Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

    Madalina Chirila

    Thermally stimulated luminescence (TSL), optical absorption, and electron paramagnetic resonance (EPR) have been used to characterize the emission of ultraviolet light from undoped LiTaO3. The crystals in this study were grown from a... more
    Thermally stimulated luminescence (TSL), optical absorption, and electron paramagnetic resonance (EPR) have been used to characterize the emission of ultraviolet light from undoped LiTaO3. The crystals in this study were grown from a congruent melt and then subjected to a vapor-transport-equilibration (VTE) treatment. Two overlapping TSL peaks occur at 94 and 98 K, with each showing a 350 nm maximum
    The American Conference of Governmental Industrial Hygienists (ACGIH) accepted a lower threshold limit value (TLV) for respirable crystalline silica (RCS) exposure of 25 μg/m(3), half of the previous TLV. This change is problematic... more
    The American Conference of Governmental Industrial Hygienists (ACGIH) accepted a lower threshold limit value (TLV) for respirable crystalline silica (RCS) exposure of 25 μg/m(3), half of the previous TLV. This change is problematic because the current standard sampling and measurement practices used by NIOSH, OSHA, and MSHA are not sensitive enough to allow an analyst to confidently determine samples acquired near the TLV. In response to this need for a more sensitive method to analyze respirable dust filter samples for crystalline silica, a modification of current NIOSH infrared spectrometric methods is being developed. The additional sensitivity is gained by performing the infrared absorbance measurements at 77 K where absorbance peaks are more intense by virtue of being narrower. A quick-change cryostat has been fabricated such that a sample can be introduced to the spectrometer and cooled to 77 K in 5 min, interrogated for 1 min, and removed and the cryostat readied for another sample in 2 min, for a turnaround time of 8 min per sample, which is brief compared to the time required to prepare and redeposit a sample. Therefore, samples can be acquired and interrogated with legacy samplers, filters, pumps, spectrometers, and sample preparation, the only modification being the addition of a cryostat to the spectrometer. Preliminary experiments demonstrate that the peak-to-background ratio of the quartz signature band near 800 cm(-1) increases by approximately 50 % on cooling from room temperature to 77 K. The slopes of the calibration curve derived from standards interrogated at both room temperature and 77 K indicate that the low-temperature method is approximately 25 % more sensitive.
    ... Page 2. ABSTRACT Characterization of Point Defects in Nonlinear Optical MaterialsMadalina M. Chirila ... A broad TL emission, peaking at 440 nm, is observed near 94 K from LiNbO3 when the crystal is irradiated at 77 K and then rapidly... more
    ... Page 2. ABSTRACT Characterization of Point Defects in Nonlinear Optical MaterialsMadalina M. Chirila ... A broad TL emission, peaking at 440 nm, is observed near 94 K from LiNbO3 when the crystal is irradiated at 77 K and then rapidly warmed. ...
    Research Interests:
    ABSTRACT
    The current measurement method for occupational exposure to wood dust is by gravimetric analysis and is thus non-specific. In this work, diffuse reflection infrared Fourier transform spectroscopy (DRIFTS) for the analysis of only the wood... more
    The current measurement method for occupational exposure to wood dust is by gravimetric analysis and is thus non-specific. In this work, diffuse reflection infrared Fourier transform spectroscopy (DRIFTS) for the analysis of only the wood component of dust was further evaluated by analysis of the same samples between two laboratories. Field samples were collected from six wood product factories using 25-mm glass fiber filters with the Button aerosol sampler. Gravimetric mass was determined in one laboratory by weighing the filters before and after aerosol collection. Diffuse reflection mid-infrared spectra were obtained from the wood dust on the filter which is placed on a motorized stage inside the spectrometer. The metric used for the DRIFTS analysis was the intensity of the carbonyl band in cellulose and hemicellulose at ~1735cm(-1). Calibration curves were constructed separately in both laboratories using the same sets of prepared filters from the inhalable sampling fraction of red oak, southern yellow pine, and western red cedar in the range of 0.125-4mg of wood dust. Using the same procedure in both laboratories to build the calibration curve and analyze the field samples, 62.3% of the samples measured within 25% of the average result with a mean difference between the laboratories of 18.5%. Some observations are included as to how the calibration and analysis can be improved. In particular, determining the wood type on each sample to allow matching to the most appropriate calibration increases the apparent proportion of wood dust in the sample and this likely provides more realistic DRIFTS results.
