Measurably better value

BIG ON PERFORMANCE
SMALL ON SIZE

Hero shot (to be provided)

1.3HGz and 2.7GHz


-105dBm Noise Floor
Touch or Hard Key Control

PSA SERIES 3
PSA1303 & PSA2703
RF Spectrum Analyzers
aimtti.com
BIG
PERFORMANCE
Twin markers, Peak track
-105dBm noise floor
Peak track smart markers

Frequency pre-set and setup store live view and reference traces

Trace modes, Normal, Peak Resolution Bandwidths


and Trace Average 300Hz to 10MHz 1:3:10

U01* Extended feature set: Truly portable, only 0.58 kg


limit lines, data logging,
sweep trigger Compensation
tables Custom presets

A lightweight and truly handheld


instrument that incorporates an extensive
feature set. A ruggedized casing with a
removable sun screen/screen protector to
enhance field use. The 4.3” TFT with 3 row
hierarchical menu system provides rapid
access to all features. Additional Hard
keys are provided for marker movement
and short cuts to major functions. On
time is almost instant with the first sweep
available in under 2 seconds.
Addition of the U01 upgrade adds
additional limit lines and patterns, data
Logging, Sweep Triggers, Compensation
tables, Custom Pre-sets and View on PC
capability.

PRODUCT APPLICATIONS
The PSA S3 will find many applications
within radio communication field
environments such as:
Interference Analysis
Antenna Alignment
Signal Strength Mapping
Covert Transmitter Detection
Spurious Emissions
EMC Frequency Evaluations
KEY
FEATURES
f 1MHz to 1300MHz or 2700MHz frequency range f Custom Presets. Capability to show screen
contents on a PC
f Resolution bandwidths of 300Hz to 10MHz 1:3:10
f -105dBm typical noise floor at -40dBm reference
level
f Measurement in dBm or dBµV, mV or µW
f Zero span mode with AM and FM audio
demodulation
f Trace modes of normal, peak hold and trace
average
f Live, View and Reference traces in contrasting
colours
f Twin markers with readout of absolute &
difference values
f Smart marker movement with selectable peak
tracking

f Frequency counter with 10Hz Resolution

f Frequency presets and independent state storage

f Auto-find automatically sets sweep parameters


for the highest signal found
f Unlimited storage for waveforms, set-ups and
screens
f User assignable file names, file stamping from
real-time clock
f USB interfaces for Flash drives and PC connection
f Comprehensive status and context sensitive help
screens
f More than 3 hours continuous operation from a
charge

f Smaller and lighter than other spectrum analyzers


(weight only 0.58 kg)

OPTION U01 ADDS:


f Limit lines and limit patterns with limits
comparator
f Data logging of peak values, complete traces or
screen images from timer, external trigger or
limits comparator
f Sweep triggering from external trigger or limits
comparator
f Compensation tables, fixed offsets and 75W
compensation
SMALL ON SIZE...

BATTERY OPERATION OF MORE THAN 3


HOURS
The PSA Series 3 operates from a Li-ion rechargeable battery
that can provide more than 3 hours of continuous operation.
Can also be set to switch off automatically after a set time
from the last action.
For continuous bench top operation, powered from its AC
adapter which also recharges the batteries in less than 3
hours.
On pressing the power button, the instrument comes to life
almost instantly, with the first sweep available in under 2
seconds.

GENUINELY HAND-HELD
The PSA Series 3 is sufficiently small and lightweight to fit
comfortably into the hand
A removable screen protector and sun-shield combines with
rubberised buffers top and bottom to enhance its use in the
field.
The casing of the PSA Series 3 includes rubberised buffers
top and bottom to help resist knocks and scratches. The tilt
stand can be moved to the top of the instrument to act as a
screen protector when in transit. In this position it also acts
as a sun-shield when in the field.
With a width of only 92mm (3.6”) and a weight of only 580
grams (20 oz) the PSA fits comfortably into the hand.

TOUCH-SCREEN OR HARD-KEY CONTROL


The three-row hierarchical menu system provides rapid
intuitive access to all functions. Additional hard keys are
provided for marker movement and shortcuts to major
functions. Alternatively, all of the functions can be operated
with just the hard keys by using the five way navigator in a
tab-enter-jog mode.

