-
Shower Separation in Five Dimensions for Highly Granular Calorimeters using Machine Learning
Authors:
S. Lai,
J. Utehs,
A. Wilhahn,
M. C. Fouz,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel,
A. Irles,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza,
M. Reinecke,
F. Sefkow,
S. Schuwalow,
M. De Silva,
Y. Sudo,
H. L. Tran,
L. Liu,
R. Masuda
, et al. (26 additional authors not shown)
Abstract:
To achieve state-of-the-art jet energy resolution for Particle Flow, sophisticated energy clustering algorithms must be developed that can fully exploit available information to separate energy deposits from charged and neutral particles. Three published neural network-based shower separation models were applied to simulation and experimental data to measure the performance of the highly granular…
▽ More
To achieve state-of-the-art jet energy resolution for Particle Flow, sophisticated energy clustering algorithms must be developed that can fully exploit available information to separate energy deposits from charged and neutral particles. Three published neural network-based shower separation models were applied to simulation and experimental data to measure the performance of the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL) technological prototype in distinguishing the energy deposited by a single charged and single neutral hadron for Particle Flow. The performance of models trained using only standard spatial and energy and charged track position information from an event was compared to models trained using timing information available from AHCAL, which is expected to improve sensitivity to shower development and, therefore, aid in clustering. Both simulation and experimental data were used to train and test the models and their performances were compared. The best-performing neural network achieved significantly superior event reconstruction when timing information was utilised in training for the case where the charged hadron had more energy than the neutral one, motivating temporally sensitive calorimeters. All models under test were observed to tend to allocate energy deposited by the more energetic of the two showers to the less energetic one. Similar shower reconstruction performance was observed for a model trained on simulation and applied to data and a model trained and applied to data.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Measurement of groomed event shape observables in deep-inelastic electron-proton scattering at HERA
Authors:
The H1 collaboration,
V. Andreev,
M. Arratia,
A. Baghdasaryan,
A. Baty,
K. Begzsuren,
A. Bolz,
V. Boudry,
G. Brandt,
D. Britzger,
A. Buniatyan,
L. Bystritskaya,
A. J. Campbell,
K. B. Cantun Avila,
K. Cerny,
V. Chekelian,
Z. Chen,
J. G. Contreras,
J. Cvach,
J. B. Dainton,
K. Daum,
A. Deshpande,
C. Diaconu,
A. Drees,
G. Eckerlin
, et al. (123 additional authors not shown)
Abstract:
The H1 Collaboration at HERA reports the first measurement of groomed event shape observables in deep inelastic electron-proton scattering (DIS) at $\sqrt{s}=319$ GeV, using data recorded between the years 2003 and 2007 with an integrated luminosity of $351$ pb$^{-1}$. Event shapes provide incisive probes of perturbative and non-perturbative QCD. Grooming techniques have been used for jet measurem…
▽ More
The H1 Collaboration at HERA reports the first measurement of groomed event shape observables in deep inelastic electron-proton scattering (DIS) at $\sqrt{s}=319$ GeV, using data recorded between the years 2003 and 2007 with an integrated luminosity of $351$ pb$^{-1}$. Event shapes provide incisive probes of perturbative and non-perturbative QCD. Grooming techniques have been used for jet measurements in hadronic collisions; this paper presents the first application of grooming to DIS data. The analysis is carried out in the Breit frame, utilizing the novel Centauro jet clustering algorithm that is designed for DIS event topologies. Events are required to have squared momentum-transfer $Q^2 > 150$ GeV$^2$ and inelasticity $ 0.2 < y < 0.7$. We report measurements of the production cross section of groomed event 1-jettiness and groomed invariant mass for several choices of grooming parameter. Monte Carlo model calculations and analytic calculations based on Soft Collinear Effective Theory are compared to the measurements.
△ Less
Submitted 1 August, 2024; v1 submitted 15 March, 2024;
originally announced March 2024.
-
Measurement of the 1-jettiness event shape observable in deep-inelastic electron-proton scattering at HERA
Authors:
The H1 collaboration,
V. Andreev,
M. Arratia,
A. Baghdasaryan,
A. Baty,
K. Begzsuren,
A. Bolz,
V. Boudry,
G. Brandt,
D. Britzger,
A. Buniatyan,
L. Bystritskaya,
A. J. Campbell,
K. B. Cantun Avila,
K. Cerny,
V. Chekelian,
Z. Chen,
J. G. Contreras,
J. Cvach,
J. B. Dainton,
K. Daum,
A. Deshpande,
C. Diaconu,
A. Drees,
G. Eckerlin
, et al. (124 additional authors not shown)
Abstract:
The H1 Collaboration reports the first measurement of the 1-jettiness event shape observable $τ_1^b$ in neutral-current deep-inelastic electron-proton scattering (DIS). The observable $τ_1^b$ is equivalent to a thrust observable defined in the Breit frame. The data sample was collected at the HERA $ep$ collider in the years 2003-2007 with center-of-mass energy of $\sqrt{s}=319\,\text{GeV}$, corres…
▽ More
The H1 Collaboration reports the first measurement of the 1-jettiness event shape observable $τ_1^b$ in neutral-current deep-inelastic electron-proton scattering (DIS). The observable $τ_1^b$ is equivalent to a thrust observable defined in the Breit frame. The data sample was collected at the HERA $ep$ collider in the years 2003-2007 with center-of-mass energy of $\sqrt{s}=319\,\text{GeV}$, corresponding to an integrated luminosity of $351.1\,\text{pb}^{-1}$. Triple differential cross sections are provided as a function of $τ_1^b$, event virtuality $Q^2$, and inelasticity $y$, in the kinematic region $Q^2>150\,\text{GeV}^{2}$. Single differential cross section are provided as a function of $τ_1^b$ in a limited kinematic range. Double differential cross sections are measured, in contrast, integrated over $τ_1^b$ and represent the inclusive neutral-current DIS cross section measured as a function of $Q^2$ and $y$. The data are compared to a variety of predictions and include classical and modern Monte Carlo event generators, predictions in fixed-order perturbative QCD where calculations up to $\mathcal{O}(α_s^3)$ are available for $τ_1^b$ or inclusive DIS, and resummed predictions at next-to-leading logarithmic accuracy matched to fixed order predictions at $\mathcal{O}(α_s^2)$. These comparisons reveal sensitivity of the 1-jettiness observable to QCD parton shower and resummation effects, as well as the modeling of hadronization and fragmentation. Within their range of validity, the fixed-order predictions provide a good description of the data. Monte Carlo event generators are predictive over the full measured range and hence their underlying models and parameters can be constrained by comparing to the presented data.
△ Less
Submitted 15 March, 2024;
originally announced March 2024.
