What is impact testing?
The impact test is a method for evaluating the toughness, impact
strength and notch sensitivity of engineering materials.
It is usually used to test the toughness of metals, but similar tests
are used for polymers, ceramics and composites.
The notched test specimen is broken by the impact of a heavy
pendulum or hammer, falling at a predetermined velocity through a
fixed distance.
The test measures the energy absorbed by the fractured specimen.
Why impact testing is important?
Impact test determines the amount of energy absorbed by a
material during fracture.
This absorbed energy is a measure of a given material's
toughness
Acts as a tool to study temperature-dependent brittle-ductile
transition.
It is to determine whether the material is brittle or ductile in
nature.
The types of impact tests
There are basically two types of impact tests:
A. Pendulum B. Drop Weight
A. Pendulum:
Izod and Charpy are the most common of the pendulum type tests.
B. Drop Weight
A mass is dropped vertically on to a test specimen.
A tube or rails are used to guide the falling mass.
Since the mass either stops dead on the specimen or
breaks it, the test was essentially pass/fail.
This equipment is mainly designed to check the impact
failure weight of films and sheeting by a falling weight
impact method.
What is impact testing machine?
pendulum(1J,2.75J,11J,22J),
pendulum(1J, 2.75J), pendulum pendulum(11J, 22J), vice
Standard Accessories weight (5.5J), vice adjusting
weight (5.5J), vice adjusting plate, adjusting plate, spanner, power
(For Izod) plate, spanner, power cord,
spanner, power cord, manual etc. cord, manual etc.
manual etc.
DROP DART (FREE-FALLING DART) IMPACT TESTER
Model XJB-30
A method: R19±1mm (2 pcs)
Dart weight
B method: 25±1mm (1 pc)
50—2000g (5g increment)
Weight 5g (5 pcs), 15g (15 pcs), 30g (10 pcs),
45g (10 pcs), 60g (10 pcs), 90g (15 pcs)
Specimen clamper OD 150mm, ID 125mm
Max. energy 30J
Impact height 1500mm
Power 220V, 50HZ
Dimensions 650mm×650mm×2600mm
Weight 150Kg
Standard Accessories Loadframe, Dart head, weight unit, tools, power cord, manual etc.
Model XJL-300
Hammer weight 0.250—16.000kg (0.125 increment)
Working bench stroke 0—400mm (630mm)
Specimen diameter φ10—φ400mm (more big is available)
Radius of hammer head D25, D90
Impact height 2000mm
Height position error ±2mm
Power 220V, 50HZ
Display type Digital display
Dimensions 700mm×700mm×3300mm
Weight 450Kg
Load frame, Electronic control box, hammer block,
Standard Accessories
power cord, manual etc.
Standard ISO 3127, ASTM D2444, DIN-EN 744, BS-EN 1411
International equipments Co.
Analog Izod / Charpy Impact Tester
Specification:
• Capacity : Up to 21.68 Joules.
• Release angle of pendulum: 150 degree.
• Range of four scales : 0-2.71 Joules, 0-5.42 Joules,
0-10.84 Joules and 0-21.68 Joules
• Minimum resolution on scale :0.02 Joule, 0.05
Joule, 0.1 Joule and 0.2 Joule respectively.
• Paint : Powder coated.
Specification:
• Capacity : Up to 25.00 Joules.
• Release angle of pendulum: 150 degree.
• Range of four scales : 0-2.71 Joules, 0-5.42 Joules, 0-10.84 Joules,
0-21.68 Joules and 0-25.00 Joules.
• Minimum resolution on scale : 0.02 Joule, 0.05 Joule, 0.1 Joule,
0.2 Joule and 0.2 Joule respectively.
• Paint : Powder coated.
• Power : 230 Volts, 50 Hz, single phase.
• Direct display through microcontroller : Impact strength in
joules/meter and kg-cm/cm.
Specification:
• Dart : 2 nos.
• Release mechanism : Electromagnetic.
• Vacuum creation : Single stage oil vacuum pump.
• Paint : Powder coated.
• Power : 230Volts, 50Hz, single phase.
• Weights : A set of weights ranging from 5 grams to 500 grams
would be supplied for incremental loads.
Specification:
• Dart : 2 nos.
• Release mechanism : Electromagnetic.
• Vacuum creation : Single stage oil vacuum pump.
• Paint : Powder coated.
• Power : 230Volts, 50Hz, single phase.
• Weights : A set of weights ranging from 5 grams to 500 grams
would be supplied for incremental loads.
walter+ bai Testing Machine
TECHLAB SYSTEMS, S.L.