...BIG ON PERFORMANCE
PACKED WITH VERTICAL EXPANSION
The vertical resolution of 10dB per division can be expanded to
5dB, 2dB or 1dB with panning over the full dynamic range.

FEATURES TRACE WRITE MODES


In addition to the normal mode, the trace can be set to display
Peak-hold, or a Multi-sweep Average.

INTUITIVE MENU SYSTEM ZERO SPAN AUDIO DEMODULATION


Ease of use was a major consideration in the design of the PSA The PSA Series 3 includes a zero span mode with both AM or FM
Series 3. The menu system provides rapid access to menu groups, audio demodulation. The audio signal, with variable volume and
each of which has sub menus, each with their own function keys. selectable low-pass filter, is available from the built-in
loudspeaker or from a standard 3.5mm jack socket.

CONTEXT SENSITIVE HELP


Context sensitive help is available for every menu, along with a
full topics list of help information.

Function keys perform direct actions or create pop-up menus or EXTENSIVE DATA STORAGE
dialogue boxes. Frequencies can be set by direct numeric entry,
The PSA Series 3 can store large amounts of data using its internal
or by a digit increment system.
memory supplemented, if necessary, by USB Flash drives.
Centre, Start and Stop can be stepped by any chosen increment.
The filing system can store trace and state files, screen images,
Span can be zoomed.
set-up files, logging files*, limit patterns* and compensation
Single key shortcuts include Set to Peak, Set to Marker and Set tables*.
between Markers (Start=M1, Stop=M2).
Files are stored under either default file names, or user-chosen
Frequency presets enable fast changes between frequently used file names entered from an alpha-numeric keypad.
sweep ranges.
Files are time-stamped from the real-time clock, and can be listed
by date or name.
LIVE, VIEW AND REFERENCE TRACES The illustration is a
A view trace and reference truncated version of
trace can be displayed in the real screen image
addition to the live trace which can list 20 files
using contrasting colours simultaneously. Each
for clarity. Any number directory can contain up to
of traces can be saved to 999 files.
memory and rapidly recalled *Logging files, limit
to the screen. Trace states patterns and compensation
are saved in addition to the tables are only available
traces and can be recalled with Option U01 - see next
separately. page.

SMART MARKER MOVEMENT DATA EXPORT AND TRANSFER


Dual markers provide an on-screen readout of frequency and USB device and host connectors are provided enabling the PSA
level including difference values. Series 3 to be linked directly to a PC for file transfer, and for the
The markers can be set to connection of USB Flash drives for data transfer or storage.
specified frequency values, Trace files have a standard comma separated value (.csv) format
scrolled across the screen, which can be imported into other applications such as Excel or
or set to automatically MathCad. Screen images are stored as standard bit-maps that can
find peaks. A peak tracking be manipulated and printed using a PC as well as being recalled
mode is also provided to the PSA screen.
which will track the highest
peak in the sweep despite
changing frequency.
FULL STATUS DISPLAY
In addition to the extensive on-screen status information, a single
Marker amplitude readout
button press reveals the complete set-up of the instrument as a
can be in graticule units
screen listing.
(dBm or dBµV) or in linear
units (mV or µW). All settings are retained when at power-down, and any number of
set-up files can be stored under automatic or user names.
EXTENDED FEATURES
OPTION U01
Option U01 is a firmware upgrade that increases the capabilities
of the PSA series 3 to include the following features

TRIGGERED SWEEP* DATA LOGGING*


The standard sweep modes of continuous repeat and single shot The PSA Series 3 can log results in response to a variety of stimuli.
can be extended to include triggered sweeps from an external Data is stored as files that can be transferred to a PC for analysis
signal or internal limits comparison. using PSA-Manager software.
Logging entries can be
LIMIT PATTERNS AND LIMITS COMPARATOR* created by an internal
Limit lines and patterns can be defined which can be simply visual timer (adjustable from
aids or create automatic actions. Zone restriction can be applied. seconds up to hours), the
manual trigger key, the
A single or dual line limits comparator can be used to generate
external trigger input, or
audible warnings, output signals, or to freeze or log the trace.
the limits comparator.