-
Observation and differential cross section measurement of neutral current DIS events with an empty hemisphere in the Breit frame
Authors:
The H1 collaboration,
V. Andreev,
M. Arratia,
A. Baghdasaryan,
A. Baty,
K. Begzsuren,
A. Bolz,
V. Boudry,
G. Brandt,
D. Britzger,
A. Buniatyan,
L. Bystritskaya,
A. J. Campbell,
K. B. Cantun Avila,
K. Cerny,
V. Chekelian,
Z. Chen,
J. G. Contreras,
J. Cvach,
J. B. Dainton,
K. Daum,
A. Deshpande,
C. Diaconu,
A. Drees,
G. Eckerlin
, et al. (124 additional authors not shown)
Abstract:
The Breit frame provides a natural frame to analyze lepton-proton scattering events. In this reference frame, the parton model hard interactions between a quark and an exchanged boson defines the coordinate system such that the struck quark is back-scattered along the virtual photon momentum direction. In Quantum Chromodynamics (QCD), higher order perturbative or non-perturbative effects can chang…
▽ More
The Breit frame provides a natural frame to analyze lepton-proton scattering events. In this reference frame, the parton model hard interactions between a quark and an exchanged boson defines the coordinate system such that the struck quark is back-scattered along the virtual photon momentum direction. In Quantum Chromodynamics (QCD), higher order perturbative or non-perturbative effects can change this picture drastically. As Bjorken-$x$ decreases below one half, a rather peculiar event signature is predicted with increasing probability, where no radiation is present in one of the two Breit-frame hemispheres and all emissions are to be found in the other hemisphere. At higher orders in $α_s$ or in the presence of soft QCD effects, predictions of the rate of these events are far from trivial, and that motivates measurements with real data. We report on the first observation of the empty current hemisphere events in electron-proton collisions at the HERA collider using data recorded with the H1 detector at a center-of-mass energy of 319 GeV. The fraction of inclusive neutral-current DIS events with an empty hemisphere is found to be $0.0112 \pm 3.9\,\%_\text{stat} \pm 4.5\,\%_\text{syst} \pm 1.6\,\%_\text{mod}$ in the selected kinematic region of $150< Q^2<1500$ GeV$^2$ and inelasticity $0.14< y<0.7$. The data sample corresponds to an integrated luminosity of 351.1 pb$^{-1}$, sufficient to enable differential cross section measurements of these events. The results show an enhanced discriminating power at lower Bjorken-$x$ among different Monte Carlo event generator predictions.
△ Less
Submitted 1 August, 2024; v1 submitted 13 March, 2024;
originally announced March 2024.
-
Software Compensation for Highly Granular Calorimeters using Machine Learning
Authors:
S. Lai,
J. Utehs,
A. Wilhahn,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
D. Heuchel,
A. Irles,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza,
M. Reinecke,
F. Sefkow,
S. Schuwalow,
M. De Silva,
Y. Sudo,
H. L. Tran,
E. Buhmann,
E. Garutti,
S. Huck
, et al. (39 additional authors not shown)
Abstract:
A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy w…
▽ More
A neural network for software compensation was developed for the highly granular CALICE Analogue Hadronic Calorimeter (AHCAL). The neural network uses spatial and temporal event information from the AHCAL and energy information, which is expected to improve sensitivity to shower development and the neutron fraction of the hadron shower. The neural network method produced a depth-dependent energy weighting and a time-dependent threshold for enhancing energy deposits consistent with the timescale of evaporation neutrons. Additionally, it was observed to learn an energy-weighting indicative of longitudinal leakage correction. In addition, the method produced a linear detector response and outperformed a published control method regarding resolution for every particle energy studied.
△ Less
Submitted 7 March, 2024;
originally announced March 2024.
-
Energy and Time Histograms: Fluxes determination in calorimeters
Authors:
Khalid Hassouna,
Vincent Boudry
Abstract:
In high-granularity calorimetry, as proposed for detectors at future Higgs factories, the requirements on electronics can have a strong impact on the design of the detector, especially via the cooling and acquisition systems. This project aims to establish the typical fluxes in the calorimeters: deposited energy, number of cells above the electronics threshold, additional heat, and associated data…
▽ More
In high-granularity calorimetry, as proposed for detectors at future Higgs factories, the requirements on electronics can have a strong impact on the design of the detector, especially via the cooling and acquisition systems. This project aims to establish the typical fluxes in the calorimeters: deposited energy, number of cells above the electronics threshold, additional heat, and associated data, etc. Here, a software package is presented which outputs histograms for different selections of the calorimeter components from fully simulated physics and background events. The ILD calorimeter system is taken as a specific example, upon which different histograms are obtained for representative parts of the calorimeter and for various machine configurations. Examples of histograms are shown, along with all details of the data used and the simulation.
△ Less
Submitted 11 March, 2024; v1 submitted 6 March, 2024;
originally announced March 2024.
-
Technical Design Report for the LUXE Experiment
Authors:
H. Abramowicz,
M. Almanza Soto,
M. Altarelli,
R. Aßmann,
A. Athanassiadis,
G. Avoni,
T. Behnke,
M. Benettoni,
Y. Benhammou,
J. Bhatt,
T. Blackburn,
C. Blanch,
S. Bonaldo,
S. Boogert,
O. Borysov,
M. Borysova,
V. Boudry,
D. Breton,
R. Brinkmann,
M. Bruschi,
F. Burkart,
K. Büßer,
N. Cavanagh,
F. Dal Corso,
W. Decking
, et al. (109 additional authors not shown)
Abstract:
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger fiel…
▽ More
This Technical Design Report presents a detailed description of all aspects of the LUXE (Laser Und XFEL Experiment), an experiment that will combine the high-quality and high-energy electron beam of the European XFEL with a high-intensity laser, to explore the uncharted terrain of strong-field quantum electrodynamics characterised by both high energy and high intensity, reaching the Schwinger field and beyond. The further implications for the search of physics beyond the Standard Model are also discussed.
△ Less
Submitted 2 August, 2023; v1 submitted 1 August, 2023;
originally announced August 2023.
-
Unbinned Deep Learning Jet Substructure Measurement in High $Q^2$ ep collisions at HERA
Authors:
The H1 collaboration,
V. Andreev,
M. Arratia,
A. Baghdasaryan,
A. Baty,
K. Begzsuren,
A. Bolz,
V. Boudry,
G. Brandt,
D. Britzger,
A. Buniatyan,
L. Bystritskaya,
A. J. Campbell,
K. B. Cantun Avila,
K. Cerny,
V. Chekelian,
Z. Chen,
J. G. Contreras,
J. Cvach,
J. B. Dainton,
K. Daum,
A. Deshpande,
C. Diaconu,
A. Drees,
G. Eckerlin
, et al. (120 additional authors not shown)
Abstract:
The radiation pattern within high energy quark- and gluon-initiated jets (jet substructure) is used extensively as a precision probe of the strong force as well as an environment for optimizing event generators with numerous applications in high energy particle and nuclear physics. Looking at electron-proton collisions is of particular interest as many of the complications present at hadron collid…
▽ More
The radiation pattern within high energy quark- and gluon-initiated jets (jet substructure) is used extensively as a precision probe of the strong force as well as an environment for optimizing event generators with numerous applications in high energy particle and nuclear physics. Looking at electron-proton collisions is of particular interest as many of the complications present at hadron colliders are absent. A detailed study of modern jet substructure observables, jet angularities, in electron-proton collisions is presented using data recorded using the H1 detector at HERA. The measurement is unbinned and multi-dimensional, using machine learning to correct for detector effects. All of the available reconstructed object information of the respective jets is interpreted by a graph neural network, achieving superior precision on a selected set of jet angularities. Training these networks was enabled by the use of a large number of GPUs in the Perlmutter supercomputer at Berkeley Lab. The particle jets are reconstructed in the laboratory frame, using the $k_{\mathrm{T}}$ jet clustering algorithm. Results are reported at high transverse momentum transfer $Q^2>150$ GeV${}^2$, and inelasticity $0.2 < y < 0.7$. The analysis is also performed in sub-regions of $Q^2$, thus probing scale dependencies of the substructure variables. The data are compared with a variety of predictions and point towards possible improvements of such models.
△ Less
Submitted 14 September, 2023; v1 submitted 23 March, 2023;
originally announced March 2023.
-
New results from the technological prototype of the CALICE highly-granular silicon tungsten electromagnetic calorimeter
Authors:
Vincent Boudry
Abstract:
An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common set. The noise, self-trigger performances and response to punch-though electrons, without tungsten absorbers, have been evaluated for each of the 15360 channel…
▽ More
An extended version of the CALICE silicon-tungsten ECAL was tested in November 2021 at the DESY beam test facility. With 15 active layers, it featured some with a thin PCB design, and a new compact DAQ system handling all layers in a common set. The noise, self-trigger performances and response to punch-though electrons, without tungsten absorbers, have been evaluated for each of the 15360 channels, using an improved procedure. Showers of low-energy electrons (1 to 6 GeV) have been recorded in two configurations of absorber, and are being analysed. Some preliminary results at the cell level will be presented.
