Dehumidifier Calculation 10
Dehumidifier Calculation 10
5 2540 148 21 2 2 4879 5080 3152 13111 656 13767 14 4 50 60 321 9857 23624 4497 3000 20.2 6.33 398 FVB 1000 7/1/2004 GR/LB 162 14 148 % RH 10
AMBIENT DESIGN
Volume F1 F2 F3 F4 F5 Grain Differnce Door area Opening / Hr Occupancy Permeation Load People Load Door Load Sub Total Safety 5 % Total Room Load Design Grains Total Grains Dry air leaving at design temperature & grains Make up / Fresh air Grains at Coil Leaving grains CFM Required Make up air required Total Grains Design Load Fresh air load Dehumoidifier inlet Grain Dehumidifier leaving grains for deh inlet grains Dehumidifier Size MODEL SELECTED
ANNEXURE I BILL OF QUANTITIES Sr.No. Description Unit Double skin air handling units complete with the following sections working in 1 conjuction with the air cooled condensing unit Mixing Chamber Prefilter section with 10 micron pre filters Cooling coil section with 4 rows deep cooling coil Fan section with fan FA cooling coil of 10 rows deep 1.2 1000 CFM / 2" S.P / 2 H.P No. 4.0 SHEET METAL WORKS 4.2.1 24 G ( 0.63 mm Thick ) sq.ft Supply air duct with 50 mm thick expanded polystyrene finished with polyster film 4.3 sq.ft 4.4 4.9 4.10 Return air duct with 25 mm thick expanded polystyrene finished with polyster film Volume control damper sq.ft sq.ft
Qty.
Rate
Amount
Terminally mounted supplu / return air box in minimum 16 G thick M.S. powder coated complete with two way extruded aluminum grill & complete with gear operated volume control dampers. 24" x 24" Nos.
3065
6130
18
19 20
MICROVEE FILTERS designed to remove particles down to 5 Microns in M.S. construction with an efficiency of 99.9% on ASHRAE STD. 52-76 and 90% on BS 2831 Test Dust No. 2 (Junior Filter) in M.S.construction. The filter shall have 3 stage NWP sandwitch 24" X 24" X 6" MICROVEE FILTERS designed to remove particles down to 3 Microns in M.S construction with an efficiency of 99.9% on ASHRAE STD. 52-76 and 90% on BS 2831 Test Dust No. 2 (Junior Filter) in M.S.construction. The filter shall have 3 stage NWP sandwitch 24" X 24" X 6" Plenum for mounting above filters in GI construction Blue star make air cooled condensing unit comprising of reciprocating compressor and air cooled condenser complete 2 TR 5.5 TR Referigerant piping 3 TR 5.5 TR Controls for condensing units 2 TR 5.5 TR First charge of R 22 Gas Stand for mounting condensing units Electrcal panel 3c x 4sq. Mm al 7c x 1.5 sq.mm Al 8 G G.I Earthing
Nos.
1250
1250
Nos. sq.ft
1 80
1400 55
1400 4400
No. No. rft rft Nos. Nos. Kg Nos. No rft rft rft
1 1 0 30 30 0 1 1 15 2 1 100 50 300
4000 6000 5700 3000 25000 2400 1750 900 251780 PFFI 3% 25000 Travelling 30000 Erection 30000 336780 M.U 40% 250000 586780 WCT 4% 23471 610251 Neg15 % 91538 701789