Optimal binary gratings for multi-wavelength magneto-optical traps
Authors:
Oliver S. Burrow,
Robert J. Fasano,
Wesley Brand,
Michael W. Wright,
Wenbo Li,
Andrew D. Ludlow,
Erling Riis,
Paul F. Griffin,
Aidan S. Arnold
Abstract:
Grating magneto-optical traps are an enabling quantum technology for portable metrological devices with ultracold atoms. However, beam diffraction efficiency and angle are affected by wavelength, creating a single-optic design challenge for laser cooling in two stages at two distinct wavelengths - as commonly used for loading e.g. Sr or Yb atoms into optical lattice or tweezer clocks. Here, we opt…
▽ More
Grating magneto-optical traps are an enabling quantum technology for portable metrological devices with ultracold atoms. However, beam diffraction efficiency and angle are affected by wavelength, creating a single-optic design challenge for laser cooling in two stages at two distinct wavelengths - as commonly used for loading e.g. Sr or Yb atoms into optical lattice or tweezer clocks. Here, we optically characterize a wide variety of binary gratings at different wavelengths to find a simple empirical fit to experimental grating diffraction efficiency data in terms of dimensionless etch depth and period for various duty cycles. The model avoids complex 3D light-grating surface calculations, yet still yields results accurate to a few percent across a broad range of parameters. Gratings optimized for two (or more) wavelengths can now be designed in an informed manner suitable for a wide class of atomic species enabling advanced quantum technologies.
△ Less
Submitted 18 November, 2023; v1 submitted 29 June, 2023;
originally announced June 2023.
-
Characterization and suppression of background light shifts in an optical lattice clock
Authors:
R. J. Fasano,
Y. J. Chen,
W. F. McGrew,
W. J. Brand,
R. W. Fox,
A. D. Ludlow
Abstract:
Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have been especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today…
▽ More
Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have been especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today exploit Lamb-Dicke confinement in magic-wavelength optical traps, in some cases realizing shift cancellation at the ten parts per billion level. Theory and empirical measurements can be used at varying levels of precision to determine the magic wavelength where shift cancellation occurs. However, lasers exhibit background spectra from amplified spontaneous emission or other lasing modes which can easily contaminate measurement of the magic wavelength and its reproducibility in other experiments or conditions. Indeed, residual light shifts from laser background have plagued optical lattice clock measurements for years. In this work, we develop a simple theoretical model allowing prediction of light shifts from measured background spectra. We demonstrate good agreement between this model and measurements of the background light shift from an amplified diode laser in an Yb optical lattice clock. Additionally, we model and experimentally characterize the filtering effect of a volume Bragg grating bandpass filter, demonstrating that application of the filter can reduce background light shifts from amplified spontaneous emission well below the $10^{-18}$ fractional clock frequency level. This demonstration is corroborated by direct clock comparisons between a filtered amplified diode laser and a filtered titanium:sapphire laser.
△ Less
Submitted 22 March, 2021;
originally announced March 2021.
-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Modeling motional energy spectra and lattice light shifts in optical lattice clocks
Authors:
K. Beloy,
W. F. McGrew,
X. Zhang,
D. Nicolodi,
R. J. Fasano,
Y. S. Hassan,
R. C. Brown,
A. D. Ludlow
Abstract:
We develop a model to describe the motional (i.e., external degree of freedom) energy spectra of atoms trapped in a one-dimensional optical lattice, taking into account both axial and radial confinement relative to the lattice axis. Our model respects the coupling between axial and radial degrees of freedom, as well as other anharmonicities inherent in the confining potential. We further demonstra…
▽ More
We develop a model to describe the motional (i.e., external degree of freedom) energy spectra of atoms trapped in a one-dimensional optical lattice, taking into account both axial and radial confinement relative to the lattice axis. Our model respects the coupling between axial and radial degrees of freedom, as well as other anharmonicities inherent in the confining potential. We further demonstrate how our model can be used to characterize lattice light shifts in optical lattice clocks, including shifts due to higher multipolar (magnetic dipole and electric quadrupole) and higher order (hyperpolarizability) coupling to the lattice field. We compare results for our model with results from other lattice light shift models in the literature under similar conditions.
