Ali Salem

    Ali Salem

    This paper presents a new investigation to detect various faults within the three-phase star and delta induction motors (IMs) using a frequency response analysis (FRA). In this regard, experimental measurements using FRA are performed on... more
    This paper presents a new investigation to detect various faults within the three-phase star and delta induction motors (IMs) using a frequency response analysis (FRA). In this regard, experimental measurements using FRA are performed on three IMs of ratings 1 HP, 3 HP and 5.5 HP in normal conditions, short-circuit fault (SC) and open-circuit fault (OC) conditions. The SC and OC faults are applied artificially between the turns (Turn-to-Turn), between the coils (Coil-to-Coil) and between the phases (Phase-to-Phase). The obtained measurements show that the star and delta IMs result in dissimilar FRA signatures for the normal and faulty windings. Various statistical indicators are used to quantify the deviations between the normal and faulty FRA signatures. The calculation is performed in three frequency ranges: low, middle and high ones, as the winding parameters including resistive, inductive and capacitive components dominate the frequency characteristics at different frequency ran...
    Arsenic occurrence and toxicity records in various industrial effluents have prompted researchers to find cost-effective, quick, and efficient methods for removing arsenic from the environment. Adsorption of As(V) onto dried bacterial... more
    Arsenic occurrence and toxicity records in various industrial effluents have prompted researchers to find cost-effective, quick, and efficient methods for removing arsenic from the environment. Adsorption of As(V) onto dried bacterial biomass is proposed in the current work, which continues a line of previous research. Dried bacterial biomass of WS3 (DBB) has been examined for its potential to remove As(V) ions from aqueous solutions under various conditions. Under optimal conditions, an initial concentration of 7.5 ppm, pH 7, adsorbent dose of 0.5 mg, and contact period of 8 h at 37 °C results in maximum removal of 94%. Similarly, amine, amide, and hydroxyl groups were shown to contribute to As(V) removal by Fourier transform infrared spectroscopy (FTIR), and the adsorption of As(V) in the cell wall of DBB was verified by FESEM-EDX. In addition, equilibrium adsorption findings were analyzed using nonlinear and linear isotherms and kinetics models. The predicted best-fit model was s...
    Insulator monitoring using leakage current characteristics is essential for predicting an insulator’s health. To evaluate the risk of flashover on the porcelain insulator using leakage current, experimental investigation of leakage... more
    Insulator monitoring using leakage current characteristics is essential for predicting an insulator’s health. To evaluate the risk of flashover on the porcelain insulator using leakage current, experimental investigation of leakage current indices was carried out. In the first stage of the experiment, the effect of contamination, insoluble deposit density, wetting rate, and uneven distribution pollution were determined on the porcelain insulator under test. Then, based on the laboratory test results, leakage current information in time and frequency characteristics was extracted and employed as assessment indicators for the insulator’s health. Six indicators, namely, peak current indicator, phase shift indicator, slope indicator, crest factor indicator, total harmonic distortion indicator, and odd harmonics indicator, are introduced in this work. The obtained results indicated that the proposed indicators had a significant role in evaluating the insulator’s health. To evaluate the i...
    Frequency Response Analysis (FRA) technique has been recognized by worldwide utilities as a matured technology to assess the mechanical integrity of power transformers. While some industrial critical assets such as induction motors have... more
    Frequency Response Analysis (FRA) technique has been recognized by worldwide utilities as a matured technology to assess the mechanical integrity of power transformers. While some industrial critical assets such as induction motors have the same construction principle as power transformers, the application of FRA technique to induction motors has not yet been fully explored. This paper presents analogical experimental studies for the application of FRA on power transformers and induction motors. For a consistent analogy, the FRA technique has been employed to detect short and open circuit turns in both appliances, which helps explore a wider scope of the FRA applications on rotating machines. In this regard, experimental FRA measurements are performed on an 11/0.415 kV, 500 kVA, three-phase distribution transformer and a 5.5 HP three-phase induction motor. Several short and open circuit faults are staged on the windings of both tested equipment and the FRA signature is recorded and ...
    The monitoring of leakage current (LC) and voltage characteristics in transmission line insulators is regarded as a good technique for anticipating the physical state of in-service insulators. In the current work, the temporal and... more
    The monitoring of leakage current (LC) and voltage characteristics in transmission line insulators is regarded as a good technique for anticipating the physical state of in-service insulators. In the current work, the temporal and frequency characteristics of LC and voltage under various situations were derived for assessing the health condition of porcelain, glass, and silicone rubber insulators. The contamination severity indicated by soluble deposit density, wetting level (Wt), non-soluble deposit density, and uneven pollution distribution (Pu/PL) were chosen as the environmental factors that impact the insulators. Six criteria were utilized to evaluate the physical state of the insulators, with four of those derived from the LC signal in the time domain, namely, the LC signal peak (C1), the phase shift between applied voltage and LC (C2), the LC signal slope between two consecutive peaks (C3), and the crest factor (C4). The remaining two indices, namely, the total harmonics dist...
