-
Technical Design Report for the LUXE Experiment
Authors:
H. Abramowicz,
M. Almanza Soto,
M. Altarelli,
R. Aßmann,
A. Athanassiadis,
G. Avoni,
T. Behnke,
M. Benettoni,
Y. Benhammou,
J. Bhatt,
T. Blackburn,
C. Blanch,
S. Bonaldo,
S. Boogert,
O. Borysov,
M. Borysova,
V. Boudry,
D. Breton,
R. Brinkmann,
M. Bruschi,
F. Burkart,
K. Büßer,
N. Cavanagh,
F. Dal Corso,
W. Decking
, et al. (109 additional authors not shown)
Abstract:
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger fiel…
▽ More
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger field and beyond. The further implications for the search of physics beyond the Standard Model are also discussed.
△ Less
Submitted 2 August, 2023; v1 submitted 1 August, 2023;
originally announced August 2023.
-
The Forward Physics Facility at the High-Luminosity LHC
Authors:
Jonathan L. Feng,
Felix Kling,
Mary Hall Reno,
Juan Rojo,
Dennis Soldin,
Luis A. Anchordoqui,
Jamie Boyd,
Ahmed Ismail,
Lucian Harland-Lang,
Kevin J. Kelly,
Vishvas Pandey,
Sebastian Trojanowski,
Yu-Dai Tsai,
Jean-Marco Alameddine,
Takeshi Araki,
Akitaka Ariga,
Tomoko Ariga,
Kento Asai,
Alessandro Bacchetta,
Kincso Balazs,
Alan J. Barr,
Michele Battistin,
Jianming Bian,
Caterina Bertone,
Weidong Bai
, et al. (211 additional authors not shown)
Abstract:
High energy collisions at the High-Luminosity Large Hadron Collider (LHC) produce a large number of particles along the beam collision axis, outside of the acceptance of existing LHC experiments. The proposed Forward Physics Facility (FPF), to be located several hundred meters from the ATLAS interaction point and shielded by concrete and rock, will host a suite of experiments to probe Standard Mod…
▽ More
High energy collisions at the High-Luminosity Large Hadron Collider (LHC) produce a large number of particles along the beam collision axis, outside of the acceptance of existing LHC experiments. The proposed Forward Physics Facility (FPF), to be located several hundred meters from the ATLAS interaction point and shielded by concrete and rock, will host a suite of experiments to probe Standard Model (SM) processes and search for physics beyond the Standard Model (BSM). In this report, we review the status of the civil engineering plans and the experiments to explore the diverse physics signals that can be uniquely probed in the forward region. FPF experiments will be sensitive to a broad range of BSM physics through searches for new particle scattering or decay signatures and deviations from SM expectations in high statistics analyses with TeV neutrinos in this low-background environment. High statistics neutrino detection will also provide valuable data for fundamental topics in perturbative and non-perturbative QCD and in weak interactions. Experiments at the FPF will enable synergies between forward particle production at the LHC and astroparticle physics to be exploited. We report here on these physics topics, on infrastructure, detector, and simulation studies, and on future directions to realize the FPF's physics potential.
△ Less
Submitted 9 March, 2022;
originally announced March 2022.
