FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES

118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

CERTIFICATE OF ACCREDITATION
(AS PER ISO/IEC 17025:2017)

This is to attest that

M/s MODTECH CREATIVE LABS PVT. LTD.


Plot No.-3802, Laxman Vihar-II, Gurgaon-122001, Haryana, India

Calibration Laboratory
has demonstrated compliance with ISO/IEC Standard 17025:2017, General requirements for
the competence of testing and calibration laboratories and supplementary criteria for
calibration laboratories.

Certificate Number: CL-117

Issue Date: 09.01.2024 Valid Until: 08.01.2026

The certificate remains valid for the Scope of Accreditation as specified in the annexure
subject to continued satisfactory compliance to the above standard and the relevant
requirements of FDAS. (for scope of accreditation visit website www. fdasindia.org).
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)
Validity 09.01.2024 to 08.01.2026 Amended on N/A
Electro-Technical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Alternating Current (Measure Mode)

1 AC Current Digital Multimeter (6½ Digits) 30 µA to 3 A 0.44 % to 0.28 %


@ 50 Hz to 10 kHz by Direct/ Comparison
Method
2 AC Current Digital Multimeter (6½ Digits) 3 A to 10 A 0.28 % to 0.25 %
@ 50 Hz to 5 kHz by Direct/ Comparison
Method
3 AC Current Energy Data Logger by 10 A to 1000 A 2.1 % to 1.8 %
@ 50 Hz Direct Method
4 AC Voltage Digital Multimeter (6½ Digits) 100 V to 1000 V 0.14 % to 0.13 %
@ 50 Hz to 1 kHz by Direct Method
5 AC Voltage Digital Multimeter (6½ Digits) 10 mV to 100 V 0.6 % to 0.14 %
@ 50 Hz to 10 kHz by Direct Method
6 Active Power (220 V Energy Data Logger by 0.22 kW to 12 kW 2 % to 1 %
to 600 V, 1 A to 20 Direct Method
A, ±0.5 to
UPF,50Hz)
7 Capacitance @1 Digital Multimeter (6½ Digits) 1 nF to 100 µF 2.5 % to 2 %
kHz by Direct/ Comparison
Method
8 Energy(Single/Three 3 Phase Energy Meter by 1 kWh to 5 kWh 0.5%
Phase) 240V/ 1A to Direct/Comparison Method
5A/ 0.5 to UPF
9 Power Factor Energy Data Logger by ±0.2 to UPF 0.009 PF
Direct Method
Alternating Current (Source Mode)

1 AC Current @50 Hz Multi-Product Calibrator & 20 A to 1000 A 1.3 % to 0.7 %


Current Coil by Direct
Method
2 AC Current @50 Hz Multi-Product Calibrator by 30 µA to 3 mA 0.6 % to 0.14 %
to 1 kHz Direct Method
3 AC Current @50 Hz Multi-Product Calibrator by 3 mA to 3 A 0.14 % to 0.15 %
to 10 kHz Direct Method
4 AC Current @50 Hz Multi-Product Calibrator by 3 A to 20 A 0.15 % to 0.18 %
to 5 kHz Direct Method

Dealing Officer
Page 1 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (Laboratory based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

5 AC Voltage @50Hz Multi-Product Calibrator by 100 mV to 1000 V 0.12 % to 0.08 %


to 10kHz Direct Method
6 AC Voltage @50Hz Multi-Product Calibrator by 1 mV to 100 mV 2.7 % to 0.12 %
to 1kHz Direct Method
7 Active Power (120 V Multi-Product Calibrator by 2.4 W to 4.8 kW 0.63 % to 0.3 %
to 240 V / 0.1 A to Direct Method
20 A) @ 50 Hz &
±0.2 PF to UPF
8 Capacitance @1 Multi-Product Calibrator by 220 pF to 110 mF 2.5 % to 1.46 %
kHz Direct Method
9 Inductance @1 kHz Decade Inductance Box by 100 µH to 10 H 1.5 % to 1.6 %
direct method
10 Power Factor Multi-Product Calibrator by ±0.2 PF to UPF 0.001 PF
Direct Method
Direct Current (Measure Mode)

1 DC Current Shunt & Digital Multimeter 10 A to 1000 A 2.3 % to 2.2 %


(6½ Digits) by Direct Method
2 DC Current Digital Multimeter (6½ Digits) 100 mA to 10 A 0.15 % to 0.95 %
by Direct/ Comparison
Method
3 DC Current Digital Multimeter (6½ Digits) 30 µA to 100 mA 0.58 % to 0.15 %
by Direct/ Comparison
Method
4 DC Voltage Digital Multimeter (6½ Digits) 1 mV to 100 mV 0.46 % to 0.06 %
by Direct/ Comparison
Method

5 DC Voltage Digital Multimeter (6½ Digits) 100 mV to 1000 V 0.06 % to 0.1 %


by Direct/ Comparison
Method

6 Resistance (4 Wire) Digital Multimeter (6½ Digits) 1 Ω to 100 Ω 0.36 % to 0.05 %


by Direct/ Comparison
Method

7 Resistance (2 Wire) Digital Multimeter (6½ Digits) 100 Ω to 1000 0.05 % to 2.5 %
by Direct/ Comparison MΩ
Method

Dealing Officer
Page 2 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (Laboratory based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Direct Current (Source Mode)

1 DC Current Multi-Product Calibrator & 20 A to 1000 A 1.35 % to 1.2 %


Current Coil by Direct
Method

2 DC Current Multi-Product Calibrator by 3 A to 20 A 0.2 % to 0.33 %


Direct Method

3 DC Current Multi-Product Calibrator by 30 µA to 3 A 0.3 % to 0.2 %


Direct Method

4 DC Power (1 V to Multi-Product Calibrator by 1 mW to 20 kW 0.63 % to 0.3 %


1000 V, 1 mA to 20 Direct Method
A)

5 DC Resistance (4 Multi-Product Calibrator/ 1 Ω to 3 MΩ 1.17 % to 0.03 %


Wire & 2 Wire) Decade Resistance Box by
Direct Method

6 DC Resistance (2 Multi-Product Calibrator/ 3 MΩ to 300 MΩ 0.03 % to 0.63 %


Wire) Decade Resistance Box by
Direct Method

7 DC Resistance (2 Multi-Product Calibrator/ 300 MΩ to 1000 0.63 % to 1.79 %


Wire) Decade Resistance Box by MΩ
Direct Method

8 DC Resistance (2 Standard Resistance Box by 1,10,100,200,500, 3.1%


Wire) direct method 1000 GΩ

9 DC Resistance (4 Standard Resistance Box by 0.1, 1, 10, 100 2.5%


Wire) Direct Method mΩ

Dealing Officer
Page 3 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (Laboratory based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

10 DC Voltage Multi-Product Calibrator by 1 mV to 1000 V 0.36 % to 0.007 %


Direct Method

Electrical Equipment
1 Oscilloscope - Multi-Product Calibrator by 50 kHz to 300 1 % to 2 %
Bandwidth Direct Method MHz

2 Oscilloscope - Multi-Product Calibrator by 2 ns to 5 s 0.3 % to 0.7 %


Horizontal Direct Method
Deflection (Time
Marker)
3 Oscilloscope - Multi-Product Calibrator by 5 mV to 100 V 2.65 % to 0.7 %
Vertical Deflection Direct Method
(Amplitude)-AC

4 Oscilloscope - Multi-Product Calibrator by 1 mV to 33 V 0.5 % to 0.3 %


Vertical Deflection Direct Method
(Amplitude)-DC

Simulation (Measure Mode)


1 Temperature Multi-Product Calibrator/ 600 °C to 1800 °C 0.2°C
Indicator/ Controller/ Digital Multimeter (6½ Digits)
Data Logger/ by Simulation Method
Recorder /
Calibrator made for -
B Type
Thermocouple
2 Temperature Multi-Product Calibrator/ -200 °C to 1200 0.2°C
Indicator/ Controller/ Digital Multimeter (6½ Digits) °C
Data Logger/ by Simulation Method
Recorder /
Calibrator made for -
J Type
Thermocouple

Dealing Officer
Page 4 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (Laboratory based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

3 Temperature Multi-Product Calibrator/ -200 °C to 1370 0.3°C


Indicator/ Controller/ Digital Multimeter (6½ Digits) °C
Data Logger/ by Simulation Method
Recorder /
Calibrator made for -
K Type
Thermocouple
4 Temperature Multi-Product Calibrator/ -200 °C to 1300 0.5°C
Indicator/ Controller/ Digital Multimeter (6½ Digits) °C
Data Logger/ by Simulation Method
Recorder /
Calibrator made for -
N Type
Thermocouple
5 Temperature Multi-Product Calibrator/ 0 to 1750 °C 0.5°C
Indicator/ Controller/ Digital Multimeter (6½ Digits)
Data Logger/ by Simulation Method
Recorder /
Calibrator made for -
R Type
Thermocouple
6 Temperature Digital Multimeter (6½ Digits) -200 °C to 800 °C 0.12°C
Indicator/ Controller/ by Simulation Method
Data Logger/
Recorder /
Calibrator made for -
RTD
7 Temperature Multi-Product Calibrator/ 0 to 1750 °C 0.5°C
Indicator/ Controller/ Digital Multimeter (6½ Digits)
Data Logger/ by Simulation Method
Recorder /
Calibrator made for -
S Type
Thermocouple
8 Temperature Multi-Product Calibrator/ -200 °C to 400 °C 0.2°C
Indicator/ Controller/ Digital Multimeter (6½ Digits)
Data Logger/ by Simulation Method
Recorder /
Calibrator made for -