    ... Page 2. ABSTRACT Characterization of Point Defects in Nonlinear Optical MaterialsMadalina M. Chirila ... A broad TL emission, peaking at 440 nm, is observed near 94 K from LiNbO3 when the crystal is irradiated at 77 K and then rapidly... more
    ... Page 2. ABSTRACT Characterization of Point Defects in Nonlinear Optical MaterialsMadalina M. Chirila ... A broad TL emission, peaking at 440 nm, is observed near 94 K from LiNbO3 when the crystal is irradiated at 77 K and then rapidly warmed. ...
    ABSTRACT
    Production and thermal decay of radiation-induced point defects in KDPO crystals. [Journal of Applied Physics 94, 6456 (2003)]. MM Chirila, NY Garces, LE Halliburton, SG Demos, TA Land, HB Radousky. Abstract. Optical absorption ...
    An optical absorption investigation from 10 to 296 K has been performed on bulk crystals of ZnGeP2 grown by the horizontal-gradient-freeze method. We identify three broad absorption bands in the spectral range from 1 to 4 μm that are due... more
    An optical absorption investigation from 10 to 296 K has been performed on bulk crystals of ZnGeP2 grown by the horizontal-gradient-freeze method. We identify three broad absorption bands in the spectral range from 1 to 4 μm that are due to native defects. At low temperature, a band peaking near 1.2 μm and another band peaking near 2.2 μm have
    Thermoluminescence (TL), optical absorption, and electron paramagnetic resonance (EPR) have been used to characterize point defects in Mg-doped stoichiometric LiNbO3. A broad TL emission, peaking at 440 nm, is observed near 94 K when... more
    Thermoluminescence (TL), optical absorption, and electron paramagnetic resonance (EPR) have been used to characterize point defects in Mg-doped stoichiometric LiNbO3. A broad TL emission, peaking at 440 nm, is observed near 94 K when these crystals are irradiated at 77 K and then rapidly warmed. X rays and below-band-gap lasers (325 and 355 nm) are equally effective in producing the
    Emerging concerns regarding the toxicity of inhaled wood dust support the need for techniques to quantitate wood content of mixed industrial dusts. The diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) analysis... more
    Emerging concerns regarding the toxicity of inhaled wood dust support the need for techniques to quantitate wood content of mixed industrial dusts. The diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) analysis technique was applied to the determination of wood content of 181 inhalable dust samples (geometric mean concentration: 0.895 mg/m(3); geometric standard deviation: 2.73) collected from six wood product industry factories using 25mm glass fibre filters with the Button aerosol sampler. Prior to direct DRIFTS analysis the filter samples were treated with ethyl acetate and re-deposited uniformly. Standards ranging from 125 μg to 4000 μg were prepared for red oak, southern yellow pine, and red cedar and used for quantitation of samples depending upon the wood materials present at a given factory. The oak standards spectra were quantitated by linear regression of response in Kubelka-Munk units at 1736 cm(-1), whereas the pine standards and the cedar standards spectra were quantitated by polynomial regression of response in log 1/R units at 1734 cm(-1), with the selected wavenumbers corresponding to stretching vibration of free C=O from cellulose and hemicelluloses. For one factory which used both soft- and hardwoods, a separate polynomial standard curve was created by proportionally combining the oak and pine standards polynomial regression equations based on response (log 1/R) at 1734 cm(-1). The analytical limits of detection were approximately 52 μg of oak, 20 μg of pine, 30 μg of cedar, and 16 μg of mixed oak and pine for the factory with mixed woods. Overall, the average of dry wood dust percentage of inhalable dust was approximately 56% and the average dry wood dust weight was 0.572mg for the Button samples. Across factories, there were statistically significant differences (p<0.001) for the percentage of dry wood dust in inhalable dust with factory averages ranging from 33.5 to 97.6%.