△ Less
Submitted 27 April, 2023; v1 submitted 10 November, 2022;
originally announced November 2022.
-
Cluster time measurement with CEPC calorimeter
Authors:
Yuzhi Che,
Vincent Boudry,
Henri Videau,
Muchen He,
Manqi Ruan
Abstract:
We have developed an algorithm dedicated to timing reconstruction in highly granular calorimeters (HGC). The performance of this algorithm is evaluated on an electromagnetic calorimeter (ECAL) with geometries comparable to the electromagnetic compartment (CE-E) of the CMS endcap calorimeter upgrade at HL-LHC and conceptual Particle Flow oriented ECAL's for future Higgs factories. The time response…
▽ More
We have developed an algorithm dedicated to timing reconstruction in highly granular calorimeters (HGC). The performance of this algorithm is evaluated on an electromagnetic calorimeter (ECAL) with geometries comparable to the electromagnetic compartment (CE-E) of the CMS endcap calorimeter upgrade at HL-LHC and conceptual Particle Flow oriented ECAL's for future Higgs factories. The time response of individual channel is parameterized according to the CMS experimental result. The particle Time-of-Flight (ToF) can be measured with a resolution of $5\sim20 \;\rm{ps}$ for electromagnetic (EM) showers and $80\sim 160 \;\rm{ps}$ for hadronic showers above 1 GeV. The presented algorithm can significantly improve the time resolution, compared to a simple averaging of the fast component of the time spectrum. The effects of three detector configurations are also quantified in this study. ToF resolution depends linearly on the timing resolution of a single silicon sensor and improves statistically with increasing incident particle energy. A clustering algorithm that vetos isolated hits improves ToF resolution.
△ Less
Submitted 7 September, 2022;
originally announced September 2022.
-
The International Linear Collider: Report to Snowmass 2021
Authors:
Alexander Aryshev,
Ties Behnke,
Mikael Berggren,
James Brau,
Nathaniel Craig,
Ayres Freitas,
Frank Gaede,
Spencer Gessner,
Stefania Gori,
Christophe Grojean,
Sven Heinemeyer,
Daniel Jeans,
Katja Kruger,
Benno List,
Jenny List,
Zhen Liu,
Shinichiro Michizono,
David W. Miller,
Ian Moult,
Hitoshi Murayama,
Tatsuya Nakada,
Emilio Nanni,
Mihoko Nojiri,
Hasan Padamsee,
Maxim Perelstein
, et al. (487 additional authors not shown)
Abstract:
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This docu…
▽ More
The International Linear Collider (ILC) is on the table now as a new global energy-frontier accelerator laboratory taking data in the 2030s. The ILC addresses key questions for our current understanding of particle physics. It is based on a proven accelerator technology. Its experiments will challenge the Standard Model of particle physics and will provide a new window to look beyond it. This document brings the story of the ILC up to date, emphasizing its strong physics motivation, its readiness for construction, and the opportunity it presents to the US and the global particle physics community.
△ Less
Submitted 16 January, 2023; v1 submitted 14 March, 2022;
originally announced March 2022.
-
Precision timing for collider-experiment-based calorimetry
Authors:
S. V. Chekanov,
F. Simon,
V. Boudry,
W. Chung,
P. W. Gorham,
M. Nguyen,
C. G. Tully,
S. C. Eno,
Y. Lai,
A. V. Kotwal,
S. Ko,
I. Laktineh,
S. Lee,
J. S. H. Lee,
M. T. Lucchini,
R. Prechelt,
H. Yoo,
C. -H Yeh,
S. -S. Yu,
G. S. Varner,
R. Zhu
Abstract:
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the f…
▽ More
In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle identification, event and object reconstruction, and pileup mitigation. Two different system options are considered, namely cell-level timing capabilities covering the full detector volume, and dedicated timing layers integrated in calorimeter systems. A selection of technologies for the different approaches is also discussed.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Impact of jet-production data on the next-to-next-to-leading-order determination of HERAPDF2.0 parton distributions
Authors:
H1,
ZEUS Collaborations,
:,
I. Abt,
R. Aggarwal,
V. Andreev,
M. Arratia,
V. Aushev,
A. Baghdasaryan,
A. Baty,
K. Begzsuren,
O. Behnke,
A. Belousov,
A. Bertolin,
I. Bloch,
V. Boudry,
G. Brandt,
I. Brock,
N. H. Brook,
R. Brugnera,
A. Bruni,
A. Buniatyan,
P. J. Bussey,
L. Bystritskaya,
A. Caldwell
, et al. (212 additional authors not shown)
Abstract:
The HERAPDF2.0 ensemble of parton distribution functions (PDFs) was introduced in 2015. The final stage is presented, a next-to-next-to-leading-order (NNLO) analysis of the HERA data on inclusive deep inelastic $ep$ scattering together with jet data as published by the H1 and ZEUS collaborations. A perturbative QCD fit, simultaneously of $α_s(M_Z^2)$ and and the PDFs, was performed with the result…
▽ More
The HERAPDF2.0 ensemble of parton distribution functions (PDFs) was introduced in 2015. The final stage is presented, a next-to-next-to-leading-order (NNLO) analysis of the HERA data on inclusive deep inelastic $ep$ scattering together with jet data as published by the H1 and ZEUS collaborations. A perturbative QCD fit, simultaneously of $α_s(M_Z^2)$ and and the PDFs, was performed with the result $α_s(M_Z^2) = 0.1156 \pm 0.0011~{\rm (exp)}~ ^{+0.0001}_{-0.0002}~ {\rm (model}$ ${\rm +~parameterisation)}~ \pm 0.0029~{\rm (scale)}$. The PDF sets of HERAPDF2.0Jets NNLO were determined with separate fits using two fixed values of $α_s(M_Z^2)$, $α_s(M_Z^2)=0.1155$ and $0.118$, since the latter value was already chosen for the published HERAPDF2.0 NNLO analysis based on HERA inclusive DIS data only. The different sets of PDFs are presented, evaluated and compared. The consistency of the PDFs determined with and without the jet data demonstrates the consistency of HERA inclusive and jet-production cross-section data. The inclusion of the jet data reduced the uncertainty on the gluon PDF. Predictions based on the PDFs of HERAPDF2.0Jets NNLO give an excellent description of the jet-production data used as input.
△ Less
Submitted 2 December, 2021;
originally announced December 2021.
-
Measurement of lepton-jet correlation in deep-inelastic scattering with the H1 detector using machine learning for unfolding
Authors:
H1 Collaboration,
V. Andreev,
M. Arratia,
A. Baghdasaryan,
A. Baty,
K. Begzsuren,
A. Belousov,
A. Bolz,
V. Boudry,
G. Brandt,
D. Britzger,
A. Buniatyan,
L. Bystritskaya,
A. J. Campbell,
K. B. Cantun Avila,
K. Cerny,
V. Chekelian,
Z. Chen,
J. G. Contreras,
L. Cunqueiro Mendez,
J. Cvach,
J. B. Dainton,
K. Daum,
A. Deshpande,
C. Diaconu
, et al. (120 additional authors not shown)
Abstract:
The first measurement of lepton-jet momentum imbalance and azimuthal correlation in lepton-proton scattering at high momentum transfer is presented. These data, taken with the H1 detector at HERA, are corrected for detector effects using an unbinned machine learning algorithm OmniFold, which considers eight observables simultaneously in this first application. The unfolded cross sections are compa…
▽ More
The first measurement of lepton-jet momentum imbalance and azimuthal correlation in lepton-proton scattering at high momentum transfer is presented. These data, taken with the H1 detector at HERA, are corrected for detector effects using an unbinned machine learning algorithm OmniFold, which considers eight observables simultaneously in this first application. The unfolded cross sections are compared to calculations performed within the context of collinear or transverse-momentum-dependent (TMD) factorization in Quantum Chromodynamics (QCD) as well as Monte Carlo event generators. The measurement probes a wide range of QCD phenomena, including TMD parton distribution functions and their evolution with energy in so far unexplored kinematic regions.