Dealing Officer
Page 5 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (Laboratory based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

T Type
Thermocouple

Simulation (Source Mode)


1 Temperature Multi-Product Calibrator/ 600 °C to 1800 °C 0.6°C
Indicator/ Controller/ Universal Calibrator by
Data Logger/ Simulation Method
Recorder /
Calibrator made for -
B Type
Thermocouple
2 Temperature Multi-Product Calibrator/ -200 °C to 1200 0.3°C
Indicator/ Controller/ Universal Calibrator by °C
Data Logger/ Simulation Method
Recorder /
Calibrator made for -
J Type
Thermocouple
3 Temperature Multi-Product Calibrator/ -200 °C to 1370 0.3°C
Indicator/ Controller/ Universal Calibrator by °C
Data Logger/ Simulation Method
Recorder /
Calibrator made for -
K Type
Thermocouple
4 Temperature Multi-Product Calibrator/ -200 °C to 1300 ° 0.4°C
Indicator/ Controller/ Universal Calibrator by
Data Logger/ Simulation Method
Recorder /
Calibrator made for -
N Type
Thermocouple
5 Temperature Multi-Product Calibrator/ 0 °C to 1750 °C 1°C
Indicator/ Controller/ Universal Calibrator by
Data Logger/ Simulation Method
Recorder /
Calibrator made for -

Dealing Officer
Page 6 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (Laboratory based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

R Type
Thermocouple

6 Temperature Multi-Product Calibrator/ -200 °C to 800 °C 0.3°C


Indicator/ Controller/ Universal Calibrator by
Data Logger/ Simulation Method
Recorder /
Calibrator made for -
RTD
7 Temperature Multi-Product Calibrator/ 0 °C to 1750 °C 1°C
Indicator/ Controller/ Universal Calibrator by
Data Logger/ Simulation Method
Recorder /
Calibrator made for -
S Type
Thermocouple
8 Temperature Multi-Product Calibrator/ -200 °C to 400 °C 0.73°C
Indicator/ Controller/ Universal Calibrator by
Data Logger/ Simulation Method
Recorder /
Calibrator made for -
T Type
Thermocouple
9 pH Meter(without Multi-Product Calibrator/ 0 to 14 pH 0.01 pH
electrode) Universal Calibrator by
Simulation Method

10 TDS Meter(without Multi-Product Calibrator/ 0 to 2000 ppm 0.50%


electrode) Resistance Box by
Simulation Method

11 Conductivity Multi-Product Calibrator/ 0.5 µS/cm to 0.50%


Meter(without Resistance Box by 1000 mS/cm
electrode) Simulation Method

Low Frequency (Measure Mode)

Dealing Officer
Page 7 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (Laboratory based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

1 Frequency Digital Multimeter (6½ Digits) 10 Hz to 1000 0.61 % to 0.06 %


by Direct Method kHz

2 Timer, Time Digital Time Calibrator by 1 s to 86400 s 0.01 s to 2.6 s


Calibrator, Hour Comparison Method
Meter, Stop Watch,
Time Interval Meter
Low Frequency (Source Mode)
1 Frequency Multi-Product Calibrator by 10 Hz to 100 kHz 0.2 % to 0.08 %
Direct Method

Dealing Officer
Page 8 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Alternating Current (Measure Mode)


1 AC Current Digital Multimeter (6½ 30 µA to 3 A 0.44 % to 0.28 %
@ 50 Hz to 10 kHz Digits) by Direct/
Comparison Method

2 AC Current Digital Multimeter (6½ 3 A to 10 A 0.28 % to 0.25 %


@ 50 Hz to 5 kHz Digits) by Direct/
Comparison Method

3 AC Current Energy Data Logger by 10 A to 1000 A 2.1 % to 1.8 %


@ 50 Hz Direct Method

4 AC Voltage Digital Multimeter (6½ 100 V to 1000 V 0.14 % to 0.13 %


@ 50 Hz to 1 kHz Digits) by Direct Method

5 AC Voltage Digital Multimeter (6½ 10 mV to 100 V 0.6 % to 0.14 %


@ 50 Hz to 10 kHz Digits) by Direct Method

6 Active Power (220 Energy Data Logger by 0.22 kW to 12 kW 2 % to 1 %


V to 600 V, 1 A to Direct Method
20
A, ±0.5 to UPF, 50
Hz)
7 Capacitance @1 Digital Multimeter (6½ 1 nF to 100 µF 2.5 % to 2 %
kHz Digits) by Direct/
Comparison Method

8 Energy 3 Phase Energy Meter by 1 kWh to 5 kWh 0.5%


(Single/Three Direct/Comparison Method
Phase) 240V/ 1A
to 5A/ 0.5 to UPF
9 Power Factor Energy Data Logger by ±0.2 to UPF 0.009 PF
Direct Method

Dealing Officer
Page 9 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

10 AC High Voltage HV Probe & Digital 1 kV to 20 kV 4%


@ 50Hz Multimeter by Direct
Method

Alternating Current (Source Mode)


1 AC Current @50 Multi-Product Calibrator & 20 A to 1000 A 1.3 % to 0.7 %
Hz Current Coil by Direct
Method

2 AC Current @50 Multi-Product Calibrator by 30 µA to 3 mA 0.6 % to 0.14 %


Hz to 1 kHz Direct Method

3 AC Current @50 Multi-Product Calibrator by 3 mA to 3 A 0.14 % to 0.15 %


Hz to 10 kHz Direct Method

4 AC Current @50 Multi-Product Calibrator by 3 A to 20 A 0.15 % to 0.18 %


Hz to 5 kHz Direct Method

5 AC Voltage Multi-Product Calibrator by 100 mV to 1000 V 0.12 % to 0.08 %


@50Hz to 10kHz Direct Method

6 AC Voltage Multi-Product Calibrator by 1 mV to 100 mV 2.7 % to 0.12 %


@50Hz to 1kHz Direct Method

7 Active Power (120 Multi-Product Calibrator by 2.4 W to 4.8 kW 0.63 % to 0.3 %


V to 240 V / 0.1 A Direct Method
to 20 A) @ 50 Hz &
±0.2 PF to UPF
8 Capacitance @1 Multi-Product Calibrator by 220 pF to 110 mF 2.5 % to 1.46 %
kHz Direct Method

Dealing Officer
Page 10 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

9 Inductance @1 Decade Inductance Box by 100 µH to 10 H 1.5 % to 1.6 %


kHz direct method

10 Power Factor Multi-Product Calibrator by ±0.2 PF to UPF 0.001 PF


Direct Method

Direct Current (Measure Mode)

1 DC Current Shunt & Digital Multimeter 10 A to 1000 A 2.3 % to 2.2 %


(6½ Digits) by Direct
Method

2 DC Current Digital Multimeter (6½ 100 mA to 10 A 0.15 % to 0.95 %


Digits) by Direct/
Comparison Method

3 DC Current Digital Multimeter (6½ 30 µA to 100 mA 0.58 % to 0.15 %


Digits) by Direct/
Comparison Method

4 DC Voltage Digital Multimeter (6½ 1 mV to 100 mV 0.46 % to 0.06 %


Digits) by Direct/
Comparison Method

5 DC Voltage Digital Multimeter (6½ 100 mV to 1000 V 0.06 % to 0.1 %


Digits) by Direct/
Comparison Method

6 Resistance (4 Digital Multimeter (6½ 1 Ω to 100 Ω 0.36 % to 0.05 %


Wire) Digits) by Direct/
Comparison Method

7 Resistance (2 Digital Multimeter (6½ 100 Ω to 1000 MΩ 0.05 % to 2.5 %


Wire) Digits) by Direct/
Comparison Method

Dealing Officer
Page 11 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

8 DC High Voltage HV Probe & Digital 1 kV to 20 kV 4%


Multimeter by Direct
Method

Direct Current (Source Mode)

1 DC Current Multi-Product Calibrator & 20 A to 1000 A 1.35 % to 1.2 %


Current Coil by Direct
Method

2 DC Current Multi-Product Calibrator by 3 A to 20 A 0.2 % to 0.33 %


Direct Method

3 DC Current Multi-Product Calibrator by 30 µA to 3 A 0.3 % to 0.2 %


Direct Method

4 DC Power (1 V to Multi-Product Calibrator by 1 mW to 20 kW 0.63 % to 0.3 %


1000 V, 1 mA to 20 Direct Method
A)

5 DC Resistance (4 Multi-Product Calibrator/ 1 Ω to 3 MΩ 1.17 % to 0.03 %


Wire & 2 Wire) Decade Resistance Box by
Direct Method

6 DC Resistance (2 Multi-Product Calibrator/ 3 MΩ to 300 MΩ 0.03 % to 0.63 %


Wire) Decade Resistance Box by
Direct Method

7 DC Resistance (2 Multi-Product Calibrator/ 300 MΩ to 1000 MΩ 0.63 % to 1.79 %


Wire) Decade Resistance Box by
Direct Method

8 DC Resistance (2 Standard Resistance Box 1,10,100,200,500,1000 3.1%


Wire) by direct method GΩ

Dealing Officer
Page 12 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

9 DC Resistance (4 Standard Resistance Box 0.1, 1, 10, 100 mΩ 2.5%


Wire) by Direct Method

10 DC Voltage Multi-Product Calibrator by 1 mV to 1000 V 0.36 % to 0.007 %


Direct Method

Electrical Equipment

1 Oscilloscope - Multi-Product Calibrator by 50 kHz to 300 MHz 1 % to 2 %


Bandwidth Direct Method

2 Oscilloscope - Multi-Product Calibrator by 2 ns to 5 s 0.3 % to 0.7 %


Horizontal Direct Method
Deflection (Time
Marker)
3 Oscilloscope - Multi-Product Calibrator by 5 mV to 100 V 2.65 % to 0.7 %
Vertical Deflection Direct Method
(Amplitude)-AC