USA Office/Sales/Customer Service
TECHLAB SYSTEMS S.L. - 1549 W. Ardmore Ave. Itasca- IL 60143 - USA
(Phone: 630-595-8810 Fax: 630-595-5196)
EUROPEAN Office/Sales/Customer Service
TECHLAB SYSTEMS S.L. - C/ Txatxamendi Nº 10 - Polígono Industrial Nº110 -
20100 Lezo - SPAIN (Phone: +34 943 44 43 00)
“CHARPY-IZOD” PENDULUM IMPACT TESTER
Model PIT-25
Impact energy range O to 25 joules
Reading resolution 0,001 J and 0,1 KJ/ m2
Release angle of Impact Hammer 150º
Speeds Charpy Impact Hammers
2.9m/s
0.5-1-2-4-5 with J
Impact speeds with the rest of
3.8 m/s
hammers Charpy and Izod
Height position error ±2mm
Power 220/110V, Single Phase, 50 or 60 HZ
Display type Digital display
Dimensions(WxDxH) 1000mm×446mm×940mm
Weight 200Kg
Load frame, Electronic control box, hammer block, power
Standard Accessories
cord, manual etc.
ASTM D256/A, ASTM D256/B, ASTM D4812, ASTM D6110, DIN
Standard
179-1, DIN 180, EN 179-1, EN 180, ISO 179-1, ISO 180
Free Falling Drop Weight Impact Tester
Model FIT2000A
Maximum impact capacity 16 Kg of mass from 2 meters high.
Maximum magnet energy 300 Joules
Base supports 20 and 630 mm
Power 220/110V, Single Phase, 50 or 60 HZ
Display type Digital display
Dimensions(WxDxH) 800 x 610 x 3600 mm
Weight 260 Kg
Impact Tests in Plastic Tubes, plastic pipes, PVC pipes, high
Basic Applications
density polyethylene pipes, low density polyethylene pipes
Standard ASTM D2444, DIN 11173, EN 11173, ISO 11173, ISO 3127
ZwickRoell USA, USA
2125 Barrett Park Drive, Suite 107
30144 Kennesaw, GA, USA
Tel.: +1 770 420 6555
Fax: +1 770 420 6333
https://www.zwickroell.com/en-us
Drop Weight Testers up to 2000 Joules
Qualitest - Advanced Testing Technologies
https://www.worldoftest.com
High Performance Charpy / Izod Impact Tester- Q-Impact 50
Specifications Izod Testing Charpy Testing
Energy levels (max capacity) 5.5J, 11J, 22J 7.5J, 15J, 25J, 50J
ASTM D256,
Span of Charpy - 62mm
Impact Speed 3.5m/s 3.8m/s
ASTM D6110, ISO
Radius of striking edge R=0.8mm±0.2mm R=2mm±0.5mm 179, ISO 180
Location of striking edge above top 22mm±0.05mm
surface of support
Notch A 45º±1º 45º±1º
Radius of the notch bottom R=0.25±0.05mm R=0.25±0.05mm
Notch B 45º±1º 45º±1º
Radius of the notch bottom R=1±0.05mm R=1±0.05mm
Notch C 45º±1º
Radius of the notch bottom R=0.10±0.02mm
Angle of striking edge 30°±1°
Measurement resolution 0.01J
Dimension: 1280X880X1300mm
Gross weight: 100kg (220lb)
Digital Charpy/Izod Impact Tester - Q-Impact 5
Specifications Izod Testing Charpy Testing
Energy levels (max capacity) 2.75J, 5.5J 0.5J, 1.0J, 2.0J, 4.0J, 5.0J
ASTM D256, ASTM
Span of Charpy - 62mm D6110, ISO 179, ISO
Impact Speed 3.5m/s 2.9 m/s 180
Radius of striking edge R = 0.8mm ± 0.2mm R = 2mm ± 0.5mm
Location of striking edge above top 22 mm ± 0.05mm
surface of support
Notch A 45º ± 1º 45º ± 1º
Radius of the notch bottom R = 0.25 ± 0.05mm R = 0.25 ± 0.05mm
Notch B 45º±1º 45º ± 1º
Radius of the notch bottom R=1±0.05mm R=1 ± 0.05mm
Notch C 45º±1º
Radius of the notch bottom R=0.10 ± 0.02mm
Angle of striking edge 30° ± 1°
Measurement resolution 0.01J
Dimension: 1280X880X1300mm
Gross weight: 100kg (220lb)
Analog Izod / Charpy Impact Tester - QPI-IC
Model QPI-IC-12J Universal Impact Tester / QPI-IC-21J Universal Impact Tester
Test Type IZOD &CHARPY
ASTM D256,
Start impact Angle 150° ISO 180
- Radius of striker edge 0.8 mm
IZOD - Grip border distance strike point 22 mm
- Impact velocity:3.47 m/sec
ASTM ISO