△ Less
Submitted 13 April, 2020;
originally announced April 2020.
-
Measurements of $^{27}$Al$^{+}$ and $^{25}$Mg$^{+}$ magnetic constants for improved ion clock accuracy
Authors:
S. M. Brewer,
J. -S. Chen,
K. Beloy,
A. M. Hankin,
E. R. Clements,
C. W. Chou,
W. F. McGrew,
X. Zhang,
R. J. Fasano,
D. Nicolodi,
H. Leopardi,
T. M. Fortier,
S. A. Diddams,
A. D. Ludlow,
D. J. Wineland,
D. R. Leibrandt,
D. B. Hume
Abstract:
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the…
▽ More
We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the $^{27}$Al$^{+}$ quantum-logic clock systematic uncertainty. The measurement of $C_{2}$ is in agreement with a previous measurement and a new calculation at the $1~σ$ level. The measurement of $ΔW$ is in good agreement with a recent measurement and differs from a previously published result by approximately $2σ$. With the improved value for $ΔW$, we deduce an improved value for the nuclear-to-electronic g-factor ratio $g_{I}/g_{J} = 9.299 ~308 ~313(60) \times 10^{-5}$ and the nuclear g-factor for the $^{25}$Mg nucleus $g_{I} = 1.861 ~957 ~82(28) \times 10^{-4}$. Using the values of $C_{2}$ and $ΔW$ presented here, we derive a quadratic Zeeman shift of the $^{27}$Al$^{+}$ quantum-logic clock of $Δν/ ν= -(9241.8 \pm 3.7) \times 10^{-19}$, for a bias magnetic field of $B \approx 0.12$~mT.
△ Less
Submitted 22 May, 2019; v1 submitted 11 March, 2019;
originally announced March 2019.
-
Optical-Clock-Based Time Scale
Authors:
Jian Yao,
Jeff A. Sherman,
Tara Fortier,
Holly Leopardi,
Thomas Parker,
William McGrew,
Xiaogang Zhang,
Daniele Nicolodi,
Robert Fasano,
Stefan Schäffer,
Kyle Beloy,
Joshua Savory,
Stefania Romisch,
Chris Oates,
Scott Diddams,
Andrew Ludlow,
Judah Levine
Abstract:
A time scale is a procedure for accurately and continuously marking the passage of time. It is exemplified by Coordinated Universal Time (UTC), and provides the backbone for critical navigation tools such as the Global Positioning System (GPS). Present time scales employ microwave atomic clocks, whose attributes can be combined and averaged in a manner such that the composite is more stable, accur…
▽ More
A time scale is a procedure for accurately and continuously marking the passage of time. It is exemplified by Coordinated Universal Time (UTC), and provides the backbone for critical navigation tools such as the Global Positioning System (GPS). Present time scales employ microwave atomic clocks, whose attributes can be combined and averaged in a manner such that the composite is more stable, accurate, and reliable than the output of any individual clock. Over the past decade, clocks operating at optical frequencies have been introduced which are orders of magnitude more stable than any microwave clock. However, in spite of their great potential, these optical clocks cannot be operated continuously, which makes their use in a time scale problematic. In this paper, we report the development of a hybrid microwave-optical time scale, which only requires the optical clock to run intermittently while relying upon the ensemble of microwave clocks to serve as the flywheel oscillator. The benefit of using clock ensemble as the flywheel oscillator, instead of a single clock, can be understood by the Dick-effect limit. This time scale demonstrates for the first time sub-nanosecond accuracy for a few months, attaining a fractional frequency uncertainty of 1.45*10-16 at 30 days and reaching the 10-17 decade at 50 days, with respect to UTC. This time scale significantly improves the accuracy in timekeeping and could change the existing time-scale architectures.
