0DLQ3URWHFWLRQ

'LUHFWLRQDO2YHUFXUUHQW3URWHFWLRQ$UJXV65

Product description Variants Order No.


               

'LUHFWLRQDO2&5HOD\ $UJXV  6 5   
Ź
Ź  Ź Ź $ Ź Ź  Ź Ź $ 
Ź
Directional overcurrent and Protection Product         
earth fault protection relay Overcurrent – Directional         
       
Housing I/O and Fascia        
1 CT, 3VT, 3 Binary Inputs / 5 Binary Outputs, 10 LEDs       & 
4 CT, 3VT, 3 Binary Inputs / 5 Binary Outputs, 10 LEDs        
4 CT, 3VT, 6 Binary Inputs / 8 Binary Outputs, 10 LEDs        
4 CT, 3VT, 4 Binary Inputs / 8 Binary Outputs, 10 LEDs 8)        

3URWHFWLRQ
      

Reyrolle
Measuring Input       
1/5 A, 50/60Hz 1)       
1/5 A, 50/60Hz with SEF Input 2)       
     
Auxiliary voltage      
DC 80 to 250 V,AC 115 V 5), binary input threshold DC 19V *     
DC 80 to 250 V, binary input threshold DC 88V +     
DC 24 to 60 V, binary input threshold DC 19V -     
    
Communication Interface     
Standard version – included in all models, USB front port, RS485 rear port (E4 Case)     
Standard version – plus additional rear electrical Ethernet RJ45 (x2), E6 Case 6)     
Standard version – plus additional rear optical Ethernet duplex (x2), E6 Case 6 )     
   
Protocol    
IEC 60870-5-103, Modbus RTU and DNP3 (user selectable)    
IEC 60870-5-103 Modbus RTU, DNP3 and IEC 61850 (user selectable settings) 6)    
  
Relay Cover   
Standard Version – No Push Buttons   
Push Buttons – Down and Right Arrows   
 
Protection Function Packages  
Standard version – Included in all models & 
27/59 Under/overvoltage  
32 3) Power  
32S 7) Sensitive Power  
37 Undercurrent  
46BC 3) Broken conductor/load unbalance  
46NPS 3) Negative phase sequence overcurrent  
47 Negative phase sequence voltage  
49 3) Thermal overload  
50AFD Arc Flash Detection  
50BF 3) Circuit breaker fail  
51V 3) Voltage controlled overcurrent  
55 3) Power Factor  
59N Neutral voltage displacement  
1) 4CT is configured as 3PF + EF 60CTS 3) CT supervision  
2) 4CT is configured as 3PF + 60VTS 3) VT supervision  
SEF/REF (user selectable 64H High Impedance REF  
setting) 67/50 Directional instantaneous phase fault overcurrent  
3) Functions only available in 4CT 67/50G 67/50N Directional instantaneous earth fault  
relay 67/50SEF 2) Instantaneous sensitive earth fault  
4) Not available on single-pole SEF 67/51 Directional time delayed phase fault overcurrent  
variant 67/51G 67/51N Directional time delayed earth fault  
5) 115V AC supported by devices 67/51/SEF 2) Time delayed sensitive earth fault  
with hardware version CC or 81HBL2 4) 2nd harmonic block/inrush restraint  
later 74T/CC Trip & Close circuit supervision  
6) E4 case is standard, E6 case is 51C3) Cold load pickup  
required if IEC61850 option fitted 81U/0 Under/Over Frequency  
7) 4 Binary Input variant provides 86 Hand reset contacts  
segregated Binary Outputs Programmable logic  
without a common terminal Standard version – plus  
8) Functions only available in 4CT 79 Autoreclose ' 
SEF relay 
Additional Functionality 
No Additional Functionality $