Dixel Prime Programming2

The document provides an instruction card for the Dixell-Prime series temperature control units, detailing parameter settings, default values, and operational instructions. It includes information on temperature ranges, alarm configurations, and programming modes for various models (XR10C to XR60C). Additionally, it outlines how to access hidden parameters, change setpoints, and manage defrost cycles.

Uploaded by

pratama
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views

Dixel Prime Programming2

The document provides an instruction card for the Dixell-Prime series temperature control units, detailing parameter settings, default values, and operational instructions. It includes information on temperature ranges, alarm configurations, and programming modes for various models (XR10C to XR60C). Additionally, it outlines how to access hidden parameters, change setpoints, and manage defrost cycles.

Uploaded by

pratama
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

4568 KIRBY Instruction card.

_tg 23/11/00 5:14 PM Page 1

PA R A M E T E R TA B L E MIN TO MAX RANGES (FUNCTIONS) D E FA U LT S E T T I N G S


XR10C XR20C XR30C XR40C XR60C Acc.Level
Set Setpoint LS to US 5˚C 3˚C 3˚C 5˚C 5˚C
Hy Differential 0.1 to 25.5˚C 2˚C 2˚C 2˚C 2˚C 2˚C FIRST

THERMOSTAT PROBE FAILURE


EVAPORATOR PROBE FAILURE
LS Minimum Set Point -50˚C to Setpoint -50˚C 50˚C 50˚C 50˚C 50˚C HIDDEN

HIGH TEMPERATURE ALARM


US Maximum Set Point Setpoint to 250˚C 150˚C 150˚C 150˚C 150˚C 110˚C HIDDEN

SERIOUS EXTERNAL ALARM


LOW TEMPERATURE ALARM
DATA OR MEMORY FAILURE
Ot Thermostat Probe Calibration -12 to 12˚C 0˚C 0˚C 0˚C 0˚C 0˚C FIRST
P2P Evaporator Probe Presence N=Not Present Y=Present not used not used not used y y FIRST
OE Evaporator Probe Calibration -12 to 12˚C not used not used not used 0˚C 0˚C HIDDEN
OdS Outputs Delay at start up 0 to 255 min 0min 0min 0min 0min 0min HIDDEN
AC Anti-Short Cycle delay 0 to 50 min 1min 1min 1min 1min 1min FIRST

EXTERNAL ALARM
CCt Continuous Cycle duration 0.0 to 24.0 hrs not used not used 0hr 0hr 0hr HIDDEN
COn Compressor on time with Faulty Probe 0 to 255 min 30min 15min 15min 15min 15min HIDDEN
COF Compresser off time with Faulty Probe 0 to 255 min 30min 30min 30min 30min 30min HIDDEN
CH Type of Action (cooling or heating) CL = cooling / Ht = heating CL CL CL not used not used FIRST
CF Temperature Measurement Unit ˚C or ˚F ˚C ˚C ˚C ˚C ˚C HIDDEN
rES Resolution dE = dec.point / in = integer dE dE dE dE dE FIRST
Prd Second Probe read out —- not used not used not used used used HIDDEN
tdF Defrost Type EL = electric heater / in = hot gas not used not used not used EL EL FIRST
dtE Defrost Termination Temperature -50 to +50˚C not used not used not used 8˚C 8˚C FIRST
IdF Interval between Defrost Cycles 0 to 120hrs not used 8hrs 8hrs 6hrs 6hrs FIRST
MdF (MAXIMUM) Length for Defrost 0 to 255 min not used 20min 20min 30min 30min FIRST
dFd Displaying during Defrost re=actual / it = defrost start not used it it it it HIDDEN
SEt = setpoint / dEF = ”dEF” lable
dAd MAX Display delay after Defrost 0 to 255 min not used 30min 30min 30min 30min HIDDEN