4 Oscilloscope - Multi-Product Calibrator by 1 mV to 33 V 0.5 % to 0.3 %


Vertical Deflection Direct Method
(Amplitude)-DC

Simulation (Measure Mode)


1 Temperature Multi-Product Calibrator/ 600 °C to 1800 °C 0.2°C
Indicator/ Digital Multimeter (6½
Controller/ Data Digits) by Simulation
Logger/ Recorder / Method
Calibrator made for
-B Type
Thermocouple
2 Temperature Multi-Product Calibrator/ -200 °C to 1200 °C 0.2°C
Indicator/ Digital Multimeter (6½
Controller/ Data Digits) by Simulation
Logger/ Recorder / Method

Dealing Officer
Page 13 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Calibrator made for


-J Type
Thermocouple

3 Temperature Multi-Product Calibrator/ -200 °C to 1370 °C 0.3°C


Indicator/ Digital Multimeter (6½
Controller/ Data Digits) by Simulation
Logger/ Recorder / Method
Calibrator made for
-K Type
Thermocouple
4 Temperature Multi-Product Calibrator/ -200 °C to 1300 °C 0.5°C
Indicator/ Digital Multimeter (6½
Controller/ Data Digits) by Simulation
Logger/ Recorder / Method
Calibrator made for
-N Type
Thermocouple
5 Temperature Multi-Product Calibrator/ 0 to 1750 °C 0.5°C
Indicator/ Digital Multimeter (6½
Controller/ Data Digits) by Simulation
Logger/ Recorder / Method
Calibrator made for
-R Type
Thermocouple
6 Temperature Digital Multimeter (6½ -200 °C to 800 °C 0.12°C
Indicator/ Digits) by Simulation
Controller/ Data Method
Logger/ Recorder /
Calibrator made for
-RTD
7 Temperature Multi-Product Calibrator/ 0 to 1750 °C 0.5°C
Indicator/ Digital Multimeter (6½
Controller/ Data Digits) by Simulation
Logger/ Recorder / Method
Calibrator made for
-S Type
Thermocouple

Dealing Officer
Page 14 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

8 Temperature Multi-Product Calibrator/ -200 °C to 400 °C 0.2°C


Indicator/ Digital Multimeter (6½
Controller/ Data Digits) by Simulation
Logger/ Recorder / Method
Calibrator made for
-T Type
Thermocouple
Simulation (Source Mode)
1 Temperature Multi-Product Calibrator/ 600 °C to 1800 °C 0.6°C
Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-B Type
Thermocouple
2 Temperature Multi-Product Calibrator/ -200 °C to 1200 °C 0.3°C
Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-J Type
Thermocouple
3 Temperature Multi-Product Calibrator/ -200 °C to 1370 °C 0.3°C
Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-K Type
Thermocouple
4 Temperature Multi-Product Calibrator/ -200 °C to 1300 ° 0.4°C
Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-N Type
Thermocouple

Dealing Officer
Page 15 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

5 Temperature Multi-Product Calibrator/ 0 °C to 1750 °C 1°C


Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-R Type
Thermocouple
6 Temperature Multi-Product Calibrator/ -200 °C to 800 °C 0.3°C
Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-RTD
7 Temperature Multi-Product Calibrator/ 0 °C to 1750 °C 1°C
Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-S Type
Thermocouple
8 Temperature Multi-Product Calibrator/ -200 °C to 400 °C 0.73°C
Indicator/ Universal Calibrator by
Controller/ Data Simulation Method
Logger/ Recorder /
Calibrator made for
-T Type
Thermocouple
9 pH Meter (without Multi-Product Calibrator/ 0 to 14 pH 0.01 pH
sensor) Universal Calibrator by
Simulation Method

10 TDS Meter (without Multi-Product Calibrator/ 0 to 2000 ppm 0.50%


sensor) Resistance Box by
Simulation Method

11 Conductivity Meter Multi-Product Calibrator/ 0.5 µS/cm to 1000 0.50%


(without sensor) Resistance Box by mS/cm
Simulation Method

Dealing Officer
Page 16 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Electro-Technical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Low Frequency (Measure Mode)

1 Frequency Digital Multimeter (6½ 10 Hz to 1000 kHz 0.61 % to 0.06 %


Digits) by Direct Method

2 Timer, Time Digital Time Calibrator by 1 s to 86400 s 0.01 s to 2.6 s


Calibrator, Hour Comparison Method
Meter, Stop Watch,
Time Interval Meter
Low Frequency (Source Mode)
1 Frequency Multi-Product Calibrator by 10 Hz to 100 kHz 0.2 % to 0.08 %
Direct Method

Dealing Officer
Page 17 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Acceleration & Speed

1 Tachometer / RPM Tachometer & RPM Source 10 rpm to 6000 4 % to 0.1 %


Meter - Contact Mode (SANASTR45-II-2017) rpm

2 Tachometer / RPM Tachometer & RPM Source 10 rpm to 99000 4 % to 0.1 %


Meter - Non- Contact (SANASTR45-II-2017) rpm
Mode

3 Tachometer Calibrator Tachometer (SANASTR45- 10 rpm to 99000 4 % to 0.1 %


/ Stroboscope II-2017) rpm

4 Vibration - Portable Vibration 1 m/s² to 100 7 % to 4 %


Acceleration (10 Hz to Calibrator m/s²
300 Hz)

5 Vibration - Portable Vibration 0.01 mm to 2 7 % to 4 %


Displacement (10 Hz Calibrator mm
to 100 Hz)

6 Vibration -Velocity (10 Portable Vibration 12.5 mm/s to 7 % to 4 %


Hz to 500Hz) Calibrator 160 mm/s

Acoustics

1 Sound Level Meter @ Sound Level Calibrator 94 dB & 114 dB 0.5 dB


1 kHz

Dimension

1 Angle Graticule Profile Projector 0 ° to 360 ° 2'


L.C: 1 °

Dealing Officer
Page 18 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

2 Angle Plate/ Box Plate Lever Dial, Master 50 mm to 600 Squareness: 4µm
(Parallelism, Cylinder, Granite Square, mm Parallelism: 4µm
Squareness, Flatness) Slip Gauge Blocks Flatness: 4µm
(IS 6232 :1971 RA 2019, Symmetricity: 4µm
IS-2554: 1971 RA 2020,
IS-6973: 1973 RA 2020,
IS-6985: 1973 RA 2020)
3 Bevel Protractor LC:1' Angle Gauge Set 0 to 90 ° 2
(IS 4239: 2023)

4 Bore Gauge - Universal Length 0 to 2 mm 1.1µm


Transmission Measuring Machine, Dial
Calibration Tester,
Digimatic Indicator
(JIS B7515:1982)
5 Caliper LC: 0.01mm Slip Gauge Blocks, Caliper 0 to 300 mm 9µm
Checker
(IS 16491(part-1):2016
RA2021)
6 Caliper LC: 0.01mm Slip Gauge Blocks, Caliper 0 to 600 mm 12µm
Checker
(IS 16491(part-1):2016
RA2021)
7 Caliper LC:0.01mm Caliper Checker, Long 0 to 1000 mm 15µm
Gauge Blocks
(IS 16491(part-1):2016
RA2021)
8 Caliper LC:0.01 mm Caliper Checker, Long 0 to 2000 mm 30µm
Gauge Blocks
(IS 16491(part-1):2016
RA2021)
9 Coating Thickness Standard Foils 10 µm to 1000 1.5 µm to 3 µm
Gauge (Ferrous & (IS 12554 (Part 2):1999 RA µm
Non-Ferrous Type) 2013)

Dealing Officer
Page 19 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

10 Combination Set/ Angle Gauge Set 0 to 180 ° 0.6°


Angle Protractor LC:1°

11 Comparator Stand Lever Dial 50x50 mm to 3µm


- Flatness of Base (IS 12937:1990 RA 2020) 300x300 mm

12 Cube Mould Digital Caliper 50 mm to 300 0.043mm


(IS 10086:2021) mm

13 Depth Micrometer/ Slip Gauge Blocks 0 to 300 mm 8µm


Depth Gauge/ Depth (IS 16491(part-2):2016
Caliper LC:0.001mm RA2021)

14 Dial Snap Gauge/Dial Slip Gauge Blocks 0 to 100 mm 1.8µm


Snap Micrometer (IS-3455 (part 1):1985 RA
LC:0.001mm 2020)

15 Dial Thickness Gauge Slip Gauge Blocks & 0 to 100 mm 1.8µm


LC:0.001mm Thickness Foils

16 External Micrometer Slip Gauge Blocks, Optical 0 to 25 mm 0.5 µm


LC:0.0001 mm Parallel Set
(IS 2967: 1983 RA 2019 &
JIS B 7502:2016)
17 External Micrometer Slip Gauge Blocks, Slip 0 to 300 mm 1.8 µm
LC:0.001 mm Gauge Accessories,
Optical Parallel Set
(IS 2967: 1983 RA 2019 &
JIS B 7502:2016)
18 External Micrometer Slip Gauge Blocks, Slip 0 to 2000 mm 5 µm
LC:0.001 mm Gauge Accessories, Long
Gauge Block, Optical
Parallel Set
(IS 2967: 1983 RA 2019 &
JIS B 7502:2016)