-
Conceptual Design Report for the LUXE Experiment
Authors:
Halina Abramowicz,
Uwe Hernandez Acosta,
Massimo Altarelli,
Ralph Assmann,
Zhaoyu Bai,
Ties Behnke,
Yan Benhammou,
Thomas Blackburn,
Stewart Boogert,
Oleksandr Borysov,
Maryna Borysova,
Reinhard Brinkmann,
Marco Bruschi,
Florian Burkart,
Karsten Büßer,
Niall Cavanagh,
Oz Davidi,
Winfried Decking,
Umberto Dosselli,
Nina Elkina,
Alexander Fedotov,
Miroslaw Firlej,
Tomasz Fiutowski,
Kyle Fleck,
Mikhail Gostkin
, et al. (66 additional authors not shown)
Abstract:
This Conceptual Design Report describes LUXE (Laser Und XFEL Experiment), an experimental campaign that aims to combine the high-quality and high-energy electron beam of the European XFEL with a powerful laser to explore the uncharted terrain of quantum electrodynamics characterised by both high energy and high intensity. We will reach this hitherto inaccessible regime of quantum physics by analys…
▽ More
This Conceptual Design Report describes LUXE (Laser Und XFEL Experiment), an experimental campaign that aims to combine the high-quality and high-energy electron beam of the European XFEL with a powerful laser to explore the uncharted terrain of quantum electrodynamics characterised by both high energy and high intensity. We will reach this hitherto inaccessible regime of quantum physics by analysing high-energy electron-photon and photon-photon interactions in the extreme environment provided by an intense laser focus. The physics background and its relevance are presented in the science case which in turn leads to, and justifies, the ensuing plan for all aspects of the experiment: Our choice of experimental parameters allows (i) effective field strengths to be probed at and beyond the Schwinger limit and (ii) a precision to be achieved that permits a detailed comparison of the measured data with calculations. In addition, the high photon flux predicted will enable a sensitive search for new physics beyond the Standard Model. The initial phase of the experiment will employ an existing 40 TW laser, whereas the second phase will utilise an upgraded laser power of 350 TW. All expectations regarding the performance of the experimental set-up as well as the expected physics results are based on detailed numerical simulations throughout.
△ Less
Submitted 27 July, 2021; v1 submitted 3 February, 2021;
originally announced February 2021.
-
PYG4OMETRY: a Python library for the creation of Monte Carlo radiation transport physical geometries
Authors:
Stewart Boogert,
Andrey Abramov,
Laurence Nevay,
William Shields,
Stuart Walker
Abstract:
Creating and maintaining computer readable geometries for use in Monte Carlo Radiation Transport (MCRT) simulations is an error-prone and time-consuming task. Simulating a system often requires geometry from different sources and modelling environments, including a range of MCRT codes and computer-aided design (CAD) tools. PYG4OMETRY is a Python library that enables users to rapidly create, manipu…
▽ More
Creating and maintaining computer readable geometries for use in Monte Carlo Radiation Transport (MCRT) simulations is an error-prone and time-consuming task. Simulating a system often requires geometry from different sources and modelling environments, including a range of MCRT codes and computer-aided design (CAD) tools. PYG4OMETRY is a Python library that enables users to rapidly create, manipulate, display, read and write Geometry Description Markup Language (GDML)-based geometry used in simulations. PYG4OMETRY provides importation of CAD files to GDML tessellated solids, conversion of GDML geometry to FLUKA and conversely from FLUKA to GDML. The implementation of PYG4OMETRY is explained in detail along with small examples. The paper concludes with a complete example using most of the PYG4OMETRY features and a discussion of extensions and future work.
△ Less
Submitted 28 March, 2021; v1 submitted 2 October, 2020;
originally announced October 2020.
