Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

WF5 Config Options

Download as pdf or txt
Download as pdf or txt
You are on page 1of 163

Table of Contents

1 137

Pro/ENGINEER Wildfire 5.0 Configuration Options

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Parametric Technology Corporation

iii

Pro/ENGINEER Wildfire 5.0 Configuration Options

Pro/ENGINEER Wildfire 5.0 Configuration Options


Description Docked - Displays the accessory window embedded in the active window. Undocked - Displays the accessory window as a stand alone window. Enter an accuracy value to override the default lower limit.The minimum value for relative accuracy is 1E-06. For ACIS interface allows to export object, feature and entity level parameters. Allows selection of model units for ACIS export. Allows the user to choose ACIS export version. Sets the Adobe Acrobat Reader command path. This value will be used to launch the reader after exporting a PDF document. Prepends the option value on the java environment variable, CLASSPATH, used to find classes in J-Link programs. To specify multiple search paths in the same line, delimit them using ':' on UNIX, and ';' on Windows NT. Setting this option to yes will check off the Favor Current Layer option, which allows lower level components to be added to top level layers. Yes - System includes welds when calculating mass properties and approximates light weight weld mass properties. No - System excludes welds when calculating mass properties. 1 yes, no no 5, 4 yes, no in, ft, m, mm, cm, micron, default 0.0001 undocked, docked docked Values Default value

Name

Category

accessory_window_display

Without category

accuracy_lower_bound

Environment

acis_export_params

Data Exchange

no default 5

acis_export_units

Data Exchange

acis_out_version

Without category

acrobat_reader

Printing & Plotting

add_java_class_path

Application Programming Interfaces

add_lower_level_comps_to_layer

Layers

add_weld_mp

Weld

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Control the appearance of the intersection tool and scope of available functionalities. Use advanced options by default for Surface Edit in Style. Sets the AE detail dependency for AE's that are locally propagated. If set to independent, the AE's parameter call outs will update to other propagated AEs parameters. Specifies the aec drawing annotation attribute/parameter specification file name. Specifies the aec object type file name. Specifies the file name of the user defined piping parameter codes. Toggle display of Copy References column in Annotation Feature definition dialog Align NEWLY CREATED bundles where they meet or branch out Allow the creation of pre-Pro/E 2000i geometry features including ear, neck, lip, slot, flange, shaft, local push, radius dome and section dome. Display a confirmation window when exiting Pro/ENGINEER. This enables you to use the mouse to confirm/cancel exiting Pro/ENGINEER. Make the Delete Many command available in drawing mode. The Delete Many command is not supported by undo but can improve performance when deleting a significant number of items. 2 no, yes no dependent, independent yes, no no dependent yes, no no

Category

Description

Values

Default value

advanced_intersection

Assembly

advanced_style_surface_edit

Without category

ae_propagate_detail_dependency

User Interface

aec_dwg_anno_attrpar_spec_file

Piping

aec_dwg_anno_attrpar am_spec.ptd aec_object_type.ptd

aec_object_type_file

Piping

aec_parameter_file

Without category

af_copy_references_flag

User Interface

align_cable_bundles

Electromechanical

yes, no yes, no

yes no

allow_anatomic_features

Features

allow_confirm_window

User Interface

yes, no

yes

allow_delete_many_in_drawings

Without category

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Allows checkout failure for floating modules. Enables the usage of advanced copy/paste functionality tocontrol degree of dependency on the pasted object. Allow to retrieve a harness mfg assembly directly. Yes - Move and Move Attach commands in drawing mode act together. No - Move and Move Attach commands in drawing mode do not act together. Disallow the movement of drawing views with the mouse. Sets what type of children packaged components can have. ALL - Features and components can be a children of packaged component. FEAT - Only features can be children of packaged components. NONE - Packaged components cannot have children. Yes - Enables Pro/COMPOSITE to create a cross-section of composite plys. Yes - Displays the ReIntersect command in the ASSY FEAT menu. No - Displays the message "Reference scope changes are prohibited by the configuration file settings" when the Ref Scope user interface is changed. yes, no yes, no yes, no all, feat, none yes, no yes, no yes, no no yes yes, no yes no, yes no

Category

Description

Values

Default value

allow_float_opt_checkout

System

allow_fully_dependent_copy

Features

allow_harn_mfg_assy_retrieval

Electromechanical

allow_move_attach_in_dtl_move

Drawing

allow_move_view_with_move

Drawing

no all

allow_package_children

Assembly

allow_ply_cross_section

Miscellaneous

yes no yes

allow_redo_intersections

Assembly

allow_ref_scope_change

Without category

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Allows you to create drawing references to geometry representations (includes dimensions, notes, and leaders). These references may become invalid if the referenced geometry changes resulting in geometry representations not updating in drawings. Yes - Enables RFS/Default gtols to be created even when not permitted by ANSI standard. Allows the option to save a copy of the active model as a family table instance. Allow calculation before relations. Yes - Allows a solid to be displayed with hidden lines while in perspective. Defines the Cosmetic Thread user interface. Yes - Creates a Cosmetic Thread as a UDF. No - Creates a Cosmetic Thread as a Cosmetic Thread feature. Allow updating part Simplified Rep data in session automatically when switching from one Simp Rep to another.Yes - Allow updating part simplified rep data. No - Do not update part simplified rep data. Prompt - Prompt the user if the current simplified rep should be updated. Determines if the workpiece is allowed for Silhouette Mach Window creation. NO only reference part is allowed; YES - both workpiece and reference part are allowed; AUTO - only workpiece is allowed. yes, no no, yes yes, no yes, no no, yes no yes, no no

Category

Description

Values

Default value

allow_refs_to_geom_reps_in_drws

Drawing

allow_rfs_default_gtols_always

Dimensions & Tolerances

allow_save_as_instance

Assembly

no no yes no

allow_shrink_dim_before

Casting & Mold Design

allow_solid_perspective_hlr

Model Display

allow_udf_style_cosm_threads

Features

allow_update_part_simp_rep_data

Assembly

yes, no, prompt

yes

allow_workpiece_silhouette

Without category

yes, no, auto

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines whether regeneration of analysis features creates/updates tmp files Yes - If the display is in the default pan/zoom setting (View>Pan/Zoom>Reset), the system checks whether an angular dimension is visible on the screen. If it is not visible, then the system moves the dimension to a visible location. Sets the display of angular dimensions to decimal degrees (ang_deg), degrees and decimal minutes (ang_min) or degrees, minutes and decimal seconds (ang_sec). Modify grid space in angular units for handle movement. An alternative format for setting default angular tolerance dimensions. The value sets the number of decimal places, and the tolerance is the actual tolerance value. For integer dimensions, the value is zero, and the tolerance is an integer. Sets the default tolerance for angular dimensions. Each option sets a tolerance for a specific decimal place. The value is the place of the last decimal. Sets the default tolerance for angular dimensions. Each option sets a tolerance for a specific decimal place. The value is the place of the last decimal. Sets the default tolerance for angular dimensions. Each option sets a tolerance for a specific decimal place. The value is the place of the last decimal. 5 ang_deg, ang_min, ang_sec ang_deg yes, no no yes, no yes

Category

Description

Values

Default value

analysis_crt_tmp_file_on_regen

File Storage & Retrieval

ang_dim_in_screen

Dimensions & Tolerances

ang_units

Environment

angle_grid_interval

Features

1 0

angular_tol

Dimensions & Tolerances

angular_tol_0.0

Dimensions & Tolerances

angular_tol_0.00

Dimensions & Tolerances

50

angular_tol_0.000

Dimensions & Tolerances

500

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default tolerance for angular dimensions. Each option sets a tolerance for a specific decimal place. The value is the place of the last decimal. Sets the default tolerance for angular dimensions. Each option sets a tolerance for a specific decimal place. The value is the place of the last decimal. Sets the default tolerance for angular dimensions. Each option sets a tolerance for a specific decimal place. The value is the place of the last decimal. Animate the transition between explode states and mold opening steps. Sets the upper limit for a radius in a CIRCLE statement of NCL file. The value must be positive. If not, 10*part_size is used. Show the both required and optional owners to be designated. Assemble parent connectors on locations referencing a subconnector. Sets state of ATB 'Auto Check Status On Activate' toggle. Sets state of ATB 'Auto Check Status On Retrieve' toggle. Sets state of ATB 'Auto Check Status On Update' toggle. Allows to identify CADDS files in the file open browser. yes, no yes, no on, off on, off on, off yes, no yes, no 50000 5000

Category

Description

Values

Default value

angular_tol_0.0000

Dimensions & Tolerances

angular_tol_0.00000

Dimensions & Tolerances

angular_tol_0.000000

Dimensions & Tolerances

500000

animate_explode_states

Model Display

no -1

arc_radius_limit

Without category

ask_designate_owners

Without category

yes yes off on off no

assemble_parent_connector

Electromechanical

atb_auto_check_on_activate

Data Exchange

atb_auto_check_on_retrieve

Data Exchange

atb_auto_check_on_update

Data Exchange

atb_ident_cadds_files

Data Exchange

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Allows to update a Pro/DESKTOP assembly based on assembly component ids, if set to YES. Otherwise, the update will be based on component names. Extends search path for ATB Update and ATB Check Status commands. Sets state of ATB 'Show Log' toggle. Setup menu manager attachment to the main Pro/E window. Define path and file name of external file used to define parameters that are automatically created in all Annotation Elements. Yes - Enables automatic assembly. No Disables automatic assembly. Yes - The drawing setup option associative_dimensioning is also set to Yes. The system tries to associate imported IGES dimensions (not yet associative) with corresponding imported geometry. Yes - Create Component Reference Backup, No - Do not Create Component Reference Backup. Control whether auto constraint should create offsets. Yes - Auto constraint alw ays creates offsets. No - Auto constraint snaps align or mate if surfaces are wi thin tolerance. Never - Auto constraint never create offsets. no, yes yes, no yes no yes, no on, off on no yes, no yes

Category

Description

Values

Default value

atb_prod_asm_upd_by_comp_ids

Data Exchange

atb_search_path

Without category

atb_show_log

Data Exchange

attach_menumanager

Without category

auto_ae_param_file

User Interface

auto_assembly_with_layouts

Assembly

auto_associate_dimensions

Data Exchange

auto_backup_new_placemnt_refs

Assembly

yes, no

no

auto_constr_always_use_offset

Assembly

yes, no, never

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the auto constraint tolerance for creating offset dimensions. If distance is less than this tolerance multiplied by component size, offset is set as coincident. Default value is 0.5 . Yes - When regenerating a pre-Release 11.0 cabling assembly, the system automatically creates a separate spool feature for every individual wire or cable in the assembly. No - An interface for the cable conversion appears. If the option is "yes" newly created rep would be updated each time on retrieve/regeneration. Control the default setting of the check box in the Propagate annotation dialog box which controls whether to pass all annotations plane references. Yes - causes the automatic, local propagation of AE's after a supported feature has been created. Yes - Automatically repaints the drawing display when changing from one window to another. No - Update to drawing views will only occur when manual updates are made via Repaint or View> Update. When set to yes, AEs parallel to the view will be displayed while creating a new view. When set to yes, traceback.log file will be generated when fatal error occurs. no, yes no, yes no, yes no yes, no yes 0.5

Category

Description

Values

Default value

auto_constr_offset_tolerance

Drawing

auto_convert_cables

Electromechanical

auto_evaluate_simprep_rules

Assembly

auto_include_annot_plane

User Interface

yes

auto_propagate_ae

User Interface

no

auto_regen_views

Drawing

yes, no

yes

auto_show_3d_detail_items

Without category

yes, no

yes

auto_traceback

System

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Automatically load Cabling Logical Reference from an XML file when retrieving the cabling assembly Automatically create an XML Logical Reference when saving a cabling assembly Loads AutobuildZ application. Storage directory for holemaking MUDF's that are used by Pro/NC Auto-drilling functionality Retrieve automatically and load the configuration file for the auto-drilling table. Parameter name included in hole features of a manufacturing reference model.The parameter value identifies the MUDF for holemaking that is automatically applied in Pro/NC to drill these holes. If set to yes, copying a feature group containing an Annotation feature will automatically hide the Annotation Features in the new group. Assembling components with an interface will automatically place the component at the first position satisfying the interface definitions. Determines the maximum number of edge chains that the Auto-Round algorithm will attempt to round in each Auto-Round member Set the wire parameter to use to select a path during autorouting. Enable display of popup menu info in the trail file. 9 yes, no yes, no no autodrilling yes, no no yes, no no yes, no no

