APM120

CONTENTS
PAGE
APPLICATIONS 1.1
SPECIAL FUNCTIONS 3.1
CONNECTOR LOCATIONS 2.1
Version 1.0 08/03
APPLICATIONS MANUAL
FIAT/ALFA/LANCIA IMMOBILISER SYSTEM
ALFA






FIAT


1.1
APPLICATIONS
VEHICLE YEAR SYS KEY
PROG
PLIP
PROG
KEY
INFO
LIVE
DATA
FAULT
CODES
CABLE
147 ALL CAN Y Y Y Y ADC110-B
156 98MY ON ISO Y Y Y Y Y ADC110-B
166 98MY ON ISO Y Y Y Y Y ADC110-B
VEHICLE YEAR SYS KEY
PROG
PLIP
PROG
PLIP
INFO
LIVE
DATA
FAULT
CODES
CABLE
SCUDO ALL ISO Y Y Y Y ADC110-B
DOBLO ALL ISO Y Y Y Y ADC110-B
DUCATO 98MY ON ISO Y Y Y Y ADC110-B
MULTIPLA 98MY ON ISO Y Y Y Y ADC110-B
PALIO ALL ISO Y Y Y Y ADC110-B
PUNTO NEW CAN Y Y Y Y ADC110-B
SEICENTO 99MY ON ISO Y Y Y Y ADC110-B
STILO ALL CAN Y Y Y Y ADC110-B
ULYSSE ALL ISO Y Y Y Y ADC110-B

















1.2
APPLICATIONS
LANCIA
VEHICLE YEAR SYS KEY
PROG
PLIP
PROG
ACTUA-
TORS
FAULT
CODES
CABLE
LYBRA ALL ISO Y Y Y ADC110-B
PHEDERA ALL ISO Y Y Y ADC110-B
THESIS 98MY CAN Y Y Y Y ADC110-B
Z ALL ISO Y Y Y ADC110-B




2.1
CONNECTOR LOCATIONS
GTV
147
ALFA




2.2
CONNECTOR LOCATIONS
PUNTO
SCUDO
FIAT




2.3
CONNECTOR LOCATIONS
SEICENTO
STILO
FIAT




2.4
CONNECTOR LOCATIONS
GTV
FIAT
3.1
SPECIAL FUNCTIONS

CAN SYSTEMS
:
















From the main diagnostic menu select
SPECIAL FUNCTIONS.










Select PROGRAM KEYS from the special
functions menu.









NOTE : ANY KEYS NOT
PROGRAMMED AT THIS POINT WILL
BE DELETED PERMANENTLY. EVEN
EXISTING KEYS !









To enter the 5 digit security code use the
numerical keypad keys.




ECU IDENTIFICATION
FAULT CODES
SPECIAL FUNCTIONS
DIAGNOSTIC MENU
PROGRAM KEYS
KEY INFORMATION
REMOTE INFORMATION
ACTUATORS

SPECIAL FUNCTIONS
PRESS ENTER KEY


SECURITY CODE

_ _ _ _ _

KEYS NOT AVAILABLE WILL
BE DELETED!


PROGRAMMING KEYS
PRESS ENTER KEY
3.2
SPECIAL FUNCTIONS

























The number of existing keys pro-
grammed is displayed.

To exit press the BACK key on the
AD100. Otherwise press ENTER to
continue.








REMOVE KEY from ignition then IN-
SERT next key.

Switch IGNITION ON.



Press ENTER to continue.








The number of keys now programmed
in is displayed.

To continue and program in RE-
MOTES press ENTER. Otherwise
press BACK to exit.







KEYS PROGRAMMED: 1

BACK TO EXIT
ENTER TO PROGRAMME
NEXT KEY
PROGRAMMING KEYS
REMOVE KEY

INSERT NEXT KEY

SWITCH IGNITION ON
PROGRAMMING KEYS
PRESS ENTER KEY
XX KEYS PROGRAMMED

BACK TO EXIT

ENTER TO PROGRAM
REMOTES
PROGRAMMING KEYS
3.3
SPECIAL FUNCTIONS

CAN SYSTEMS

























To program in remotes follow the on
screen instructions from the PROGRAM-
MING KEYS screen.

