Meditec Neptune PLUS

“People you can Trust” Anaesthesia Workstation

Precision and
Performance Redefined
in Anesthesia Care
We recognize the demands and requirements of the Anaesthetist in the Operating Theatre and have taken these into
consideration when developing the all-new NeptunePLUS Anaesthesia Workstation. The NeptunePLUS excels in
performance and offers complete flexibility to the Anaesthetist

Advanced Technology, Modular Design, Open Architecture, Ease of Use


With an integrated design and excellent quality, each anaesthesia system is custom built to meet your requirements.
· Cascaded 6 tube flow meter · Common gas outlet (CGO)
· Twin Selectatec mounting for agent specific temperature · Suitable for open, semi-open & closed circuit system
and pressure compensated vaporisers application
· NIST inlets for piped medical gases for O2, N2O & Air as · Electrical outlets for running other medical equipment
standard · Auxiliary O2 outlet with flowmeter as standard
· Single Bi-stable system ON / OFF switch for gases & power · Rotameter backlit illumination
supply
· Work surface lighting
· Secure Pull-Out Writing Table with Raised Edges
· Supports Low-Flow Anaesthesia
· Open/Close change over switch for convenient switch-over
from open to closed system · Ventilatory parameters trends of 72 Hours

Optional Features
· 10.1" display electronic gas mixing screen · Side arm for patient monitor
- Electronic Hypxia guard that maintains minimum 25% · Basal flow for oxygen
of O2 digitally · Electronic gas mixing with virtual flowmeter
- Virtual flowmeters for O2, N2O and Air
· Anaesthetic gas with MAC value and N2O monitoring
- Custom Presets
- Digital basal flow with an option for activation and · EtCO2 monitoring
deactivation · Air / N2O interlock
- Digital display of pipeline pressures · Event log up to 1000 events
· Aspirator suction (Gas Powered) · Waveform freeze
· AGSS system (Active or Passive) · Ventilator driving gas - Medical Air
· One additional pin indexed yokes for O2 /N2O

Mechanical Flowmeter Separate electronic flowmeter


(Standard) with 10.1 inches display (optional)

Vaporiser (Optional)
Calibration range : 0 to 5%, 0 to 6% and 0 to 8% using a Laser Refractometer
Easy to turn dials for Safety Lock to prevent accidental turn on
Agent specific vaporisers designed to provide constant output
Interlock mechanism to lock in series with other Vaporisers
Individually calibrated for each specific anesthetic drug
Meditec ME-SORBTM
Agent Capacity: 250±25ml
CO2 absorbent is
Available in Screw fill, Quik Fil™ and Meditec Fill™ recommended for use with
Available for Halothane, Isoflurane, Sevoflurane, Desflurane Allied Meditec Neptune Plus.
*Quik Fil® is a registered trademark of Abbott Laboratories.
Integrated Ventilator
An integrated microprocessor-based ventilator, pneumatically driven and electronically controlled, combining simplicity with
the advanced features of modern ventilators. Designed for optimal patient care, it includes a built-in battery backup for
uninterrupted operation during power failures.

Features
· High-luminance and wide display · HLM: Heart Lung Machine mode
· 12.1” capacitive touch screen with encoder knob · Integrated CO2 and Anaesthetic agent with MAC
monitoring (optional)
· Ventilation Modes : V-CMV, P-CMV, V-SIMV, P-SIMV,
CPAP/PSV, Manual/SPONT and PCV-VG · Self test, leak test and compliance test
· Comprehensive parameter monitoring featuring more · Adult, pediatric and neonatal mode
than 20 measured values
· Waveforms: Flow-Time, Volume-Time, Pressure-Time
· Multiple Screen layouts
· Spirometry Loops: Flow-Volume, Volume-Pressure,
· Volume compensation and electronic PEEP. Pressure-Flow
Automatically compensates for system leak and the
· Setting Parameters
compliance change in the circuit
VT (Tidal Volume), Frequency, I:E ratio, Tip (Inspiratory
· Fresh gas flow compensation pause time), Pmax, PEEP, SIGH, PLimit, Psupp.,
Trigger: Flow and Pressure Triggers Settings
· Ascending bellows provides immediate visual
information on the adequacy of fresh gas flow and · Alarm Parameters
gives an indication of any system leak Sustained pressure, Airway pressure (high & low),
FiO2 (high & low), MV (high & low), Frequency (high &
low), Apnea, A/C failure, Battery low, Self-test failure,
O2 failure alarm

Integrated Circle Breathing System


· Bypass allows canister change during ventilation · Fully calibrated APL valve (Range 0-70 cmH2O)
· Bag/ventilator switch - Easy changeover from · Built-in oxygen monitor sensor port
ventilator to bag & vice versa
· Automatic ventilator switching from circle absorber
· Integrated airway pressure manometer
· Autoclavable
· Moisture drain valve
· Heated breathing module to prevent moisture
· Quick release sodalime canister system buildup

