Tarek
Tarek
Abstract :
This project studies different ways of controlling induction motor speed and also
induction motor start , the new technology has development a batter ways to limit the
huge current of the induction motor when its begin to start , however this project will
show the design of the circuit and the analyses of the circuit for controlling the speed of
induction motor using modern equipment from power electronic device like thyristor
and other equipment . and will show the way and the result of the simulation
2
Electric Motors
One way of classifying electric motors is by the type of power they consume. Using this
approach, we may state that all electric motors fall into one or the other of the two
categories, AC or DC. AC motors are those that run on alternating current or AC power, and
DC motors are those that run on direct current, or DC power. AC motors work by setting up
a magnetic field pattern that rotates with respect to the stator and then employing
electromagnetic forces to entrain the rotor in the rotating magnetic field pattern.
3
1.1 Motor Selection
The motor may be selected according to Cost , Efficiency, Thermal capacity, Torque-speed
profile, Acceleration, Power density, volume of the motor, Peak torque capability,……etc.
Among all the existing motors on the market there are three classical motors: the DC motor
type, and two Alternative Current AC motors the synchronous motor type and the induction
motor type.
4
1.3.BAsic Construction
The AC induction motor comprises two electromagnetic parts:
• Stationary part called the stator
• Rotating part called the rotor, supported at each end on bearings
In most electric motors, rotor and stator are made of highly magnetically permeable materials
- steel or iron. In many common motors, rotor and stator are made of thin sheets of silicon
steel (laminations). Punched into these sheets are slots which contain rotor and stator
conductors.
A - The Stator
The stator is the outer stationary part of the motor, which consists of:
The outer cylindrical frame of the motor, which is made either of welded sheet steel, cast
iron or cast aluminum alloy. This may include feet or a flange for mounting, The magnetic
path, which comprises a set of slotted steel laminations pressed into the cylindrical space
inside the outer frame. The magnetic path is laminated to reduce eddy currents, lower losses
and lower heating, and a set of insulated electrical windings, which are placed inside the
slots of the laminated magnetic path. The cross-sectional area of these windings must be
large enough for the power rating of the motor. For a 3-phase motor, 3 sets of windings are
required, one for each phase.
B - The Rotor
This is the rotating part of the motor. As with the stator above, the rotor consists of a set of
slotted steel laminations pressed together in the form of a cylindrical magnetic path and the
electrical circuit. The electrical circuit of the rotor can be either:
5
direct contact with the steel laminations, practically all the rotor current flows through the
aluminum bars and not in the laminations.
6
Most widely spread induction motor is the squirrel cage motor because of its good self-
starting capability, more efficient, require lower maintenance, and rugged structure.
7
1.5 The Equivalent Circuit
To understand the performance of an AC induction motor it is useful to electrically represent
the motor by an equivalent circuit. This clarifies what happens in the motor when stator
voltage and frequency are changed or when the load torque and slip are changed. There are
many different versions of the equivalent circuit, which depend on the level of detail and
complexity.
Where
V = Stator supply voltage RS = Stator resistance
ES = Stator induced voltage XS = Stator leakage reactance at 50 Hz
ER = Rotor induced voltage RR = Rotor resistance
NS = Stator turns XR = Rotor leakage reactance
NR = Rotor turns XM = Magnetizing inductance
IS = Stator current RC = Core losses
IR = Rotor current
IM = Magnetizing current
The main components of the motor electrical equivalent circuit are:
• Resistances represent the resistive losses in an induction motor
• Inductances represent the leakage reactance. These are associated with the fact that not all
the flux produced by the stator windings cross the air-gap to link with the rotor windings and
not all of the rotor flux enters the air-gap to produce torque.
8
The equivalent circuit can be re-arranged and simplified as shown in the figure 1.8 below.
Where
X'R = N2 × XR
R'R = N2 × RR
N = NS/NR, the stator/rotor turns ratio
In contrast with a DC motor, the AC induction motor does not have separate field windings.
As shown in the equivalent circuit, the stator current therefore serves a double purpose:
• It carries the current (IM) which provides the rotating magnetic field
• It carries the current (IR) which is transferred to the rotor to provide shaft torque
9
Control circuit design and simulation
10
Objective :
To control the speed of the three phase induction motor using power electronic
component
Theory:
Th snober circuit:
It is essential for diode used in switching it can save the diode from over voltage peaks avery
common snubeer circuit for power diode consist from capacitor and resistor connected in
parallel with diode .