Category

Description

Values

Default value

auto_xml_on_retrieve

Electromechanical

auto_xml_on_save

Electromechanical

autobuildz_enabled

Drawing

autodrill_udf_dir

Manufacturing

autodrilling_config_filename

Manufacturing

autodrilling_holestyle_param

Manufacturing

autohide_copied_group_af

Features

autoplace_single_comp

Assembly

no, yes

yes

autoround_max_n_chains_per_feat

Features

20

autoroute_path_param_name

Electromechanical

use_path no Pro/ENGINEER Wildfire 5.0 Configuration Options

auxapp_popup_menu_info

User Interface

Parametric Technology Corporation

Name Yes - Turns on the keyboard bell that rings after each prompt. No - Turns off the keyboard bell. To override this setting use the Environment dialog box on the Tools menu. Works in conjunction with save_bitmap. Determines the size (squared) of the bitmap image that is stored. Blanks specified layers when you begin a Pro/ENGINEER session. The value is the layer ID. Yes - Transparent colors will appear using alpha blending (if supported) when the model is shaded. BMX graph tool Specifies the location of the Graph Tool preference file. yes, no Setup whether the new extract bundle algorithm should be used. Sets the BOM format file to be used for a customized BOM.Specify name and path. Specifies the directories visible in the file browser for quick navigation.Use the full path to avoid problems. Determines whether or not revision number is increased for generic models that regenerate and change during assembly retrieval.Only applies if new_asm_regen_revnums is yes (otherwise, there will be no revision number bumping). 10 yes, no yes yes, no yes no no, yes yes 200 yes, no no

Category

Description

Values

Default value

bell

Environment

bitmap_size

Data Management

blank_layer

Layers

blended_transparency

Model Display

bm_graph_tool

User Interface

default, excel_linked, excel embedded

default

bmgr_pref_file

User Interface

bmx_param_restrictions

Without category

boeing_extract_bundle

Without category

bom_format

Drawing

browser_favorite

File Storage & Retrieval

bump_revnum_on_retr_regen

Assembly

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - The name and menu of any selected menu option displays, in English, in the help text associated with that button. Allows color import for Catia V5 interface. No - Global clearance checking for internal cable portions is excluded. Yes - Global clearance checking for internal cable portions is included. Cables are not hidden behind objects. Define the line width of entities within Pro/ENGINEER to plot drawings with correct line weights that are consistent with a standard. The default Pro/ENGINEER values for these weights are: 2 (light), 3 (medium), 5 (heavy). Allows import of CADDS5 layering. Specifies the CAM-Post load point directory to enable you to directly set-up the post-processors and generate MCD files. Controls whether to enable snapping to missing references while dragging components for placement. Yes Snapping is enabled while dragging. No Snapping is disabled while dragging. Yes - Displays the model as a solid when shaded and clipped. No - Displays the model as surfaces when shaded and clipped. yes, no yes yes, no no, yes yes 0 no, yes no yes, no no yes, no no

Category

Description

Values

Default value

button_name_in_help

User Interface

c5_color_import

Data Exchange

cable_int_portions_for_clr

Electromechanical

cables_with_hlr

Electromechanical

cadam_line_weights

Data Exchange

cadds_import_layer

Data Exchange

yes

campost_dir

Manufacturing

can_snap_to_missing_ref

Assembly

capped_clip

Model Display

no, yes

yes

Parametric Technology Corporation

11

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Append - If the selected CATIA model already exists, the new data is appended to the existing CATIA file. Overwrite - If the selected CATIA model already exists, the newly exported file overwrites the existing one. Modify grid space in centimeter units for handle movement. No - Do not use a defined pen table for formatting of CGM export. Controls the display of chamfer dimension text without affecting the leader. This only affects the text of newly created dimensions. ASME/ANSI is the default. Determines whether to permit different names for different part occurrences, or not in mirror subassembly UI. Yes - updates UDF internal keys upon group's retrieval. No - skips keys update. Yes - Includes all reference part surfaces as check surfaces for profiling and pocketing NC sequences. Enables you to control the size of the tool path arrow for contouring NC sequences. 0 - The arrow does not display. Any other value - The arrow scales accordingly. TOOL or TABLE - defines ROTATE sign direction convention based with respect to either rotation table or cutting tool. Specifies the quality of surface triangulation used to obtain initial guess points for clearance and interference calculations. 12 table, tool yes, no yes, no yes, no asme/ansi, iso/din, jis no, yes 0.1 no asme/ansi append, overwrite append

Category

Description

Values

Default value

catia_out_to_existing_model

Data Exchange

centimeter_grid_interval

Features

cgm_use_pentable

Data Exchange

chamfer_45deg_dim_text

Drawing

check_same_assy_parts

Assembly

yes

check_udf_int_key

Without category

yes no

chk_part_surfs_profpock

Manufacturing

cl_arrow_scale

Manufacturing

cl_rotate_sign_convention

Manufacturing

table

clearance_triangulation

Environment

none, low, medium, high

none

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Display clipping after Visibilities dialog box is closed. Yes - Displays the clock while Pro/ENGINEER is working. Sets the display of the system accuracy when calculating clearances between two parts or surfaces. The default is to not display the accuracy. Defines the file that contains the userdefined tool parameters' list. This config options allows dimensions to be collected on the active layer. Turns the colors on or off. Turning colors off displays the model wireframe in white. Specifies the number of shades in a color ramp. Applicable to multi-color, shaded model displays of simulation / analysis results. System graphics must support 256 colors and color maps that compress. Specifies minimum allowable deviation between user-defined colors. Colors having RGB values within tolerance of existing colors cannot be created. Decreasing this setting allows more colors that are very similar in RGB value to be defined. All_windows - Wireframe colors display in the main window and all auxiliary windows. One_window - Colors display only in the main window. Auxiliary windows display wireframe in the default color. Enable / Disable combined views customization. 13 all_windows, one_window no, yes yes, no yes yes -1 yes, no no yes, no no no, yes yes

Category

Description

Values

Default value

clip_always

Model Display

clock

Environment

clr_print_plus_minus

Environment

cmm_custom_tool_param_file

Manufacturing

collect_dims_in_active_layer

Without category

color

Colors

color_ramp_size

Colors

color_resolution

Colors

0.1

color_windows

Colors

all_windows

combined_views_customization

Without category

yes, no

yes

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the angle epsilon such that if the desired surfaces are equal or greater than the epsilon (in degrees), than an angle offset constraint will be created. Sets the initial assembly placement behavior when assembling a new component. Default - Default initial position.Package - Define initial position using the Move option.Constraint_in_Window - Use secondary window. Move_then_Place Define initial position using the Move option and thendefine placement constraints. Settings for assembling component with interface(s). Sets the default interface placement type. Interface to geometry - place the component using component interfaces and assembly geometry. Interface to Interface - place the component using assembly and component interfaces. No - Assembly is not rolled back when the user redefines a component. Specify the angle tolerance for snapping while freeform dragging components. Default value is 30.0 degrees. Specify the distance tolerance for snapping while freeform dragging components.Default value is 0.1 (relative to size of component being assembled). default_multi, default_single, from_list, none interface_to_interface, interface_to_geom default, package, constrain_in_window, move_then_place 10

Category

Description

Values

Default value

comp_angle_offset_eps

Assembly

comp_assemble_start

Assembly

comp_assemble_with_interface

Without category

default_multi interface_to_interface

comp_interface_placement

Without category

comp_rollback_on_redef

Assembly

yes, no

yes 30

comp_snap_angle_tolerance

Without category

comp_snap_dist_tolerance

Without category

0.1

Parametric Technology Corporation

14

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Used with the export option iges_out_mil_d_28000. To support MIL-D28000, your company name is required input and the system prompts you every time you export through IGES unless you set the company name in your configuration file. You can compress object files to store them. Compressed files are generally somewhat smaller than non-compressed files (but may be larger in some cases). Compressed files are slower to read and write. Yes - Stores object files in compressed format. Display the presenter's mouse motions when observing a shared Pro/ENGINEER session. Sets the maximum allowable gap between weld contact surfaces. Convert to Wildfire3 replace functionality. YES - Imports each component of AutoCAD dimension separately. NO Imports AutoCAD dimensions as dimensions in Pro/ENGINEER. AS_SYMBOL - Imports AutoCAD dimensions as symbols in Pro/ENGINEER. Yes - Flags independent copy geom features in a pre-2000i model as modified when retrieved into Pro/ENGINEER. Save the model immediately to update the model's copy geom dependency information. Sets the default copy geometry reference(s) type 15 yes, no yes, no, as_symbol no, yes yes, no no

Category

Description

Values

Default value

company_name

Environment

compress_output_files

File Storage & Retrieval

conf_mouse_anim

Miscellaneous

yes

contact_surfaces_gap

Without category

0 no no

convert_to_wf3_replace

Without category

copy_dxf_dim_pict

Data Exchange

copy_geom_update_pre_2000i_dep

Assembly

no, yes

copy_geometry_method

Assembly

publish_geometry, references

publish_geometry Pro/ENGINEER Wildfire 5.0 Configuration Options

Parametric Technology Corporation

Name If set to yes, allow to copy set datum associated with datum features.. Set up the number of threads including main thread Yes - Saves all new driven dimensions created in the drawing inside the drawing as associative draft dimensions. No Saves driven dimensions created in Drawing mode on solid geometry in the solid. Yes - All dimensions created will be displayed as fractions. Yes - Creates default layers named 1 through 32. Allow the automatic creation of interfaces based on previous assembly instructions. Activates "Graft features" button under File menu. This allows user to graft features created in CRI model to active model. Sets the CTI class color file for CTI class color displayduring electrical clearance and creepage analysis.Use the full pathname to avoid problems. Specifies the default color used to display the current component in a process assembly. Specifies the default font used on the current component in a process assembly. 0 yes, no yes, no yes, no yes, no no no no no yes, no no 2 yes, no yes

Category

Description

Values

Default value

copy_set_datum_attr

Features

cpus_to_use

System

create_drawing_dims_only

Drawing

create_fraction_dim

Dimensions & Tolerances

create_numbered_layers

Layers

create_temp_interfaces

Assembly

cri_grafting_enable

Data Exchange

cti_class_color_file

Electromechanical

curr_proc_comp_def_color

Assembly Process

curr_proc_comp_def_font

Assembly Process

Parametric Technology Corporation

16

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Used to specify fringe colors in Pro/FEMPOST results. Specify blue, black, cyan, magenta, green, yellow, red, and white. Enter colors as a dash-delimited string (lowest to highest value). The default is blue-cyan-green-yellow-red-magentawhite. Specifies the shape of datum point symbols displayed in Part or Assembly mode. Specifies the units to be used for data imported in Dazix files. Yes - Causes the MOUNTHOLE section of a Dazix file to be processed as a mount hole.No - Causes the MOUNTHOLE section to be processed as a cut. Yes - Passes the objects in the .edn files through z translation. Specifies default layer names for different types of items. The first value string is the layer type. The second value string is the layer name. yes, no layer_3d_items, layer_ae_driving_dim, layer_all_detail_items, layer_annotation_element, layer_assem_member, layer_assy_cut_feat, layer_axis, layer_axis_ent, layer_chamfer_feat, layer_comp_design_model, layer_comp_fixture, layer_comp_workpiece, layer_copy_geom_feat, layer_corn_chamf_feat, layer_cosm_round_feat, layer_cosm_sketch, layer_csys, layer_csys_ent, layer_curve, layer_curve_ent, 17 yes, no micron, mm, thou no dot, cross, circle, triangle, square cross

