Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Skip to main content

    W. Mahoney

    The antigen-dependent stabilization of an anti-hen egg lysozyme (HEL) antibody HyHEL-10 variable region was monitored with fluorescence resonance energy transfer (FRET) between fluorolabeled heavy chain (VH) and light chain (VL)... more
    The antigen-dependent stabilization of an anti-hen egg lysozyme (HEL) antibody HyHEL-10 variable region was monitored with fluorescence resonance energy transfer (FRET) between fluorolabeled heavy chain (VH) and light chain (VL) fragments. The VH and VL fragments labeled with succinimide esters of fluorescein and rhodamine-X, respectively, were mixed in a cooled cuvette, and the change in fluorescence spectra upon antigen addition was monitored. When excited at 490 nm, significant decrease in the fluorescence at 520 nm and its increase at 605 nm were observed when an increasing amount of HEL was added to the mixture in the concentration range of 1-100 micrograms/mL. The assay, named open sandwich fluoroimmunoassay (FIA), is noncompetitive and homogeneous and can be conducted with one clone of antibody. With the use of appropriate antibodies, it is thought to be a quick and inexpensive alternative to the conventional laborious and/or expensive immunoassays.
    Abstract — Unstructured open source information, especially the social, political, economic and cultural events described within web-based text/news articles, often contain possible motives for cyber security and trust issues. Automated... more
    Abstract — Unstructured open source information, especially the social, political, economic and cultural events described within web-based text/news articles, often contain possible motives for cyber security and trust issues. Automated processing of numerous open source ...
    Overall five major areas of technology are recommended for development in order to meet the science requirements of the Astrotech 21 mission set. These are: detectors for high resolution gamma ray spectroscopy, cryogenic detectors for... more
    Overall five major areas of technology are recommended for development in order to meet the science requirements of the Astrotech 21 mission set. These are: detectors for high resolution gamma ray spectroscopy, cryogenic detectors for improved x ray spectral and spatial resolution, advanced x ray charge coupled devices (CCDs) for higher energy resolution and larger format, extension to higher energies, liquid and solid position sensitive detectors for improving stopping power in the energy range 5 to 500 keV and 0.2 to 2 MeV. Development plans designed to achieve the desired capabilities on the time scales required by the technology freeze dates have been recommended in each of these areas.
    We report a strategy for generating efficient signal transduction with unnatural heterologous receptor combinations. As previously described [Ueda, H., Kawahara, M. et al. (2000) J. Immunol. Methods 241, 159-170], chimeric receptors... more
    We report a strategy for generating efficient signal transduction with unnatural heterologous receptor combinations. As previously described [Ueda, H., Kawahara, M. et al. (2000) J. Immunol. Methods 241, 159-170], chimeric receptors composed of the V(H)/V(L) domains of anti-hen egg lysozyme antibody HyHEL-10 and N-terminally truncated erythropoietin receptor (EpoR) can be activated by lysozyme. When the cytoplasmic domains of these receptors were substituted with one derived from gp130, IL-3 dependent Ba/F3 cells expressing both V(H)-gp130 and V(L)-gp130 grew dose-dependently when given lysozyme without IL-3. However, cells expressing the heterologous pair of V(H)-gp130 and V(L)-EpoR also showed more efficient and stricter lysozyme-dependent proliferation in the absence of IL-3, indicating this combination is as an efficient and strict signal transducer as wild-type EpoR. The immunoprecipitation data indicated the existence of a preformed V(H)-gp130 and V(L)-EpoR heterodimer in the absence of lysozyme, suggesting the crucial role of a receptor conformational change in signal triggering as well as wild-type EpoR and gp130. Phosphorylation of JAK2, STAT3, and STAT5 was observed upon the addition of lysozyme, suggesting the activation of both EpoR- and gp130-derived signals.
    Although autism spectrum disorders (ASDs) have a substantial genetic basis, most of the known genetic risk has been traced to rare variants, principally copy number variants (CNVs). To identify common risk variation, the Autism Genome... more
    Although autism spectrum disorders (ASDs) have a substantial genetic basis, most of the known genetic risk has been traced to rare variants, principally copy number variants (CNVs). To identify common risk variation, the Autism Genome Project (AGP) Consortium genotyped 1558 rigorously defined ASD families for 1 million single-nucleotide polymorphisms (SNPs) and analyzed these SNP genotypes for association with ASD. In one of four primary association analyses, the association signal for marker rs4141463, located within MACROD2, crossed the genome-wide association significance threshold of P…
    The effects of radiation damage from proton bombardment of the four HEAO C-1 high purity germanium detectors have been measured and compared to predictions. Because of the presence of numerous gamma-ray lines in the detector background... more
    The effects of radiation damage from proton bombardment of the four HEAO C-1 high purity germanium detectors have been measured and compared to predictions. Because of the presence of numerous gamma-ray lines in the detector background spectra and because of the relatively long exposure time of the HEAO 3 satellite to cosmic-ray and trapped protons, it has been possible to measure both the energy and time dependence of radiation damage. After 100 d in orbit, each of the four detectors has been exposed to approximately 3 x 10 to the 7th protons/sq cm, and the average energy resolution at 1460 keV had degraded from 3.2 keV fwhm to 8.6 keV fwhm. The lines were all broadened to the low energy side although the line profile was different for each of the four detectors. The damage-related contribution to the degradation in energy resolution was found to be linear in energy and proton influence.