OFFSETS AND COMPENSATION TABLES* VIEW ON PC*


The reference level, graticule and marker readouts can be set to
View on PC enables the screen of the spectrum analyzer to be
compensate for external attenuation or gain to a resolution of
sent to a PC by USB. The screen image can be set to a user
0.1dB.
definable size and is particularly useful for education and training
Compensation can also be added for signals emanating from a purposes.
75W source.
Tables can be loaded
that compensate for
variations of level
with frequency for
specific antennae
or transducers. The
tables can contain up
to 100 points and are
linearly interpolated
between points.

TEST BRIDGE PSA

Test Bridge PSA is a free application


operating under Windows that
provides useful file display and
PSA creation facilities.
Test Bridge can display trace files
which can be printed or exported to
other applications.
For instruments with option U01
fitted, Test Bridge provides full
display and analysis of logging files,
create limit pattern files, channel
marker lists, and compensation
tables, display live PSA screen
updates.
OPTIONS AND
ACCESSORIES

f FIRMWARE UPGRADE U01 f TRAVEL CASE f CONNECTION KIT


Option U01 is a firmware upgrade that can This soft fitted case offers high impact The connection kit comprises a high
be purchased and installed by the user at resilience. It provides protection for the quality SMA terminated cable along with
any time. It increases the capabilities of PSA1303 or PSA2703 when in transit, and SMA to N type adaptors for connection to
the PSA1303 or PSA2703 has storage space for the power adaptor, the PSA and to a generator. The cable has
Note: Option U01 is pre-installed within cables, and other accessories. low losses up to 6GHz.
the PSA1303USC and PSA2703USC Order code: PSA-SC A BNC to N type adaptor is also included
products. Note: The case is included within the enabling standard BNC cables to be used
PSA1303USC and PSA2703USC products. for lower frequency applications.
f TELESCOPIC ANTENNA Order Code : PSA-CK
This wideband antenna is intended for
general purpose applications where
absolute measurements of field strength
are not required.
The antenna is a high quality unit with
a knuckle joint hinge terminating with a
BNC connector. An N to BNC adaptor is
provided for direct
connection to the
instrument.
The length is
adjustable between
7.5cm and 35cm. The
useful bandwidth
is specified by the
manufacturer as
30MHz to 1.8GHz.
The resonant
frequency as a quarter
wave mono-pole is
adjustable between
f USC VERSIONS
approximately SUPPLIED ITEMS
200MHz and 1.0GHz. The PSA1303USC and PSA2703USC are
extended versions of the product that f STANDARD PRODUCT
Order Code: WB-ANT
include the firmware upgrade (U01), the
Note: The antenna is included within the PSA1303 or PSA2703 spectrum analyzer.
travel case, telescopic antenna and car
PSA1303USC and PSA2703USC products. charger. Universal voltage mains adaptor/charger.
The firmware upgrade is pre-installed USB connection lead.
f VEHICLE CHARGER
and all of the accessories, including the Spare stylus.
A vehicle charger operating from either
antenna and car charger, are supplied BNC converter for trigger input.
12V or 24V supplies is available. It is
within the fitted case. Safety documentation (multi-language)
capable of both recharging and operating
the spectrum analyzer.
f USC PRODUCT
Order Code: PSA-VC
All of the ‘standard product’ items are
Note: The charger is included within the supplied plus the following:
PSA1303USC and PSA2703USC products
Firmware Upgrade U01 (installed)
Telescopic Antenna WB-ANT
Vehicle Charger PSA-VC
Travel Case PSA-SC
.
TECHNICAL SPECIFICATION
FREQUENCY MEASUREMENT
DISPLAYED AVERAGE NOISE LEVEL (DANL)
FREQUENCY SPAN:
DANL: Better than – 105 dBm (2 dBuV) average displayed
Frequency Range: 1 MHz to 1300 MHz (PSA1303) noise floor (ref. level = – 40 dBm, RBW = 10 kHz, VBW
1 MHz to 2700 MHz (PSA2703) = 1 kHz, span 1 MHz) for frequency range 1MHz to
2.7MHz
Setting Modes: Centre frequency plus Span, or Start frequency plus
Stop frequency Noise per Hz: Better than -145 dBm/Hz equivalent
Maximum Span: 1299 MHz (PSA1303) DISTORTION AND SPURII
2699 MHz (PSA2703)
3rd Order < –60dBc for two signals at 10dB below reference
Minimum Span: 27 kHz, or Zero Span with demodulation Intermodulation: level, (500MHz and 502MHz); typically < -65dBc
Set. Resolution: 100 Hz at any frequency Harmonic: < –60dBc at 10dB below reference level (100MHz)
Setting Accuracy: Reference Frequency Accuracy for Start, Stop & Other Signal Related <-57 dBc for signals 10 dB below the reference level
Centre (Zero-Span) frequencies Spurii:
REFERENCE FREQUENCY ACCURACY Residual Spurii: <-70 dB below the reference level
Initial Accuracy: Better than ± 1 ppm at 20 °C SINGAL INPUT
Stability: Better than ± 1 ppm over 10 °C to 30 °C Input Connector N Type, 50 Ω
Ageing: Better than ± 1 ppm per year VSWR: 1.3 : 1 typical
PHASE NOISE (TYPICAL) Maximum Level: + 23 dBm, (130 dBμV) >50MHz; +/-50V DC
Phase Noise Phase noise at 100 kHz offset at 500 MHz typically SWEEP
-88 dBc/Hz
Sweep Method: Detection for 271 points per sweep. The amplitude
RESOLUTION BANDWIDTH value (as determined by the detection mode) from