Category

Description

Values

Default value

custom_rainbow

Without category

datum_point_symbol

Model Display

dazix_default_placement_unit

Data Exchange

dazix_export_mounthole

Data Exchange

dazix_z_translation

Data Exchange

yes

def_layer

Layers

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name layer_cut_feat, layer_datum, layer_datum_plane, layer_datum_point, layer_detail_item, layer_dgm_conn_comp, layer_dgm_highway, layer_dgm_rail, layer_dgm_wire, layer_dim, layer_draft_constr, layer_draft_dim, layer_draft_dtm, layer_draft_entity, layer_draft_feat, layer_draft_geom, layer_draft_grp, layer_draft_hidden, layer_draft_others, layer_draft_refdim, layer_draft_xsec, layer_driven_dim, layer_dwg_table, layer_ext_copy_geom_feat, layer_feature, layer_geom_feat, layer_gtol, layer_hole_feat, layer_hole_thread, layer_intchg_funct, layer_intchg_simp, layer_nogeom_feat, layer_note, layer_parameter_dim, layer_part_refdim, layer_poin Defines the default absolute part accuracy. Specifies the number of decimal places shown in angular dimensions in a drawing. 0 1

Category

Description

Values

Default value

default_abs_accuracy

Environment

default_ang_dec_places

Drawing

Parametric Technology Corporation

18

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the display of newly created angular dimensions to decimal degrees (ang_deg),degrees and decimal minutes (ang_min) or degrees, minutes and decimal seconds (ang_sec) both in the model and in the drawing. Does not affect dimensions that already have been created. ang_deg, ang_min, ang_sec ang_deg Set the specified Shared Geometry reference control conditions to newly added components. Set the specified handling method of outof-scope Accessible references to newly added components. Set the specified Accessible reference control conditions to newly added components. Set the specified Shared Geometry reference control conditions to newly added Skeleton components. Set the specified Accessible reference control conditions to newly added Skeleton components. Sets the default number of decimal places (0-14) to display in all model modes for non-angular dimensions. It does not affect the display of dimensions modified using Num Digits. In Sketcher, sketcher_dec_places controls the number of decimal places. Sets Full Dependent Copy as a default copy option. full_dep, dep_dim copy, prohibit all, pg, none all

Category

Description

Values

Default value

default_ang_units

Dimensions & Tolerances

default_comp_geom_scope

Without category

default_comp_invalid_refs

Without category

copy

default_comp_scope_setting

Without category

all, none, subassemblies, skeleton_model all, pg, none

all

default_comp_skel_geom_scope

Without category

all

default_comp_skel_scope_setting

Without category

all, none, subassemblies, skeleton_model

all

default_dec_places

Dimensions & Tolerances

default_dep_copy_option

Features

dep_dim

Parametric Technology Corporation

19

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default number of digits displayed in a dimension to the last entered value. No - The system defaults to the value specified for the configuration file option default_dec_places. Sets the default drawing scale for views added with the No Scale command. The value must be greater than 0. No - The system does not set a default drawing scale. Set default scope for externally referenced models. All - Any model. None - Only current model and children. Skeletons Any component in model's assembly and higher skeletons on branch. Subassembly - Only components and children in model's assembly. Sets font for text other than menu bar, menus and their children, and pop-up menus and help. Add comma-delimited variables in any order (italic bold, 24, times or 24, times, italic bold have the same effect). Any omitted variable uses standard setting. Determines initial setting of Font kerning when 2D drawing annotations are created. Yes - Font kerning is on for new 2D annotations. Default save type for geometry analysis. Default value for Geometry Scope allowed for referencing. Name of the model which is used to drive rule-based layer placement of new items in all models of the same type in session. 20 yes, no no all, none, subassemblies, skeleton_model all -1 yes, no yes

Category

Description

Values

Default value

default_dim_num_digits_changes

Dimensions & Tolerances

default_draw_scale

Drawing

default_ext_ref_scope

Without category

default_font

User Interface

default_font_kerning_in_drawing

Drawing

default_geom_analysis_type

Without category

quick, saved, feature all, pg_if_exists, pg_only

quick all

default_geom_scope

Without category

default_layer_model

Layers

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Default Value for Mold Base vendor. Set the specified Shared Placement reference control conditions to newly created models if template models were not used. Set the specified Shared Geometry reference control conditions to newly created models if template models were not used. Sets default condition for reference handling. Prohibit - System will abort all attempts to create ext. reference that violates scope. Copy - System will issue warning upon all attempts to create ext. reference that violates scope. Set default condition for reference control. All - Any model. None - Only current model and children. Skeletons - Any component in model's assembly ang higher skeletons on branch. Subassembly - Only components and children in model's assembly. Default value for Component Placement Reference filter. Sets the default placement type for surface finishes within the surface finish UI. Specifies a number of shades of gray to show shading of non-colored objects. copy, prohibit all, pg, none all all, interfaces, none all futaba_mm, dme, hasco, dme_mm, hasco_mm

Category

Description

Values

Default value

default_mold_base_vendor

Casting & Mold Design

default_obj_constraints_scope

Without category

default_object_geom_scope

Without category

default_object_invalid_refs

Without category

copy

default_object_scope_setting

Without category

all, none, subassemblies, skeleton_model

all

default_placement_scope

Without category

all, intrf_if_exists, intrf_only with_leaders, on_entity, normal_to_entity, free

all normal_to_entity

default_placement_surfacefinish

Dimensions & Tolerances

default_ramp_size

Model Display

Parametric Technology Corporation

21

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Complete path to the scene file to be used as default scene file.

Category

Description

Values

Default value /devsrc1/spg/system_1 /graphiclibrary/scenes//defaultenhanced-realism.scn

default_scene_filename

Photorender

default_shrink_formula Yes - A plot file is automatically deleted from the directory in which it resides when it has been successfully plotted. Depth cue aids in visualizing a wireframe model. With depth cue enabled, wireframe lines become darker as they extend into the screen and lighter as they extend towards the screen. Depth cue is supported only by the appropriate graphics hardware. Aids in visualizing a wireframe model. With depth cue enabled, this option specifies the default percentage of depthcue used. Depth cue is supported only by the appropriate graphics hardware. YES: Allow user to save a copy of loaded diagrams as DGE file for loading into Routed Systems Designer, NO: Do not provide option to save a diagram as DGE. (Diagram) Determines the Pro/TABLE format used when you are modifying pin parameters. "yes" - You can add userdefined pin parameters by including them between the DEFINE and ENDDEF statements for each pin. "no" - The system uses columnar format no, yes no no, yes yes, no

Casting & Mold Design

Default option of shrinkage formula: 1/(1S) - ASME standard or 1+S (simple).

asme, simple

simple

delete_after_plotting

Printing & Plotting

depthcue_always

Model Display

yes

depthcue_value

Model Display

diagram_export_allow

Electromechanical

diagram_pin_edit_multi_line

Electromechanical

yes, no

no

Parametric Technology Corporation

22

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the language in which the dialog display when running non-English version of Pro/ENGINEER. Sets the largest denominator to be used for fractional dimensions. If the fraction can be reduced, then it converts to the lowest possible denominator (for example, 4/32 converts to 1/8). Std - Displays fractional dimensions in the standard Pro/ENGINEER format. Aisc Displays fractional dimensions in the American Institute of Steel Construction (AISC) format and displays architectural units in AISC format for feet-inches. Display inactive assembly components with stippled transparency and default color (grey). Default value is shade_only. If more than zero, sets the margin beyond which dimensions are automatically snapped back onto the screen.For example, a value of .2 lets a dimension be 20% of the window size outside the window.If set to zero, disables snapping of offscreen dimensions. If set to YES line priority in plotting or export is determined according to DIN standard. Specify the maximum number of directories to cache.Larger values can speed up file access, but use more memory. Yes - Enables direct VRML conversion. yes, no yes, no std, aisc std 32 yes, no yes

Category

Description

Values

Default value

dialog_translation

User Interface

dim_fraction_denominator

Dimensions & Tolerances

dim_fraction_format

Dimensions & Tolerances

dim_inactive_components

Assembly

always, never, shaded_only

shaded_only

dim_offscreen_limit

Dimensions & Tolerances

0.2

din_std_line_priority

Printing & Plotting

no

dir_cache_max

File Storage & Retrieval

256

direct_vrml

Data Exchange

no

Parametric Technology Corporation

23

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls whether the search path is checked for name conflicts when creating, renaming, or copying models. Name conflicts should be avoided because different models with the same name cannot be together in session. Simplified Rep to display initially in Open Rep Create: "No" for none, "Yes" for graphics rep, or "Default Rep" to display the rep indicated by option "open_simplified_rep_by_default". Displays the model in default orientation when placing a general view on the drawing. No - Model does not appear until Default is chosen from the Orientation dialog box. Wireframe - All solid edges in white. Hiddenvis - Hidden lines in grey. Hiddeninvis - Hidden lines removed. Shade - Display shaded surfaces. Settings are reflected in printing and some export modes. Determines whether or not annotations are displayed in 3D models. Displays or hides datum axes. Displays or hides datum axis name tags. Yes - The design model goes into memory and displays. Pick process components from the design model or the Model Tree. No - Only the Model Tree displays. As you pick process components from the Model Tree, they go into memory. yes, no yes, default rep, no no yes, no no

Category

Description

Values

Default value

disable_search_path_check

File Storage & Retrieval

disp_in_open_rep_create

Without category

disp_trimetric_dwg_mode_view

Drawing

yes

display

Model Display

wireframe, hiddenvis, hiddeninvis, shade

shade

display_annotations

Environment

yes, no yes, no yes, no yes, no

yes yes yes yes

display_axes

Model Display

display_axis_tags

Model Display

display_comps_to_assemble

Assembly Process

Parametric Technology Corporation

24

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Coordinate systems will be displayed. No - Coordinate systems will not be displayed. Yes - Coordinate system name tags will be displayed. No - Coordinate system name tags will not be displayed. When set to yes, parametric sketching constraints, such as V for vertical, are displayed when a drawing object is selected Sets the display of the tolerance tags that appear in drawings. This option does not affect the display of tolerances on dimensions. Yes: display of the florin (international currency symbol) where possible. No: use the euro symbol exclusively. Controls the display of the object's full file name (including its object-type suffix and its version number) and file path in the window title and Model Info display. Yes Displays full file name and file path. No Displays object name only. Controls model display in a drawing when auto_regen_views is No. Wireframe - Adds new views in wireframe, displays datums. Minimal_wireframe - Displays in wireframe, no datums, axes, or silhouette edges. Default - Displays using the Environment setting. no, yes no, yes yes, no yes, no no yes, no yes yes, no yes

Category

Description

Values

Default value

display_coord_sys

Model Display

display_coord_sys_tags

Model Display

display_dwg_sketch_constraint

Drawing

display_dwg_tol_tags

Drawing

yes

display_florin

Model Display

no

display_full_object_path

Environment

no

display_in_adding_view

Drawing

wireframe, minimal_wireframe, default

wireframe

Parametric Technology Corporation

25

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Internal cable portions will be displayed for any wires that have been manually set to Yes in the Cable Paths Setup dialog box for each individual splice and custom component. This option can be overridden in the Environment dialog box. This causes the specified layers to display when you begin a Pro/ENGINEER session. The variable "value" is the layer Id. Yes - Datum plane name tags will be displayed. No - Datum plane name tags will not be displayed. Yes - Datum planes will be displayed. No Datum planes will not be displayed. Yes - Datum point tags will be displayed. No - Datum point tags will not be displayed. Yes - Datum points and their names will be displayed. No - Datum points and their names will not be displayed. Sets the display of silhouette edges for wireframe display only. Yes - Display cables and wires with thickness. No - Display the centerline of cables and wires only. This option can be overridden in the Environment dialog box. Yes - Display insulation in thick mode. No Display insulation in centerline mode. This option can be overridden by the Thick insulation option in the Model Display dialog box. 26 yes, no yes, no yes, no yes yes, no no

