KVMG Lecture
KVMG Lecture
KVMG Lecture
New Solar V
Effective Model
-S225LC-V -(S420LC-V)
-S255LC-V -(S450LC-V)
-S300LC-V -(S470LC-V)
-S340LC-V
Schematic Diagram DHIM C/S
Denomination DHIM C/S
Negacon Pressure
Pump Flow
Spool Stroke
Spool C
Spool B
Spool A
Why Parallel?
Oil Lines DHIM C/S
▶ Pilot (PA, PT) Line (1/2)
▷ Case 1 : All Neutral
P5
▷ Case 2 : E or F switched
P4
▷ Case 3 : C switched
▷ Case 4 : D switched
P3 P2 ▷ Case 5 : (E or F) + C switched
P1 ▷ Case 6 : (E or F) + D switched
▷ Case 7 : (E or F) + (C and D) switched
Case P1 P2 P3 P4 P5 S1 S2 TS
Case 1 40 0 0 0 0 open open neutral
Case 2
Case 3
Case 4
Case 5
Case 6
Case 7
Oil Lines DHIM C/S
▶ Pilot (PA, PT) Line (2/2)
▷ Function of PA pressure
1) Auto Idle
2) Travel Straight
3) Swing brake release
(SH)
▷ Function of PT pressure
1) Auto Idle
2) Travel Straight
▷ Drain Line
▷ Return Line
▷ Center bypass
bleed off
Functions DHIM C/S
▶ Arm Crowd
P P
▷ P is high ▷ P is Low
☞ Question
What if Regeneration Function does not work properly ?
Break DHIM C/S
Functions DHIM C/S
ARM 1 BOOM 1
With Swing
pilot signal
BOOM 2
BUCKET
With Boom up
pilot signal
SWING
Functions DHIM C/S
▶ Travel Straight
▷ Working Condition
BOOM 2 BOOM 1
- Both Travels + Front
(High PT & PA pressure)
OPTION TRAVEL
▷ What if an orifice is
blocked?
Functions DHIM C/S
▶ Load Check Valves
Opening Area
P→C P→Cyl
Cyl→T
Spool Stroke
▷ If the load check allows counter directional oil flow because of wearing
or breakage, what happens?
Functions DHIM C/S
▶ Load Check Valves (continued)
In BP
Question DHIM C/S
Was it Intere
sting?
Oil Lines DHIM C/S
▶ Pilot Line (Answer)
▷ Case 1 : All Neutral
P5
▷ Case 2 : E or F switched
P4
▷ Case 3 : C switched
▷ Case 4 : D switched
P3 P2 ▷ Case 5 : (E or F) + C switched
P1 ▷ Case 6 : (E or F) + D switched
▷ Case 7 : (E or F) + (C and D) switched
Case P1 P2 P3 P4 P5 S1 S2 TS
Case 1 40 0 0 0 0 open open neutral
Case 2 40 40 0 0 0 close open neutral
Case 3 40 0 40 0 0 open close neutral
Case 4 40 0 40 0 0 open close neutral
Case 5 40 40 40 0 0 close close neutral
Case 6 40 40 40 0 0 close close neutral
Case 7 40 40 40 40 0 close close switched