△ Less
Submitted 1 April, 2022; v1 submitted 27 August, 2021;
originally announced August 2021.
-
A combined fit to the Higgs Branching Ratios at ILD
Authors:
Jonas Kunath,
Fabricio Jimenez Morales,
Jean-Claude Brient,
Vincent Boudry
Abstract:
Higgs decay branching ratios at future Higgs factories can be measured by directly exploiting class numeration. Given the clean environment at a lepton collider, it is possible to build an event sample highly enriched in Higgs bosons and essentially unbiased for any decay mode. The sample can be partitioned into categories using event properties linked to the expected Higgs decay modes. The counts…
▽ More
Higgs decay branching ratios at future Higgs factories can be measured by directly exploiting class numeration. Given the clean environment at a lepton collider, it is possible to build an event sample highly enriched in Higgs bosons and essentially unbiased for any decay mode. The sample can be partitioned into categories using event properties linked to the expected Higgs decay modes. The counts per category are used to fit the Higgs branching ratios in a model independent way. The result of the fit is the set of branching ratios, independent from a Higgs production mode measurement.
We present a simplified study on simulated data for the International Linear Detector (ILD) at the International Linear Collider (ILC) at 250 GeV center-of-mass energy.
△ Less
Submitted 12 May, 2021;
originally announced May 2021.
-
Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype
Authors:
D. Boumediene,
A. Pingault,
M. Tytgat,
B. Bilki,
D. Northacker,
Y. Onel,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
Y. Deguchi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
L. Caponetto,
C. Combaret,
R. Ete G. Garillot,
G. Grenier,
J-C. Ianigro,
T. Kurca,
I. Laktineh
, et al. (65 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines…
▽ More
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
ILD Silicon Tungsten Electromagnetic Calorimeter First Full Scale Electronic Prototype
Authors:
Frédéric Magniette,
Jérôme Nanni,
Rémi Guillaumat,
Marc Louzir,
Marc Anduze,
Evelyne Edy,
Oleksandr Korostyshevskyi,
Vladislav Balagura,
Vincent Boudry,
Jean-Claude Brient
Abstract:
The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a full length detecting layer (1.60m for the ILD barrel). Indeed, this length induces difficulties for clock and signal propagation and data integrity. The design…
▽ More
The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a full length detecting layer (1.60m for the ILD barrel). Indeed, this length induces difficulties for clock and signal propagation and data integrity. The design used for short length slabs had to be adapted on the basis of a simulation study. The long slab performance has been tested with cosmics, radioactive source and with 3 GeV electrons in the beam tests at DESY, Hamburg. The results of the per-channel calibration of the detector are presented. In DESY beam tests we have accumulated data for both normal and inclined incidence of the beam. With the latter one particle can sometimes traverse two pixels and deposit less energy per pixel. We show how this can be used to measure the position of the trigger threshold. This new prototype gives us a lot of hints on how to improve the design of the front-end electronics. It is also a convenient tool to estimate the key characteristics of ILD SiW-Ecal (like power consumption, cooling, readout time etc.) and to optimize the future design of the detector.
△ Less
Submitted 10 September, 2019;
originally announced September 2019.
-
Higgs to $ττ$ analysis in the future $e^{+}e^{-}$ Higgs factories
Authors:
Dan Yu,
Manqi Ruan,
Vincent Boudry,
Henri Videau,
Jean-Claude Brient
Abstract:
The Circular Electron Positron Collider and International Linear Collider are two electron positron Higgs factories. They are designed to operate at center-of-mass energy of 240 and 250 GeV and accumulate 5.6 and 2 $ab^{-1}$ of integrated luminosity. Using CEPC official samples, the signal strength for Higgs to $ττ$ events are analyzed. The combined accuracy of the signal strength for…
▽ More
The Circular Electron Positron Collider and International Linear Collider are two electron positron Higgs factories. They are designed to operate at center-of-mass energy of 240 and 250 GeV and accumulate 5.6 and 2 $ab^{-1}$ of integrated luminosity. Using CEPC official samples, the signal strength for Higgs to $ττ$ events are analyzed. The combined accuracy of the signal strength for $H\rightarrow ττ$ at CEPC achieves 0.8\%. Extrapolating this analysis to the ILC setup, we conclude the ILC can reach a relative accuracy of 1.1\% or 1.2\%, corresponding to two benchmark settings of the beam polarization.
△ Less
Submitted 8 May, 2020; v1 submitted 28 March, 2019;
originally announced March 2019.
-
Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype
Authors:
CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
Y. Do,
A. Khan,
D. Kim,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Kawagoe,
Y. Miura,
R. Mori,
I. Sekiya,
T. Suehara,
T. Yoshioka,
J. Apostolakis,
J. Giraud,
D. Grondin,
J. -Y. Hostachy,
O. Bach,
V. Bocharnikov,
E. Brianne
, et al. (81 additional authors not shown)
Abstract:
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorith…
▽ More
A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.
△ Less
Submitted 18 September, 2019; v1 submitted 16 February, 2019;
originally announced February 2019.
-
Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC
Authors:
K. Kawagoe,
Y. Miura,
I. Sekiya,
T. Suehara,
T. Yoshioka,
S. Bilokin,
J. Bonis,
P. Cornebise,
A. Gallas,
A. Irles,
R. Pöschl,
F. Richard,
A. Thiebault,
D. Zerwas,
M. Anduze,
V. Balagura,
V. Boudry,
J-C. Brient,
E. Edy,
G. Fayolle,
M. Frotin,
F. Gastaldi,
R. Guillaumat,
A. Lobanov,
M. Louzir
, et al. (19 additional authors not shown)
Abstract:
The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 $5.5\times5.5$ mm$^2$ silicon PIN diodes. The four sensors covered a total area of $18\times18$ cm$^2$, and comprise…
▽ More
The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 $5.5\times5.5$ mm$^2$ silicon PIN diodes. The four sensors covered a total area of $18\times18$ cm$^2$, and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.
△ Less
Submitted 22 October, 2019; v1 submitted 31 January, 2019;
originally announced February 2019.
-
Commissioning of the highly granular SiW-ECAL technological prototype
Authors:
S. Bilokin,
J. Bonis,
P. Cornebise,
A. Gallas,
A. Irles,
R. Pöschl,
F. Richard,
A. Thiebault,
D. Zerwas,
M. Anduze,
V. Balagura,
V. Boudry,
J-C. Brient,
E. Edy,
G. Fayolle,
M. Frotin,
F. Gastaldi,
A. Lobanov,
F. Magniette,
J. Nanni,
M. Rubio-Roy,
K. Shpak,
H. Videau,
D. Yu,
S. Callier
, et al. (18 additional authors not shown)
Abstract:
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number similar to that envisaged for e.g. the ILD Detector of the International Linear Collider (ILC). The analysis demonstrates the capability of the detector to record si…
▽ More
In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number similar to that envisaged for e.g. the ILD Detector of the International Linear Collider (ILC). The analysis demonstrates the capability of the detector to record signals as low as 0.5 MIP. Further, no loss of performance has been observed when operating the detector in a high magnetic field.
