC ( -1999to9999) 3)230 V AC, 50 Hz, +/- 10%
18)RTD – Cu 53 4)90-270 V AC, 50 Hz. – SMPS
19)Special type of inputs of any V/Current/Resistance 5)Specials
( However on factory confirmation only ) Security
·Decimal point configurable for linear inputs Single level Password protected
·T/C temperature displays without decimal point
( 72*72, with set point Contact ratings
display ) Input impedance 230 V AC, 5 Amps.
200 K for Voltage, mV & T/C inputs
upto 250 ohms for current inputs Power consumption
3 VA max.
Display resolution
3 digit Ambient temperature
4 digit 0 – 50 C.
* Display range is the virtue of its resolution
Storage temperature
Display accuracy 0 – 70 C.
+/- 0.1% of span
Humidity
( 48*48, predefined input ) Alarms 90% RH (non-condensing)
Yellow in spec803 Maximum 4 nos. of potential free contacts
( Din rail type ) Enclosures
Setpoint Display Weatherproof, Flameproof and all other standard types
Optional on a resolution of 3 or 4 digit
Mounting
Analog output Panel / Wall / Field / Dinrail / Eurocard / Specials
Maximum 2 nos. of any of below
1)Isolated / Non Isolated 4 – 20 mA DC Dimensions
2)Isolated / Non Isolated 0-10 V DC 96*96 / 96*48 / 72*72 / 48 * 48 / 72*144 / SPECIALS
3)Other types on factory confirmations *All config/calibration from front keys only

·Following table describes the availability of several models with the company right now. A general preview is only presented to the user. The
( din rail type ) dimensional and display sizes are the relational virtues of each other and hence the user is always requested to clarify the specifications of instrument
with the factory prior to placement of the order.
On confirmation with factory, changes of all types in all specifications is possible.
PROCESS CONTROL INSTRUMENTATION

Retrans-
mission Setpoin Process value Process
Mounting & Dimension Powe value
Model Inputs Bargraph Alarms Isolated or t Display
in mm (H * W) r Display size
Not- Display resolution

Isolated
All
48*96 All No Max.2 Max. 1 No 3/4 digit max. 0.25/0.5/0.8”
72*72 All All No Max.2 Max. 1 Yes 3/4 digit max. 0.25/0.5” ( din rail type )
Panel 96*96 All All Yes Max.4 Max. 2 Yes 3/4 digit max.. 0.25/0.5/1”
144*72 All All 51 LED Max.4 Max. 2 Yes 3/4 digit max.. 0.25/0.5/1”
AIL 72*144 All All 51 LED Max.4 Max. 2 Yes 3/4 digit max. 0.25/0.5/1”
802P 36*144 All SMPS 51 LED Max. 4 Max. 1 No 3/4max.ax.
digit max 0.25”
Din Rail 70*100 max All All No Max. 4 Max.1 No 3/4 digit max. 0.25/0.5”
Euro Std. or as req All All No Max. 4 Max. 2 No 3/4 digit max. 0.25/0.5”
As required or All
Depends on
Wall Optimum All Max. 4 Max.2 Yes 3/4 digit max. 0.25” to 1”
size
possible
In case the qty. permits, the instruments can be taken to the customized requirements. Contact factor for confirmation

( Euro Card format )


Ordering Information ( 12 digits )
Please confirm the availability of the model by cross checking the table mentioned on the backside.

Basic Model No. (Specified by first 3 digits) AIL 802P - Alarms Option (Specified by the third digit)
Signal Ind. cumController Microprocessor based and 0-None
Fully configurable 1-1 no. of alarm
2-2 no. of alarms
Enclosure / Mounting (Specified by letter following 3 digits)
3-3 no. of alarms
P-Weatherproof - Panel
4-4 no. of alarms
R-Weatherproof -Din Rail
E-Weatherproof - Euro card Analog O/P Option (Specified by the fourth digit)
W-Weatherproof - Wall 0-None
F-Flame proof – Wall / Field 1-1 no. mA/V DC isolated
( FLP enclosure )
I-IP65 grades – Wall / Field 2-2 no. mA/V DC isolated
S-Specials 3-1 no. mA/V DC N. I.
4-2 no. mA/V DC N.I
Input (Specified by first digit following the letter) S-Any other type of outptus
1-mA DC signal input
2-V/mV DC signal input Bargraph Option (Specified by the fifth digit)
3-RTD type 0-None
4-Thermocouple 1-YES
5-Resistances ( Edge cut, Single
Display Resolution (Specified by the sixth digit)
U-UNIVERSAL1 type Bargraph type )
V-UNIVERSAL2 type
1-2/3 digit
S-Specials / Others
2-4 digit
Communication output
Power Option (Specified by the second digit)
0-None
1-24 V DC
2-110 V AC
1-YES
3-230 V AC Setpoint Display
4-90-270 V AC – SMPS 0-None
S-Specials 1-YES

( Single channel
Bargraph Ind./Ct.)

( FLP enclosure )
An ISO 9001 : 2008 company
Corporate & Mktg. Office : 165, G.I.D.C. Makarpura, Vadodara 390 010. Tel. : +91 - 265 - 2643550, 2646021.
n Fax : + 91 - 265 - 2641054 n E-mail : marketing@altopindustries.com
Factory : 392 , 419-A, GIDC, Makarpura, Vadodara - 390 010.
n Tel. : 0265-2658480 n E-mail : support@altopindustries.com
PROCESS CONTROL INSTRUMENTATION
MUMBAI : 5, Turakhia Park, Shopping Complex, Building No. 1, Next to Corporation Bank, M. G. Road,
Kandivali (W) MUMBAI - 400 067. n Tel. : (022) 2806 6032 / 2806 6036 n Fax : (022) 2862 9113 CIN - U91110GJ1993PLC018831
n Email : bombay@altopindustries.com http://www.altopindustries.com

You might also like