    SONAR signal processing plays an indispensable role when it comes to parameter estimation of Direction of Arrival (DOA) of acoustic plane waves for closely spaced target exclusively under severe noisy environments. Resolution performance... more
    SONAR signal processing plays an indispensable role when it comes to parameter estimation of Direction of Arrival (DOA) of acoustic plane waves for closely spaced target exclusively under severe noisy environments. Resolution performance of classical MUSIC and ESPRIT algorithms and other subspace-based algorithms decreases under scenarios like low SNR, smaller number of snapshots and closely spaced targets. In this study, optimization strength of swarm intelligence of Cuckoo Search Algorithm (CSA) is accomplished for viable DOA estimation in different scenarios of underwater environment using a Uniform Linear Array (ULA). Higher resolution for closely spaced targets is achieved using smaller number of snapshots viably with CSA by investigating global minima of the highly nonlinear cost function of ULA. Performance analysis of CSA for different number of targets employing estimation accuracy, higher resolution, variance analysis, frequency distribution of RMSE over the monte Carlo ru...
    Due to the constant need to enhance water supply sources, water operators are searching for solutions to maintain water quality through leakage protection. The capability to monitor the day-to-day water supply management is one of the... more
    Due to the constant need to enhance water supply sources, water operators are searching for solutions to maintain water quality through leakage protection. The capability to monitor the day-to-day water supply management is one of the most significant operational challenges for water companies. These companies are looking for ways to predict how to improve their supply operations in order to remain competitive, given the rising demand. This work focuses on the mathematical modeling of water flow and losses through leak openings in the smart pipe system. The research introduces smart mathematical models that water companies may use to predict water flow, losses, and performance, thereby allowing issues and challenges to be effectively managed. So far, most of the modeling work in water operations has been based on empirical data rather than mathematically described process relationships, which is addressed in this study. Moreover, partial submersion had a power relationship, but a to...
    In this paper, a unique approach based on electrical characteristics observed from measurements of contaminated polymeric insulators was established to calculate the electric field distribution over their surfaces. A case study using two... more
    In this paper, a unique approach based on electrical characteristics observed from measurements of contaminated polymeric insulators was established to calculate the electric field distribution over their surfaces. A case study using two different 33 kV polymeric insulator geometric profiles was performed to highlight the benefits of the proposed modeling approach. The conductance of the pollution layer was tested to establish a nonlinear field-dependent conductivity for pollution modeling. The leakage current (LC) of the polluted insulator was measured in a laboratory under clean and wet conditions. Then, using the finite element method (FEM), the electric field and current density distributions along the insulator were computed. The results showed that the insulators experienced an increase in the electric field (EF) magnitude ranging from 0.3 kV/cm to 3.6 kV/cm for the insulator with similar sheds (type I) and 2.2–4.5 kV/cm for the insulator with alternating sheds (big and small,...
    The industry has widely accepted Frequency Response Analysis (FRA) as a reliable method to detect power transformers mechanical deformations. While the FRA technique has been recommended in recent literature as a potential diagnostic... more
    The industry has widely accepted Frequency Response Analysis (FRA) as a reliable method to detect power transformers mechanical deformations. While the FRA technique has been recommended in recent literature as a potential diagnostic method to detect internal faults within rotating machines, detailed feasibility studies have not been fully addressed yet. This paper investigates the feasibility of using the FRA technique to detect several short circuit faults in the stator winding of three-phase induction motors (TPIMs). In this regard, FRA testing is conducted on two sets of induction motors with various short circuit faults. Investigated faults include short circuits between two phases, short circuit turns within the same phase, phase-to-ground, and phase-to-neutral short circuit. The measured FRA signatures are divided into three frequency ranges: low, medium, and high. Several statistical indicators are employed to quantify the variation between faulty and healthy signatures in e...
    The current work contributes an estimate of the time-frequency characteristics of a leakage current in assessing the health condition of a polluted polymeric insulator. A 33 kV polymer insulator string was subjected to a series of... more
    The current work contributes an estimate of the time-frequency characteristics of a leakage current in assessing the health condition of a polluted polymeric insulator. A 33 kV polymer insulator string was subjected to a series of laboratory tests under a range of environmental conditions, including pollution, wetting rate (WR), non-soluble deposit density (NSDD), and non-uniform distribution pollution (FT/B). The temporal and frequency features of the leakage current were then extracted and used as assessment indicators for insulator conditions based on laboratory test findings. Two indices were generated from the leakage current waveform in the time domain: the curve slope index (F1), which is determined by measuring the inclination of the curve between two successive time peaks of the leakage current, and the crest factor indicator (F2). The frequency domain of the leakage current signal was used to calculate the other two indices. These are the odd harmonic indicators derived fr...
