Design of Embedded Zigbee Machine To Machine Smart
Design of Embedded Zigbee Machine To Machine Smart
Design of Embedded Zigbee Machine To Machine Smart
0
LDR1
D1
LED-RED
www.TheEngineeringProjects.com
TestPin
R1
2 1
10k
TORCH_LDR
ARD1
www.TheEngineeringProjects.com
AREF
13
PB5/SCK
PB4/MISO
12 PIR1
RESET 11 PIR SENSOR
~ PB3/MOSI/OC2A
10
~ PB2/OC1B
9
~ PB1/OC1A
8
PB0/ICP1/CLKO
RXD
ATMEGA328P-PU
1121
PD7/AIN1
6 TXD
A0 ~ PD7/AIN1
5
PC0/ADC0
A1 ~ PD5/T1/OC0B
4
PC1/ADC1 RTS
A2 PD4/T0/XCK
3
PC2/ADC2 Xmodem, Ymodem, Zmodem
A3 ~ PD3/INT1/OC2B
2
PC3/ADC3 PD2/INT0
CTS
A4 1
PC4/ADC4/SDA PD1/TXD
A5 0
PC5/ADC5/SCL PD0/RXD
ARDUINO UNO
• Result of testing of light dimmer
• Zigbee device communication testing
• Received Signal Strength Indicator (RSSI)
• in barrier area
• In loss area
• Testing of zigbee topology
• OMNET ++ as simulator tool
• Performance testing consists
• throughput measurement
• packet delay
• two possible topology such as
• direct transmission between the coordinator and the End Device;
• transmission through Router
• zigbee device in point to point link at different baud rate
• 10 bytes to 80 bytes every 5 second
• performance test on a larger area using a router
Conclusion
• The development of zigbee embedded devices through
dimmer control based on object detection and
environmental conditions and the use of environmental
sensors enables control of electrical equipment
automatically
• The maximum distance reached is 30 meters for the
barrier area and 60 meters for the area without obstacles
• The minimum power level must be reached for real-time
communication is -85dBm to -90dBm with less than
150ms delay
• direct configuration is better than using a router. So that,
on configuration via router, the number of transmitting
nodes should be minimized
Acknowledgment
• We would like to thank to Semarang State University
(UNNES) for their assistance in facilitating research.
References
[1] "ESDM," 2014. [Online]. Available: http://www.esdm.go.id/siaran-pers/55-
siaran-pers/6671-peresmian-pilot-project-penerangan-jalan-umum-pju-pintar-
di-6-kota-dan-jembatan-suramadu.html.
[2] N. Sahu, "Intelligent Machine to machine communication in Home area
network for Smart grid," in ICCCNT, India, 2012.
[3] G. Suciu, "Machine-to-Machine Communications for Cloud Based Energy
Management," in International Symposium for Design and Technology in
Electronic Packaging, Romania, 2016.
[4] K. Kamel, "On Design of M2M Smart Energy Control and Managemant
Architecture Using Smart Matering Technology," 2016.
[5] Z. Wang, "Smart Home M2M Networks Architecture," in International
Conference on Mobile Ad-hoc and Sensor Networks, 2013.
[6] D. Niyato, "Machine-to-Machine Communications for Home Energy
Management System in Smart Grid," in IEEE Communications Magazine,
2011.
[7] Zubair, "Toward Intelligent Machine-to Machine Communications in Smart
Grid,"in IEEE Communications Magazine, 2011.
[8] R. Piyare and S.-r. Lee, "Performance Analysis of XBee ZB Module Based
Wireless Sensor Networks," International Journal of Scientific & Engineering
Research, vol. 4, no. 5, 2013.