-
The Laser-hybrid Accelerator for Radiobiological Applications
Authors:
G. Aymar,
T. Becker,
S. Boogert,
M. Borghesi,
R. Bingham,
C. Brenner,
P. N. Burrows,
T. Dascalu,
O. C. Ettlinger,
S. Gibson,
T. Greenshaw,
S. Gruber,
D. Gujral,
C. Hardiman,
J. Hughes,
W. G. Jones,
K. Kirkby,
A. Kurup,
J-B. Lagrange,
K. Long,
W. Luk,
J. Matheson,
P. McKenna,
R. Mclauchlan,
Z. Najmudin
, et al. (15 additional authors not shown)
Abstract:
The `Laser-hybrid Accelerator for Radiobiological Applications', LhARA, is conceived as a novel, uniquely-flexible facility dedicated to the study of radiobiology. The technologies demonstrated in LhARA, which have wide application, will be developed to allow particle-beam therapy to be delivered in a completely new regime, combining a variety of ion species in a single treatment fraction and expl…
▽ More
The `Laser-hybrid Accelerator for Radiobiological Applications', LhARA, is conceived as a novel, uniquely-flexible facility dedicated to the study of radiobiology. The technologies demonstrated in LhARA, which have wide application, will be developed to allow particle-beam therapy to be delivered in a completely new regime, combining a variety of ion species in a single treatment fraction and exploiting ultra-high dose rates. LhARA will be a hybrid accelerator system in which laser interactions drive the creation of a large flux of protons or light ions that are captured using a plasma (Gabor) lens and formed into a beam. The laser-driven source allows protons and ions to be captured at energies significantly above those that pertain in conventional facilities, thus evading the current space-charge limit on the instantaneous dose rate that can be delivered. The laser-hybrid approach, therefore, will allow the vast ``terra incognita'' of the radiobiology that determines the response of tissue to ionising radiation to be studied with protons and light ions using a wide variety of time structures, spectral distributions, and spatial configurations at instantaneous dose rates up to and significantly beyond the ultra-high dose-rate `FLASH' regime.
It is proposed that LhARA be developed in two stages. In the first stage, a programme of in vitro radiobiology will be served with proton beams with energies between 10MeV and 15MeV. In stage two, the beam will be accelerated using a fixed-field accelerator (FFA). This will allow experiments to be carried out in vitro and in vivo with proton beam energies of up to 127MeV. In addition, ion beams with energies up to 33.4MeV per nucleon will be available for in vitro and in vivo experiments. This paper presents the conceptual design for LhARA and the R&D programme by which the LhARA consortium seeks to establish the facility.
△ Less
Submitted 31 May, 2020;
originally announced June 2020.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
BDSIM: An Accelerator Tracking Code with Particle-Matter Interactions
Authors:
Laurence Nevay,
Jochem Snuverink,
Andrey Abramov,
Lawrence Deacon,
Hector Garcia-Morales,
Stephen Gibson,
Regina Kwee-Hinzmann,
Helena Lefebvre,
William Shields,
Stuart Walker,
Stewart Boogert
Abstract:
Beam Delivery Simulation (BDSIM) is a program that simulates the passage of particles in a particle accelerator. It uses a suite of standard high energy physics codes (Geant4, ROOT and CLHEP) to create a computational model of a particle accelerator that combines accurate accelerator tracking routines with all of the physics processes of particles in Geant4. This unique combination permits radiati…
▽ More
Beam Delivery Simulation (BDSIM) is a program that simulates the passage of particles in a particle accelerator. It uses a suite of standard high energy physics codes (Geant4, ROOT and CLHEP) to create a computational model of a particle accelerator that combines accurate accelerator tracking routines with all of the physics processes of particles in Geant4. This unique combination permits radiation and detector background simulations in accelerators where both accurate tracking of all particles is required over long range or over many revolutions of a circular machine, as well as interaction with the material of the accelerator.
△ Less
Submitted 5 February, 2020; v1 submitted 31 August, 2018;
originally announced August 2018.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Laser Wire Scanner Compton Scattering Techniques for the Measurement of the Transverse Beam Size of Particle Beams at Future Linear Colliders
Authors:
I. Agapov,
K. Baleski,
G. A. Blair,
J. Bosser,
H. H. Braun,
E. Bravin,
G. Boorman,
S. T. Boogert,
J. Carter,
E. D'amico,
N. Delerue,
D. F. Howell,
S. Doebert,
C. Driouichi,
J. Frisch,
K. Honkavaaram S. Hutchins,
T. Kamps,
T. Lefevre,
H. Lewin,
T. Paris,
F. Poirier,
M. T. Price,
R. Maccaferi,
S. Malton,
G. Penn
, et al. (9 additional authors not shown)
Abstract:
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).