Category

Description

Values

Default value

display_internal_cable_portion

Electromechanical

display_layer

Layers

display_plane_tags

Model Display

display_planes

Model Display

yes yes

display_point_tags

Model Display

display_points

Model Display

yes, no

yes

display_silhouette_edges

Model Display

no, yes yes

yes no

display_thick_cables

Electromechanical

display_thick_insulation

Piping

yes, no

yes

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Display pipes in thick mode. No Display pipes in centerline mode. This option can be overridden by the Thick pipes option in the Model Display dialog box. If set to Yes, tolerances for non-angular dimensions will be displayed multiplied by 1000. Controls the display of dimension zextension lines. Yes - z-extension lines will be displayed; No - z-extension lines will not be displayed. yes, no yes, no no yes, no no

Category

Description

Values

Default value

display_thick_pipes

Piping

display_tol_by_1000

Dimensions & Tolerances

display_z_extension_lines

Model Display

yes

dm_adv_import_file_types YES - Windchill CAD packages or zip files will open automatically. NO - User selects which file in contents to open. Enter amount of disk space (in megabytes) to allocate for local file storage. The change to the existing setting will take effect after Pro/ENGINEER is restarted Indicate which objects will be written to local cache when objects in Pro/E memory are saved. Controls the default action presented to the user when Check Out on the fly dialog comes up yes, no

Without category yes

dm_adv_import_system_params

Without category

dm_auto_open_zip

Data Management

dm_cache_limit

Data Management

dm_cache_mode

Data Management

none, modified, all

all

dm_checkout_on_the_fly

Data Management

checkout, continue

checkout

dm_enable_import_export_ui

Without category Set the data compression factor (0-9, 0= no compression) for data exchange with a Windchill server. 27

yes, no yes, no

no yes

dm_enable_simple_import_export

Without category

dm_http_compression_level

Data Management

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes: Windchill Workspace Update will overwrite locally/modified out of date objects with the ones in the server. No (Default): Windchill Workspace Update will update metadata only. Primary server/workspace must be set by user for each Pro/E session. Controls the default option for Save A Copy when models are saved as in nonPro/E format. Yes - It will by default save it as secondary content attachment to the original CAD Document. No- It will by default save it as Primary CAD Document Search the primary server for dependencies not found in the workspace. Indicate when modified Pro/E objects on a secondary server will be moved from the local cache to the user's workspace on the server. Yes: Enables workspace synchronization in the background. No (Default): Workspace synchronization will happen in the foreground. Indicate when modified Pro/E objects will be moved from the local cache to the user workspace on the server. Do not show references derived from relations in Parent/Child viewer. yes, no automatic, explicit yes, no no, yes yes yes, no no

Category

Description

Values

Default value

dm_overwrite_contents_on_update

Data Management

dm_remember_server

Data Management

dm_save_as_attachment

Data Management

dm_search_primary_server

Data Management

yes automatic

dm_secondary_upload

Data Management

dm_synchronize_in_background

Data Management

yes, no

no

dm_upload_objects

Data Management

automatic, explicit

explicit

dont_show_symbol_nodes

Design Manager

yes, no

no

Parametric Technology Corporation

28

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Drawing model files are readonly.No model changes can be made.Cosmetic_only - Only cosmetic changes can be made to the model.Design changes are not allowed.Cosmetic changes include adding driven dimensions, cross sections, and explode states. yes, no, cosmetic_only no Defines the current draft view's coordinate values as model units rather than drawing units. The GET POINT menu uses the scale of the draft view and the draft view's model units for relative and absolute coordinate entry and display in the Message Window. Resolution of OLE object images. The range of valid values is 0 to 600 dots per inch. Sets the default drawing setup file option values for your Pro/ENGINEER session, otherwise, the system uses the default drawing setup file option values. Certain parameters in the file are valid only if you have a license for Pro/DETAIL. Resolution of exported shaded drawing views.The range of valid values is 0 to 600 dots per inch. The named coordinate system will be used as the origin of a newly created view or of a modified view.None - The system will not use a previously specified coordinate system. none yes, no no

Category

Description

Values

Default value

draw_models_read_only

Drawing

draw_points_in_model_units

Drawing

drawing_ole_image_dpi

Drawing

150

drawing_setup_file

Drawing

/devsrc1/spg/system_1 /text/prodetail.dtl

drawing_shaded_view_dpi

Drawing

150

drawing_view_origin_csys

Drawing

Parametric Technology Corporation

29

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Allows a user to preset the server policy that is to be used when Apply Policy command is utilized. Provides the ability to choose DWG file version when exporting from Pro/E drawing. Defines the language used during Unicode conversion of pre-Wildfire 4.0 drawings. This option does not affect the conversion of models. File uses the language stored in the drawing header file; Session uses the language of the current Pro/E session. file, session, usascii, english, japanese, french, german, russian, italian, spanish, korean, chinese_tw, chinese_cn, hebrew, greek, turkish, czech, polish, hungarian, slovenian, portuguese, slovak yes, no file 14, 2000, 2004, 2007 2007

Category

Description

Values

Default value

drm_policy_server

User Interface

dwg_export_format

Data Exchange

dwg_unicode_conversion_language

Drawing

dxf_block_to_pro_symbol

Data Exchange

Specifies whether or not DXF BLOCKS to be imported as Pro/E symbols. Yes Imports BLOCKS as symbol definitions, No - Imports BLOCKS as separate entities. Provides the ability to choose DXF file version when exporting from Pro/E drawing. Default, faceted boundary representation is allowed in import. Controls the input support for ACAD_PROXY_ENTITY. YES - comments (999 group codes) will be created in DXF file exported from Pro/ENGINEER. NO - DXF file will be created without comment lines.

no

dxf_export_format

Data Exchange

12, 13, 14, 2000, 2004, 2007

2007

dxf_in_faceted_brep

Data Exchange

yes, no no, yes yes, no

yes yes yes

dxf_in_proxy_entity

Data Exchange

dxf_out_comments

Data Exchange

Parametric Technology Corporation

30

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specify whether or not to export drawing scale to the DXF or DWG file. Yes Includes a scale factor DIMLFAC in the exported DXF/DWG. No - Exports without using a scale for the drawing. Set to Yes when exporting to read into AutoCAD. Specify whether or not to scale drawing views when exporting to theDXF or DWG file.Yes - rescales the entire drawing in such a way that the main viewscale becomes 1:1. No - exports without rescaling. YES - Breaks dimensions with breaks on witness lines to separate entities and preserves the original picture. No - Exports such dimensions as DXF DIMENSION entities and removes the breaks on witness lines. Determines if the SJIS is supported when importing/exporting DXF files in Japanese Defines how imported ECAD areas are treated. Cosm_area - Treats imported ECAD areas as cosmetic area features. 3d_volume - Imports ECAD areas with Zheights as a 3D enclosed quilt. Specifies the default coordinate system name added to an ECAD board being imported. If you do not set this variable, the system prompts you for a name. Specifies the default coordinate system name added to an ECAD component being imported. If you do not set this variable, the system prompts you for a name. 31 yes, no 3d_volume, cosm_area yes, no yes, no no yes, no no

Category

Description

Values

Default value

dxf_out_drawing_scale

Data Exchange

dxf_out_scale_views

Data Exchange

dxf_out_sep_dim_w_breaks

Data Exchange

no

dxfio_in_sjis

Data Exchange

no cosm_area

ecad_area_default_import

Data Exchange

ecad_board_csys_def_name

Data Exchange

ecad_comp_csys_def_name

Data Exchange

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Allow layer mapping for ECAD component's import into Assembly. Will allow pre-setting default X-section to be used for component outline output to *.eda format. Assists in creation of an ecad_hint.map file. Yes - Automatically renames components, if necessary, each time library of component outlines is imported to Pro/ENGINEER. This does not create an ecad_hint.map file. It controls if ecad_hint.add is created. Sets default value and units for an ECAD component being imported. Units can be: inch, mil (1E-3 inches), thou (1E-6 inches), cm, mm, micron (1E-6 meters), dsu (1E-8 meters). If not set, the system uses the current component's units. Sets default component placement status for export (parameter setting will override the default). Supports the export of ECAD areas with different "Above Board" and "Below Board" conditions."yes" - Enables you to export both sided keep-in/keep-out ECAD areas as two individual areas (top and bottom). Exports Pro/ENGINEER cuts as holes to ECAD systems. Exports Pro/ENGINEER holes as cuts to ECAD systems. unplaced, fixed, placed, mcad, ecad yes, no no, yes yes yes, no yes

Category

Description

Values

Default value

ecad_comp_layer_map

Data Exchange

ecad_comp_xsec_def_name

Data Exchange

ecad_create_hint_add

Data Exchange

ecad_default_comp_height

Data Exchange

-1

ecad_default_comp_place_status

Data Exchange

placed

ecad_exp_both_two_areas

Data Exchange

no

ecad_export_cuts_as_holes

Data Exchange

yes, no yes, no

yes no

ecad_export_holes_as_cuts

Data Exchange

Parametric Technology Corporation

32

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Import sections specified as DRILLED_HOLE as through-all holes. Boards created with Pro/ENGINEER drilled holes export with default value of NPTH for the ECAD_HOLE_TYPE parameter. Create this feature parameter if a value of PTH is needed (IDF 2.0/3.0). Defines the relative accuracy used in ECAD import. Controls whether "ECAD import holes configs" (ecad_pin_hole_import & ecad_via_hole_import) will remove holes completely from the import (default) or just pre-set the holes filter UI condition. Specify the ecad_hint.map file that will be used for ECAD operations. Setup default status for missing components in "Investigate Placement" Dialog. Setup the default for the import of ECAD Holes type MTG (IDF 3.0 or IDX ONLY) Specifies the default coordinate system name for the .OTHER_OUTLINE section of an IDF 2.0 ECAD component being imported. If you do not set this variable, the system uses ECAD DEFAULT as coordinate system name. Select how holes that are placed on the board outline be exported. Specifies the default coordinate system name added to an ECAD panel being imported. If you do not set this variable, the system prompts you for a name. 33 default, arcs default keep_missing, delete_missing yes, no, as lightweight keep_missing yes, no 0.0012 no yes, no yes

Category

Description

Values

Default value

ecad_import_holes_as_features

Data Exchange

ecad_import_relative_accuracy

Data Exchange

ecad_load_filtered_holes_to_ui

Without category

ecad_mapping_file

Data Exchange

ecad_missing_component_status

Data Exchange

ecad_mtg_hole_import

Data Exchange

yes

ecad_other_outl_csys_def_name

Data Exchange

ecad_outline_holes_exp_method

Without category

ecad_panel_csys_def_name

Data Exchange

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Setup the default for the import of ECAD Holes from type PIN (IDF 3.0 or IDX ONLY) Setup the default for the import of ECAD Holes type TOOL (IDF 3.0 or IDX ONLY) Setup the default for the import of ECAD Holes from type VIA (IDF 3.0 or IDX ONLY) Controls display quality of an edge for wireframe and hidden-line removal. Normal - Normal quality of edge display. High - Increases tessellation by 2. Very_high - Increases tessellation by 3. Low - Decreases tessellation from normal, speeds up display. Yes - Display 3DModelSpace tab in the browser when Pro/E starts. No - Display 3DModelSpace tab only when user click a 3DModelSpece link in the navigator Controls display of the ACCURACY menu. Yes - ACCURACY menu always appears when you choose Accuracy from the PART SETUP menu. No - The menu appears only if the part is currently defined with absolute accuracy. Enable ACIS export extension. Enables advance collision settings usage. No - Disables accuracy modification for assembly objects. Enables the CADRA command in the EXPORT menu. This enables the creation of a CADRA specific IGES file. yes, no normal, high, very_high, low yes, no, as lightweight yes yes, no, as lightweight yes yes, no, as lightweight no