HA

CA
EE

EA
P1
P2

LA
Fdt Draining time 0 to 120 min not used not used not used 0min 0min HIDDEN
dPo First Defrost after Startup n = normal / y = immediately not used not used not used n n HIDDEN
dAF Defrost delay after fast Freezing 0 to 23 hrs not used not used not used 0hrs 0hrs HIDDEN
Fnc Fan Operation Mode C-n = on & off with comp. & off in defrost not used not used not used not used o-n FIRST
o-n = fan on except in defrost

ALARM SIGNALS
& Fnd parameter fan is off
C-Y = on & off with comp & on during defrost
o-Y = Always on including defrost
Fnd Fan Delay after Defrost 0 to 255 min not used not used not used not used 10min FIRST
FSt Fan Stop Temperature -50 to 50˚C not used not used not used not used 2˚C FIRST
ALc Temperate Alarms Configuration rE =related to setpoint / Ab = absolute Ab Ab Ab Ab Ab HIDDEN
ALU MAXIMUM Temperature Alarm Setpoint to 150˚C 150˚C 150˚C 150˚C 150˚C 110˚C FIRST
ALL MINIMUM Temperature Alarm -50 to Setpoint -50˚C -50˚C -50˚C -50˚C -50˚C FIRST
ALd Temperature Alarm Delay 0 to 255 min 15min 15min 15min 15min 15min HIDDEN
dAO Delay of temperature alarm at start up 0 to 23 hrs 1hr 1.3hrs 1.3hrs 1.3hrs 1.3hrs HIDDEN
tba Alarm Relay Silencing n = no / y = yes not used not used y not used not used HIDDEN
OAC 2nd Relay Configuration Alr = alarm / dEf = not selected / Aus = auxiliary not used not used AUS not used not used FIRST
i1P Digital Input Polarity oP = opening / CL = closing not used not used CL not used CL FIRST
i1F Digital Input Configuration EAL = external alarm / bAL = lock regulate not used not used AUS not used bAL FIRST
dEF = defrost / AUS = aux activated
did Digital Input Alarm Delay 0 to 255 min not used not used 0min not used 0min FIRST
PbC Probe Selection Ptc or ntc (positive or negative temperature codification) ntc ntc ntc ntc not used FIRST
nPS Kind of Action when i1F = bAL 0 = door switch / 1 = lock regulations / not used not used not used not used O HIDDEN
2-15 = pressure switch
rel Manufacturers Warranty Code UNCHANGEABLE not used not used not used not used not used HIDDEN
Ptb Manufacturers Warranty Code UNCHANGEABLE not used not used not used not used not used HIDDEN
rSt Manufacturers Warranty Code UNCHANGEABLE not used not used not used not used not used FIRST
4568 KIRBY Instruction card._tg 23/11/00 5:14 PM Page 2

DIXELL-PRIME SERIES PROGRAMMING

FAN DELAY AFTER DEFROST


ANTI SHORT CYCLE ENABLE
INSTRUCTIONS

( LED1 ALSO FLASHING )


(LED2 ALSO FLASHING)
PROGRAMMING MODE

PROGRAMMING MODE

CONTINUOUS CYCLE
COMPRESSOR RUN

DEFROST ENABLE
XR60
TO LOCK OR UNLOCK KEYPAD

FANS ENABLE
PRESS ▲ + ▼ KEYS UNTILL “PoF” IS DISPLAYED = KEYPAD LOCKED

NOT USED
PRESS ▲ + ▼ KEYS UNTILL “Pon” IS DISPLAYED = KEYPAD UNLOCKED.