△ Less
Submitted 9 December, 2014;
originally announced December 2014.
-
Laserwire at the Accelerator Test Facility 2 with Sub-Micrometre Resolution
Authors:
L. J. Nevay,
S. T. Boogert,
P. Karataev,
K. Kruchinin,
L. Corner,
D. F. Howell,
R. Walczak,
A. Aryshev,
J. Urakawa,
N. Terunuma
Abstract:
A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 μm (vertical x horizontal) electron beam at the laserwire location, which was profiled using a 150 mJ, 71 ps laser pulse with a wavelength of 532 nm. The precise characterisation…
▽ More
A laserwire transverse electron beam size measurement system has been developed and operated at the Accelerator Test Facility 2 (ATF2) at KEK. Special electron beam optics were developed to create an approximately 1 x 100 μm (vertical x horizontal) electron beam at the laserwire location, which was profiled using a 150 mJ, 71 ps laser pulse with a wavelength of 532 nm. The precise characterisation of the laser propagation allows the non-Gaussian transverse profiles of the electron beam caused by the laser divergence to be deconvolved. A minimum vertical electron beam size of 1.07 ${\pm}$ 0.06 (stat.) ${\pm}$ 0.05 (sys.) μm was measured. A vertically focussing quadrupole just before the laserwire was varied whilst making laserwire measurements and the projected vertical emittance was measured to be 82.56 ${\pm}$ 3.04 pm rad.
△ Less
Submitted 29 May, 2014; v1 submitted 1 April, 2014;
originally announced April 2014.
-
Principal Component Analysis of Cavity Beam Position Monitor Signals
Authors:
Y. I. Kim,
S. T. Boogert,
Y. Honda,
A. Lyapin,
H. Park,
N. Terunuma,
T. Tauchi,
J. Urakawa
Abstract:
Model-independent analysis (MIA) methods are generally useful for analysing complex systems in which relationships between the observables are non-trivial and noise is present. Principle Component Analysis (PCA) is one of MIA methods allowing to isolate components in the input data graded to their contribution to the variability of the data. In this publication we show how the PCA can be applied t…
▽ More
Model-independent analysis (MIA) methods are generally useful for analysing complex systems in which relationships between the observables are non-trivial and noise is present. Principle Component Analysis (PCA) is one of MIA methods allowing to isolate components in the input data graded to their contribution to the variability of the data. In this publication we show how the PCA can be applied to digitised signals obtained from a cavity beam position monitor (CBPM) system on the example of a 3-cavity test system installed at the Accelerator Test Facility 2 (ATF2) at KEK in Japan. We demonstrate that the PCA based method can be used to extract beam position information, and matches conventional techniques in terms of performance, while requiring considerably less settings and data for calibration.
△ Less
Submitted 3 March, 2014; v1 submitted 18 November, 2013;
originally announced November 2013.
-
Cavity beam position monitor system for the Accelerator Test Facility 2
Authors:
Y. I. Kim,
R. Ainsworth,
A. Aryshev,
S. T. Boogert,
G. Boorman,
J. Frisch,
A. Heo,
Y. Honda,
W. H. Hwang,
J. Y. Huang,
E. -S. Kim,
S. H. Kim,
A. Lyapin,
T. Naito,
J. May,
D. McCormick,
R. E. Mellor,
S. Molloy,
J. Nelson,
S. J. Park,
Y. J. Park,
M. Ross,
S. Shin,
C. Swinson,
T. Smith
, et al. (4 additional authors not shown)
Abstract:
The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electro…
▽ More
The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the ATF2 diagnostics. Two types of cavity BPMs are used, C-band operating at 6.423 GHz, and S-band at 2.888 GHz with an increased beam aperture. The cavities, electronics, and digital processing are described. The resolution of the C-band system with attenuators was determined to be approximately 250 nm and 1 m for the S-band system. Without attenuation the best recorded C-band cavity resolution was 27 nm.