    In-depth understanding of the pollution problems such as dry bands and the polymeric aging process requires better determination of electric field strength and its distribution over the polymeric surface. To determine the electric field... more
    In-depth understanding of the pollution problems such as dry bands and the polymeric aging process requires better determination of electric field strength and its distribution over the polymeric surface. To determine the electric field distribution over the insulator surface, this research proposes utilizing a novel approach model based on nonlinear electrical characteristics derived from experimental results for polluted polymer insulators. A case study was carried out for a typical 11 kV polymeric insulator to underline the merits of this new modeling approach. The developments of the proposed pollution model and the subsequent computational works are described in detail. The study is divided into two main stages; laboratory measurements and computer simulations. In the first stage, layer conductance tests were carried out to develop nonlinear field-dependent conductivity for the pollution modeling. In the second part, equipotential and electric field distributions along the leak...
    Based on experiments and numerical analysis techniques, this paper aims to investigate the influence of the four different coating damage profiles on the performance of coated 33 kV porcelain insulator strings under polluted and clean... more
    Based on experiments and numerical analysis techniques, this paper aims to investigate the influence of the four different coating damage profiles on the performance of coated 33 kV porcelain insulator strings under polluted and clean surface conditions. The performance of the insulators coated with room temperature vulcanizing (RTV) under partial coating damage and undamaged coating was evaluated. The influence of humidity on pollution flashover was taken into consideration. The ring-shaped, fan-shaped, and random-shaped coating was applied following coating damage. The results showed that the flashover characteristic of the RTV-coated insulators had a significant difference as compared to the normal insulators. Electrical characteristics such as the flashover voltage, critical current, and surface resistance were significantly affected by coating damage distribution and humidity level on the insulators’ surface. The electric field and potential difference were analyzed as well usi...
    This paper presents an alternative approach for predicting critical voltage of pollution flashover by using Artificial Intelligence (AI) technique. Data from experimental works combined with the theoretical results from well-known... more
    This paper presents an alternative approach for predicting critical voltage of pollution flashover by using Artificial Intelligence (AI) technique. Data from experimental works combined with the theoretical results from well-known theoretical modelling are used to derive algorithm for Artificial Neural Network (ANN) and Adaptive Neuro-fuzzy Inference System (ANFIS) for determining critical voltage of flashover. Series of laboratory testing and measurement are carried for 1:1, 1:5 and 1:10 ratios of top to bottom surface salt deposit density on cup and pin insulators. Insulators variables such as height H, diameter D, form factor F, creepage distance L, equivalent salt deposit density (ESDD) and flashover voltage correction are identified and used to train the AI network. Comparative studies have evidently shown that the proposed (AI) technique gives the satisfactory results compared to the analytical model and test data with the Coefficient of determination R-Square value of more th...
    Frequency response analysis (FRA) method has been proven to detect the transformer winding damage. However, there is no practical study which investigates the damages on transformer tap changer even though it has a high failure rate.... more
    Frequency response analysis (FRA) method has been proven to detect the transformer winding damage. However, there is no practical study which investigates the damages on transformer tap changer even though it has a high failure rate. Hence, this paper investigates normal and faulty transformer tap changer using FRA. The FRA measurements conducted using four different test configurations. Also, normal tap changer, pitting and coking tap changer contact were investigated. In addition to FRA measurement, winding resistance measurement has been conducted. The transformer turn ratio measurement also conducted to identify the taps positions. This study results significant to understand the effect of pitting and coking tap changer on the transformer frequency response. The results showed that pitting has a slight influence on the frequency response. However, coking shows a huge variation in low-frequency response. This effect observed during the winding resistance measurement.
    Glass insulators, due to its diverse characteristics, were used widely around the world for high voltage transmission lines. Surfaces of the insulators are exposed to high electrical, mechanical, and thermal stresses over the period of... more
    Glass insulators, due to its diverse characteristics, were used widely around the world for high voltage transmission lines. Surfaces of the insulators are exposed to high electrical, mechanical, and thermal stresses over the period of service. Accumulation of contamination distort stresses distribution along the insulators that may lead to flashover under severe condition. In this paper, Obenaus pollution model has been adopted to propose a dynamic mathematical modelling to determine flashover critical voltage with regard to parameters such as pollution conductivity, arc length, and width of layer of contamination on the surface of glass insulator. In addition, laboratory experimental works have been carried out according to IEC60305 to validate the results from numerical approach, which indicate a good agreement.
    Glass insulators, due to its diverse characteristics, were used widely around the world for high voltage transmission lines. Surfaces of the insulators are exposed to high electrical, mechanical, and thermal stresses over the period of... more
    Glass insulators, due to its diverse characteristics, were used widely around the world for high voltage transmission lines. Surfaces of the insulators are exposed to high electrical, mechanical, and thermal stresses over the period of service. Accumulation of contamination distort stresses distribution along the insulators that may lead to flashover under severe condition. In this paper, Obenaus pollution model has been adopted to propose a dynamic mathematical modelling to determine flashover critical voltage with regard to parameters such as pollution conductivity, arc length, and width of layer of contamination on the surface of glass insulator. In addition, laboratory experimental works have been carried out according to IEC60305 to validate the results from numerical approach, which indicate a good agreement.