△ Less
Submitted 10 April, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit
Authors:
W. F. McGrew,
X. Zhang,
H. Leopardi,
R. J. Fasano,
D. Nicolodi,
K. Beloy,
J. Yao,
J. A. Sherman,
S. A. Schäffer,
J. Savory,
R. C. Brown,
S. Römisch,
C. W. Oates,
T. E. Parker,
T. M. Fortier,
A. D. Ludlow
Abstract:
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by compari…
▽ More
The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by comparing against a primary cesium reference. A key verification of this process can be achieved by performing a loop closure$-$comparing frequency ratios derived from absolute frequency measurements against ratios determined from direct optical comparisons. We measure the $^1$S$_0\!\rightarrow^3$P$_0$ transition of $^{171}$Yb by comparing the clock frequency to an international frequency standard with the aid of a maser ensemble serving as a flywheel oscillator. Our measurements consist of 79 separate runs spanning eight months, and we determine the absolute frequency to be 518 295 836 590 863.71(11) Hz, the uncertainty of which is equivalent to a fractional frequency of $2.1\times10^{-16}$. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty of $<$3$\times10^{-16}$, limited by the current realization of the SI second. We use these measurements to tighten the constraints on variation of the electron-to-proton mass ratio, $μ=m_e/m_p$. Incorporating our measurements with the entire record of Yb and Sr absolute frequency measurements, we infer a coupling coefficient to gravitational potential of $k_\mathrmμ=(-1.9\pm 9.4)\times10^{-7}$ and a drift with respect to time of $\frac{\dotμ}μ=(5.3 \pm 6.5)\times10^{-17}/$yr.
△ Less
Submitted 14 November, 2018;
originally announced November 2018.
-
Atomic clock performance beyond the geodetic limit
Authors:
W. F. McGrew,
X. Zhang,
R. J. Fasano,
S. A. Schäffer,
K. Beloy,
D. Nicolodi,
R. C. Brown,
N. Hinkley,
G. Milani,
M. Schioppo,
T. H. Yoon,
A. D. Ludlow
Abstract:
The passage of time is tracked by counting oscillations of a frequency reference, such as Earth's revolutions or swings of a pendulum. By referencing atomic transitions, frequency (and thus time) can be measured more precisely than any other physical quantity, with the current generation of optical atomic clocks reporting fractional performance below the $10^{-17}$ level. However, the theory of re…
▽ More
The passage of time is tracked by counting oscillations of a frequency reference, such as Earth's revolutions or swings of a pendulum. By referencing atomic transitions, frequency (and thus time) can be measured more precisely than any other physical quantity, with the current generation of optical atomic clocks reporting fractional performance below the $10^{-17}$ level. However, the theory of relativity prescribes that the passage of time is not absolute, but impacted by an observer's reference frame. Consequently, clock measurements exhibit sensitivity to relative velocity, acceleration and gravity potential. Here we demonstrate optical clock measurements surpassing the present-day ability to account for the gravitational distortion of space-time across the surface of Earth. In two independent ytterbium optical lattice clocks, we demonstrate unprecedented levels in three fundamental benchmarks of clock performance. In units of the clock frequency, we report systematic uncertainty of $1.4 \times 10^{-18}$, measurement instability of $3.2 \times 10^{-19}$ and reproducibility characterised by ten blinded frequency comparisons, yielding a frequency difference of $[-7 \pm (5)_{stat} \pm (8)_{sys}] \times 10^{-19}$. While differential sensitivity to gravity could degrade the performance of these optical clocks as terrestrial standards of time, this same sensitivity can be used as an exquisite probe of geopotential. Near the surface of Earth, clock comparisons at the $1 \times 10^{-18}$ level provide 1 cm resolution along gravity, outperforming state-of-the-art geodetic techniques. These optical clocks can further be used to explore geophysical phenomena, detect gravitational waves, test general relativity and search for dark matter.
△ Less
Submitted 30 July, 2018;
originally announced July 2018.
-
First observation with global network of optical atomic clocks aimed for a dark matter detection
Authors:
P. Wcisło,
P. Ablewski,
K. Beloy,
S. Bilicki,
M. Bober,
R. Brown,
R. Fasano,
R. Ciuryło,
H. Hachisu,
T. Ido,
J. Lodewyck,
A. Ludlow,
W. McGrew,
P. Morzyński,
D. Nicolodi,
M. Schioppo,
M. Sekido,
R. Le Targat,
P. Wolf,
X. Zhang,
B. Zjawin,
M. Zawada
Abstract:
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comp…
▽ More
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comparisons of the clocks. We report a two orders of magnitude improvement in constraints on transient variations of the fine-structure constant, which considerably improves the detection limit for the standard model (SM) - DM coupling. We use Yb and Sr optical atomic clocks at four laboratories on three continents to search for both topological defect (TD) and massive scalar field candidates. No signal consistent with a dark-matter coupling is identified, leading to significantly improved constraints on the DM-SM couplings.