△ Less
Submitted 23 January, 2013;
originally announced January 2013.
-
Present status and first results of the final focus beam line at the KEK Accelerator Test Facility
Authors:
P. Bambade,
M. Alabau Pons,
J. Amann,
D. Angal-Kalinin,
R. Apsimon,
S. Araki,
A. Aryshev,
S. Bai,
P. Bellomo,
D. Bett,
G. Blair,
B. Bolzon,
S. Boogert,
G. Boorman,
P. N. Burrows,
G. Christian,
P. Coe,
B. Constance,
Jean-Pierre Delahaye,
L. Deacon,
E. Elsen,
A. Faus-Golfe,
M. Fukuda,
J. Gao,
N. Geffroy
, et al. (69 additional authors not shown)
Abstract:
ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, Europe…
▽ More
ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.
△ Less
Submitted 5 July, 2012;
originally announced July 2012.
-
Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider
Authors:
A. Lyapin,
H. J. Schreiber,
M. Viti,
C. Adolphsen,
R. Arnold,
S. Boogert,
G. Boorman,
M. V. Chistiakova,
F. Gournaris,
V. Duginov,
C. Hast,
M. D. Hildreth,
C. Hlaing,
F. Jackson,
O. Khainovsky,
Yu. G. Kolomensky,
S. Kostromin,
K. Kumar,
B. Maiheu,
D. McCormick,
D. J. Miller,
N. Morozov,
T. Orimoto,
E. Petigura,
M. Sadre-Bazzaz
, et al. (7 additional authors not shown)
Abstract:
The International Linear Collider and other proposed high energy e+ e- machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 1e-4. This article presents the analysis of data from a prototype energy spectromete…
▽ More
The International Linear Collider and other proposed high energy e+ e- machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 1e-4. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006--2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5e-4 was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.
△ Less
Submitted 27 January, 2011; v1 submitted 1 November, 2010;
originally announced November 2010.
-
Polarimeters and Energy Spectrometers for the ILC Beam Delivery System
Authors:
S. Boogert,
A. F. Hartin,
M. Hildreth,
D. Käfer,
J. List,
T. Maruyama,
K. Mönig,
K. C. Moffeit,
G. Moortgat-Pick,
S. Riemann,
H. J. Schreiber,
P. Schüler,
E. Torrence,
M. Woods
Abstract:
Any future high energy e+e- linear collider aims at precision measurements of Standard Model quantities as well as of new, not yet discovered phenomena. In order to pursue this physics programme, excellent detectors at the interaction region have to be complemented by beam diagnostics of unprecedented precision. This article gives an overview of current plans and issues for polarimeters and ener…
▽ More
Any future high energy e+e- linear collider aims at precision measurements of Standard Model quantities as well as of new, not yet discovered phenomena. In order to pursue this physics programme, excellent detectors at the interaction region have to be complemented by beam diagnostics of unprecedented precision. This article gives an overview of current plans and issues for polarimeters and energy spectrometers at the International Linear Collider, which have been designed to fulfill the precision goals at a large range of beam energies from 45.6 GeV at the Z pole up to 250 GeV or, as an upgrade, up to 500 GeV.
△ Less
Submitted 7 October, 2009; v1 submitted 1 April, 2009;
originally announced April 2009.
-
Cavity BPM System Tests for the ILC Spectrometer
Authors:
M. Slater,
C. Adolphsen,
R. Arnold,
S. Boogert,
G. Boorman,
F. Gournaris,
M. Hildreth,
C. Hlaing,
F. Jackson,
O. Khainovski,
Yu. G. Kolomensky,
A. Lyapin,
B. Maiheu,
D. McCormick,
D. J. Miller,
T. J. Orimoto,
Z. Szalata,
M. Thomson,
D. Ward,
M. Wing,
M. Woods
Abstract:
The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-…
▽ More
The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a $1\m$ long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a $30\m$ long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.