Category

Description

Values

Default value

ecad_pin_hole_import

Data Exchange

ecad_tool_hole_import

Data Exchange

ecad_via_hole_import

Data Exchange

edge_display_quality

Model Display

normal

enable_3dmodelspace_browser_tab

Without category

yes

enable_absolute_accuracy

Environment

yes, no

no

enable_acis_export_extension

Data Exchange

yes, no yes, no yes, no no, yes

no no yes no

enable_advance_collision

Assembly

enable_assembly_accuracy

Assembly

enable_cadra_export

Data Exchange

Parametric Technology Corporation

34

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls the ability to "pre-select" faces/datums as an entry to Sketch based features such as Extrude, Revolve (input to the internal sketch). Enables hlr hashing Allow underconstrained components as mechanism connections. Enables fan curve option for offset tool. Controls pop-up help in dialog boxes. Yes - Help enabled. No - Help disabled. Enables XML-Schema validation for Pro/TK feature XMLs Yes - shading display is allowed in drawing views. No - shading display will be shown in wireframe. Setup whether tree customization will allow separating the tree window from Pro/E window. Yes - Global Reference Viewer will show objects with external references only;No all the objects will be visible Sets the default directory for the MS Excel files to be used for Excel analysis calculations. Use the full pathname to avoid problems. Yes - in case of editing family table with excel, if saved excel file exist , will always update it. Execute pro/program for models during assembly retrieval. yes, no no yes, no yes, no yes, no yes, no yes, no yes, no yes no yes no no, yes no yes, no yes

Category

Description

Values

Default value

enable_face_preselection

Without category

enable_hlr_hashing

Model Display

enable_implied_joints

Assembly

enable_offset_fan_curve

Without category

enable_popup_help

User Interface

enable_protk_xml_schema

Application Programming Interfaces

enable_shaded_view_in_drawings

Drawing

yes

enable_tree_indep

System

no

erv_show_external_only

Assembly

yes, no

no

excel_analysis_directory

File Storage & Retrieval

excel_family_table_keep_file

File Storage & Retrieval

exec_prog_on_assem_retr

File Storage & Retrieval

yes, no

no

Parametric Technology Corporation

35

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - expand all including nested sub layers. Sets the maximum amount of time an animation between explode states will take. Controls how dimensions are treated when importing an IGES drawing file. Yes - Each IGES dimension explodes into an independent note with the dimension text and a dimension with an empty note. No Dimensions are treated as before. Specify whether the Pro/ENGINEER model names should be used for STEP export. Yes - Use default naming. No Add suffixes to model file names. Controls the format of the exported reports displayed in the embedded browser. Rich Text - Exports the report in Rich Text format, Comma Delimited - Exports the report in Comma Delimited format. Enable Ship-it interface export. Extends CVPATH search path for CADDS5 data exchanging. Sets the default directory for the files to be used by External Analysis calculations.Use the full pathname to avoid problems. Yes - When using a copied geom feature or a backed-up external reference with the Design Manager, and the reference is missing in the original, then the copied geom feature fails. No - The feature freezes and does not update. yes, no yes yes, no yes, no no 1 yes, no yes

Category

Description

Values

Default value

expand_all_with_nested_layers

Without category

explode_animation_max_time

Model Display

explode_iges_dimension_note

Data Exchange

export_3d_force_default_naming

Data Exchange

no

export_report_format

System

comma_delimited, rich_text

comma_delimited

export_to_shipit

Data Exchange

yes, no

no

extend_cvpath

Data Exchange

external_analysis_directory

File Storage & Retrieval

fail_ref_copy_when_missing_orig

Assembly

Parametric Technology Corporation

36

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Handles unattached protrusion and cuts, when retrieving pre-Release 15 models. Yes - When a part is retrieved, the system fails an unattached protrusion or cut. No When a part is retrieved, the system does not fail an unattached protrusion or cut. Setup whether only significant locations should be flattened on flattening a harness. Setup whether the network should be included on flattening a harness. Yes - Use simplified highlighting which redisplays more quickly at the expense of certain details.This option may increase memory usage slightly. Specifies whether fast hidden line removal is on/off by default. In feature creation, determines whether or not the Define button is automatically activated when you open the dialog box. Yes - Button is activated automatically. No - You select the button. In feature creation, determines whether or not the system activates the dialog box OK button automatically when the last required element is defined. Yes - Button is activated automatically. No - You select the button. Yes - The user will be prompted to select a file to retrieve the mesh from, or enter a file name to save the mesh to. No - The user will not be prompted to select or enter a mesh file name. 37 no, yes yes, no no, yes yes, no yes, no yes yes, no no

Category

Description

Values

Default value

fail_unattached_feature

Features

fan_significant_locations_only

Electromechanical

fan_with_network

Electromechanical

yes yes

fast_highlight

Model Display

fasthlr

Model Display

no no

feature_create_auto_begin

Features

feature_create_auto_ok

Features

yes, no

no

fem_allow_named_mesh_files

Without category

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Toggles transfer of loadcase names to ANSYS. Toggles transfer of groups/layers to ANSYS. The value that FEM created elements of aspect ratio are compared against. Specifies default solver. The value that FEM created elements of distortion indices are compared against. Sets the minimum acceptable default angle between adjacent element edges. Enter value between 0 and 90. Yes - All Solver files will be retained after running the analysis. No - All Solver files will be deleted after running the analysis. Yes - The menu item Operations appears in the FEM MESH menu, providing access to functionalities to manipulate the finite element mesh. No - the menu FEM MESH will not have the item Operations. Yes - The finite element mesh will be automatically stored in the mesh file upon creation, and retrieved on entering the Structure/Thermal. No - The mesh will not be stored or retrieved automatically. The value that FEM created elements of mid ratios are compared against. Specifies version number of neutral file. Sets the default shell element type in FEM mode. 38 tri, quad yes, no yes, no ansys, nastran 0.4 7 yes, no no yes, no no

Category

Description

Values

Default value

fem_ansys_annotations

Without category

fem_ansys_grouping

Without category

fem_asp_ratio

Without category

fem_default_solver

Without category

fem_dist_index

Without category

fem_edge_angle

Without category

30

fem_keep_solver_files

Without category

no

fem_mesh_operations

Without category

no

fem_mesh_preserve

Without category

yes, no

no

fem_mid_ratio

Without category

0.1 3 quad

fem_neutral_version

Without category

fem_shell_elem_type

Without category

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the maximum acceptable default skew angle value, measured in degrees. Enter a value between 0 and 90. For NASTRAN solution, uses this option to interrupt the solver after the specified time limit. The default value is 60 minutes. Sets the minimum acceptable default taper value. Enter a value between 0 and 1. Sets the maximum acceptable default warp angle value, measured in degrees. Enter a value between 0 and 90. Specifies the ANSYS equation solver type to be used. Supported solver types: FRONTAL, ITERATIVE (JCG), POWERSOLVER (PCG), ICCG, AUTO, and SPARSE. Specifies the Y-direction based on compressed and uncompressed geometry. The default value is uncompressed. Sets default dir for File>Open. Working_directory - Search working directory. In_session - Search objects insession. Pro_library - Use only if Pro/LIBRARY is installed. Workspace Use only with Pro/INTRALINK.Commonspace - Use only with Pro/INTRALINK. Specify the initial view for file dialogs: "LIST" or "DETAILS". Controls whether the preview area is expanded by default when the file open dialog or local file browser is displayed. yes, no frontal, iterative, powersolver, iccg, auto, sparse 0.5 10 60 45

Category

Description

Values

Default value

fem_skew_angle

Without category

fem_solver_time_limit

Without category

fem_taper

Without category

fem_warp_angle

Without category

fem_which_ansys_solver

Without category

fem_y_dir_compress

Without category

no

file_open_default_folder

File Storage & Retrieval

default, working_directory, in_session, pro_library

file_open_default_view

File Storage & Retrieval

list, details expanded, collapsed

list collapsed

file_open_preview_default

File Storage & Retrieval

Parametric Technology Corporation

39

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls the format of time stamps in file dialogs and the folder browser. The format for the setting is a string consisting of up to seven portions: the year, the month, and the date, the hours, minutes, seconds and am/pm designator. You can enter the portions in any order. Fixes scaling problems with AutoCAD releases earlier than Release 10. Yes Repairs AutoCAD files appropriately. Corrects a problem caused by multiple rotations of a note in a CATIA IGES file. Yes - Rectifies any discrepancies. Sets viewing characteristics for imported CATIA SET files. Yes - Files can have translated views. No - Files cannot have translated views. Sets remnant removal ability for the ReIntersect command in the ASSY FEAT menu. Yes - You can remove remnants. No - You cannot remove remnants. Sets a scale factor for enlarging the size of the flip arrow that appears for feature creation direction (default = 1). Set to yes if user wants to see a layer tree dialog separated from navigator. Determines the relative size of the text in menus and dialog boxes. You must restart Pro/ENGINEER for the change to take effect. Modify grid space in foot units for handle movement. 40 yes, no small, medium, large yes, no yes, no yes, no yes, no no %dd-%mmm-%yy

Category

Description

Values

Default value

file_timestamp_format

Without category

fix_autocad_iges_text_scale

Data Exchange

fix_catia_iges_sym_note

Data Exchange

no

fix_imported_set_view_orient

Data Exchange

no

fix_refs_to_intersections

Assembly

no

flip_arrow_scale

Environment

floating_layer_tree

Layers

no

fonts_size

User Interface

foot_grid_interval

Features

0.083333

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Force the use of the New File Options dialog. Update mass properties parameters even when some of the components of the assembly are not in master rep. Yes - Displays all views of drawings in wireframe. No - Displays views according to the display set for the session (wireframe, hidden, and so on). Assigns a specified setup file to each drawing format. To assign the drawing's parameter values to the format, you must retrieve the drawing's setup file into the format. Determines whether view is animated. Used to set the smoothness of view animation changes. Higher numbers provide more frames/sec, and giving you a smoother animation. Lower numbers cause the view to change more quickly. No - Requires an action to fix the assembly or freeze the component that fails retrieval. Yes - Freezes any component failing retrieval at its last known assembly location. Missing refs using offsets or internal datums do not cause components to freeze. Suspends the cable location at its last known assembly location. Loads feature recognition application. yes, no no, yes yes, no no yes, no no yes, no no

Category

Description

Values

Default value

force_new_file_options_dialog

File Storage & Retrieval

force_upd_assem_mp_in_simp_rep

Assembly

force_wireframe_in_drawings

Drawing

format_setup_file

Drawing

dwgform.dtl

frames_per_sec

Model Display

no 3

frames_per_sec_value

Model Display

freeze_failed_assy_comp

Assembly

no

freeze_failed_cable_locations

Electromechanical

yes, no yes, no

no no

frt_enabled

Without category

Parametric Technology Corporation

41

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Full - Removes hidden lines from view when cables hide other geometry (use when Hidden Line active). Partial - Cables hide other non-interfering cables except when cables route together between same locations. None - Display hidden lines (faster). Setup the default number of entries in the top level Undo/Redo (default = 50). Controls whether updated ProductView .edz files are automatically exported every time a model is saved. Specifies the location of the geometry analysis color scheme file. Yes - Arcs and circles included in outputted Gerber plot files will take this format. Material Global Appearance file path. Specifies the directory containing the post processor files to be used by Pro/NCPOST (GPOST). Sets the optional graphics environment used by certain platforms for running Pro/ENGINEER. Refer to the Installation Guide for a list of defaults and optional graphics. Yes - Makes pick points snap to a grid. No - Turns the grid snap off so that any location can be picked. opengl x_windows starbase xgl win32_gdi yes, no opengl no, yes no yes, no 50 no none, full, partial full