each sub-span is stored (sub-span = span/270)
RBW: Selectable between 10 MHz and 300 Hz
selectable in 1:3:10 sequence, or Auto Signal Detection Alternate Peak (default), Positive Peak, Negative Peak,
Modes: Sample, Linear Average, Log Average or RMS
Video Filtering: Selectable between 10 MHz and 300 Hz
selectable in 1:3:10 sequence, or RBW Tracking Sweep Time: Sweep time is an automatic function of Span and
RBW/VBW.
MARKERS A speed-up function enables the time to be reduced
by a factor of up to ten.
No. of Markers: One, Two (or None)
Sweep Modes: Repeat (continuous) or Single Shot.
Resolution: 0.1 kHz at all frequencies
Sweep Trigger (only Trigger Source: External input or Limits Comparator.
Marker Accuracy: 1/270th of Span ± 10Hz plus reference frequency with Option U01)
accuracy.
Readout: The frequencies at the marker points and the DEMODULATION (ZERO SPAN MODE)
frequency difference are displayed
AUDIO DEMODULATION
Functions: Normal (Scroll Mode) and Peak Find Mode (as
standard) Modes: AM or FM
Peak Track Mode and Frequency Measurement (only
with Option U01) Internal Audio: Internal loudspeaker with adjustable volume and
mute.
AMPLITUDE MEASUREMENT Audio Out: 30 mW into 32 Ω mono or stereo headphones,
adjustable volume, 3.5mm jack socket
AMPLITUDE RANGE Audio Filter: Switchable 3kHz Low Pass Filter.
Units: Selectable as dBm or dBμV Carrier Display: Horizontal line at carrier level.
Display Range: 84 dB from reference level
DISPLAY & TRACES
Magnification: x2, x5 or x10
Display Type: 4.3 inch (10.9 cm) backlit TFT LCD, 480 x 272 pixels
Reference Level: Selectable between -40dBm and +10 dBm total, 16 colors, resistive touch screen.
(67dBμV to 117dBμV) in 1dB steps
Trace Area: 232 x 272 pixels.
AMPLITUDE ACCURACY Graticule: 8.5 x 10 divisions, light grey graticule.
Calibration Level Better than ± 1 dB at 10dB below ref. level @ Displayed Points: 271 points per sweep.
Accuracy: 2000MHz (20°C ± 5°C)
Live Trace: Dot-joined trace from current sweep.
Flatness: Better than ± 1 dB relative to 2000MHz over the full
operating frequency range Trace Modes: Normal (overwrite), Peak Hold, or Average (2 to 48
sweeps).
Linearity: Better than ± 1 dB over 60dB range down from the
reference level View Trace: Buffered “instance” of the live trace.
MARKERS Reference Trace: Stored trace recalled from a trace file.
No. of Markers: One, Two (or None) Dual Trace Mode: For Peak Hold and Average modes, processed and un-
processed traces can be displayed simultaneously.
Resolution: 0.1 dB
DATA LOGGING (ONLY WITH OPTION U01)
Readout: The level at the marker points and difference are
displayed. Data Types: Peak level, Centre Level, Full Trace or Screen Image.
Displayed Units: dBm, dBuV, mV or uW Data Entries: Up to 25,000 entries per file (2500 for Images).
Functions: Normal (Scroll Mode), Peak Find Mode, Peak Track Trigger Source: Entries can be made every sweep or in response to
Mode, Frequency Measurement Manual Trigger key, External Trigger, Internal Timer or
Limits Comparator
Internal Timer: Adjustable from 2secs. to 100mins per entry.
INTERNAL STORAGE OPTION U01
Internal Disk: 1.8GB of internal memory. Option U01 is a firmware upgrade that provides additional capabilities as follows:
External Storage: USB host interface for removable USB Flash drives. MARKERS
Store Trace: Up to 999 traces can be stored under either default Functions: Peak Track Mode, Frequency Measurement
file names or user entered file names. Traces are
stored as tables of amplitude versus frequency and LIMIT LINES AND PATTERNS
can be imported into other programs, as well as being
recalled to the screen. Limits: Up to two limits can be displayed together.
Lines are defined by dB value, Patterns are created as
Recall Trace: Recalls any stored trace to the reference trace of the files by PSA-Manager and loaded from memory (999
display. files maximum).
Store Set-up: Up to 999 instrument set-ups can be stored under Comparator: Comparison of trace or trace segment with limits
either default file names or user entered file names. (above/below/between/outside) can generate trigger
All settings of the instrument are saved. signal, pulse, or audio alert.
Recall Set-up: Recalls any stored set-up, overwriting the existing
settings of the instrument. DATA LOGGING
Store Screen: This function copies the whole screen area to Data Types: Peak level, Centre Level, Full Trace or Screen Image.
memory as a bit-map. Up to 999 screens can be Data Entries: Up to 25,000 entries per file (2500 for Images).
stored under either default file names or user entered
file names. Trigger Source: Entries can be made in response to Manual Trigger
key, External Trigger, Internal Timer (2s to 100m per
Recall Screen: Recalls any stored screen as an image. entry) or Limits Comparator
CONNECTOR SWEEP TRIGGER
RF Input: Standard N Type connector. Source: External Trigger or Limits Comparator.
DC Power: 1.3 mm power socket for external power supply/
charger OFFSETS AND COMPENSATION TABLES
USB Host: Standard USB type A connector for connection of USB Fixed Offsets: Compensation for external gain or attenuation from
Flash drives. -50.0dB to +50.0dB.