Dealing Officer
Page 20 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

19 Eye Piece LC-0.1 mm Profile Projector 0 to 10 mm 0.01mm

20 Feeler Gauge/ Universal Length 0.01 mm to 2 1.2µm


Thickness Foils Measuring Machine mm
(IS – 3179:1990 RA
2020)
21 Flakiness Gauge Digital Caliper 4.7 mm to 100.5 0.02mm
(Thickness Gauge)/ (IS 2386 mm
Elongation Gauge (part 1):1963 RA 2021)
(Length Gauge)
22 Flush Pin Gauge Slip Gauge Blocks, Lever 5 mm to 100 2 µm
Dial mm

23 Gap Gauge/ Slit Universal Length 1 mm to 100 2.4µm


Gauge Measuring Machine mm

24 Gap Gauge/ Slit Universal Length 100 mm to 200 4µm


Gauge Measuring Machine mm

25 Hegman Gauge Digimatic Indicator 0 to 100 µm 2 µm

26 Height Gauge Slip Gauge Blocks, Caliper 0 to 1000 mm 15 µm


LC:0.01mm Checker, Long Gauge
Blocks
(IS 2921:2016 RA 2021)
27 Height Gauge Slip Gauge Blocks, Caliper 0 to 300 mm 8 µm
LC:0.01mm Checker
(IS 2921:2016 RA 2021)

28 Height Gauge Slip Gauge Blocks, Caliper 0 to 600 mm 12 µm


LC:0.01mm Checker
(IS 2921:2016 RA 2021)

Dealing Officer
Page 21 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

29 Height Master Slip Gauge Blocks, Long 0 to 310 mm 4µm


LC:0.001mm Gauge Blocks, Lever Dial

30 Height Master Slip Gauge Blocks, Long 0 to 610 mm 6µm


LC:0.001mm Gauge Blocks, Lever Dial

31 Inclinometer/ Digital Angle Gauge Set 0 ° to 360 ° 3


Angle Protractor
(Meter) L.C: 0.01 °

32 Inside Caliper Gauge/ Slip Gauge Blocks 0 to 100 mm 1.8µm


Inside Pistol Caliper
LC:0.001mm

33 Internal Micrometer (2 Slip Gauge Blocks, Long 2 mm to 300 3µm


Points) LC:0.001mm Gauge Blocks & mm
Accessories
(IS 2966: 1964 RA 2019)
34 Internal Micrometer (2 Slip Gauge Blocks, 300 mm to 2000 20µm
Points) LC:0.001mm Accessories & Long Gauge mm
Blocks
(IS 2966: 1964 RA 2019)
35 Internal Micrometer/ Standard Ring Gauge Set 6 mm to 100 3µm
Bore Micrometer (3 mm
Points) LC:0.001mm

36 Length Bar/ Slip Gauge Blocks, Long 1 mm to 300 4µm


Micrometer Setting Gauge Blocks, Lever Dial mm
Rod / Riser Block/ (IS 7014: 1973 RA-2020)
Height Setting Master/
Micrometer Extension
Rod
37 Length Bar/ Slip Gauge Blocks, Long 300 mm to 600 5µm
Micrometer Setting Gauge Blocks, Lever Dial mm
Rod / Riser Block/ (IS 7014: 1973 RA-2020)
Height Setting Master/
Micrometer Extension
Rod

Dealing Officer
Page 22 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

38 Length Bar/ Slip Gauge Blocks, Long 600 mm to 1975 7 µm


Micrometer Setting Gauge Blocks, Lever Dial mm
Rod / Riser Block/ (IS 7014: 1973 RA-2020)
Height Setting Master/
Micrometer Extension
Rod
39 Lever Dial (Puppy Dial) Universal Length 0 to 0.2 mm 1µm
LC:0.001mm Measuring Machine, Dial
Calibration Tester
(IS 11498:1985 RA 2000)
40 Lever Dial (Puppy Dial) Universal Length 0 to 1.6 mm 2.5µm
LC:0.01mm Measuring Machine, Dial
Calibration Tester
(IS 11498:1985 RA 2000)
41 Linear Height Gauge/ Slip Gauge Blocks, Long 0 to 300 mm Height: 4µm
2D Height Gauge Gauge Blocks, Lever Dial & Squareness: 4µm
(Height, Squareness) Master Cylinder
LC:0.0001mm
42 Linear Height Gauge/ Slip Gauge Blocks, Long 0 to 600 mm Height: 6µm
2D Height Gauge Gauge Blocks, Lever Dial & Squareness: 4µm
(Height, Squareness) Master Cylinder
LC:0.0001mm
43 Linear Height Gauge/ Slip Gauge Blocks, Long 0 to 1000 mm 8µm
2D Height Gauge Gauge Blocks & Lever Dial
(Height only)
LC:0.0001mm
44 Master Cylinder, Master Cylinder & Slip 50 mm to 600 5µm
Granite Square, Gauge Blocks mm
Granite Square Block, (IS 12937:1990 RA 2020)
Frame Level -
Squareness
45 Measuring Pin/ Universal Length 0.1 mm to 85 1µm
Cylindrical Setting Measuring Machine mm
Master (IS –11103:1984 RA 2020)

46 Measuring Tape, Measuring Tape & Scale 0 to 200 m 0.02*L-2 mm (L in m)


Circumference Tape, Calibrator
PI Tape, Diameter (IS 1269 (Part-1,2) :1997
Tape RA 2018)

Dealing Officer
Page 23 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

47 Outside Pistol Caliper/ Slip Gauge Blocks 0 to 100 mm 1.8µm


Outside Caliper Gauge
LC:0.001mm

48 Thread Pitch Gauge/ Profile Projector 55 ° to 60 ° 3’


Anvil & Spindle Tip of (IS – 4211:1993 RA 2019)
Thread Pitch
Micrometer -Flank
Angle
49 Plain Plug Gauge/ Universal Length 1 mm to 100 2.4µm
Setting Plug Gauge/ Measuring Machine mm
Air Plug Gauge (IS-3455:1971 RA 2020)

50 Plain Plug Gauge/ Universal Length 100 mm to 300 4µm


Setting Plug Gauge/ Measuring Machine mm
Air Plug Gauge (IS-3455:1971 RA 2020)

51 Plain Ring Gauge/ Universal Length 100 mm to 200 3µm


Setting Ring/ Air Ring Measuring Machine mm
Gauge (IS-3455:1971 RA 2020, IS
3485: 1983 RA 2019)
52 Plain Ring Gauge/ Universal Length 3 mm to 100 1.4µm
Setting Ring/ Air Ring Measuring Machine mm
Gauge (IS-3455:1971 RA 2020, IS
3485: 1983 RA 2019)
53 Plunger Dial (Dial Universal Length 0 to 50 mm 1µm
Indicator) LC:0.001mm Measuring Machine, Dial
Calibration Tester
(IS 2092:1985 RA
2019)
54 Plunger Dial (Dial Universal Length 0 to 100 mm 3µm
Indicator)/LVDT Measuring Machine, Dial
LC:0.01mm Calibration Tester
(IS 2092:1985 RA
2019)
55 Radius Gauge/ Radius Profile Projector 0.2 mm to 100 10µm
Template/ Radius (IS – 5273:1969 RA 2019) mm
Chart

Dealing Officer
Page 24 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

56 Receiving Gauge/ Profile Projector 0 to 360 ° 3’


Profile Gauge / Profile
of Work Piece
-Angle
57 Receiving Gauge/ Universal Length 0 to 600 mm 9µm
Profile Gauge / Profile Measuring Machine, Profile
of Work Piece Projector, Slip Gauge
-Length Blocks, Lever Dial, Digital
Caliper, Height Gauge
58 Receiving Gauge/ Profile Projector 0.2 to 100 mm 10µm
Profile Gauge / Profile
of Work Piece
-Radius
59 Snap Gauge/ Width Universal Length 1 mm to 100 2µm
Gauge Measuring Machine, Slip mm
Gauge Blocks &
Accessories
(IS-3455:1971 RA 2020,
IS-7876:1975 RA 2020)
60 Snap Gauge/ Width Universal Length 100 mm to 300 4µm
Gauge Measuring Machine, Slip mm
Gauge Blocks &
Accessories
(IS-3455:1971 RA 2020,
IS-7876:1975 RA 2020)
61 Sphere Ball/ Steel Ball/ Universal Length 0.5 mm to 100 1.30µm
Ball Gauge Measuring Machine mm

62 Spline/ Serration Plug Universal Length 3 mm to 100 4µm


Gauge -Over Pins Measuring Machine mm
Diameter (IS 4966 (Part 2):1969 RA
2019)
63 Spline/ Serration Ring Slip Gauge Blocks 6 mm to 100 3.4µm
Gauge - Between Pins (IS 4966 (Part 1):1969 RA mm
Diameter 2019)

Dealing Officer
Page 25 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

64 Sprit Level/ Frame Electronic Level and Tilting 0 to ±2 mm/m 0.007mm/m


Level LC:0.01mm/m Table
(IS -5706:1993-RA-2022)