TO DISPLAY MIN / MAX TEMPERATURES RECORDS


PRESS & RELEASE ▼ KEY, “Lo” IS DISPLAYED FOLLOWED BY THE
Refrigeration and
ANTI SHORT CYCLE ENABLE

MINIMUM TEMPERATURE RECORDED”

( LED1 ALSO FLASHING )


(LED2 ALSO FLASHING)

PRESS & RELEASE ▲ KEY, “Hi” IS DISPLAYED FOLLOWED BY THE


PROGRAMMING MODE

PROGRAMMING MODE
Air Conditioning

CONTINUOUS CYCLE
COMPRESSOR RUN

MAXIMUM TEMPERATURE RECORDED”


DEFROST ENABLE
XR40

TO RESET HOLD THE SET KEY FOR MORE THAN 3 SECONDS WHILE “Lo”
NOT USED or “Hi” IS DISPLAYED
Specialists
NOT USED

NOT USED
TO CHANGE SETPOINT
PRESS SET KEY & HOLD FOR 3 SECONDS ( COMPESSOR LED STARTS
BLINKING )
ANTI SHORT CYCLE ENABLE

PRESS ▲ OR ▼ BUTTONS TO CHANGE SETPOINT


( LED1 ALSO FLASHING )
(LED2 ALSO FLASHING)
PROGRAMMING MODE

PROGRAMMING MODE

CONTINUOUS CYCLE

DIXELL-
TO CHANGE A PARAMETER VALUE
COMPRESSOR RUN

SECOND RELAY ON
XR30

DEFROST ENABLE

PRESS SET + ▼ BUTTON UNTILL “HY” IS DISPLAYED


PRESS ▲ OR ▼ BUTTON TO SELECT PARAMETER ( see parameter table )
NOT USED

NOT USED

PRESS SET BUTTON


PRESS ▲ OR ▼ BUTTON TO CHANGE SETTING
PRESS SET TO ENTER
PRESS ▲ OR ▼ BUTTONS TO SELECT NEXT PARAMETER AND REPEAT PRIME SERIES
ANTI SHORT CYCLE ENABLE

SETTING PROCEDURE
( LED1 ALSO FLASHING )
(LED2 ALSO FLASHING)
PROGRAMMING MODE

PROGRAMMING MODE

Unit automatically exits setting mode in 15 seconds if no key is pressed or


COMPRESSOR RUN

press set and up buttons


PROGRAMMING
DEFROST ENABLE
XR20

TO ACCESS HIDDEN PARAMETER VALUE


NOT USED

NOT USED

NOT USED

NOT USED

PRESS SET & ▼ BUTTON UNTIL “HY” IS DISPLAYED


RELEASE & PRESS SET & ▼ BUTTONS AGAIN UNTIL “Pr2” IS DISPLAYED
PRESS ▲ OR ▼ BUTTON TO SELECT PARAMETER (see parameter table)
PRESS SET BUTTON INSTRUCTIONS
ANTI SHORT CYCLE ENABLE

PRESS ▲ OR ▼ BUTTON TO CHANGE SETTING


( LED1 ALSO FLASHING )
(LED2 ALSO FLASHING)
PROGRAMMING MODE

PROGRAMMING MODE

PRESS SET TO ENTER


COMPRESSOR RUN

PRESS ▲ OR ▼ BUTTONS TO SELECT NEXT PARAMETER AND REPEAT


XR10

SETTING PROCEDURE
NOT USED

NOT USED

NOT USED

NOT USED

Unit automatically exits setting mode in 15 seconds if no key is pressed or


press set and up buttons
LED FUNCTIONS

THE CONTINUOUS CYCLE


FOR YOUR NEAREST KIRBY OUTLET
FLASHING

FLASHING

FLASHING

PRESS AND HOLD ▲ BUTTON FOR 3 SECONDS (not in defrost mode)


MODE

FREECALL 1800 65 3330 (Aust) OR


ON

ON

ON

ON

ON

continuous cycle activated - time set through “CCt”


PRESS AND HOLD ▲ BUTTON FOR 3 SECONDS continuous cycle terminated
0800 65 3330 (NZ)
For International Enquiries Call
LED1

LED2

LED3

LED4

LED5
LED

TO START A MANUAL DEFROST Sydney Australia +61 2 9774 7155


PUSH TO DEF KEY FOR MORE THAN 2 SECONDS http://www.kirbyrefrig.com.au