Smart Powered Process Signal Isolator/Conditioner: SEM1600VI
Smart Powered Process Signal Isolator/Conditioner: SEM1600VI
Smart Powered Process Signal Isolator/Conditioner: SEM1600VI
SEM1600VI
(-50 to 50) V or (-50 to 50) mA INPUT
INPUT
POWER
OUTPUT
INTRODUCTION
The SEM1600VI is a smart powered isolator/conditioner that accepts any voltage signal between (-50 and 50) V dc or any current
signal between (-50 and 50) mA. The output stage offers either voltage, bipolar voltage or current re-transmission signals. The
retransmission signal can be ranged to a scale anywhere within the input process range. A transmitter power supply is provided on
both input and output meaning the products can accept sink or source applications.
There are a number of free software tools available including 22 segment user linearisation / profiling, maths functions and input
signal damping. These enable you to configure the product exactly to your requirements.
For ease of use, a high efficiency switch mode power supply is fitted as standard and does not require any adjustment between ac or
dc applications. Operating voltages are (10 to 48) V dc and (10 to 32) V ac
Our USB interface is fitted for quick and easy configuration. Just connect a standard USB cable between the SEM1600VI and your PC.
Using our free configuration software, your PC will automatically upload the existing configuration data and guide you through any
changes you wish to make. To further help save time, the SEM1600VI does not need to be wired to a power supply during the
configuration process, it is powered via the USB interface from your PC.
VOLTAGE INPUT
Range
Impedance
Drift
OUTPUT CURRENT
Current Source
Current Sink
Accuracy
Tx
Voltage
mA
Output Current
OUTPUT VOLTAGE
Range
Current Drive
SUPPLY
Range
Power
(10 to 48) VDC, (10 to 32) VAC Protected by internal 500mA resettable fuse.
< 1 W Full Power
GENERAL
Response time
Isolation
Indication
Start up 5 seconds, Update 300 mS, Response 400 mS, Warm up 2 minutes.
Supply to input to output 500 V dc.
LED, Green when output (-0.1 to 100.1) %, else red
USER INTERFACE
Type
Baud rate
Equipment
USB 2.0
19,200 baud
PC running windows XP or later, USB cable.
ENVIRONMENT
Operating Ambient
Storage Ambient
Configuration Ambient
Installation Enclosure
APPROVALS
CE
BS EN 61326
MECHANICAL
Style
Terminals
DIN 43880, Colour grey, material Polyimide 6.6, weight < 70 grams
2.5 mm Maximum
Source
Sink
3
(10 to 30)
V dc
6
1
2
10 11 12
90 mm
17.5 mm
Order code:
Status Instruments Ltd
Green Lane Business Park
Green Lane, Tewkesbury
Gloucestershire, UK
GL20 8DE
SEM1600VI
Tel: +44 (0)1684 296818
Fax: +44 (0)1684 293746
Email: sales@status.co.uk
Website: www.status.co.uk
D2535-01-04 CN5043 SEM1600VI Data Sheet