△ Less
Submitted 4 April, 2019; v1 submitted 11 October, 2018;
originally announced October 2018.
-
Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System
Authors:
CALICE Collaboration,
J. Repond,
L. Xia,
J. Apostolakis,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
V. Francais,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
O. Bach,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Gttlicher,
O. Hartbrich F. Krivan,
K. Krüger,
J. Kvasnicka,
S. Lu,
C. Neubüser,
A. Provenza
, et al. (84 additional authors not shown)
Abstract:
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles.…
▽ More
This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.
△ Less
Submitted 12 September, 2018; v1 submitted 11 September, 2018;
originally announced September 2018.
-
Reconstruction of physics objects at the Circular Electron Positron Collider with Arbor
Authors:
Manqi Ruan,
Hang Zhao,
Gang Li,
Chengdong Fu,
Zhigang Wang,
Xinchou Lou,
Dan Yu,
Vincent Boudry,
Henri Videau,
Vladislav Balagura,
Jean-Claude Brient,
Peizhu Lai,
Chia-Ming Kuo,
Bo Liu,
Fenfen An,
Chunhui Chen,
Soeren Prell,
Bo Li,
Imad Laketineh
Abstract:
After the Higgs discovery, precise measurements of the Higgs properties and the electroweak observables become vital for the experimental particle physics. A powerful Higgs/Z factory, the Circular Electron Positron Collider(CEPC) is proposed. The Particle Flow oriented detector design is proposed to the CEPC and a Particle Flow algorithm, Arbor is optimized accordingly. We summarize the physics ob…
▽ More
After the Higgs discovery, precise measurements of the Higgs properties and the electroweak observables become vital for the experimental particle physics. A powerful Higgs/Z factory, the Circular Electron Positron Collider(CEPC) is proposed. The Particle Flow oriented detector design is proposed to the CEPC and a Particle Flow algorithm, Arbor is optimized accordingly. We summarize the physics object reconstruction performance of the Particle Flow oriented detector design with Arbor algorithm and conclude that this combination fulfills the physics requirement of CEPC.
△ Less
Submitted 13 June, 2018;
originally announced June 2018.
-
Performance study of SKIROC2/A ASIC for ILD Si-W ECAL
Authors:
T. Suehara,
I. Sekiya,
S. Callier,
V. Balagura,
V. Boudry,
J-C. Brient,
C. de la Taille,
K. Kawagoe,
A. Irles,
F. Magniette,
J. Nanni,
R. Poeschl,
T. Yoshioka,
ILD SiW-ECAL group
Abstract:
The ILD Si-W ECAL is a sampling calorimeter with tungsten absorber and highly segmented silicon layers for the International Large Detector (ILD), one of the two detector concepts for the International Linear Collider. SKIROC2 is an ASIC for the ILD Si-WECAL. To investigate the issues found in prototype detectors, we prepared dedicated ASIC evaluation boards with either BGA sockets or directly sol…
▽ More
The ILD Si-W ECAL is a sampling calorimeter with tungsten absorber and highly segmented silicon layers for the International Large Detector (ILD), one of the two detector concepts for the International Linear Collider. SKIROC2 is an ASIC for the ILD Si-WECAL. To investigate the issues found in prototype detectors, we prepared dedicated ASIC evaluation boards with either BGA sockets or directly soldered SKIROC2. We report a performance study with the evaluation boards, including signal-to-noise ratio and TDC performance with comparing SKIROC2 and an updated version, SKIROC2A.
△ Less
Submitted 6 January, 2018;
originally announced January 2018.
-
Determination of the strong coupling constant $α_s(M_Z)$ in next-to-next-to-leading order QCD using H1 jet cross section measurements
Authors:
H1 collaboration,
V. Andreev,
A. Baghdasaryan,
K. Begzsuren,
A. Belousov,
V. Bertone,
A. Bolz,
V. Boudry,
G. Brandt,
V. Brisson,
D. Britzger,
A. Buniatyan,
A. Bylinkin,
L. Bystritskaya,
A. J. Campbell,
K. B. Cantun Avila,
K. Cerny,
V. Chekelian,
J. G. Contreras,
J. Cvach,
J. Currie,
J. B. Dainton,
K. Daum,
C. Diaconu,
M. Dobre
, et al. (123 additional authors not shown)
Abstract:
The strong coupling constant $α_s(M_Z)$ is determined from inclusive jet and dijet cross sections in neutral-current deep-inelastic $ep$ scattering (DIS) measured at HERA by the H1 collaboration using next-to-next-to-leading order (NNLO) QCD predictions. The dependence of the NNLO predictions and of the resulting value of $α_s(M_Z)$ at the $Z$-boson mass $m_Z$ are studied as a function of the choi…
▽ More
The strong coupling constant $α_s(M_Z)$ is determined from inclusive jet and dijet cross sections in neutral-current deep-inelastic $ep$ scattering (DIS) measured at HERA by the H1 collaboration using next-to-next-to-leading order (NNLO) QCD predictions. The dependence of the NNLO predictions and of the resulting value of $α_s(M_Z)$ at the $Z$-boson mass $m_Z$ are studied as a function of the choice of the renormalisation and factorisation scales. Using inclusive jet and dijet data together, the strong coupling constant is determined to be $α_s(M_Z)=0.1166\,(19)_{\rm exp}\,(24)_{\rm th}$. Complementary, $α_s(M_Z)$ is determined together with parton distribution functions of the proton (PDFs) from jet and inclusive DIS data measured by the H1 experiment. The value $α_s(M_Z)=0.1147\,(25)_{\rm tot}$ obtained is consistent with the determination from jet data alone. The impact of the jet data on the PDFs is studied. The running of the strong coupling is tested at different values of the renormalisation scale and the results are found to be in agreement with expectations.
△ Less
Submitted 16 June, 2021; v1 submitted 21 September, 2017;
originally announced September 2017.
-
Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter
Authors:
CALICE collaboration,
J. Repond,
L. Xia,
G. Eigen,
T. Price,
N. K. Watson,
A. Winter,
M. A. Thomson,
G. C. Blazey,
A. Dyshkant,
K. Francis,
V. Zutshi,
K. Gadow,
P. Göttlicher,
O. Hartbrich,
F. Krivan,
K. Krüger,
S. Lu,
B. Lutz,
M. Reinecke,
F. Sefkow,
Y. Sudo,
H. L. Tran,
A. Kaplan,
H. -Ch. Schultz-Coulon
, et al. (57 additional authors not shown)
Abstract:
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab…
▽ More
A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.
△ Less
Submitted 28 February, 2018; v1 submitted 22 July, 2017;
originally announced July 2017.
-
SiW ECAL for future $e^+e^-$ collider
Authors:
V. Balagura,
S. Bilokin,
J. Bonis,
V. Boudry,
J. -C. Brient,
S. Callier,
T. Cheng,
R. Cornat,
C. De La Taille,
T. H. Doan,
M. Frotin,
F. Gastaldi,
H. Hirai,
S. Jain,
Sh. Jain,
D. Lacour,
L. Lavergne,
A. Lleres,
F. Magniette,
L. Mastrolorenzo,
J. Nanni,
R. Poeschl,
A. Pozdnyakov,
A. Psallidas,
M. Ruan
, et al. (7 additional authors not shown)
Abstract:
Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We discuss the tests of the first three 18x18 cm$^2$ layers segmented into 1024 pixels of the technological prototype of the silicon-tungsten electromagnetic calorimeter for a future $e^+e^-$ collider. The tests have beem performed in November 2015 at CERN SPS beam line.
Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We discuss the tests of the first three 18x18 cm$^2$ layers segmented into 1024 pixels of the technological prototype of the silicon-tungsten electromagnetic calorimeter for a future $e^+e^-$ collider. The tests have beem performed in November 2015 at CERN SPS beam line.