65 Steel Scale/ Measuring Measuring Tape & Scale 0 to 3000 mm 0.02*L-2 mm (L in m)


Scale/ Wooden Scale/ Calibration System
Graduated Scale (IS 1481: 1970 RA 2019)

66 Surface Plate - Electronic Level 1000x630 mm 1*{(L+W)/125}-2 µm


Flatness (IS 12937:1990 RA 2020) (L&W in mm)

67 Taper Scale L.C: Profile Projector 0.1 mm to 50 7.1µm


0.1mm mm

68 Taper Thread Plug Universal Length 3 mm to 300 3µm


Gauge (Effective and Measuring Machine mm
Major Dia)

69 Taper Thread Ring Universal Length 3 mm to 100 3µm


Gauge (Effective Dia) Measuring Machine mm

70 Test Mandrel Universal Length 10 mm to 100 2.2µm


(Diameter Variation, Measuring Machine, Lever mm
Total Runout) Dial
(IS 2063:2016)
71 Test Sieve Digital Caliper >5 mm to 150 15µm
(IS – 460 (PART-1,2&3) : mm
2020)

72 Test Sieve Profile Projector 0.025 mm to 5 8.2µm


(IS – 460 (PART-1,2&3) : mm
2020)

73 Thread Measuring Universal Length 0.17 mm to 6.3 1µm


Wire/ Three Wire Unit Measuring Machine mm

Dealing Officer
Page 26 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

74 Thread Pitch Gauge/ Profile Projector 0.2 mm to 20 7µm


Pitch of Work Piece - (IS – 4211:1993 RA 2019) mm
Pitch Length

75 Thread Plug Gauge/ Universal Length 1 mm to 100 3µm


Wear Check Plug - Measuring Machine & mm
Major Diameter - Thread Measuring Wire Set
Effective Diameter (IS-2334:2001 RA 2023
76 Thread Plug Gauge/ Universal Length 100 mm to 300 4µm
Wear Check Plug - Measuring Machine mm
Major Diameter - (IS-2334:2001 RA 2023
Effective Diameter
77 Thread Ring Gauge / Universal Length 100 mm to 200 4µm
Wear Check Ring - Measuring Machine mm
Effective Diameter (IS-2334:2001 RA 2023

78 Thread Ring Gauge / Universal Length 3 mm to 100 1.7µm


Wear Check Ring - Measuring Machine mm
Effective Diameter (IS-2334:2001 RA 2023

79 Try Square/ Engineer's Lever Dial, Master 50 mm to 300 Parallelism: 4 µm


Square (Parallelism, Cylinder, Granite Square, mm Squareness: 4 µm
Squareness) Slip Gauge Blocks
(IS-2103:1980 RA 2017)
80 Ultrasonic Thickness Slip Gauge Blocks 0 to 225 mm 18µm
Gauge LC:0.01mm

81 V Anvil Micrometer Measuring Pin 1 mm to 85 mm 2µm


LC:0.001 mm

82 V Block (Squareness, Master Cylinder, Granite 25 mm to 200 Squareness: 4µm


Parallelism, Flatness, Square, Slip Gauge Blocks, mm Parallelism: 4µm
Symmetricity) Lever Dial, Test Mandrel Flatness: 4µm
(IS –2949: 1992,RA 2017) Symmetricity: 4µm
83 Weld Fillet Gauge/ Profile Projector 1 ° to 90 ° 2'
Weld Gauge/ Hi-Lo
Gauge/ Bridge Cam

Dealing Officer
Page 27 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Gauge/ Chamfer
Gauge -Angle

84 Weld Fillet Gauge/ Profile Projector 0 to 60 mm 7.1µm


Weld Gauge/Hi-Lo
Gauge/ Bridge Cam
Gauge/ Chamfer
Gauge/ Wet Film
Thickness Gauge -
Length
85 Wire Gauge Profile Projector 0.19 mm to 7.82 7µm
mm

86 Caliper Checker/ Step Slip Gauge Blocks, Long 0 to 660 mm 6µm


Gauge Gauge Blocks, Lever Dial

87 Caliper Checker/ Step Slip Gauge Blocks, Long 0 to 300 mm 4µm


Gauge/ Depth Micro- Gauge Blocks, Lever Dial
Checker

88 Dial Calibration Tester Slip Gauge Blocks 0 to 25 mm 1µm


LC:0.0001 mm

89 Electronic Probe/ Slip Gauge Blocks 0 to 25 mm 0.8µm


Digimatic
Indicator/LVDT
LC:0.0001 mm
90 Measuring Tape & Slip Gauge Blocks, Long 0 to 1000 mm 10µm
Scale Calibrator Gauge Blocks
LC:0.0001 mm

91 Profile Projector - Angle Gauge Set 0 ° to 360 ° 2


Angular Scale (L.C: 1'') (JIS B 7184:2021)

Dealing Officer
Page 28 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

92 Profile Projector - Slip Gauge Blocks, Glass 0 to 250 mm 3.1 µm


Linear Scale (L.C: Scale Angle Gauge Set
0.001mm) (JIS B 7184:2021)

93 Profile Projector - Glass Scale, Slip Gauge 10 X to 100 X 0.4%


Magnification Blocks, Digital Caliper
Angle Gauge Set
(JIS B 7184:2021)
94 Universal Length Slip Gauge Blocks 0 to 100 mm 0.5µm
Measuring Machine/
Universal Length
Measuring Machine/
Length Measuring
Machine LC:0.0001
mm
95 Slip Gauge Blocks Tungsten Carbide Slip 0.5 mm to 25 0.10µm
Gauge Set, Slip Gauge mm
Calibrator
(IS 2984 : 2003 RA 2019)
96 Slip Gauge Blocks Tungsten Carbide Slip 25 mm to 50 0.12µm
Gauge Set, Slip Gauge mm
Calibrator
(IS 2984 : 2003 RA 2019)
97 Slip Gauge Blocks Tungsten Carbide Slip 50 mm to 75 0.15µm
Gauge Set, Slip Gauge mm
Calibrator
(IS 2984 : 2003 RA 2019)
98 Slip Gauge Blocks Tungsten Carbide Slip 75 mm to 100 0.30µm
Gauge Set, Slip Gauge mm
Calibrator
(IS 2984 : 2003 RA 2019)
99 Surface Roughness Surface Roughness Tester Ra 0.1 µm to 7%
Specimen 3.2 µm

100 Surface Roughness Roughness Specimen Set Ra 0 to 3.2 µm 7%


Tester (3 Nos.)

Dealing Officer
Page 29 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

101 Laser Distance Meter Slip Gauge Blocks, Long 0 to 2000 mm 0.6 mm
Gauge Blocks, Accessories

Hardness
1 Durometer/ Rubber Load Cell with Indicator, 0 to 100 Shore 0.3 Shore Unit
Hardness Tester Weighing Balance & Unit
(Shore A, B, C, D, O, Fixture based on ASTM D
DO) 2240-15:2017 by
direct method
2 Rockwell Hardness Reference Hardness 10 to 100 1.2 HRBW
Tester (Portable) Blocks based on IS 1586 HRBW
Part 2: 2018

3 Rockwell Hardness Reference Hardness 10 to 70HRC 1 HRC


Tester (Portable) Blocks based on IS 1586
(Part 2): 2018 by direct
methd
Force
1 Push Pull Gauge, Slotted Weights, Hanger 50 N to 2000 N 0.6%
Force Gauge - Weights & Frame Weights
Push/Pull Mode based on VDI/VDE 2624-
2.1 :2008
2 Push Pull Gauge, Slotted Weights, Hanger 0.1 N to 50 N 0.6%
Force Gauge, Tension Weights & Frame Weights
Gauge - Push/Pull based on VDI/VDE 2624-
Mode 2.1 :2008
Pressure & Vacuum
1 Hydraulic Pressure - Digital Pressure Gauge, 0 bar to 700 bar 0.30 bar
Digital/ Dial Pressure Digital Multimeter based on
Gauge, Pressure DKD R6-1:2014
Transducer/
Transmitter/ Controller
2 Pneumatic Pressure Digital Pressure Gauge, 0 bar to 35 bar 0.02 bar
-Digital/ Dial Pressure Digital Multimeter based on
Gauge, Pressure DKD R6-1:2014
Transducer/
Transmitter/ Controller

Dealing Officer
Page 30 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

3 Pneumatic Pressure- Digital Pressure Gauge, 0 bar to 7 bar 0.004bar


Digital/ Dial Pressure Digital Multimeter based on
Gauge, Pressure DKD R6-1:2014
Transducer/
Transmitter/ Controller/
Differential Gauge/
Manometer
4 Pneumatic Pressure Digital Pressure Gauge 0 kPa to 20 kPa 0.02kPa
-Low Pressure Gauge, based on DKD R6-1:2014
Manometer,
Magnehelic Gauge,
Differential Gauge/
Controller
5 Pneumatic Pressure Digital Manometer based 0 Pa to 2000 Pa 1 Pa
-Low Pressure Gauge, on DKD R6-1:2014
Manometer,
Magnehelic Gauge,
Differential Gauge/
Controller
6 Vacuum -Digital/ Dial Digital Pressure Gauge -0.9 to 0 bar 0.004bar
Vacuum Gauge, based on DKD R6-1:2014
Vacuum Transducer/
Transmitter/ Controller
Torque