△ Less
Submitted 9 December, 2007;
originally announced December 2007.
-
Status of the ATF extraction line laser-wire
Authors:
Nicolas Delerue,
Fred Gannaway,
David Howell,
Grahame Blair,
Gary Boorman,
Chafik Driouichi,
Stewart Boogert,
Alexander Aryshev,
Pavel Karataev,
Nobuhiro Terunuma,
Junji Urakawa,
Axel Brachmann,
Joe Frisch,
Marc Ross
Abstract:
A new laser-wire is being installed in the extraction line of the ATF at KEK. This device aims at demonstrating that laser-wires can be used to measure micrometre scale beam size.
A new laser-wire is being installed in the extraction line of the ATF at KEK. This device aims at demonstrating that laser-wires can be used to measure micrometre scale beam size.
△ Less
Submitted 18 January, 2006;
originally announced January 2006.
-
Beam Profile Measurements and Simulations of the PETRA Laser-Wire
Authors:
J. Carter,
I. Agapov,
G. A. Blair,
G. Boorman,
C. Driouichi,
F. Poirier,
M. T. Price,
T. Kamps,
K. Balewski,
H. Lewin,
S. Schreiber,
K. Wittenburg,
N. Delerue,
D. F. Howell,
S. T. Boogert,
S. Malton
Abstract:
The Laser-wire will be an essential diagnostic tool at the International Linear Collider. It uses a finely focussed laser beam to measure the transverse profile of electron bunches by detecting the Compton-scattered photons (or degraded electrons) downstream of where the laser beam intersects the electron beam. Such a system has been installed at the PETRA storage ring at DESY, which uses a piez…
▽ More
The Laser-wire will be an essential diagnostic tool at the International Linear Collider. It uses a finely focussed laser beam to measure the transverse profile of electron bunches by detecting the Compton-scattered photons (or degraded electrons) downstream of where the laser beam intersects the electron beam. Such a system has been installed at the PETRA storage ring at DESY, which uses a piezo-driven mirror to scan the laser-light across the electron beam. Lat- est results of experimental data taking are presented and compared to detailed simulations using the Geant4 based program BDSIM.
△ Less
Submitted 19 August, 2005;
originally announced August 2005.
-
A Test Facility for the International Linear Collider at SLAC End Station A, for Prototypes of Beam Delivery and IR Components
Authors:
M. Woods,
R. Erickson,
J. Frisch,
C. Hast,
R. K. Jobe,
L. Keller,
T. Markiewicz,
T. Maruyama,
D. McCormick,
J. Nelson,
T. Nelson,
N. Phinney,
T. Raubenheimer,
M. Ross,
A. Seryi,
S. Smith,
Z. Szalata,
P. Tenenbaum,
M. Woodley,
D. Angal-Kalinin,
C. Beard,
C. Densham,
J. Greenhalgh,
F. Jackson,
A. Kalinin
, et al. (36 additional authors not shown)
Abstract:
The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out expe…
▽ More
The SLAC Linac can deliver damped bunches with ILC parameters for bunch charge and bunch length to End Station A. A 10Hz beam at 28.5 GeV energy can be delivered there, parasitic with PEP-II operation. We plan to use this facility to test prototype components of the Beam Delivery System and Interaction Region. We discuss our plans for this ILC Test Facility and preparations for carrying out experiments related to collimator wakefields and energy spectrometers. We also plan an interaction region mockup to investigate effects from backgrounds and beam-induced electromagnetic interference.
△ Less
Submitted 24 May, 2005;
originally announced May 2005.