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
Faraday-shielded, DC Stark-free optical lattice clock
Authors:
K. Beloy,
X. Zhang,
W. F. McGrew,
N. Hinkley,
T. H. Yoon,
D. Nicolodi,
R. J. Fasano,
S. A. Schäffer,
R. C. Brown,
A. D. Ludlow
Abstract:
We demonstrate the absence of a DC Stark shift in an ytterbium optical lattice clock. Stray electric fields are suppressed through the introduction of an in-vacuum Faraday shield. Still, the effectiveness of the shielding must be experimentally assessed. Such diagnostics are accomplished by applying high voltage to six electrodes, which are grounded in normal operation to form part of the Faraday…
▽ More
We demonstrate the absence of a DC Stark shift in an ytterbium optical lattice clock. Stray electric fields are suppressed through the introduction of an in-vacuum Faraday shield. Still, the effectiveness of the shielding must be experimentally assessed. Such diagnostics are accomplished by applying high voltage to six electrodes, which are grounded in normal operation to form part of the Faraday shield. Our measurements place a constraint on the DC Stark shift at the $10^{-20}$ level, in units of the clock frequency. Moreover, we discuss a potential source of error in strategies to precisely measure or cancel non-zero DC Stark shifts, attributed to field gradients coupled with the finite spatial extent of the lattice-trapped atoms. With this consideration, we find that Faraday shielding, complemented with experimental validation, provides both a practically appealing and effective solution to the problem of DC Stark shifts in optical lattice clocks.
△ Less
Submitted 28 March, 2018;
originally announced March 2018.
-
Hyperpolarizability and operational magic wavelength in an optical lattice clock
Authors:
R. C. Brown,
N. B. Phillips,
K. Beloy,
W. F. McGrew,
M. Schioppo,
R. J. Fasano,
G. Milani,
X. Zhang,
N. Hinkley,
H. Leopardi,
T. H. Yoon,
D. Nicolodi,
T. M. Fortier,
A. D. Ludlow
Abstract:
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentall…
▽ More
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an $^{171}$Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the $10^{-18}$ level and beyond.
△ Less
Submitted 24 October, 2017; v1 submitted 29 August, 2017;
originally announced August 2017.
-
Ultra-stable optical clock with two cold-atom ensembles
Authors:
M. Schioppo,
R. C. Brown,
W. F. McGrew,
N. Hinkley,
R. J. Fasano,
K. Beloy,
T. H. Yoon,
G. Milani,
D. Nicolodi,
J. A. Sherman,
N. B. Phillips,
C. W. Oates,
A. D. Ludlow
Abstract:
Atomic clocks based on optical transitions are the most stable, and therefore precise, timekeepers available. These clocks operate by alternating intervals of atomic interrogation with dead time required for quantum state preparation and readout. This non-continuous interrogation of the atom system results in the Dick effect, an aliasing of frequency noise of the laser interrogating the atomic tra…
▽ More
Atomic clocks based on optical transitions are the most stable, and therefore precise, timekeepers available. These clocks operate by alternating intervals of atomic interrogation with dead time required for quantum state preparation and readout. This non-continuous interrogation of the atom system results in the Dick effect, an aliasing of frequency noise of the laser interrogating the atomic transition. Despite recent advances in optical clock stability achieved by improving laser coherence, the Dick effect has continually limited optical clock performance. Here we implement a robust solution to overcome this limitation: a zero-dead-time optical clock based on the interleaved interrogation of two cold-atom ensembles. This clock exhibits vanishingly small Dick noise, thereby achieving an unprecedented fractional frequency instability of $6 \times 10^{-17} / \sqrtτ$ for an averaging time $τ$ in seconds. We also consider alternate dual-atom-ensemble schemes to extend laser coherence and reduce the standard quantum limit of clock stability, achieving a spectroscopy line quality factor $Q> 4 \times 10^{15}$.
△ Less
Submitted 22 July, 2016;
originally announced July 2016.