1 Torque Generating Torque Sensors with 0.02 Nm to 500 1.2 % to 0.8 %


Tools (Type I & II), Indicator based on Nm
Rotary Torque Tools, (IS 16906:2018)
Torque Driver, Nut
Runner, Torque Gauge
2 Torque Transducer, Slotted Weights, Lever 0.02 Nm to 50 0.12%
Torque Sensor Arm, Pulley & Digital Nm
with/without Indicator, Multimeter based on BS
Torque Meter, Torque 7882:2017
Wrench Calibrator
3 Torque Transducer, Slotted Weights, Lever Arm 10 Nm to 2000 0.09%
Torque Sensor & Digital Multimeter based Nm
with/without Indicator, on BS 7882 :2017

Dealing Officer
Page 31 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Torque Meter, Torque


Wrench Calibrator

Volume

1 Volumetric Weighing 0.1 ml to 50 ml 0.007 ml


Measures(Beaker, Balance LC:0.01 mg
Measuring Cylinder, & Distilled Water based on
Burette, Pipette, Flask, ISO 4787:2021 by
Bottle, Density Bottle, gravimetric method
Density Backet, Cone,
Condenser, Dispenser,
Dish, Funnel, Tube,
Syringe, Container
etc.)
2 Volumetric Weighing 50 ml to 200 ml 0.01 ml
Measures(Beaker, Balance LC:0.1 mg
Measuring Cylinder, & Distilled Water based on
Burette, Pipette, Flask, ISO 4787:2021 by
Bottle, Density Bottle, gravimetric method
Density Backet, Cone,
Condenser, Dispenser,
Dish, Funnel, Tube,
Syringe, Container
etc.)
3 Volumetric Weighing 200 ml to 950 0.05 ml
Measures(Beaker, Balance LC:1 mg & ml
Measuring Cylinder, Distilled Water based on
Burette, Pipette, Flask, ISO 4787:2021 by
Bottle, Density Bottle, gravimetric method
Density Backet, Cone,
Condenser, Dispenser,
Dish, Funnel, Tube,
Syringe, Container
etc.)
4 Volumetric Weighing 1000 ml to 5000 0.1 ml
Measures(Beaker, Balance LC:10 mg & ml
Measuring Cylinder, Distilled Water based on

Dealing Officer
Page 32 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Flask, Bottle, Density ISO 4787:2021 by


Backet, Container etc.) gravimetric method

5 Volumetric Measures WeighingBalance LC:0.1 g 5 l to 15 l 1 ml


(Measuring Cylinder, &Distilled Water based on
Bottle, Density Backet, ISO 4787:2021 by
Container etc.) gravimetric method
6 Volumetric Measures Weighing 15 l to 30 l 10 ml
(Density Backet, Balance LC:1 g & Distilled
Container etc.) Water based on ISO
4787:2021 by gravimetric
method
7 Piston Operated Weighing 20 µl to 100 µl 0.1 µl
Volumetric Apparatus Balance LC:0.01 mg
(Micro-pipettes) & Distiled Water based on
ISO 8655-6: 2022 by
gravimetric method
8 Piston Operated Weighing Balance LC:0.01 100 µl to 1000 1 µl
Volumetric Apparatus mg µl
(Micro-pipettes) & Distiled Water based on
ISO 8655-6: 2022 by
gravimetric method
9 Piston Operated Weighing 1000 µl to 10 µl
Volumetric Apparatus Balance LC:0.01 mg 10000 µl
(Micro-pipettes) & Distiled Water based on
ISO 8655-6: 2022 by
gravimetric method
Weighing Balance

1 Weighing E1 Class 0 to 60 g 0.004 mg


Balance/Scale/System, Weights based on OIML R
Densitometer 76-1 :2006
Class-I, d=0.01 mg or
coarser

Dealing Officer
Page 33 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

2 Weighing E1 Class 0 to 220 g 0.2 mg


Balance/Scale/System, Weights based on OIML R
Densitometer 76- 1 :2006
Class-I, d=0.1 mg or
coarser
3 Weighing E1/F1 Class 0 to 1 kg 2 mg
Balance/Scale/System Weights based on OIML R
Class- I, d=1 mg or 76- 1 :2006
coarser
4 Weighing E1/F1 Class 0 to 6 kg 0.02 g
Balance/Scale/System Weights based on OIML R
Class- I, d=10 mg or 76- 1 :2006
coarser
5 Weighing F1 Class 0 to 20 kg 0.1 g
Balance/Scale/System Weights based on OIML R
Class- III, d=0.1 g or 76-1 :2006
coarser
6 Weighing F1 Class 0 to 50 kg 0.8 g
Balance/Scale/System Weights based on OIML R
Class- III, d=1 g or 76-1 :2006
coarser
7 Spring Balance Slotted & Hanger Weights 0 to 10 kg 5g

8 Spring Balance Slotted & Hanger Weights 0 to 50 kg 10 g

9 Spring Balance Slotted & Hanger Weights 0 to 200 kg 20 g

Mass

1 Weight-F2 Class & E1 Class Weights & 1 mg 0.02 mg


Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method

Dealing Officer
Page 34 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

2 Weight-F2 Class & E1 Class Weights & 2 mg 0.02 mg


Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
3 Weight-F2 Class & E1 Class Weights & 5 mg 0.02 mg
Coarser Weighing Balance of
LC:0.01 mgbased on OIML
R111-1:2004 bysubstitution
method
4 Weight-F2 Class & E1 Class Weights & 10 mg 0.02 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
5 Weight-F2 Class & E1 Class Weights & 20 mg 0.02 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
6 Weight-F2 Class & E1 Class Weights & 50 mg 0.02 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
7 Weight-F2 Class & E1 Class Weights & 100 mg 0.02 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
8 Weight-F2 Class & E1 Class Weights & 200 mg 0.02 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-

Dealing Officer
Page 35 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

1:2004 by
substitution method

9 Weight-F2 Class & E1 Class Weights & 500 mg 0.02 mg


Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
10 Weight-F1 Class & E1 Class Weights & 1g 0.02 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
11 Weight-F1 Class & E1 Class Weights & 2g 0.03 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
12 Weight-F1 Class & E1 Class Weights & 5g 0.03 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
13 Weight-F1 Class & E1 Class Weights & 10 g 0.03 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
14 Weight-F1 Class & E1 Class Weights & 20 g 0.03 mg
Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-

Dealing Officer
Page 36 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

1:2004 by
substitution method

15 Weight-F1 Class & E1 Class Weights & 50 g 0.04 mg


Coarser Weighing Balance of
LC:0.01 mg
based on OIML R111-
1:2004 by
substitution method
16 Weight-F1 Class & E1 Class Weights & 100 g 0.2 mg
Coarser Weighing Balance of
LC:0.1 mg
based on OIML R111-
1:2004 by
substitution method
17 Weight-F1 Class & E1 Class Weights & 200 g 0.2 mg
Coarser Weighing Balance of
LC:0.1 mgbased on OIML
R111-1:2004 bysubstitution
method
18 Weight-F2 Class & F1 Class Weights & 500 g 2 mg
Coarser Weighing Balance of LC:1
mg based on OIML R111-
1:2004 by
substitution method
19 Weight-F2 Class & F1 Class Weights & 1 kg 2 mg
Coarser Weighing Balance of LC:1
mg based on OIML R111-
1:2004 by
substitution method
20 Weight-M1 Class & F1 Class Weights & 2 kg 0.02 g
Coarser Weighing Balance of
LC:0.01 g
based on OIML R111-
1:2004 by
substitution method

Dealing Officer
Page 37 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

21 Weight-M1 Class & F1 Class Weights & 5 kg 0.03 g


Coarser Weighing Balance of
LC:0.01 g
based on OIML R111-
1:2004 by
substitution method
22 Weight-M1 Class & F1 Class Weights & 10 kg 0.2 g
Coarser Weighing Balance of
LC:0.1 g
based on OIML R111-
1:2004 by
substitution method
23 Weight-M1 Class & F1 Class Weights & 20 kg 0.2 g
Coarser Weighing Balance of
LC:0.1 g
based on OIML R111-
1:2004 by
substitution method
24 Weight-M1 Class & F1 Class Weights & 50 kg 1g
Coarser Weighing Balance of LC:1
g
based on OIML R111-
1:2004 by
substitution method
25 Non Standard Weight E1 Class Weights & 1g to 50 g 0.1 mg
Weighing Balance of
LC:0.01 mg
by substitution method
26 Non Standard Weight E1 Class Weights & >50 g to 200 g 1 mg
Weighing Balance of
LC:0.1 mg
by substitution method
27 Non Standard Weight F1 Class Weights & >200 g to 1 kg 0.01 g
Weighing Balance of
LC:0.001 g
by substitution method

Dealing Officer
Page 38 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

28 Non Standard Weight F1 Class Weights & >1 kg to 6 kg 0.02 g


Weighing Balance of
LC:0.01 g
by substitution method
29 Non Standard Weight F1 Class Weights & >6 kg to 20 kg 0.2 g
Weighing Balance of
LC:0.1 g
by substitution method
30 Non Standard Weight F1 Class Weights & >20 kg to 50 kg 1g
Weighing Balance of LC:1
g
by substitution method

Dealing Officer
Page 39 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Acceleration & Speed