-
Heavy Quarkonium Physics
Authors:
N. Brambilla,
M. Krämer,
R. Mussa,
A. Vairo,
G. Bali,
G. T. Bodwin,
E. Braaten,
E. Eichten,
S. Eidelman,
S. Godfrey,
A. Hoang,
M. Jamin,
D. Kharzeev,
M. P. Lombardo,
C. Lourenco,
A. B. Meyer,
V. Papadimitriou,
C. Patrignani,
M. Rosati,
M. A. Sanchis-Lozano,
H. Satz,
J. Soto,
D. Z. Besson,
D. Bettoni,
A. Böhrer
, et al. (60 additional authors not shown)
Abstract:
This report is the result of the collaboration and research effort of the Quarkonium Working Group over the last three years. It provides a comprehensive overview of the state of the art in heavy-quarkonium theory and experiment, covering quarkonium spectroscopy, decay, and production, the determination of QCD parameters from quarkonium observables, quarkonia in media, and the effects on quarkon…
▽ More
This report is the result of the collaboration and research effort of the Quarkonium Working Group over the last three years. It provides a comprehensive overview of the state of the art in heavy-quarkonium theory and experiment, covering quarkonium spectroscopy, decay, and production, the determination of QCD parameters from quarkonium observables, quarkonia in media, and the effects on quarkonia of physics beyond the Standard Model. An introduction to common theoretical and experimental tools is included. Future opportunities for research in quarkonium physics are also discussed.
△ Less
Submitted 26 July, 2005; v1 submitted 13 December, 2004;
originally announced December 2004.
-
Physics Interplay of the LHC and the ILC
Authors:
LHC/LC Study Group,
:,
G. Weiglein,
T. Barklow,
E. Boos,
A. De Roeck,
K. Desch,
F. Gianotti,
R. Godbole,
J. F. Gunion,
H. E. Haber,
S. Heinemeyer,
J. L. Hewett,
K. Kawagoe,
K. Monig,
M. M. Nojiri,
G. Polesello,
F. Richard,
S. Riemann,
W. J. Stirling,
A. G. Akeroyd,
B. C. Allanach,
D. Asner,
S. Asztalos,
H. Baer
, et al. (99 additional authors not shown)
Abstract:
Physics at the Large Hadron Collider (LHC) and the International e+e- Linear Collider (ILC) will be complementary in many respects, as has been demonstrated at previous generations of hadron and lepton colliders. This report addresses the possible interplay between the LHC and ILC in testing the Standard Model and in discovering and determining the origin of new physics. Mutual benefits for the…
▽ More
Physics at the Large Hadron Collider (LHC) and the International e+e- Linear Collider (ILC) will be complementary in many respects, as has been demonstrated at previous generations of hadron and lepton colliders. This report addresses the possible interplay between the LHC and ILC in testing the Standard Model and in discovering and determining the origin of new physics. Mutual benefits for the physics programme at both machines can occur both at the level of a combined interpretation of Hadron Collider and Linear Collider data and at the level of combined analyses of the data, where results obtained at one machine can directly influence the way analyses are carried out at the other machine. Topics under study comprise the physics of weak and strong electroweak symmetry breaking, supersymmetric models, new gauge theories, models with extra dimensions, and electroweak and QCD precision physics. The status of the work that has been carried out within the LHC / LC Study Group so far is summarised in this report. Possible topics for future studies are outlined.
△ Less
Submitted 27 October, 2004;
originally announced October 2004.
-
Questions about the Measurement of the $\rm{e}^{+}\rm{e}^{-}$ Luminosity Spectrum at a future linear Collider
Authors:
Stewart T. Boogert,
David J. Miller
Abstract:
Important analyses at a future linear collider, including top-quark and W-boson mass measurements will depend upon the precise determination of the luminosity spectrum. This can be done, in principle,in the planned detectors. We review the problems to be solved, both beam-related and detector-related.
Important analyses at a future linear collider, including top-quark and W-boson mass measurements will depend upon the precise determination of the luminosity spectrum. This can be done, in principle,in the planned detectors. We review the problems to be solved, both beam-related and detector-related.
△ Less
Submitted 8 November, 2002;
originally announced November 2002.