Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

RAS 12 Tanks

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 5

Aquaculture Production Assignment - Equipment & Systems

Design a Tilapia
growout RAS
Member of group 5

1. ADJAFFON H. Boniface

2. ADJE Béatrice Ranti-Oluwa


Lecturer

3. HOUEHOUME GANSE Curie P.S.


M. Leslie

4. KPOCLOU Kokou Christophe Géoffroy

5. MITOBABA Jean-Baptiste Aurel G.

6. SOGLO Davys
COMPONENTS OF SYSTEM

• Fish Tanks, MFs, BFs


Numbers Diameter Water depth Capacity (each) Total
(m) (m) capacity

Fish Tanks 12 4 1.2 15.07 m3 180,86 m3


Radial clarifier 1 3.3 1.2 16.66 m² 16.66 m²
Mechanical 2 3.3 1.2 8.33 m² 16.66 m²
filter
Biofilter 2 2.8 1.2 7.23 m3 14.46 m3

 Mechanical filter  Biofilter


Flow rate : 12 m/hr Feed rqd: 20 kg/m3 * 181 m3 * 2% = 72 kg
Flow achieved by pump : 200 m3/hr BF media rqd : 72 kg ÷ 10 kg/m3 = 7.2 m3
MFs surface aera rqd BF volume : 7.2 m3 * 2 = 14.4 m3
200 ÷ 12 = 16,6 m²
COMPONENTS OF SYSTEM

• Pump
Water exchange = 1×/hr Numbers Capacity Total achieved Total Kw
(each) m3/hr m3/hr
Pump rqd: 180,86 * 1 = 180,86
Pump 4 50 200 2
m /hr
3

Blower 2 130 260 3


• Blower
- Aeration rqd for Biofilter
10 m3/hr/m² * 6 m²(surface area/BFs) * 2 (number of BFs) = 120 m3/hr
- Aeration rqd for fish tanks
4 diffusers/tank ; diffuser = 2.2 m3/hr/m²
2.2 * 4 * 12 = 105.6 m3/hr
Total aeration rqd : 121 + 105.6 = 226.6 m3/hr