Dixel Prime Programming2
Dixel Prime Programming2
EXTERNAL ALARM
CCt Continuous Cycle duration 0.0 to 24.0 hrs not used not used 0hr 0hr 0hr HIDDEN
COn Compressor on time with Faulty Probe 0 to 255 min 30min 15min 15min 15min 15min HIDDEN
COF Compresser off time with Faulty Probe 0 to 255 min 30min 30min 30min 30min 30min HIDDEN
CH Type of Action (cooling or heating) CL = cooling / Ht = heating CL CL CL not used not used FIRST
CF Temperature Measurement Unit ˚C or ˚F ˚C ˚C ˚C ˚C ˚C HIDDEN
rES Resolution dE = dec.point / in = integer dE dE dE dE dE FIRST
Prd Second Probe read out —- not used not used not used used used HIDDEN
tdF Defrost Type EL = electric heater / in = hot gas not used not used not used EL EL FIRST
dtE Defrost Termination Temperature -50 to +50˚C not used not used not used 8˚C 8˚C FIRST
IdF Interval between Defrost Cycles 0 to 120hrs not used 8hrs 8hrs 6hrs 6hrs FIRST
MdF (MAXIMUM) Length for Defrost 0 to 255 min not used 20min 20min 30min 30min FIRST
dFd Displaying during Defrost re=actual / it = defrost start not used it it it it HIDDEN
SEt = setpoint / dEF = ”dEF” lable
dAd MAX Display delay after Defrost 0 to 255 min not used 30min 30min 30min 30min HIDDEN
HA
CA
EE
EA
P1
P2
LA
Fdt Draining time 0 to 120 min not used not used not used 0min 0min HIDDEN
dPo First Defrost after Startup n = normal / y = immediately not used not used not used n n HIDDEN
dAF Defrost delay after fast Freezing 0 to 23 hrs not used not used not used 0hrs 0hrs HIDDEN
Fnc Fan Operation Mode C-n = on & off with comp. & off in defrost not used not used not used not used o-n FIRST
o-n = fan on except in defrost
ALARM SIGNALS
& Fnd parameter fan is off
C-Y = on & off with comp & on during defrost
o-Y = Always on including defrost
Fnd Fan Delay after Defrost 0 to 255 min not used not used not used not used 10min FIRST
FSt Fan Stop Temperature -50 to 50˚C not used not used not used not used 2˚C FIRST
ALc Temperate Alarms Configuration rE =related to setpoint / Ab = absolute Ab Ab Ab Ab Ab HIDDEN
ALU MAXIMUM Temperature Alarm Setpoint to 150˚C 150˚C 150˚C 150˚C 150˚C 110˚C FIRST
ALL MINIMUM Temperature Alarm -50 to Setpoint -50˚C -50˚C -50˚C -50˚C -50˚C FIRST
ALd Temperature Alarm Delay 0 to 255 min 15min 15min 15min 15min 15min HIDDEN
dAO Delay of temperature alarm at start up 0 to 23 hrs 1hr 1.3hrs 1.3hrs 1.3hrs 1.3hrs HIDDEN
tba Alarm Relay Silencing n = no / y = yes not used not used y not used not used HIDDEN
OAC 2nd Relay Configuration Alr = alarm / dEf = not selected / Aus = auxiliary not used not used AUS not used not used FIRST
i1P Digital Input Polarity oP = opening / CL = closing not used not used CL not used CL FIRST
i1F Digital Input Configuration EAL = external alarm / bAL = lock regulate not used not used AUS not used bAL FIRST
dEF = defrost / AUS = aux activated
did Digital Input Alarm Delay 0 to 255 min not used not used 0min not used 0min FIRST
PbC Probe Selection Ptc or ntc (positive or negative temperature codification) ntc ntc ntc ntc not used FIRST
nPS Kind of Action when i1F = bAL 0 = door switch / 1 = lock regulations / not used not used not used not used O HIDDEN
2-15 = pressure switch
rel Manufacturers Warranty Code UNCHANGEABLE not used not used not used not used not used HIDDEN
Ptb Manufacturers Warranty Code UNCHANGEABLE not used not used not used not used not used HIDDEN
rSt Manufacturers Warranty Code UNCHANGEABLE not used not used not used not used not used FIRST
4568 KIRBY Instruction card._tg 23/11/00 5:14 PM Page 2
PROGRAMMING MODE
CONTINUOUS CYCLE
COMPRESSOR RUN
DEFROST ENABLE
XR60
TO LOCK OR UNLOCK KEYPAD
FANS ENABLE
PRESS ▲ + ▼ KEYS UNTILL “PoF” IS DISPLAYED = KEYPAD LOCKED
NOT USED
PRESS ▲ + ▼ KEYS UNTILL “Pon” IS DISPLAYED = KEYPAD UNLOCKED.
PROGRAMMING MODE
Air Conditioning
CONTINUOUS CYCLE
COMPRESSOR RUN
TO RESET HOLD THE SET KEY FOR MORE THAN 3 SECONDS WHILE “Lo”
NOT USED or “Hi” IS DISPLAYED
Specialists
NOT USED
NOT USED
TO CHANGE SETPOINT
PRESS SET KEY & HOLD FOR 3 SECONDS ( COMPESSOR LED STARTS
BLINKING )
ANTI SHORT CYCLE ENABLE
PROGRAMMING MODE
CONTINUOUS CYCLE
DIXELL-
TO CHANGE A PARAMETER VALUE
COMPRESSOR RUN
SECOND RELAY ON
XR30
DEFROST ENABLE
NOT USED
SETTING PROCEDURE
( LED1 ALSO FLASHING )
(LED2 ALSO FLASHING)
PROGRAMMING MODE
PROGRAMMING MODE
NOT USED
NOT USED
NOT USED
PROGRAMMING MODE
SETTING PROCEDURE
NOT USED
NOT USED
NOT USED
NOT USED
FLASHING
FLASHING
ON
ON
ON
ON
LED2
LED3
LED4
LED5
LED