1 RPM Meter - Contact Mode Tachometer 10 rpm to 3000 4 % to 0.1 %


(SANASTR45-II-2017) rpm

2 RPM Meter/ Centrifuge/ Tachometer 10 rpm to 4 % to 0.1 %


RPM measurement of (SANASTR45-II-2017) 99999 rpm
moving object -Non- Contact
Mode
3 Tachometer Calibrator/ Tachometer 10 rpm to 4 % to 0.1 %
Stroboscope (SANASTR45-II-2017) 99999 rpm

4 RPM Meter -Non- Contact Stop Watch 1 rpm to 10 1% to 0.1 %


Mode (SANASTR45-II-2017) rpm

5 Vibration - Acceleration (10 Portable Vibration 1 m/s² to 100 7 % to 4 %


Hz to 300 Hz) Calibrator m/s²

6 Vibration - Displacement (10 Portable Vibration 0.01 mm to 2 7 % to 4 %


Hz Calibrator mm
to 100 Hz)

7 Vibration -Velocity (10 Hz to Portable Vibration 12.5 mm/s to 7 % to 4 %


500 Hz) Calibrator 160 mm/s

8 Speed of Material Testing Digital Height Gauge & 0 to 500 0.21%


Machines (UTM, TTM, LTM, Stop Watch mm/min
CTM)

Dimension

1 Air Gauge Unit Standard Ring Gauge 0 to ±40 µm 2µm


Set

Dealing Officer
Page 40 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

2 Bench Centre – Coaxiality of Test Mandrel, Lever Dial 300mm to 5µm


Centres (IS 5980:1978 RA 500mm
2020)

3 Caliper LC:0.01 mm Slip Gauge Block Set, 0 to 2000 mm 30µm


Caliper Checker, Long
Gauge Blocks
(IS 16491(part-1):2016
RA2021)
4 Displacement Measuring Digital Height Gauge 0 to 600 mm 10 µm
Equipment of Testing
Machine
(LVDT/Actuator/Encoder)
5 Linear Height Gauge/ 2D Slip Gauge Blocks, Long 0 to 300 mm Height: 4µm
Height Gauge/ Height Gauge Blocks, Lever Squareness: 4µm
Gauge (Height, Squareness) Dial & Master Cylinder
LC:0.0001mm
6 Linear Height Gauge/ 2D Slip Gauge Blocks, Long 0 to 600 mm Height: 6µm
Height Gauge/ Height Gauge Blocks, Lever Squareness: 4µm
Gauge (Height, Squareness) Dial & Master Cylinder
LC:0.0001mm
7 Linear Height Gauge/ 2D Slip Gauge Blocks, Long 0 to 1000 mm 8µm
Height Gauge/ Height Gauge Blocks & Lever
Gauge (Height only) Dial
LC:0.0001mm
8 Straight Edge - Straightness Electronic Level 200 mm to 1*{(L+W)/125}-2 µ
(IS 12937:1990 RA 3000 mm m (L&W in mm)
2020)

9 Surface Plate - Flatness Electronic Level 300x300 mm 1*{(L+W)/125}-2 µ


(IS 12937:1990 RA to 6000x6000 m (L&W in mm)
2020) mm

10 Measuring Tape & Scale Slip Gauge Blocks, Long 0 to 1000 mm 10µm
Calibrator LC:0.0001 mm Gauge Blocks

Dealing Officer
Page 41 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

11 Optical Microscope/ Using Glass Scale 0 to 1 mm 3µm


Metallurgical Microscope -
Linear Scale (LC: 0.001µm)

12 Optical Microscope/ Using Glass Scale 2 X to 2000 X 2%


Metallurgical Microscope -
Magnification

13 Profile Projector/ Measuring Angle Gauge Set 0 ° to 360 ° 40"


Microscope -Angular Scale (JIS B 7184:2021)
(LC:1")

14 Profile Projector/ Measuring Slip Gauge Blocks, 0 to 400 mm 4µm


Microscope -Linear Scale Glass Scale
(LC: 0.001 (JIS B 7184:2021)
mm)
15 Profile Projector/ Measuring Slip Gauge Blocks, 10 X to 100 X 0.4%
Microscope - Magnification Glass Scale, Digital
Caliper
(JIS B 7184:2021)
16 Universal Length Measuring Slip Gauge Blocks 0 to 100 mm 0.5µm
Machine/ Universal Length
Measuring Machine/ Length
Measuring Machine
LC:0.0001 mm
17 Surface Roughness Tester Roughness Specimen Ra 0 to 3.2 µm 7%
Set (3 Nos.)

18 Vision Measuring Machine - Angle Gauge Set 0 ° to 360 ° 40"


Angular Scale (LC:0.01")

19 Vision Measuring Machine - Glass Scale, Long 0 to 600 mm 3µm


Linear Scale (LC: 0.001µm) Gauge Blocks

Dealing Officer
Page 42 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

20 Coordinate Measuring Slip Gauge Blocks, Long 0 to 1000 mm 3+L/500 µm


Machine (CMM) Gauge Blocks, Test (L in mm)
Sphere (IS 15635 (Part
2):2014 RA 2021)
Hardness

1 Rockwell Hardness Tester Reference Hardness 10 to 100 1.2 HRBW


Blocks based on IS 1586 HRBW
Part 2: 2018

2 Rockwell Hardness Tester Reference Hardness 10 to 70 HRC 1 HRC


Blocks based on IS 1586
(Part 2): 2018 by direct
methd
Pressure & Vacuum

1 Hydraulic Pressure - Digital/ Digital Pressure Gauge, 0 bar to 700 0.30 bar
Dial Pressure Gauge, Digital Multimeter based bar
Pressure Transducer/ on DKD R6-1:2014
Transmitter/ Controller
2 Pneumatic Pressure Digital Pressure Gauge, 0 bar to 35 bar 0.02 bar
-Digital/ Dial Pressure Digital Multimeter based
Gauge, Pressure on DKD R6-1:2014
Transducer/ Transmitter/
Controller
3 Pneumatic Pressure Digital Pressure Gauge, 0 bar to 7 bar 0.004bar
-Digital/ Dial Pressure Digital Multimeter based
Gauge, Pressure on DKD R6-1:2014
Transducer/ Transmitter/
Controller/ Differential
Gauge/ Manometer
4 Pneumatic Pressure Digital Pressure Gauge 0 kPa to 20 0.02kPa
-Low Pressure Gauge, based on DKD R6- kPa
Manometer, Magnehelic 1:2014
Gauge, Differential Gauge/
Controller
5 Pneumatic Pressure Digital Manometer based 0 Pa to 2000 1 Pa
-Low Pressure Gauge, on DKD R6-1:2014 Pa
Manometer, Magnehelic

Dealing Officer
Page 43 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Gauge, Differential Gauge/


Controller

6 Vacuum -Digital/ Dial Digital Pressure Gauge -0.9 to 0 bar 0.004bar


Vacuum Gauge, Vacuum based on DKD R6-
Transducer/ Transmitter/ 1:2014
Controller
Force

1 Uniaxial Static Testing Force Proving 10N to 600 kN 0.5%


Machines (Universal Testing Instruments (Load Cells/
Machine, Compression Proving Rings) based on
Testing Machine, Load IS 1828 (Part 1) :2022
Testing Machine, Force
Testing Machine, Spring
Testing Machine) -
Compression Mode
2 Uniaxial Static Testing Force Proving 10 N to 100 kN 0.4%
Machines (Universal Testing Instruments (Load Cells/
Machine, Tensile Testing Proving Rings) based on
Machine, Load Testing IS 1828 (Part 1) :2022
Machine, Force Testing
Machine, Spring Testing
Machine) -Tension Mode
3 Uniaxial Static Testing Newtonian Weights 0.1 to 10 N 0.4%
Machines (Universal Testing based on IS 1828 (Part
Machine, Compression 1) :2022
Testing Machine, Load
Testing Machine, Force
Testing Machine, Spring
Testing Machine) - Tension/
Compression Mode
Weighing Balance
1 Weighing E1 Class 0 to 21 g 0.004 mg
Balance/Scale/System, Weights based on OIML
Densitometer R 76-1:2006
Class-I, d=0.001 mg or
coarser

Dealing Officer
Page 44 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

2 Weighing E1 Class 0 to 80 g 0.004 mg


Balance/Scale/System, Weights based on OIML
Densitometer R 76-1:2006
Class-I, d=0.01 mg or
coarser
3 Weighing E1 Class 0 to 220 g 0.004
Balance/Scale/System, Weights based on OIML
Densitometer R 76-1:2006
Class-I, d=0.01 mg or
coarser
4 Weighing E1 Class 0 to 320 g 0.2
Balance/Scale/System, Weights based on OIML
Densitometer R 76-1:2006
Class-I, d=0.1 mg or coarser
5 Weighing E1/F1 Class 0 to 1 kg 0.002 g
Balance/Scale/System Weights based on OIML
Class- I, d=1 mg or coarser R 76-1:2006

6 Weighing E1/F1 Class 0 to 10 kg 0.02 g


Balance/Scale/System Weights based on OIML
Class- I, d=10 mg or coarser R 76-1:2006

7 Weighing F1 Class 0 to 20 kg 0.1 g


Balance/Scale/System Weights based on OIML
Class- III, d=0.1 g or coarser R 76-1:2006

8 Weighing F1 Class 0 to 50 kg 0.8 g


Balance/Scale/System Weights based on OIML
Class- III, d=1 g or coarser R 76-1:2006

9 Weighing F1 Class 0 to 100 kg 2g


Balance/Scale/System Weights based on OIML
Class- III, d=1 g or coarser R 76-1:2006

