1. SPECIFICATION
Sensing Input
Voltage
Frequency
Power Input
Voltage
Resistance
Output
Voltage
Current
Voltage Regulation
< 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Dimensions
156mm L * 106mm W * 43mm H
Thermal Drift
0.03% per C change in AVR ambient
Weight
450g 2%
ATTENTION
1. AVR can be mounted directly on the engine,
genset, switchgear, control panel, or any position
that will not affects operation. For dimension
reference, please see Figure 1.
High Temperature
Figure 1
Outline Drawing
UNIT : mm
______________________________________________________________________________________
2
EA16
2. CONNECTION TERMINAL
1. P1, P2 Power Input Terminals from 60 to
300VAC 50/60Hz -16A rated.
2. F+, FMaximum Output current 16A.
3. VS1, VS2Voltage sensing input terminals, Volts
selected using DIP SW1 for 220V or 440V.
4. K, LLoad Current Compensation (Droop), CT
secondary current input selected by using DIP
SW 1A or 5A (If droop not used leave terminals
open).
5. VR1, VR2External Voltage trim use, 2K Ohms 1
watt trimmer for 5% voltage adjustment. Keep
terminals shorted when not in use.
6. A1, A2Analogue Voltage Input terminals used
for Power Factor correction from a external PLCThe PLC controls provides a DC voltage signal to
adjust the generator voltage. Max. Adjustment
range is 5VDC. Keep terminals open when not
used.
7. DIP Switch
SW1OFF 220VAC (170 to 260VAC)
ON 440VAC (340 to 510VAC)
SW2OFF CT Secondary Input 1A
ON CT Secondary Input 5A
SW3OFF Generator Frequency 60Hz,
52 ~ 61Hz Adjustment
ON Generator Frequency 50Hz,
42 ~ 51Hz Adjustment
SW4OFF Over excitation protection enabled
ON Over excitation protection disabled
8. LED Indicator
U/FUnder Frequency Indicator
O/EOver Excitation Indicator
______________________________________________________________________________________
EA16
4. NOTICE OF USE
1. Installation Notice(Refer to Figure 2 and 4).
Only, a trained professional can Installation,
calibrate and inspections this AVR.
Install this AVR inside the generator enclosure
away from moisture, corrosion and from any easy
to reach area.
2. Generator Operation Notice
During operation, the temperature on the surface
of the AVR can reach higher the 60 C / 140F.
DANGER When the AVR is working never
touch or ground the heat sink on the AVR. The
AVR heat sink is an electrically live terminal.
A warning sticker is in place on top of the heat
sink.
5. FIELD FLASHING
When operating this AVR for the first time, the
polarity of the residual magnetism may be reversed
or too weak to achieve the necessary build-up on
the regulator. If reversing the field connections does
not induce build-up, and the residual voltage is less
than 5 VAC, shut down the Prime-mover and
proceed with the following steps
1. Stop the generator and disconnect the field wires
(F+ and F), apply a DC Voltage using a
batteries positive terminal to F+ and the negative
terminal to F, using a current-limiting resistor of
3~5 ohms 20 watt.
2. Allow approximately 3 seconds before removing
the battery.
______________________________________________________________________________________
4
EA16
R
R
S
GEN
GEN
T
T
Field
Field
P1 P2 F+ F-
VS1 VS2
P1 P2 F+ F-
VS1 VS2
EA16A
EA16A
VR1 VR2
A1
VR1 VR2
A2
EXT. VR
A1
A2
EXT. VR
Figure 3
220V Connection
GEN
T
GEN
T
Field
P1 P2 F+ F-
VS1 VS2
Field
EA16A
VR1 VR2
A1
P1 P2 F+ F-
A2
VS1 VS2
EA16A
VR1 VR2
EXT. VR
A1
A2
EXT. VR
Figure 2
Paralleling Connection
Figure 4
Field
R
S
GEN
T
N
Aux.
Winding
60~300v
P1 P2 F+ F-
VS1 VS2
EA16
VR1 VR2
A1
A2
EXT. VR
Figure 5
Auxiliary Winding
______________________________________________________________________________________
EA16
6. TROUBLE SHOOTING
SYMPTOM
Voltage does not
build up
CAUSE
CORRECTION
Burnt fuse
Use only original supplied spare protection fuse for fuse replacement.
Please accept our sincere apology if any modification in performance, specification or appearance is
made without prior notice.