USB Device: Mini USB connector for connection to a PC. 75 Ohm: Compensation for signals from a 75W source.

Audio Out: 3.5 mm jack socket for demodulated audio out Tables: Compensation for variations of level with frequency
(accepts mono or stereo plugs). for antennae or transducers. Tables are created as
files by PSA-Manager and loaded from memory (999
Trigger In/Out: For use with option U01 only. files maximum).

POWER SOURCES CUSTOM PRESETS


Enables rapid switching between setups for repetitive testing.
BATTERY VIEW ON PC
Battery Type: Li-ion 3.7V 3000mA-hr Enables the screen of the spectrum analyzer to be sent to a PC via USB and
displayed at a user-defined size.
Battery Life: Greater than 3 hours continuous
Recharge Time: < 3 hours from fully discharged Thurlby Thandar Instruments Ltd. Operates a policy of continuous development
and reserves the right to alter specifications without prior notice.
Auto Off Mode: To conserve battery life, the system can be set to
automatically switch off after a defined time from the
last key press. This can be set between 5 mins and 60
mins (or never).
Battery Status: Multi-segment battery status indicator.

AC LINE OPERATION/ CHARGING


The instruments can be operated continuously from mains power using the AC
line adaptor provided. This powers and recharges the instrument simultaneously.
Voltage Range: 100V to 240V nominal 50Hz/60Hz

MECHANICAL
Size: 192mm high x 92mm wide x 49mm deep (height
excludes RF input connector)
Weight: 580 grms.
Tilt Stand: Built-in tilt stand for bench use which angles the unit
at 40 degrees to the horizontal.
Stylus: Casing incorporates plug-in stylus.