△ Less
Submitted 20 June, 2017; v1 submitted 30 May, 2017;
originally announced May 2017.
-
Lepton identification at particle flow oriented detector for the future $e^{+}e^{-}$ Higgs factories
Authors:
Dan Yu,
Manqi Ruan,
Vincent Boudry,
Henri Videau
Abstract:
The lepton identification is essential for the physics programs at high-energy frontier, especially for the precise measurement of the Higgs boson. For this purpose, a Toolkit for Multivariate Data Analysis (TMVA) based lepton identification (LICH) has been developed for detectors using high granularity calorimeters. Using the conceptual detector geometry for the Circular Electron-Positron Collide…
▽ More
The lepton identification is essential for the physics programs at high-energy frontier, especially for the precise measurement of the Higgs boson. For this purpose, a Toolkit for Multivariate Data Analysis (TMVA) based lepton identification (LICH) has been developed for detectors using high granularity calorimeters. Using the conceptual detector geometry for the Circular Electron-Positron Collider (CEPC) and single charged particle samples with energy larger than 2 GeV, LICH identifies electrons/muons with efficiencies higher than 99.5% and controls the mis-identification rate of hadron to muons/electrons to better than 1%/0.5%. Reducing the calorimeter granularity by 1-2 orders of magnitude, the lepton identification performance is stable for particles with E > 2 GeV. Applied to fully simulated eeH/$μμ$H events, the lepton identification performance is consistent with the single particle case: the efficiency of identifying all the high energy leptons in an event, is 95.5-98.5%.
△ Less
Submitted 17 February, 2017; v1 submitted 25 January, 2017;
originally announced January 2017.
-
Resistive Plate Chamber Digitization in a Hadronic Shower Environment
Authors:
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
J. Apostolakis,
G. Folger,
C. Grefe,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
D. Boumediene,
C. Carloganu,
V. Français,
G. Cho,
D-W. Kim,
S. C. Lee,
W. Park,
S. Vallecorsa,
S. Cauwenbergh,
M. Tytgat,
A. Pingault,
N. Zaganidis,
E. Brianne,
A. Ebrahimi
, et al. (103 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, e…
▽ More
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
△ Less
Submitted 15 April, 2016;
originally announced April 2016.
-
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
Authors:
The CALICE Collaboration,
G. Eigen,
T. Price,
N. K. Watson,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon,
V. Uzhinskiy,
J. -Y. Hostachy,
L. Morin,
E. Brianne,
A. Ebrahimi,
K. Gadow,
P. Göttlicher,
C. Günter,
O. Hartbrich,
B. Hermberg
, et al. (135 additional authors not shown)
Abstract:
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test be…
▽ More
The spatial development of hadronic showers in the CALICE scintillator-steel analogue hadron calorimeter is studied using test beam data collected at CERN and FNAL for single positive pions and protons with initial momenta in the range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron showers are parametrised with two-component functions. The parametrisation is fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics lists from Geant4 version 9.6. The parameters extracted from data and simulated samples are compared for the two types of hadrons. The response to pions and the ratio of the non-electromagnetic to the electromagnetic calorimeter response, h/e, are estimated using the extrapolation and decomposition of the longitudinal profiles.
△ Less
Submitted 15 March, 2016; v1 submitted 27 February, 2016;
originally announced February 2016.
-
First results of the CALICE SDHCAL technological prototype
Authors:
V. Buridon,
C. Combaret,
L. Caponetto,
R. Eté,
G. Garillot,
G. Grenier,
R. Han,
J. C. Ianigro,
R. Kieffer,
I. Laktineh,
N. Lumb,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
J. Berenguer Antequera,
E. Calvo Alamillo,
M. -C. Fouz,
J. Marin,
J. Puerta-Pelayo,
A. Verdugo,
E. Cortina Gil,
S. Mannai,
S. Cauwenbergh,
M. Tytgat
, et al. (96 additional authors not shown)
Abstract:
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDH…
▽ More
The CALICE Semi-Digital Hadronic Calorimeter (SDHCAL) prototype, built in 2011, was exposed to beams of hadrons, electrons and muons in two short periods in 2012 on two different beam lines of the CERN SPS. The prototype with its 48 active layers, made of Glass Resistive Plate Chambers and their embedded readout electronics, was run in triggerless and power-pulsing mode. The performance of the SDHCAL during the test beam was found to be very satisfactory with an efficiency exceeding 90% for almost all of the 48 active layers. A linear response (within 5%) and a good energy resolution are obtained for a large range of hadronic energies (5-80GeV) by applying appropriate calibration coefficients to the collected data for both the Digital (Binary) and the Semi-Digital (Multi-threshold) modes of the SDHCAL prototype. The Semi-Digital mode shows better performance at energies exceeding 30GeV
△ Less
Submitted 20 March, 2016; v1 submitted 6 February, 2016;
originally announced February 2016.
-
Reconstruction and classification of tau lepton decays with ILD
Authors:
Trong Hieu Tran,
Vladislav Balagura,
Vincent Boudry,
Jean-Claude Brient,
Henri Videau
Abstract:
Tau-lepton decays with up to two $π^0$'s in the final state, $τ^+ \to π^+ \barν_τ$, $ρ^+ (π^+π^0) \barν_τ$, $a^+_1 (π^+π^0π^0) \barν_τ$, are used to study the performance of the barrel part of the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) of the International Large Detector (ILD) at the future $e^+-e^-$ International Linear Collider. A correct reconstruction of the tau decay mode is…
▽ More
Tau-lepton decays with up to two $π^0$'s in the final state, $τ^+ \to π^+ \barν_τ$, $ρ^+ (π^+π^0) \barν_τ$, $a^+_1 (π^+π^0π^0) \barν_τ$, are used to study the performance of the barrel part of the silicon-tungsten electromagnetic calorimeter (Si-W ECAL) of the International Large Detector (ILD) at the future $e^+-e^-$ International Linear Collider. A correct reconstruction of the tau decay mode is crucial for constraining the tau spin state and measuring the Higgs boson CP state in $H\to τ^+τ^-$ decays. About 95% of $π^+ \barν_τ$ and 90% of $ρ^+\barν_τ$ and $a^+_1\barν_τ$ decays from $e^+e^-\to Z^0\to τ^+τ^-$ reaction at $e^\pm$-beam energy of 125 GeV are correctly reconstructed. In a smaller ILD detector, with Si-W ECAL radius reduced by about 20% these numbers degrade by at most 2%. The $π^0$ mass resolution stays below 10%. Since the failures in the tau-lepton reconstruction are mainly due to photons, the increase of the ILD magnetic field from 3.5 T to 4 T does not bring any significant improvement.
△ Less
Submitted 25 March, 2016; v1 submitted 18 October, 2015;
originally announced October 2015.
-
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
Authors:
The CALICE collaboration,
M. Chefdeville,
Y. Karyotakis,
J. Repond,
J. Schlereth,
L. Xia,
G. Eigen,
J. S. Marshall,
M. A. Thomson,
D. R. Ward,
N. Alipour Tehrani,
J. Apostolakis,
D. Dannheim,
K. Elsener,
G. Folger,
C. Grefe,
V. Ivantchenko,
M. Killenberg,
W. Klempt,
E. van der Kraaij,
L. Linssen,
A. -I. Lucaci-Timoce,
A. Münnich,
S. Poss,
A. Ribon
, et al. (158 additional authors not shown)
Abstract:
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolutio…
▽ More
We present a study of showers initiated by electrons, pions, kaons, and protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten analogue hadronic calorimeter. The data were recorded at the CERN Super Proton Synchrotron in 2011. The analysis includes measurements of the calorimeter response to each particle type as well as measurements of the energy resolution and studies of the longitudinal and radial shower development for selected particles. The results are compared to Geant4 simulations (version 9.6.p02). In the study of the energy resolution we include previously published data with beam momenta from 1 GeV to 10 GeV recorded at the CERN Proton Synchrotron in 2010.