Category

Description

Values

Default value

full_hlr_for_cables

Electromechanical

general_undo_stack_limit

System

generate_viewable_on_save

File Storage & Retrieval

geometry_analysis_color_scheme

File Storage & Retrieval

gerber_360_interpolation

Printing & Plotting

global_appearance_file

Colors

gpostpp_dir

Manufacturing

graphics

System

grid_snap

Sketcher

no

Parametric Technology Corporation

42

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - enables new UDF replacement with family table instances that prevents children failures. No - UDF replacement will work in the same manner as Wildfire 3.0 and earlier releases. Yes - updates replaced group name with replacement group name. No - preserves existing name of the group being replaced if it is a user-given name. Controls display of geometric tolerances in Part. Use like drawing set-up option of the same name. On_bottom - Gtols display at bottom (below additional lines of text). Under_value - Gtols display under dimension value (above additional lines of text). Provides the complete path to the directory containing harness start parts and assemblies Display the tangency lines between cable segments in thick cable display mode. URL of an active Pro/ENGINEER Help Center, if the Help Center is not installed at the default path (along with Pro/E product), of nature http://localhost:/index.jspx. Or, URL of the Pro/ENGINEER Help Center, that is deployed on a web server. Specifies the language in which the short help messages display when running nonEnglish versions of Pro/ENGINEER. Yes Display in native language. No - Display in English. yes, no yes yes, no yes on_bottom, under_value yes, no yes yes, no yes

Category

Description

Values

Default value

group_repl_with_recycle

Without category

group_replace_rename

Without category

gtol_dim_placement

Dimensions & Tolerances

on_bottom

harn_start_model_dir

Electromechanical

harn_tang_line_display

Electromechanical

help_center_path

User Interface

help_translation

User Interface

Parametric Technology Corporation

43

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls the display of erased view outlines (environment option Highlight Erased Views). Yes - Highlights erased views. No - Turns off highlighting for erased views. Yes - Items selected in the model tree are highlighted in the geometry area. Yes - Items selected in the layer tree are highlighted in the geometry area. In drawing mode, highlights new dimensions in red until you repaint the screen. In Drawing, controls quilt display in hidden line removal. Yes - Includes quilts in the hidden line removal process (preselects Qlt HLR in the VIEW DISP menu). Default in the VIEW DISP menu, uses the value you have set. Controls whether HLR to be enabled for crosshatches in drawing mode. No- Uses hole-table-driven standard hole diameter value. Yes - Allows specifying the drilled hole value instead of the standard value. Specify Hole tool to use external hole parameter (.hol) files. Specifies the directory path for a standard screw-size parameters (.hol) file to be loaded from disk. Use the full path name to avoid problems. no, yes yes, no yes, no yes, no yes, no yes, no yes yes no yes, no yes

Category

Description

Values

Default value

highlight_erased_dwg_views

Drawing

highlight_geometry

Environment

highlight_layer_items

Layers

highlight_new_dims

Drawing

hlr_for_quilts

Drawing

no

hlr_for_xhatches

Electromechanical

yes no

hole_diameter_override

Features

hole_file_resolution

Features

replace_with_external, use_internal

replace_with_external

hole_parameter_file_path

Features

Parametric Technology Corporation

44

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines how many other Pro/ENGINEER windows/menus are iconified when one window is iconified. Yes - All the windows and menus are iconified. No - Only the selected window is iconified. yes, no Determines whether IGES entities are clipped with regards to IGES views. YES Entities outside the view outline are clipped. NO - No clipping. Determines how IGES notes are clipped with regards to IGES views. No_clip - No clipping. Full_clip - Notes that are partially outside the view outline are clipped. Partial_clip - Notes completely outside the view outline are clipped. Yes - Exports drawing view information. No - Does not export drawing view information. Controls if imported IGES associative dimensions remain associative. Yes - If the drawing setup option associative_dimensioning is Yes, then the Associativity Instance entity is processed during import. No - Dimensions do not retain associativity. Yes - Import RGB information to IGES files. The color definition entities in the IGES file are imported to the drawings as user-defined colors. No - The colordefinition entities in the IGES files are ignored when importing to the drawing. yes, no no_clip, full_clip, partial_clip yes, no no yes no, yes yes

Category

Description

Values

Default value

iconify_entire_pro

User Interface

idd_repair_tangency

Without category

iges_clip_view_ent

Data Exchange

iges_clip_view_note

Data Exchange

no_clip

iges_export_dwg_views

Data Exchange

no

iges_in_assoc_dim_geom_21

Data Exchange

yes, no

no

iges_in_dwg_color

Data Exchange

yes, no

no

Parametric Technology Corporation

45

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls the import of user-defined line fonts. Yes - Give default names to userdefined line styles without names in order ("IGES_1," "IGES_2" etc.). No - Imports the user-defined line fonts as Solid line font. Yes - Converts an IGES group to drawing layers. No - The IGES group is not converted. Determines what to do when IGES note entities do not point to any views or the drawing entity. See the configuration option iges_zero_view_disp. Default - Outputs all surfaces as appropriate IGES surfaces. 114 - This option applies only to representations of surface shape. Trimmed surface entities (type 144) are exported regardless of setting. 128 - Outputs all surfaces as IGES B-spline surfaces. Set default for assembly export via IGES. Flat - Single level model. One_level - Assy structure with pointers to components. All_levels - Assy structure with all comps to IGES files. All_parts - Assy to IGES files with geominfo of comps and assy feats. Yes - Enables the desired width of a gtol symbol to be exported to CATIA. Yes - Breaks a large note (greater than 70 strings) down into smaller notes, each producing an IGES entity. flat one_level all_levels all_parts 128, 114, default as_geometry, all_views, no_views, as_is no, yes no yes, no no

Category

Description

Values

Default value

iges_in_dwg_line_font

Data Exchange

iges_in_group_to_dwg_layer

Data Exchange

iges_note_disp

Data Exchange

all_views

iges_out_all_srfs_as

Data Exchange

default

iges_out_assembly_default_mode

Data Exchange

flat

iges_out_catia_gdt_width

Data Exchange

yes, no yes, no

no no

iges_out_catia_notes

Data Exchange

Parametric Technology Corporation

46

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Enables the export of RGB information to IGES files. The user-defined colors in the drawing are exported to an IGES file as color definition entities. No Ignores the user-defined colors in the drawing when exporting IGES file. Controls the export of user-defined line font through IGES. No - Exports all geometry as solid font. True - Exports all geometry entities, other than lines or arcs, as third-degree Bsplines. False - Does not export entities as third-degree B-splines. Yes - Specifies IGES output with special JAMA-IS subset specification, compliant with the version 1.02 of JAMA-IS (Japan Automobile Manufacturers Association IGES Subset Specification). No - Specifies normal IGES. Yes - Specifies IGES output that uses the MIL-D-28000 entity subset. Converts all part geometry spline curves to IGES entity 126 (B-spline) when creating an IGES file. Converts all part geometry spline surfaces to IGES entity 128 (B-spline) when creating an IGES file. Yes - Exports the text specified by system_iges_header_file and user_iges_header_file as a note on the drawing. To control note placement, use the configuration file option put_iges_drawing_entity. 47 yes, no no, yes yes, no true, false yes, no no yes, no no

Category

Description

Values

Default value

iges_out_dwg_color

Data Exchange

iges_out_dwg_line_font

Data Exchange

iges_out_ent_as_bspline

Data Exchange

FALSE

iges_out_jamais_compliant

Data Exchange

no

iges_out_mil_d_28000

Data Exchange

no yes

iges_out_spl_crvs_as_126

Data Exchange

iges_out_spl_srfs_as_128

Data Exchange

no, yes

yes

iges_out_start_note

Data Exchange

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Exports a drawing symbol as an IGES general symbol entity, IGES type number 228 (yes), or as its component entities: notes and lines. Sets the maximum value for the distance between an XYZ trimming curve (boundary) and the underlying surface of a trimmed surface Controls whether or not XYZ data is output in addition to UV data for trimmed surfaces. Yes - Exports all surfaces to IGES entities 141 and 143. This overrides option iges_out_trm_xyz. When IGES geometry does not point to any views or the drawing entity. All_views Creates a copy of the entity for each view. No_views - Does not create the entity at all. As_is - Creates the entity once, using only its own transformation information. Controls whether object-specific reference scope settings are ignored or not. Environment scope settings will still be enforced. See also allow_ref_scope_change and default_ext_ref_scope Ignore Export Geometry settings. Modify grid space in inch units for handle movement. yes, no no, yes yes, no yes -1 yes, no yes

Category

Description

Values

Default value

iges_out_symbol_entity

Data Exchange

iges_out_trim_curve_deviation

Data Exchange

iges_out_trim_xyz

Data Exchange

iges_out_trm_srfs_as_143

Data Exchange

no

iges_zero_view_disp

Data Exchange

all_views, no_views, as_is

all_views

ignore_all_ref_scope_settings

Without category

no

ignore_export_geom_declaration

Without category

yes, no

no 0.125

inch_grid_interval

Features

Parametric Technology Corporation

48

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Setup the default format type for information presentation. Text information will be output as simple text. HTML - information will be output as html data. Sets default method for presenting information. Both - View information on screen and write information to file. Screen - View information on screen only. File Write information to file only. Choose Select method from the INFO OUTPUT menu. Specifies a constant used to determine the neutral bend line for a sheet metal part. This value is always used for noncylindrical bends. It is used for regular bends only when no bend table is specified. Warns the user that they are initiating a DRM session.When set to "no", this warning dialog will be skipped. Specifies extent of instance search. Yes Include file type when entering instance name in File>Open: type ininput panel (e.g. inst_name.prt) or select in drop-down list. If no .idx files are found, only working dir issearched; each generic is not. Sets amount of checking for overlapping lines and collecting lines of same pen color before exporting plot or 2-D file. 0 No check or collection. 1 - No check, but collection. 2 - Partial check and collection. 3 - Complete check and collection. yes, no choose, screen, file, both both html, text html

Category

Description

Values

Default value

info_output_format

Environment

info_output_mode

Environment

initial_bend_y_factor

Sheetmetal

0.5

initial_drm_warning

User Interface

yes

instance_search_exhaustive

File Storage & Retrieval

no, yes

no

interface_quality

Data Exchange

Parametric Technology Corporation

49

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Allows the user to solidify all closed quilts during import CADDS5 model. Allows the user to switch between the default and alternate converter version for interface with CADDS5 Specifies not to generate or generate short or long log files for data exchange import operations. Yes - Converts an IGES or DXF point entity to a drawing point. Controls if associativity in an imported IGES view is preserved. 3D_VIEWS - tries to create 3D views if 3D model exists in the file. 2D_VIEWS - Imported IGES views work as 2D. No - Imported IGES views are exploded and become unrelated. Default, no profiles in a data exchange file will be extracted for use. none, comp, all no, 2d_views, 3d_views yes, no no, short, long short 14, 13, 15 14 yes, no no

Category

Description

Values

Default value

intf_cadds_import_make_solid

Data Exchange

intf_cadds_version

Data Exchange

intf_generate_log_file

Data Exchange

intf_in_dwg_pnt_ent

Data Exchange

no 2d_views

intf_in_dwg_view

Data Exchange

intf_in_extract_profiles

Data Exchange

none

intf_in_granite_direct_enable

Data Exchange

Allows the user to switch back to the old 'Import Feature' method of reading Desktop .des files and Granite .g files into Pro/E. By default, Pro/E directly opens these models. Specifies the name of the existing import profile to use by default. Exports all B-splines as Bezier surfaces. Export assembly components and instances using MAPPED ITEM entity.

yes, no

yes

intf_in_profile_default

Data Exchange

intf_out_as_bezier

Data Exchange

yes, no yes, no

no no

intf_out_asm_mapped_item

Data Exchange

Parametric Technology Corporation

50

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls how entity names are handled when an object is exported to STEP format from part or assembly mode. You can give unique names to Pro/ENGINEER datum points, datum axes, datum curves, surfaces, edges, and quilts. Yes - Automatically assigns interface IDs for layers that were not assigned IDs during export. No - Does not assign interface IDs for layers that were not assigned IDs during export. Filters export of entities based on their blank status Specifies Catia start model to be used for CATIA II .model export. Sets the ProductView recipe file for export to .ed and .edz formats. For use with Windchill 8.0 and earlier servers Layer mapping mechanism providing an ability to group entities to layers or blocks. none, part_layer, block_layer, block_nested_layer, block_view_based_layer, block_nested_view_based_la yer none yes, no yes, no no no_name, user_name, id_name no_name

