Theodolite

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 32

THEODOLITE:

INTRODUCTION
INTRODUCTION
Theodolite is used to measure the horizontal and
vertical angles.

Theodolite is more precise than magnetic compass.

Magnetic compass measures the angle up to as


accuracy of 30. However a vernier theodolite
measures the angles up to and accuracy of 10, 20.

There are variety of theodolite vernier, optic,


electronic etc.
TYPE OF THEODOLITE
Vertical axis
VERNIER THEODOLITE
Traverse/horizontal axis
Vertical circle rigidly fixed to
the telescope

Line of Sight

Alidade assembly
Vernier theodolite is
also known and
transit.
Horizontal circle
assembly
A transit theodolite is
one in which the
Levelling head assembly
telescope can be
rotated in a vertical
plane.
Three assemblies of Theodolite
Main parts of a theodolite
Levelling head (7): Levelling
head is used to attach the
instrument to tripod and attach
the plumb bob along the vertical
axis of the instrument.
MAIN PARTS-2
Lower plate/circle plate (18): an annular
horizontal plate with the graduations
provided all around, from 0 to 360, in a
clockwise direction. The graduations are in
degree divided in to 3 parts so that each
division equals to 20 min.

Horizontal angles are measured with this


plate.

The size of the theodolite is defined by the


diameter of horizontal circle.

Upper plate (17): Horizontal plate of


smaller diameter provided with two verniers.
on diametrically opposite parts of its
circumference. These verniers are designated
as A and B. They are used to read fractions
of the horizontal circle plate graduations.
The verniers are graduated in 20 min and
each minute is divided in 3 to 5 parts making
least count 20 or 10.
MAIN PARTS-3
Clamps and tangent screws (15, 19):
There are two clamps and associated tangent
screws with the plate. These screws facilitate
the motion of the instruments in horizontal
plane.

Lower clamp screw locks or releases the


lower plate. When this screw is unlocked
both upper and lower plates move together.
The associated lower tangent screw allows
small motion of the plate in locked position.

The upper clamp screw locks or releases the


upper vernier plate. When this clamp is
released the lower plate does not move but
the upper vernier plate moves with the
instrument. This causes the change in the
reading. The upper tangent screw allows the
fine adjustment.
MAIN PARTS-4

Plate level (5):


Spirit level with the bubble and
graduation on glass cover.
A single level or two levels fixed in
perpendicular direction may be
provided.
The spirit level can be adjusted with
the foot screw (21) of the levelling
head (7).

Telescope (10): The essential parts of the


telescopes are eye-piece, diaphragm with
cross hairs, object lens and arrangements
to focus the telescope.
MAIN PARTS-5

Vertical circle (1): circular plate


supported on horizontal axis of the
instrument between the A-frames.
Vertical circle has graduation 0-90 in
four quadrants. Vertical circle moves
with the telescope when it is rotated
in the vertical plane.

Vertical circle clamp and tangent


screw (11): Clamping the vertical
circle restrict the movement of
telescope in vertical plane.

Altitude level (2): A highly sensitive


bubble is used for levelling
particularly when taking the vertical
angle observations.
Reading a
theodolite

Vernier scale graduation


Important Definition

Changing face
Revolving the telescope by 180 in vertical plane
about horizontal axis
Again revolving the telescope in horizontal plane
about vertical axis.
Adjustment of the theodolite
Temporary Adjustment

Setting up the theodolite


Measurement of horizontal angle
Measurement of Angle ABC
The instrument is set over B.
The lower clamp is kept fixed and upper clamp is
loosened.
Turn the telescope clockwise set vernier A to 0 and
vernier B to approximately 180.
Upper clamp is tightened and using the upper tangent
screw the vernier A and B are exactly set to 0 and 180.
Upper clamp is tightly fixed, lower one is loosened and
telescope is directed towards A and bisect the ranging
rod at A.
Tightened the lower clamp and turn the lower tangent
screw to perfectly bisect ranging rod at A.
Loose the upper clamp and turn the telescope clockwise
to bisect the ranging rod at C tightened the upper clamp
and do the fine adjustment with upper tangent screw.
The reading on vernier A and B are noted. Vernier A
gives the angle directly and vernier B gives the reading
by subtracting the initial reading (180) from final
reading
Read these two method
Repetition method
Reiteration method
Vertical angle measurement-1
Vertical angle measurement-2
Measurements of
Deflection angle
P
magnetic bearing
B

N
B C

A
Read assignment (N. N. Basak, S. K. Duggal)
Ranging and extending a line

Method of traversing
Included angle method
Deflection angle method
Fast angle (or magnetic bearing method)
Computation of latitude and departure
Latitude of a line is the distances measured
parallel to the north south of the North-South
direction
Departure of the line is the distance measured

parallel to the east-west direction


Computing latitude and departure
PROBLEM-1
While making survey through the woods, a surveyor with the hand
compass started from point A and walked a thousand steps in the direction
S67W and reached a point B. then he changed his direction and walked
512 steps in the direction N10E and reached a point C then again he
changed his direction and walked 15 04 steps in the direction S65E and
reached a point D as shown in Figure Now the surveyor wants to return to
the starting point A. In which direction should he move and how many
steps should he take.
Sources of errors in theodolite
Instrumental errors
Non adjustment of plate bubble
Line of collimation not being perpendicular to
horizontal axis
Horizontal axis not being perpendicular to vertical
axis
Line of collimation not being parallel to axis of
telescope
Eccentricity of inner and outer axes
Graduation not being uniform
Verniers being eccentric
. Personal errors
Natural errors
High temperature causes error due to irregular refraction.
High winds cause vibration in the instrument, and this may
lead to wrong readings on verniers
Closing error
Balancing of traverse
Bowditchs rule:
Total error is distributed in proportion to the lengths of the
traverse legs.
Calculation of traverse area
PROBLEM
Calculate the latitudes, departures and closing
error for the following traverse conducted at
allahabad. Adjust also the traverse using
Bowditchs rule.

Line Length WCB


AB 89.31 45 10
BC 219.76 72 05
CD 151.18 161 52
DE 159.10 228 43
EA 232.26 300 42