△ Less
Submitted 11 December, 2015; v1 submitted 2 September, 2015;
originally announced September 2015.
-
Construction and commissioning of a technological prototype of a high-granularity semi-digital hadronic calorimeter
Authors:
G. Baulieu,
M. Bedjidian,
K. Belkadhi,
J. Berenguer,
V. Boudry,
P. Calabria,
S. Callier,
E. Calvo Almillo,
S. Cap,
L. Caponetto,
C. Combaret,
R. Cornat,
E. Cortina Gil,
B. de Callatay,
F. Davin,
C. de la Taille,
R. Dellanegra,
D. Delaunay,
F. Doizon,
F. Dulucq,
A. Eynard,
M-C. Fouz,
F. Gastaldi,
L. Germani,
G. Grenier
, et al. (21 additional authors not shown)
Abstract:
A large prototype of 1.3m3 was designed and built as a demonstrator of the semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC experiments. The prototype is a sampling hadronic calorimeter of 48 units. Each unit is built of an active layer made of 1m2 Glass Resistive Plate Chamber(GRPC) detector placed inside a cassette whose walls are made of stainless steel. The casset…
▽ More
A large prototype of 1.3m3 was designed and built as a demonstrator of the semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC experiments. The prototype is a sampling hadronic calorimeter of 48 units. Each unit is built of an active layer made of 1m2 Glass Resistive Plate Chamber(GRPC) detector placed inside a cassette whose walls are made of stainless steel. The cassette contains also the electronics used to read out the GRPC detector. The lateral granularity of the active layer is provided by the electronics pick-up pads of 1cm2 each. The cassettes are inserted into a self-supporting mechanical structure built also of stainless steel plates which, with the cassettes walls, play the role of the absorber. The prototype was designed to be very compact and important efforts were made to minimize the number of services cables to optimize the efficiency of the Particle Flow Algorithm techniques to be used in the future ILC experiments. The different components of the SDHCAL prototype were studied individually and strict criteria were applied for the final selection of these components. Basic calibration procedures were performed after the prototype assembling. The prototype is the first of a series of new-generation detectors equipped with a power-pulsing mode intended to reduce the power consumption of this highly granular detector. A dedicated acquisition system was developed to deal with the output of more than 440000 electronics channels in both trigger and triggerless modes. After its completion in 2011, the prototype was commissioned using cosmic rays and particles beams at CERN.
△ Less
Submitted 24 October, 2015; v1 submitted 15 June, 2015;
originally announced June 2015.
-
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
L. Xia,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh,
G. C. Blazey,
A. Dyshkant,
K. Francis,
J. G. R. Lima,
R. Salcido,
V. Zutshi,
F. Salvatore,
K. Kawagoe,
Y. Miyazaki,
Y. Sudo
, et al. (147 additional authors not shown)
Abstract:
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simul…
▽ More
Showers produced by positive hadrons in the highly granular CALICE scintillator-steel analogue hadron calorimeter were studied. The experimental data were collected at CERN and FNAL for single particles with initial momenta from 10 to 80 GeV/c. The calorimeter response and resolution and spatial characteristics of shower development for proton- and pion-induced showers for test beam data and simulations using Geant4 version 9.6 are compared.
△ Less
Submitted 15 March, 2015; v1 submitted 8 December, 2014;
originally announced December 2014.
-
Testing Hadronic Interaction Models using a Highly Granular Silicon-Tungsten Calorimeter
Authors:
The CALICE Collaboration,
B. Bilki,
J. Repond,
J. Schlereth,
L. Xia,
Z. Deng,
Y. Li,
Y. Wang,
Q. Yue,
Z. Yang,
G. Eigen,
Y. Mikami,
T. Price,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
C. Cârloganu,
S. Chang,
A. Khan,
D. H. Kim,
D. J. Kong,
Y. D. Oh
, et al. (127 additional authors not shown)
Abstract:
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable ove…
▽ More
A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon-tungsten electromagnetic calorimeter. Approximately 350,000 selected negatively charged pion events at energies between 2 and 10 GeV have been studied. The predictions of several physics models available within the Geant4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
△ Less
Submitted 8 May, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
Software digitizer for high granular gaseous detector
Authors:
Y. Haddad,
M. Ruan,
V. Boudry
Abstract:
A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout pad dimension and size and almost insensitive to neutrons. The response of a finely segmented digital calorimeter is characterized by track efficiency and multip…
▽ More
A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout pad dimension and size and almost insensitive to neutrons. The response of a finely segmented digital calorimeter is characterized by track efficiency and multiplicity. Monte Carlo (MC) programs such as GEANT4 simulate with high precision the energy deposited by particles. The sensor and electronic response associated to a pad are calculated in a separate "digitization" process. We developed a general method for simulating the pad response, a digitization, reproducing efficiency and multiplicity, using the spatial information from a simulation done at higher granularity. The digitization method proposed here has been applied to gaseous detectors including Glass Resistive Plate Chambers (GRPC) and MicroMegas. Validating the method on test beam data, experimental observables such as efficiency, multiplicity and mean number of hits at different thresholds have been reproduced with high precision.
△ Less
Submitted 6 May, 2014;
originally announced May 2014.
-
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters J. Repond,
J. Schlereth,
L. Xia E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki J. Apostolakis,
S. Arfaoui,
M. Benoit
, et al. (188 additional authors not shown)
Abstract:
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m…
▽ More
The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is measured on a statistical basis with high spatial and temporal resolution in sampling calorimeters with tungsten and steel absorbers. The results are compared to GEANT4 (version 9.4 patch 03) simulations with different hadronic physics models. These comparisons demonstrate the importance of using high precision treatment of low-energy neutrons for tungsten absorbers, while an overall good agreement between data and simulations for all considered models is observed for steel.
△ Less
Submitted 21 July, 2014; v1 submitted 25 April, 2014;
originally announced April 2014.
-
Fractal Dimension of Particle Showers Measured in a Highly Granular Calorimeter
Authors:
Manqi Ruan,
Daniel Jeans,
Vincent Boudry,
Jean-Claude Brient,
Henri Videau
Abstract:
We explore the fractal nature of particle showers using Monte-Carlo simulation. We define the fractal dimension of showers measured in a high granularity calorimeter designed for a future lepton collider. The shower fractal dimension reveals detailed information of the spatial configuration of the shower. %the information hidden in the details of shower spatial configuration, It is found to be cha…
▽ More
We explore the fractal nature of particle showers using Monte-Carlo simulation. We define the fractal dimension of showers measured in a high granularity calorimeter designed for a future lepton collider. The shower fractal dimension reveals detailed information of the spatial configuration of the shower. %the information hidden in the details of shower spatial configuration, It is found to be characteristic of the type of interaction and highly sensitive to the nature of the incident particle. Using the shower fractal dimension, we demonstrate a particle identification algorithm that can efficiently separate electromagnetic showers, hadronic showers and non-showering tracks. We also find a logarithmic dependence of the shower fractal dimension on the particle energy.
△ Less
Submitted 30 December, 2013;
originally announced December 2013.
-
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
Authors:
CALICE Collaboration,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada,
Y. Khoulaki,
J. Apostolakis,
A. Dotti,
G. Folger,
V. Ivantchenko,
A. Ribon
, et al. (169 additional authors not shown)
Abstract:
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur…
▽ More
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
△ Less
Submitted 11 June, 2014; v1 submitted 15 November, 2013;
originally announced November 2013.