The programming remotes screen is dis-
played. It indicates the number of remotes
stored.







To program in another remote press EN-
TER otherwise press BACK to exit.


The number of remotes stored has in-
creased.












When exiting, this screen is shown indi-
cating the total number of remotes pro-
grammed in.






PRESS REMOTE

REMOTES STORED : 00

BACK TO EXIT

ENTER TO PROGRAM
NEXT REMOTE
PROGRAMMING REMOTES


REMOTES STORED : 2


PROGRAMMING REMOTES
PRESS ENTER KEY
PRESS REMOTE

REMOTES STORED : 01

BACK TO EXIT

ENTER TO PROGRAM
NEXT REMOTE
PROGRAMMING REMOTES
3.4
SPECIAL FUNCTIONS

CAN SYSTEMS





















To view Key information follow the menu
selection procedure


Diagnostics menu>Special functions>
Key Information













To view Key information follow the menu
selection procedure

Diagnostics menu>Special functions>
Remote Information

KEYS STORED: 2
LOST KEYS: 1
LOST KEY ID: 1232
IGNITION: ON/OFF

KEY INFORMATION
BACK TO EXIT
REMOTES STORED: 2
LOST REMOTES: 1
LOST REMOTE ID: 123456
REMOTE DR LOCK: ON
REMOTE DR UNLOCK: ON
REMOTE BT UNLOCK: OFF
REMOTE INFORMATION
BACK TO EXIT
3.5
SPECIAL FUNCTIONS

ISO SYSTEMS



















From the main diagnostic menu se-
lect SPECIAL FUNCTIONS.












Select PROGRAM KEYS from the spe-
cial functions menu.










To enter the 5 digit security code use
the following procedure :-

Press to elect Number & Letter

Press To Erase the previous selec-
tion

Press To ENTER selection.

Press To Finish PIN selection.

ECU IDENTIFICATION
FAULT CODES
SPECIAL FUNCTIONS
DIAGNOSTIC MENU
PROGRAM KEYS
LIVE DATA
ACTUATORS
KEY INFORMATION

SPECIAL FUNCTIONS
PRESS ENTER KEY


SECURITY CODE

_ _ _ _ _

SECURITY CODE

1 2 3 4 5

IS THIS CORRECT
OK = ENTER CLEAR =BACK
3.6
SPECIAL FUNCTIONS
























OR





NOTE : ANY KEYS NOT
PROGRAMMED AT THIS POINT
WILL BE DELETED PERMA-
NENTLY. EVEN EXISTING KEYS !







Depending on the status of the key in-
serted the following messages will ap-
pear:



Press ENTER to continue.














Press BACK to EXIT otherwise ENTER
to continue.

KEYS NOT AVAILABLE WILL
BE DELETED!


PROGRAMMING KEYS
PRESS ENTER KEY

KEY ERROR


PROGRAMMING KEYS
PRESS ENTER KEY

KEYS PROGRAMMED: 1

BACK TO EXIT

ENTER TO PROGRAM
NEXT KEY

PROGRAMMING KEYS
3.7
SPECIAL FUNCTIONS

























If ENTER is pressed on wither of the
previous screens then this screen will be
displayed indicating the key program-
ming procedure.











To enter the 5 digit security code use
the following procedure :-

Press to elect Number & Letter

Press To Erase the previous selec-
tion

Press To ENTER selection.

Press To Finish PIN selection.
REMOVE KEY

INSERT NEXT KEY
LEAVING IN STOP POSITION

PROGRAMMING KEYS
PRESS ENTER KEY


SECURITY CODE

_ _ _ _ _

SECURITY CODE

1 2 3 4 5

IS THIS CORRECT
OK = ENTER CLEAR =BACK
3.8
SPECIAL FUNCTIONS























The key information screen is displayed.
Press ENTER to continue.








KEYS PROGRAMMED: 2
KEY 1: 12345678
KEY 2: 12345678
KEY 3: 12345678
KEY 4: 12345678

KEY INFORMATION
PRESS ENTER KEY