10 Weighing F1 ClassWeights based 0 to 300 kg 10 g


Balance/Scale/SystemClass- on OIML R 76-1:2006
III, d=5 g or coarser

Dealing Officer
Page 45 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Mechanical Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

11 Weighing F1/M1 Class 0 to 500 kg 15 g


Balance/Scale/System Weights based on OIML
Class- IIII, d=5 g or coarser R 76-1:2006

12 Weighing F1/M1 Class 0 to 1000 kg 20 g


Balance/Scale/System Weights based on OIML
Class- IIII, d=10 g or coarser R 76-1:2006

13 Weighing F1/M1 Class 0 to 2000 kg 20 g


Balance/Scale/System Weights based on OIML
Class- IIII, d=20 g or coarser R 76-1:2006

14 Weighing F1/M1 Class 0 to 3000 kg 50 g


Balance/Scale/System Weights based on OIML
Class- IIII, d=50 g or coarser R 76-1:2006

Dealing Officer
Page 46 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Thermal Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

1 Relative Humidity Relative Humidity & 10 % RH to 95 2% RH


Indicator/ Controller/ Temperature Sensor with % RH
Logger/ Recorder with Indicator by comparison
Sensor of Relative method
Humidity Chamber
-Single Position
Calibration (@10 to
50°C)
2 Thermo-Hygrometer/ Relative Humidity & 20 % RH to 95 1.5% RH
Relative Humidity Temperature Sensor with % RH
Sensors/ Transmitter Indicator, Relative
with/ without Indicator/ Humidity & Temperature
Controller/ Data Logger/ Chamber by comparison
Recorder (@10°C to method
50°C)
3 Temperature Indicator/ PRT/RTD with Precision -30 °C to 650 0.2°C
Controller/ Logger/ Temperature Scanner/ °C
Recorder with Sensor of Digital Thermometer by
Dry Blocks, Liquid Baths comparison method
-Single Position
Calibration
4 Temperature Indicator/ S Type Thermocouple with 250 °C to 1200 1.2°C
Controller/ Logger/ Precision Temperature °C
Recorder with Sensor of Scanner/ Digital
Dry Block -Single Thermometer by
Position Calibration comparison method
5 Infrared (IR) Infrared Thermometer with 30 °C to 500 °C 2°C
Thermometer/ Thermal Black Body by comparison
Imager Camera, method
Pyrometer Emissivity:
0.95±0.01
6 Temperature Indicator/ Infrared Thermometer by 30 °C to 500 °C 2.2°C
Controller/ Logger/ comparison method
Recorder with Sensor of
Blackbody
7 Liquid in Glass PRT/RTD with Precision -30 °C to 250 0.3°C
Thermometer Temperature Scanner/ °C
Digital Thermometer,

Dealing Officer
Page 47 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Thermal Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Liquid Bath by comparison


method

8 RTD/ Thermocouple/ PRT/RTD with Precision -30 °C to 50 °C 0.1°C


Temperature Temperature Scanner/
Transmitter/ Thermister Digital Thermometer/
with/without Indicator/ Digital Multimeter, Dry
Controller/ Recorder/ Well/ Liquid Bath/ Dry
Data Logger, Block Furnace by
Temperature Gauge, comparison method
Digital Thermometer with
Sensor
9 RTD/ Thermocouple/ PRT/RTD with Precision 50 °C to 150 °C 0.1°C
Temperature Temperature Scanner/
Transmitter/ Thermister Digital Thermometer/
with/without Indicator/ Digital Multimeter, Dry
Controller/ Recorder/ Well/ Liquid Bath/ Dry
Data Logger, Block Furnace by
Temperature Gauge, comparison method
Digital Thermometer with
Sensor
10 RTD/ Thermocouple/ PRT/RTD with Precision 150 °C to 650 0.2°C
Temperature Temperature Scanner/ °C
Transmitter/ Thermister Digital Thermometer/
with/without Indicator/ Digital Multimeter, Dry
Controller/ Recorder/ Well/ Liquid Bath/ Dry
Data Logger, Block Furnace by
Temperature Gauge, comparison method
Digital Thermometer with
Sensor
11 Thermocouple/ S Type Thermocouple with 250 °C to 1200 1.5°C
Temperature Transmitter Precision Temperature °C
with/without Indicator/ Scanner/ Digital
Controller/ Recorder/ Multimeter, Dry Well/ Dry
Data Logger, Digital Block Furnace by
Thermometer with comparison method
Sensor

Dealing Officer
Page 48 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Thermal Calibration (Laboratory Based)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

12 Wireless Temperature Relative Humidity & 10 °C to 50 °C 0.3°C


Indicator/ Data Temperature Sensor with
Logger/Thermo- Indicator, Relative
Hygrometer Humidity & Temperature
(@50% RH) Chamber by comparison
method
13 Wireless Temperature PRT/RTD with Precision -5 °C to 10 °C 0.3°C
Indicator/ Data Temperature Scanner/
Logger/Thermo- Digital Thermometer,
Hygrometer Relative Humidity &
Temperature Chamber by
comparison method

Dealing Officer
Page 49 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Thermal Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

1 Relative Humidity Wireless Data Loggers by 30 % RH to 95 3% RH


Chamber/ Environmental comparison method % RH
Chamber -Thermal
Mapping (@25°C)
2 Relative Humidity Relative Humidity & 10% RH to 95 2% RH
Indicator/ Controller/ Temperature Sensor with % RH
Logger/ Recorder with Indicator by comparison
Sensor of Relative method
Humidity Chamber/
Environmental Chamber
-Single Position
Calibration (@10 to
60°C)
3 Temperature Indicator/ PRT with Precision -80 °C to 30 °C 0.3°C
Controller/ Logger/ Temperature Scanner/
Recorder with Sensor of RTD (4W) with Digital
Environmental/ Climatic Thermometer by
Chamber (Deep Freezer, comparison method
Freezer, Cold Room, Dry
Blocks, Liquid Baths) -
Single Position
Calibration
4 Temperature Indicator/ PRT with Precision 30 °C to 400 °C 0.3°C
Controller/ Logger/ Temperature Scanner/
Recorder with Sensor of RTD (4W) with Digital
Environmental/ Climatic Thermometer by
Chamber (Dry Block, comparison method
Liquid Bath, Oven,
Furnace, Incubator, BOD
Incubator, Autoclave) -
Single Position
Calibration
5 Temperature Indicator/ S Type Thermocouple with 250 °C to 1200 1.2°C
Controller/ Logger/ Precision Temperature °C
Recorder with Sensor of Scanner/ Digital
Environmental/ Climatic Thermometer by
Chamber (Oven, comparison method
Furnace, Muffle Furnace,

Dealing Officer
Page 50 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Thermal Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

Dry Blocks) -Single


Position Calibration

6 Environmental/ Climatic RTD with Data Logger by -80 °C to 30 °C 0.5°C


Chamber (Deep Freezer, comparison method
Freezer, Cold Room,
Refrigerator) - Thermal
Mapping
7 Environmental/ Climatic RTD with Data Logger by 30 °C to 250 °C 1°C
Chamber (Dry Block, comparison method
Liquid Bath, Oven,
Furnace, Incubator, BOD
Incubator, Autoclave) -
Thermal Mapping
8 Oven, Furnace N Type Thermocouples 250 °C to 1200 3°C
-Thermal Mapping with Data Logger by direct °C
method

9 RTD/ Thermocouple/ PRT/RTD with Precision -30 °C to 50 °C 0.1°C


Temperature Temperature Scanner/
Transmitter/ Thermister Digital Thermometer/
with/without Indicator/ Digital Multimeter, Dry
Controller/ Recorder/ Well/ Liquid Bath/ Dry
Data Logger, Block Furnace by
Temperature Gauge, comparison method
Digital Thermometer with
Sensor
10 RTD/ Thermocouple/ PRT/RTD with Precision 50 °C to 150 °C 0.1°C
Temperature Temperature Scanner/
Transmitter/ Thermister Digital Thermometer/
with/without Indicator/ Digital Multimeter, Dry
Controller/ Recorder/ Well/ Liquid Bath/ Dry
Data Logger, Block Furnace by
Temperature Gauge, comparison method
Digital Thermometer with
Sensor

Dealing Officer
Page 51 of 52
FEDERATION FOR DEVELOPMENT OF ACCREDITATION SERVICES
118-119, First Floor, Sushant Tower, Sector – 56, Gurugram – 122011, Haryana, India.

SCOPE OF ACCREDITATION
(Annexure to Certificate of CL – 117)

Thermal Calibration (At Site)

S. No. Parameter Calibration Method/ Range Uncertainty in


Procedure & Equipment Measurement (±) *
used as Reference
Standard

11 RTD/ Thermocouple/ PRT/RTD with Precision 150 °C to 650 0.2°C


Temperature Temperature Scanner/ °C
Transmitter/ Thermister Digital Thermometer/
with/without Indicator/ Digital Multimeter, Dry
Controller/ Recorder/ Well/ Liquid Bath/ Dry
Data Logger, Block Furnace by
Temperature Gauge, comparison method
Digital Thermometer with
Sensor
12 Thermocouple/ S Type Thermocouple with 250 °C to 1200 1.5°C
Temperature Transmitter Precision Temperature °C
with/without Indicator/ Scanner/ Digital
Controller/ Recorder/ Multimeter, Dry Well/ Dry
Data Logger, Digital Block Furnace by
Thermometer with comparison method
Sensor

Dealing Officer
Page 52 of 52