ENVIRONMENTAL AND SAFETY


Operating Range: +5°C to + 40°C, 20% to 80% relative humidity and
non-condensing
Storage Range: -10°C to +50°C
Environmental: Use at altitudes to 2000m, Pollution Degree 2.
Electrical Safety: Complies with EN61010-1.
EMC: Complies with EN61326.
Measurably better value
RF & EMC TEST EQUIPMENT

PSA1303 PSA2703 PSA3605 PSA6005


SPECTRUM ANALYSER SPECTRUM ANALYSER SPECTRUM ANALYSER SPECTRUM ANALYSER

1MHz to 1.3GHz 1MHz to 2.7GHz 10MHz to 3.6GHz 10MHz to 6GHz

3HRS BATTERY LIFE 3HRS BATTERY LIFE 3.5HRS BATTERY LIFE 3.5HRS BATTERY LIFE

0.58KG 0.58KG 0.56KG 0.5KG

RS-232 RS-232 RS-232 RS-232

TGR6000 TGR2051 TGR2053


RF SIGNAL GENERATOR RF SIGNAL GENERATOR RF SIGNAL GENERATOR

10MHz to 6GHz 150kH� to 1.5GHz 150kHz to 3GHz

-110dBm to +7dBm -127dBm TO +13dBm -127dBm TO +13dBm

SWEEP MODES MODULATION & SWEEP MODES MODULATION & SWEEP MODES

RS232, USB, LAN, GPIB RS232, USB, LAN, GPIB* RS232, USB, LAN, GPIB*

HA1600A AC1000A
HARMONICS ANALYSER LOW-DISTORTION SOURCE

EN61000-3-2/3 TESTING EN61000-3-2 TESTING

TABULAR & HISTOGRAM 1kw

PC SOFTWARE

RS-232, USB -

*GPIB optional
OTHER RANGES AVAILABLE

POWER SUPPLIES & LOADS

LINEAR MIXED-MODE POWERFLEX ELECTRONIC


POWER SUPPLIES POWER SUPPLIES POWER SUPPLIES DC LOADS

� 30w to 1200w Single and Multi channel PSUs for bench-top or remote control and system use.
� Flexible electronic DC loads for general purpose applications.

WAVEFORM GENERATORS

ANALOG DIGITAL
PULSE GENERATORS ARBITRARY GENERATORS
FUNCTION GENERATORS FUNCTION GENERATORS

� Analog and Digital (DDS) function generators with frequency capability up to 240MHz.
� Dedicated pulse generators with true pulse capability.
� True variable-clock arbitrary generators with up to four channels.

PRECISION MEASUREMENT

POSITIONAL FREQUENCY COMPONENT


MULTIMETERS MEASUREMENT MEASUREMENT
CURRENT PROBES

� Bench-top digital multimeters for dual display, system and logging.


� Innovative DC to 5MHz current probes for PCB tracks.
� Handheld and bench-top frequency counters up to 6GHz.
� Precision component measurements.

Visit www.aimtti.com for full ranges and further information.


EXCELLENCE THROUGH EXPERIENCE
Aim-TTi is the trading name of Thurlby Thandar
Instruments Ltd. (TTi), one of Europe’s leading
manufacturers of test and measurement instruments.
The company has wide experience in the design and
manufacture of advanced test instruments and power
supplies built up over more than thirty years.
The company is based in the United Kingdom, and all
products are built at the main facility in Huntingdon,
close to the famous university city of Cambridge.

TRACEABLE QUALITY SYSTEMS


TTi is an ISO9001 registered company operating
fully traceable quality systems for all processes
from design through to final calibration.

ISO9001:2015
Certificate number FM 20695

WHERE TO BUY AIM-TTI PRODUCTS


Aim-TTi products are widely available from
a network of distributors and agents in more
than sixty countries across the world.
To find your local distributor, please visit our
website which provides full contact details.

www.aimtti.com

Designed and built in Europe by:


E D I N TH
GN E
SI

UK
DE

Thurlby Thandar Instruments Ltd.


Glebe Road, Huntingdon, Cambridgeshire.
PE29 7DR United Kingdom
MAN

Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409


EU

Email: sales@aimtti.com Web: www.aimtti.com


FA
TH
U

CTU N
RED I 82100-1920 01

You might also like