-
Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL
Authors:
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
M. A. Thomson,
D. R. Ward,
D. Benchekroun,
A. Hoummada
, et al. (194 additional authors not shown)
Abstract:
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain hig…
▽ More
Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain high-energy showers, while allowing a compact size for the surrounding solenoid.
A fine-grained calorimeter prototype with tungsten absorber plates and scintillator tiles read out by silicon photomultipliers was built and exposed to particle beams at CERN. Results obtained with electrons, pions and protons of momenta up to 10 GeV are presented in terms of energy resolution and shower shape studies. The results are compared with several GEANT4 simulation models in order to assess the reliability of the Monte Carlo predictions relevant for a future experiment at CLIC.
△ Less
Submitted 13 January, 2014; v1 submitted 14 November, 2013;
originally announced November 2013.
-
Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (148 additional authors not shown)
Abstract:
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are…
▽ More
Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.
△ Less
Submitted 15 June, 2014; v1 submitted 13 June, 2013;
originally announced June 2013.
-
Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter
Authors:
CALICE Collaboration,
C. Adloff,
J. -J. Blaising,
M. Chefdeville,
C. Drancourt,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
I. Koletsou,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Schlereth,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (184 additional authors not shown)
Abstract:
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul…
▽ More
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.
△ Less
Submitted 29 July, 2013; v1 submitted 30 May, 2013;
originally announced May 2013.
-
Druid, event display for the linear collider
Authors:
Manqi Ruan,
Vincent Boudry,
Gabriel Musat,
Daniel Jeans,
Jayant Pande
Abstract:
Druid is a dedicated event display designed for the future electron positron linear colliders. Druid takes standard linear collider data files and detector geometry description files as input, it can visualize both physics event and detector geometry. Many displaying options are provided by Druid, giving easy access to different information. As a versatile event display, Druid supports all the lat…
▽ More
Druid is a dedicated event display designed for the future electron positron linear colliders. Druid takes standard linear collider data files and detector geometry description files as input, it can visualize both physics event and detector geometry. Many displaying options are provided by Druid, giving easy access to different information. As a versatile event display, Druid supports all the latest linear collider detector models, Silicon Detector and International Large Detector, as well as the calorimeter prototypes operated in the CALICE test beam experiments. It has been utilized in many studies such as the verification of detector geometry, analysis of the simulated full events and test beam data as well as reconstruction algorithm development and code debugging.
△ Less
Submitted 15 March, 2013;
originally announced March 2013.
-
Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques
Authors:
CALICE Collaboration,
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
T. Buanes,
G. Eigen,
Y. Mikami,
N. K. Watson
, et al. (142 additional authors not shown)
Abstract:
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advan…
▽ More
The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advantage of the event-by-event information about the substructure of hadronic showers which is provided by the imaging capabilities of the calorimeter. The energy reconstruction is improved either with corrections based on the local energy density or by applying a single correction factor to the event energy sum derived from a global measure of the shower energy density. The application of the compensation algorithms to Geant4 simulations yield resolution improvements comparable to those observed for real data.
△ Less
Submitted 27 September, 2012; v1 submitted 17 July, 2012;
originally announced July 2012.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Electromagnetic response of a highly granular hadronic calorimeter
Authors:
C. Adloff,
J. Blaha,
J. -J. Blaising,
C. Drancourt,
A. Espargilière,
R. Gaglione,
N. Geffroy,
Y. Karyotakis,
J. Prast,
G. Vouters,
K. Francis,
J. Repond,
J. Smith,
L. Xia,
E. Baldolemar,
J. Li,
S. T. Park,
M. Sosebee,
A. P. White,
J. Yu,
Y. Mikami,
N. K. Watson T. Goto,
G. Mavromanolakis,
M. A. Thomson,
D. R. Ward W. Yan
, et al. (142 additional authors not shown)
Abstract:
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individuall…
▽ More
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM).
A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes.
The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.
△ Less
Submitted 8 June, 2011; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Performance of Glass Resistive Plate Chambers for a high granularity semi-digital calorimeter
Authors:
M. Bedjidian,
K. Belkadhi,
V. Boudry,
C. Combaret,
D. Decotigny,
E. Cortina Gil,
C. de la Taille,
R. Dellanegra,
V. A. Gapienko,
G. Grenier,
C. Jauffret,
R. Kieffer,
M. -C. Fouz,
R. Han,
I. Laktineh,
N. Lumb,
K. Manai,
S. Mannai,
H. Mathez,
L. Mirabito,
J. Puerta Pelayo,
M. Ruan,
F. Schirra,
N. Seguin-Moreau,
W. Tromeur
, et al. (3 additional authors not shown)
Abstract:
A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold semi-digital read-out. Several GRPC prototypes with their electronics have been successfully built and tested in pion beams. The design of these detectors is presen…
▽ More
A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold semi-digital read-out. Several GRPC prototypes with their electronics have been successfully built and tested in pion beams. The design of these detectors is presented along with the test results on efficiency, pad multiplicity, stability and reproducibility.
△ Less
Submitted 30 December, 2010; v1 submitted 27 November, 2010;
originally announced November 2010.
-
Summary of the Linear Collider Testbeam Workshop 2009 - LCTW09
Authors:
V. Boudry,
G. Fisk,
R. E. Frey,
F. Gaede,
C. Hast,
J. Hauptman,
K. Kawagoe,
L. Linssen,
R. Lipton,
W. Lohmann,
T. Matsuda,
T. Nelson,
R. Poeschl,
E. Ramberg,
F. Sefkow,
M. Vos,
M. Wing,
J. Yu
Abstract:
This note summarises the workshop LCTW09 held between the 3.11.2009 and 5.11.2009 at LAL Orsay. The workshop was dedicated to discuss the beam tests in the years 2010 up to 2013 for detectors to be operated at a future linear electron positron collider. The document underlines the rich R&D program on these detectors in the coming years. Large synergies were identified in the DAQ and software syste…
▽ More
This note summarises the workshop LCTW09 held between the 3.11.2009 and 5.11.2009 at LAL Orsay. The workshop was dedicated to discuss the beam tests in the years 2010 up to 2013 for detectors to be operated at a future linear electron positron collider. The document underlines the rich R&D program on these detectors in the coming years. Large synergies were identified in the DAQ and software systems. Considerable consolidation of resources are expected from the establishment of semi-permanent beam lines for linear collider detector R&D at major centres like CERN and FNAL. Reproducing a beam structure as foreseen for the International Linear Collider (ILC) would clearly enhance the value of the obtained beam test results. Although not ultimately needed for every research program, all groups would exploit such a feature if it is available.
△ Less
Submitted 7 October, 2010;
originally announced October 2010.
-
Test beam studies for a highly granular GRPC Semi-Digital HCAL
Authors:
Vincent Boudry
Abstract:
The Particle Flow Analysis approach retained for the future ILC detectors requires high granularity and compact particle energy deposition. A Glass Resistive Plate Chamber based Semi-Digital calorimeter can offer both at a low price for the hadronic section. This paper presents some recent developments and results near test beam in the use of Glass Resistive Plate Chamber with embedded front-end e…
▽ More
The Particle Flow Analysis approach retained for the future ILC detectors requires high granularity and compact particle energy deposition. A Glass Resistive Plate Chamber based Semi-Digital calorimeter can offer both at a low price for the hadronic section. This paper presents some recent developments and results near test beam in the use of Glass Resistive Plate Chamber with embedded front-end electronics to build a prototype based on this principle. All the critical parameters such as the spatial and angular uniformity of the response as well as the noise level have been measured on small chambers and found to be appropriate. Small semi-conductive chambers allowing for high rates and a large chamber have also been tested.
△ Less
Submitted 3 September, 2010;
originally announced September 2010.