Patient Monitoring (Optional)


The Neptune range offers a wide choice of Monitoring Systems with availability of optional extended parameters
such as AGM, BIS, ICG, CO, 4 x IBP, EEG, Para-magnetic O2, NMT

ECG | NIBP | SpO2 | 2xTEMP | RESP | EtCO2 | AGM | CO | IBP | BIS | NMT | ICG | EEG
TECHNICAL SPECIFICATIONS
Storage Space Two spacious drawers to hold essential anaesthesia kit and accessories
Castors Large roller bearing anti-static castors with front brakes
Writing Surface Pull out writing table on top of the drawers
Monitor Shelf Wide monitor shelf at eye level with securing provision for extra monitor
Cylinder Yokes Color coded gas specific (pin indexed) yokes with sliding stainless steel clamping bars for easy
handling. Holding 1 (One) for O2 and 1 (One) for N2O, 5 Ltr. water capacity cylinder
Non-return / Minimises risk of back flow of gases, blows off when pressure exceeds 125 CmH2O (customisable)
Pressure Relief Valve
Regulators Designed for higher efficiency, long service life and reliability for O2 and N2O
Oxygen Flush Oxygen flush switch at table level to give 25–75 Ltrs/min for emergencies
O2 Failure Warning Alarm Self activated electro-pneumatic audio visual warning device to indicate drop in O2 pressure below 2.5 Bar
Hypoxic Guard (Mechanical) Mixing device to proportion the N2O in such a way that minimum of 25% O2 is always delivered in the
gas mixture
Common Gas Outlet (CGO) Conveniently located CGO with ISO tapers for 22 & 15mm connections
Basal flow with On/off Switch 250 ± 50 ml basal flow of Oxygen as soon as machine is switched on (optional)
Pipe Line Gas Inlets Non-Interchangeable Screw Threaded (NIST) pipeline inlets one each for O2, N2O and Air. In case of
drop in piped gas pressure the pin index cylinders take over automatically
Pressure Gauges Large diameter, color coded gauges fitted at convenient angle for better visibility and clarity. One for
each of the pin indexed yokes and one each corresponding to piped gas inlet
Selectatec Brackets Twin Selectatec Block
Communication port RS232, LAN, USB and Upgradable with Anaesthesia electronic charting system

CASCADE FLOWMETER VENTILATOR TECHNICAL PARAMETERS


Oxygen Flow 0.05–1 Lpm (Low) 1–10 Lpm (High) Tidal Volume 10–1600 ml
N2O Flow 0.05–1 Lpm (Low ) 1–12 Lpm (High) Frequency 1–100 bpm
Air Flow 0.05–1 Lpm (Low) 1–15 Lpm (High) I : E Ratio 4:1–1:10
PEEP OFF, 1.0–30 cmH2O
ELECTRONIC FLOWMETER (Optional) Patient Flow Trigger 0–15 lpm
O2 Concentration 21-100% (O2 / Air) Patient Pressure Trigger 0 to (-)20 cmH2O
25-100% (O2 / N2O) Alarm Mute 120s
Total Flow Range 0-15 Lpm Compliance <4ml/100Pa
Accuracy ±5% (total flow) Inspiratory Pause 0–60% of Ti
Basal Flow 0.2 Lpm Flow <180L/min
Fresh Gas Mixture O2+Air / O2 +N2O Pressure Limiting (Pmax) 5–100 cmH2O
Pipeline Pressure Digital display Drive Gas Oxygen (Standard) / Air (Optional)
Alarms O2, N2O & Air failure Drive Mode Pneumatically driven
electronically controlled
PHYSICAL SPECIFICATION Power 100–240vAC, 50/60Hz, 6.5A (Max.)
Dimensions (H x W x D) 1430 x 760 × 720 mm Power Consumption 110W
Top Shelf 560 mm × 370 mm Battery Backup on Ventilator 120 minutes
Work Surface 560 mm × 120 mm Temperature Operation: 10°C–40°C
Storage : (-)20°C–55°C
Drawer 2 Drawers - 460 mm × 430 mm
Humidity Operation : <80%
Weight 95 kg Storage : <93%

Manufactured in India by
Allied Medical Limited
76-77, Udyog Vihar, Phase IV,
Gurugram - 122 015, Haryana, INDIA
E-mail : sales@alliedmed.co.in
MEDICAL Website : www.alliedmed.co.in
Design & Technology Partner

Meditec International England Limited


*In view of continued product improvement Allied Medical Limited reserves the right to make changes in the equipment which may affect the information contained in this leaflet without giving any
prior notice. Pictures are representative, accessories are optional and may vary at the time of supply. Meditec England is the registered trademark of Meditec International England Limited.

You might also like