Category

Description

Values

Default value

intf_out_assign_names

Data Exchange

intf_out_auto_layer_ids

Data Exchange

intf_out_blanked_entities

Data Exchange

yes

intf_out_cat_start_model

Data Exchange

intf_out_ed_recipe_file

Data Exchange

intf_out_layer

Data Exchange

intf_out_layer_rename_table

Data Exchange

Enables you to assign interface ids to layers during export Controls the maximum degree of exported B-spline surfaces when exporting through IGES Sets the ProductView recipe file for export to .pvs and .pvz formats. For use with Windchill 9.0 and later servers 16

intf_out_max_bspl_degree

Data Exchange

intf_out_pvs_recipe_file

Data Exchange

Parametric Technology Corporation

51

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets text length in exported 2-D. As_is Width of each character is width of strokes. Full_size - Width of each character is width of character text box. Adjusted - Adjusts spacing so no extra space left and end/start character do not overlap. YES - When exporting a Pro/E model as PDF U3D file, create a U3D file of the same name as the PDF file. Specifies the directory where import and export profiles are kept. Use the full path to avoid problems. Sets the directory for user defined ProductView recipe files Sets the version of Unigraphics interface. Yes - IGES,DXF,STEP files with variable sized sheet information are imported andput on the appropriate variable-size format. Without a sheet size, the system tries to apply the correct variable-size format.No - The IGES,DXF,STEP drawing isplaced on a standardsized format. YES - For import and export, fixes compatibility problems between 2-D external formats (such as IGES and DXF) and Pro/ENGINEER. YES - Exports draft xhatching as IGES sectioned area entity. NO - exports draft xhatching as separate geometric entities. nx3, nx4, nx5 no, yes nx4 yes yes, no no as_is, full_size, adjusted full_size

Category

Description

Values

Default value

intf_out_text_length

Data Exchange

intf_pdf_u3d_create_u3d_files

Without category

intf_profile_dir

Data Exchange

intf_pv_recipe_dir

Data Exchange

intf_ug_version

Data Exchange

intf_use_variable_size

Data Exchange

intf2d_fit_incompatible_data

Data Exchange

yes, no

no

intf2d_iges_out_hatch

Data Exchange

yes, no

no

Parametric Technology Corporation

52

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name YES - Ignore the 3DSOLID entities, if they exist, in the DXF/DWG file being imported in Drawing mode. Only, the 2D entities are processed.NO - Create an assembly by processing the 3DSOLID entities in the DWG/DXF file being imported in Drawing mode. This is the default value for this option. yes, no no Create a single multi-line note on importing multi-line text when is set to YES. Specifies the mapping file for DXF and DWG import. Absolute or relative path to the file can be used. Yes - Places all sectioned areas boundary imported from the IGES file in one layer named IGES_HATCH_BOUNDARY. NO Does not place sectioned areas boundary in one layer. Controls whether to import IGES symbols as symbols or entities by default. Yes Import IGES symbols as symbols by default. No - Import IGES symbols as entities by default. Yes - Opens Import Log File in separate window. No - the Log File will not appear in the window. Create a single MTEXT entity for multi-line text notes when is set to YES. As_is - Exports notes to DXF/DWG with their original alignment values. Fit Exports notes with FIT alignment. If set to Yes, non-ASCII characters will be written in UNICODE encoding. 53 yes, no yes, no no yes, no yes

Category

Description

Values

Default value

intf2d_in_acad_ignore_3d

Data Exchange

intf2d_in_create_multiline_note

Data Exchange

intf2d_in_dxf_mapping_file

Data Exchange

intf2d_in_iges_hatch_bnd_layer

Data Exchange

intf2d_in_iges_symbols

Data Exchange

yes

intf2d_in_open_log_window

Data Exchange

yes, no

no

intf2d_out_acad_mtext

Data Exchange

yes, no as_is, fit

yes as_is

intf2d_out_acad_text_align

Data Exchange

intf2d_out_acad_unicode

Data Exchange

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Enables export of blanked layer entities. If an entity is placed on a layer that is blanked and this option is set to YES, the entity will be exported. Yes - Use the old line font mapping in CGM export: hidden lines to type 2, CTRLFONT to type 4, PHANTOMFONT to type 5. No - Use the new mapping: hidden lines to type 12, CTRLFONT to type 11, PHANTOMFONT to type 13. Provides the ability to choose CGM metafile version when exporting from Pro/E drawing. Specifies the mapping file for DXF and DWG export. Absolute or relative path to the file can be used. Controls whether the enhanced entities (SPLINE and HATCHING) are converted to the corresponding DXF entities or represented as separate lines and polylines. Yes - Exports interface IDs of layers as IGES levels. YES - Exports line width information to DXF. NO - all entities are exported with the default width. Yes - Opens Export Log File in special window. No - the Log File will not appear in the window. Yes - Exports a drawing point to IGES, DXF or DWG as a point entity. No Exports a drawing point as shape entities. spline_and_hatch, spline_only, hatch_only, none spline_and_hatch 1, 3 1 yes, no no yes, no no

Category

Description

Values

Default value

intf2d_out_blanked_layers

Without category

intf2d_out_cgm_old_lfont_map

Data Exchange

intf2d_out_cgm_ver

Data Exchange

intf2d_out_dxf_mapping_file

Data Exchange

intf2d_out_enhanced_ents

Data Exchange

intf2d_out_iges_layers_with_id

Data Exchange

yes, no yes, no

no yes

intf2d_out_line_width

Data Exchange

intf2d_out_open_log_window

Data Exchange

yes, no

no

intf2d_out_pnt_ent

Data Exchange

yes, no

no

Parametric Technology Corporation

54

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Strokes == text is converted to lines and dots. "NONE"- Does not stroke out the text for export. "ALL" - Strokes out all the text. "SPECIAL" - Strokes out only special characters. Enables UI to selectively import I-DEAS part and assembly models from the IDEAS .mf1 and .pkg container files. Specifies the path for I-DEAS installation. Use the full pathname to avoid problems. Specifies the I-DEAS run command. Default command is "ideas". No - Join surfaces on import as geometry is loaded from file. Yes - Use new method to join surfaces by layer (surfaces contained on the same layer are joined together first) with a better chance of joining those surface elements to form closed geometry. Export annotations with models. Specifies model parameter IDENT_CRV while exporting to Catia. Specifies model parameter IDENT_PT while exporting to Catia. Specifies model parameter INFINITY while exporting to Catia. Specifies model parameter MODEL_SZ while exporting to Catia. Specifies model parameter SAG while exporting to Catia. Specifies model parameter STEP while exporting to Catia. 55 yes, no yes, no ideas yes yes, no no none, special, all none

Category

Description

Values

Default value

intf2d_out_stroke_text

Data Exchange

intf3d_ideas_import_filter

Data Exchange

intf3d_ideas_install_dir

Data Exchange

intf3d_ideas_run_command

Data Exchange

intf3d_in_enable_layer_join

Data Exchange

intf3d_out_annotations

Data Exchange

yes -1 -1 -1 -1 -1 -1

intf3d_out_cat2_ident_crv

Data Exchange

intf3d_out_cat2_ident_pt

Data Exchange

intf3d_out_cat2_infinity

Data Exchange

intf3d_out_cat2_model_sz

Data Exchange

intf3d_out_cat2_sag

Data Exchange

intf3d_out_cat2_step

Data Exchange

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Allows the user to switch between the default and alternate converter version for export to CATIA V5 Determines whether datum curves are included when exporting IGES files in Batch mode. Controls the type of 3-D data output through Pro/BATCH to an IGES or STEP file. Export as faceted data for formats that support both facet and Brep representations. Specifies how surfaces are handled for exporting files to other systems IGES and PDGS export. Controls normals of non-analytic surfaces. Yes - Forces the surface normals to point in a consistent direction. No - Does not force the surface normals to point in a consistent direction. Specifies product structure to file structure mapping defined in JT Open Toolkit. Exports notes with models. Exports parameters with models. Sets maximum allowable deviation between original and resulting surfaces in the process of converting Pro/ENGINEER surfaces to spline surfaces. By setting this you convert surfaces with a better approximation than by using the current model accuracy. yes, no yes, no facets_only, brep_and_facets,default wireframe, surfaces, wireframe_surfaces, solid, shells, none yes, no no 10, 14, 15, 16, 17, 18 10

Category

Description

Values

Default value

intf3d_out_catia_v5_version

Without category

intf3d_out_datums_by_default

Data Exchange

intf3d_out_default_option

Data Exchange

surfaces

intf3d_out_export_as_facets

Data Exchange

default

intf3d_out_extend_surface

Data Exchange

yes no

intf3d_out_force_surf_normals

Data Exchange

intf3d_out_jt_structure

Data Exchange

per_part, fully_shattered, monolithic yes, no all, none, designated

per_part yes all -1

intf3d_out_notes

Data Exchange

intf3d_out_parameters

Data Exchange

intf3d_out_surface_deviation

Data Exchange

Parametric Technology Corporation

56

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name YES - Unicode strings are exported to the Neutral file, NO - Unicode strings are converted to ascii characters for Neutral file export. Allows user to choose the schema to be used for parasolid export. Default is SCH_10004. Consult online documentation for other valid schema settings. Specifies the path for Unigraphics installation. Use the full pathname to avoid problems. Specifies the mapping between isogen parameter and attribute name. sch_10004 yes, no yes

Category

Description

Values

Default value

intf3d_out_unicode_to_neutral

Data Exchange

intf3d_parasolid_export_schema

Data Exchange

intf3d_ug_install_dir

Without category

isogen_attribute_map_file

Piping

/devsrc1/spg/system_1 /text/piping_data/isodat a/isogen_attribute_ma p.ptd /devsrc1/spg/system_1 /text/piping_data/isodat a/isogen_endtype_ma p.ptd isogen.fls /devsrc1/spg/system_1 /text/piping_data/isodat a/isogen_nominal_size _map.ptd

isogen_endtype_map_file

Piping

Specify name of file mapping Pro/Piping endtypes with ISOGEN endtypes

isogen_mandatory_attr_file

Piping

Specify file containing mandatory attribute filenames used by ISOGEN. Specify name of file mapping Pro/Piping Size with Nominal Sizes in MM and Inches

isogen_nominal_size_map_file

Piping

isogen_output_files_dir

Piping

Specify directory to save the PCFs created by ISOGEN interface Specify format to create filenames of PCF files being created mnemonic,,specification,-,number

isogen_pcf_filename_format

Piping

Parametric Technology Corporation

57

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specify name of file for mapping Pro/Piping selection names with ISOGEN symbol keys (SKEY)s Specifies a command to start JRE for JLink. May contain arguments and environment variables. Overrides the default, see also jlink_java2. Option to force use of Java-2 JRE command line ("java" instead of "jre") On - Enables use of abbreviations when entering menu commands from the keyboard. Provides the ability to select locations in the graphics area via the keyboard.Yes Selection in the graphics area may be performed via the keyboard.No - Selection in the graphics area requires a mouse. Sets the initial state of how the system treats datums and features created at run time. Controls whether a model will be kept displayed in its window while accessory window is used. Keep style entities hidden after exiting of the Style feature definition. Specifies language storage options. The option provides flexibility for objects that use a different language than the current Sets the directory that holds the temp files for the session recording mechanism. yes, no no, yes on, off off, on on

Category

Description

Values

Default value /devsrc1/spg/system_1 /text/piping_data/isodat a/isogen_symbol_map. ptd

isogen_symbol_map_file

Piping

jlink_java_command

Without category

jlink_java2

Application Programming Interfaces

kbd_cmd_abbreviation

User Interface

off

kbd_selection

User Interface

no

keep_info_datums

Features

yes

keep_model_in_open_window

Without category

no, yes

no

keep_style_items_hidden_on_exit

Without category

yes, no yes, no

no yes

lang_propagate

File Storage & Retrieval

last_session_directory_path

Without category

/home/kapig/.wf/.settin gs

Parametric Technology Corporation

58

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Activates recording mechanism that enables the session to be retrieved during the next session. No - The recording mechanism is not available and the session can not be retrieved. Determines whether an object fetched from a PDM database can be renamed in a Pro/Engineer session. An alternate format for setting default linear tolerance dimensions. First value sets the number of decimal places. Second value is the actual tolerance. For example, 6 0.000025 sets tolerance to six decimal places. The default tolerance is 0.000025. Specify a range for default tolerances of linear and angular dimensions. These values affect only models created after the tolerance options are specified in the configuration file. Specify a range for default tolerances of linear and angular dimensions. These values affect only models created after the tolerance options are specified in the configuration file. Specify a range for default tolerances of linear and angular dimensions. These values affect only models created after the tolerance options are specified in the configuration file. 0 no, yes no yes, no yes