Diode:
It is the most common device used in power system it is circuit very simple its consist of tow
part and cathode if the anode terminal has higher potential than the cathode it well be
forward and also the current well be forward in this case small voltage drop will happen
almost less than one if the diode reversed it well not conduct
Thyristor: the thyristor called silicon control rectifier it is four layer three junction it has
three terminals :anode cathode and gate its on when we apply the pulls on the gate but as the
device on the gate cannot switched off aging. The device can turned off by applying reveres
gate an anode and cathode ,there are tow calcification for this device, converter gate and
inverter gate the low turn off time for latter
11
Zero crossing point :
shows the logic used in zero crossing detector-block. The zero crossing is detected by simple
logic circuit and an external analog comparator. Zero crossing comparator output is a square
waveform has a +V value with the positive half cycle of phase voltage and 0 with the
negative half cycle of phase voltage as shown in Fig.(2)The required signal for the control
system has two pulses for each period one when the comparator output changes from 0 to +V
and the other when it changes from +V to 0.. Comparing any two successive samples of
comparator output using XOR logic function will generate the pulses whenever the
comparator output changed as shown in Fig.(2). Comparator output is sampled using a single
bit register, and the register input and output are applied to XOR logic gate as shown in
Fig.(1). The AND gate and the inverter1) are used to disable the zero crossing pulse
generation whenever a global system reset is applied. Each phase has a separate zero-
crossing detector block to synchronize the saw-tooth
12
Equipment used :
1) Three power triacs (Part # BT139) has a 600V Repetitive peak off-state voltage and
16 A on-state current.
4) One dc power supplies +5/-5V to feed the comparators required for zero crossing.
7) Three step down transformers to feed the phase voltages to the three comparators
8)three op amps
9) Group of wires
Programs used :
2) Psim version 5
13
14
he design of the circuit using the pcp exxpress :
*Th
15
Simulation of the Circuit Using Psim Program :
16
*Computer Simulation:
The figure above is designed by using the PSIM (5) , it is content of three phase supply
Feeding three phase induction motor active as load , the name plate for the induction
Motor is
1 kW, 380 V, star connections, 3.0A, 4-pole, 60 Hz, Rs = 0.0583 pu, pu, X s = 0.125pu,
R r = 0 .0417
The simulation designed and used to show and calculate different operation to study
Variation between the different parameter the figures next how the different variation
**the variation of the thee phase current under induction motor load with different has
Only show three type of modes (0\2 & 0\2\3 & 2\3) with different values of α (degree)
That is mean only two of the current will operate while the third off or the all three
current will operate to gathers
17
*the second mode is even no current flow or tow current flow or three current
flow(0\2\3)
18
speed (pu)vs α
1.2
0.8
0.6
0.4
0.2
0
0 10 20 30 40 50 60 70 80 90
pf vsα
0.6
0.5
0.4
0.3
pf vsα
0.2
0.1
0
0 20 40 60 80 100
19
phase voltage vs α
1.2
0.8
0.6
phase voltage vs α
0.4
0.2
0
0 20 40 60 80 100
THD vs α
120
100
80
60
THD vs α
40
20
0
0 20 40 60 80 100
20
η vsα
100
90
80
70
60
50
η vsα
40
30
20
10
0
0 20 40 60 80 100 120
PF vS SPEED
0.8
0.7
0.6
0.5
0.4
PF vS SPEED
0.3
0.2
0.1
0
0 0.2 0.4 0.6 0.8 1 1.2
21
η VS SPEED
90
80
70
60
50
40
30
20
10
0
0 0.2 0.4 0.6 0.8 1 1.2
Conclusions:
Three-phase ac voltage controller has been used to start and control the speed of induction
motor by controlling the stator voltage. Computer simulation using PSIM a software has
been carried out to configure the performance of the motor in each mode. From simulation
results there are three modes of operations depending on the shape of supply currents. These
modes namely 0/2 , 0/2/3, and 2/3. The variation of speed with firing angle is different in
each mode. The control system detects the mode of operation to provide the switches with
the correct firing angle. The operating limits have been determined from the simulation
results using PSIM computer program.
22
Content:
topic Page number
Abstract 1
Introduction 2
Equipment used 13
Program used 14
Result 19
References 23
23
References :
[6] Morters et. al. "Control system for regulating the speed of an
electric motor" U.S. Patent 4093898, June 1978.
24