Category

Description

Values

Default value

last_session_retrieval

Without category

let_proe_rename_pdm_objects

Data Management

linear_tol

Dimensions & Tolerances

linear_tol_0.0

Dimensions & Tolerances

linear_tol_0.00

Dimensions & Tolerances

linear_tol_0.000

Dimensions & Tolerances

Parametric Technology Corporation

59

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specify a range for default tolerances of linear and angular dimensions. These values affect only models created after the tolerance options are specified in the configuration file. Specify a range for default tolerances of linear and angular dimensions. These values affect only models created after the tolerance options are specified in the configuration file. Specify a range for default tolerances of linear and angular dimensions. These values affect only models created after the tolerance options are specified in the configuration file. Determines whether or not the system uses Level of Detail in shaded models during dynamic orientation (panning, zooming and spinning). When lods_enabled is Yes, this value specifies the default value used to display LODs. The value is a percentage of the edge size vs the total size of the model. Maintains the nominal value of a dimension regardless of the changes that you make to the tolerance values. Automatically adds view names to auxiliary views using AUX VIEW* viewnameviewname. You can modify the view name after adding the view to the drawing. yes, no no, yes 1 1 1

Category

Description

Values

Default value

linear_tol_0.0000

Dimensions & Tolerances

linear_tol_0.00000

Dimensions & Tolerances

linear_tol_0.000000

Dimensions & Tolerances

lods_enabled

Model Display

no

lods_value

Model Display

50

maintain_limit_tol_nominal

Dimensions & Tolerances

no

make_aux_view_notes

Drawing

yes, no

no

Parametric Technology Corporation

60

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines the handling of values entered in a format table when you replace one drawing format with another. Yes - Stores entered values for format table and copies them with the table. No - Prompts you to re-enter all the values for the format table. Automatically adds view names to projection views in the format "VIEW viewname-viewname." You can modify the view name after adding the view to the drawing. Manikin drag auto locks Stores a keyboard macro. Use Tools>Mapkeys to create, edit and delete mapkeys. Mapkeys execution behavior. No Feedback - The mapkey is executed with no feedback, Execute with Feedback - A warning message is given upon failure during execution, Stop at failure - The execution stops at failure and a feedback message is provided. Yes - Displays a tilde (~) in front of a dimension that is set to display as a fraction and has an actual value that is not rounded to equate exactly to the displayed fractional value (the fraction shows 7/32 but the actual value is .22, not 0.21875). Calculate mass properties upon regeneration or by user request. Control whether default appearance in material definition is automatically assigned to a part. 61 no_feedback, execute_with_feedback, stop_at_failure no_feedback yes, no yes, no no yes, no no

Category

Description

Values

Default value

make_parameters_from_fmt_tables

Drawing

make_proj_view_notes

Drawing

manikin_drag_auto_locks

Without category

yes

mapkey

Miscellaneous

mapkeys_execution

Miscellaneous

mark_approximate_dims

Dimensions & Tolerances

yes, no

no

mass_property_calculate

Environment

by_request, automatic yes, no

by_request yes

mat_assign_appearance

Colors

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Defines whether assignment of material to the model via Pro/Toolkit will overwrite existing bend table data and y factor value. Always Replace - Overwrites existing data. Never Replace - Keeps existing data Sets the default directory for the Mathcad files to be used for Mathcad analysis calculations. Use the full pathname to avoid problems. Toggles Mathcad analysis automapping of variables When the orientation, or zoom state, of the Pro/ENGINEER window changes, an animation sequence of a predefined duration takes place. This option controls the maximum time the system spends animating. Set the upper bound dimension on images loaded into Pro/ENGINEER. Images larger than this limit will be rescaled to this upper bound during loading. Specifies the Model Tree configuration file to be loaded when Pro/ENGINEER is started. Path for Custom Load executable. Mass density for dynamics. Enable explicit integration for dynamic analyses. Spring wire radius for dynamics spring icons. yes, no 0 no 0.15 4096, 1024, 2048, 8192, 16384 yes, no no 1 always_replace, never_replace always_replace

Category

Description

Values

Default value

material_upd_smt_bend_table

Sheetmetal

mathcad_analysis_directory

File Storage & Retrieval

mathcad_automapping

Environment

max_animation_time

Model Display

max_image_dimension

Model Display

4096

mdl_tree_cfg_file

User Interface

mdo_cl_executable

Mechanism

mdo_density

Mechanism

mdo_explicit_integration

Mechanism

mdo_spring_wire_radius

Mechanism

Parametric Technology Corporation

62

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name This configuration option controls the number of digits after the decimal point. If value = -1, this configuration is ignored and measure_sig_figures is used Sets the number of significant figures displayed as results when using the Measure dialog box from the Info menu. Specifies the Medusa 2D Interface config. file. Absolute or relative path to the file can be used. Yes - Exports the file in IDF 2.0 format. No - Exports the file in IDF 1.0 format unless IDF 2.0 is selected from the ECAD FORMAT menu. Specify font used in the Pro/ENGINEER menu bar, menus, and all their children. Specify the comma-delimited variables in any order (italic bold, 24, times or 24, times, italic bold have the same effect). Any omitted variable uses the standard setting. outside: Top left corner of Menu Manager is aligned to top right corner of window,inside: Top right corner of Menu Manager is aligned to top right corner of graphics area,adaptive: Behavior is like 'outside' unless there's not enough room available, in which case behavior is like 'inside'. Specify your own URL for the Menu Mapper button in the help menu. Determines whether instance names listed in instance index files appear in file lists. 63 yes, no yes outside, inside, adaptive adaptive yes, no yes 6 -1

Category

Description

Values

Default value

measure_dec_places

Without category

measure_sig_figures

Environment

medusa_2d_config_file

Data Exchange

mentor_ver_2_0

Data Exchange

menu_font

User Interface

menu_manager_position

User Interface

menu_mapper_location

User Interface

menu_show_instances

File Storage & Retrieval

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the language in which the menus display when running non-English version of Pro/ENGINEER. Yes - no edge left at the merge if the sheetmetal surfaces being merged are same surfaces. No - edge is left even between same sheetmetal surfaces. Sets the default merge type surface merge operations. Turns the blue mesh surface lines on or off. Modify grid space in meter units for handle movement. Enable/Disable auto referencing for Manufacturing template Yes - In 3, 4, and 5 axis contour and conventional mill sequences, the entire reference part is selected as check surfaces by default when computing the NC sequence toolpath for those sequences. No - You select the check surfaces. Specifies distance between automatically created retract plane and step coordinate system. Will be applied to the new steps created in process manager if operation retract cannot be used. Defines the file that contains the userdefined tool parameters' list. Yes - Uses the new customize dialog box for customizing NC sequences. No - Uses the Release 19.0 menus. 64 yes, no yes yes, no yes, no no, yes join, intersect yes, no yes yes, no, both yes

Category

Description

Values

Default value

menu_translation

User Interface

merge_smt_srfs_without_seam

Sheetmetal

merge_type

Features

intersect no 0.001 no yes

mesh_spline_surf

Model Display

meter_grid_interval

Features

mfg_auto_ref_mfg_template

Without category

mfg_auto_ref_prt_as_chk_srf

Manufacturing

mfg_auto_retract_clear_dist

Without category

-0.001

mfg_custom_tool_param_file

Manufacturing

mfg_customize_dialog

Manufacturing

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Save / Retrieve Mesh for subsequent cutline recalculations, No New Mesh will be computed for each cutline recalculations. Sets the number of digits for i, j, k data points in a CL data file. top left /bottom right -Position of the mfg. Info dialog box. Enables you to make some of the APTn index topics modal, which means that you repeatedly get a list of major keywords corresponding to this topic upon completing a command line. Do not copy any parameter of the tool to the sequence parameter tree. Specifies the directory where Mfg Process html page get stored. Use the full pathname to avoid problems. Specifies the directory where Mfg Process Table settings get stored. Use the full pathname to avoid problems. Specifies the directory where Mfg Process Templates get stored. Use the full pathname to avoid problems. Specifies the directory which contains all manufacturing related setup files for the current session. Provides the complete path to the directory containing mfg start assemblies. none, all, misc, cutting none top_left, bottom_right 10 top_left yes, no yes

Category

Description

Values

Default value

mfg_cutline_save_mesh

Manufacturing

mfg_ijk_num_digits

Manufacturing

mfg_info_location

Manufacturing

mfg_modal_command_file

Manufacturing

mfg_param_auto_copy_from_tool

Manufacturing

mfg_process_print_dir

Without category

mfg_process_table_setup_dir

Without category

mfg_process_template_dir

Without category

mfg_setup_dir

Without category

mfg_start_model_dir

File Storage & Retrieval

Parametric Technology Corporation

65

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name The factor is used to consider the threading of tapping tool. The estimate removed material value of tapping sequence is presented as estimate removed material value multiplied by this factor. The factor should be greater than 0 and upto 1.0. Specifies the storage directory for NC templates. Specify full path to avoid problems. NC templates are used in Expert Machinist. Templates store the recipe for a toolpath as the method of tool retrieval. Specifies the XML based file to setup Tool Dialog. Specify name and path of the file containing udf and mfg criteria values . Controls the workpiece transparency in shaded model display. You can change the value in the range between 0.1 and 1. The bigger the value, the more transparent the workpiece. The default value is 0.5. Sets the number of digits for x, y, z data points in a CL data file. Modify grid space in millimeter units for handle movement. When the orientation, or zoom state, of the Pro/ENGINEER window changes, an animation sequence of predefined duration takes place. This option controls the minimum number of frames used in the animation sequence. 0.5 1

Category

Description

Values

Default value

mfg_tap_mat_rem_coef

Without category

mfg_template_dir

Manufacturing

mfg_tool_dialog_setup_file

Without category

mfg_udf_info_setup_file

Without category

mfg_workpiece_transparency

Manufacturing

mfg_xyz_num_digits

Manufacturing

10 1 6

millimeter_grid_interval

Features

min_animation_steps

Model Display

Parametric Technology Corporation

66

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls the minimum angle value under which Pro/ENGINEER assumes colinearity of the selected items when creating a driven dimension. Yes - Users can change the scope setting of components. Controls the display of grid balloons. Enables you to specify the prefix to use for negative numbers in the balloon capture of the grid. Controls the number of decimal places displayed in the balloon capture. 0 - Only integers display. Sets the default model grid spacing. Gives the option to display notes as either full text or as label. Can also be toggled with environment option "Display Notes as Names." Sets the default renaming convention for copied assemblies. The default new name is the old name appended with an underscore (_). Adding a template such as [*a1*=*b1*] changes every occurrence of a1 to b1 (e.g. TOP_A1_BRACKET copies to TOP_B1_BRACKET). Toggles display of the Model Tree. Yes Displays the Model Tree window along with its model. No - Does not display the Model Tree window. Enable ModelCHECK no, yes yes no, yes 1.5 no yes, no yes yes, no yes 1

Category

Description

Values

Default value

minimum_angle_dimension

Dimensions & Tolerances

model_allow_ref_scope_change

Without category

model_grid_balloon_display

Environment

model_grid_neg_prefix

Environment

model_grid_num_dig

Environment

model_grid_spacing

Environment

model_notes_as_labels

Environment

model_rename_template

File Storage & Retrieval

model_tree_start

Environment

modelcheck_enabled

Environment

yes, no

yes

Parametric Technology Corporation

67

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines whether the generic name is displayed as an extension of the instance name in the model tree and other model name lists. Yes- During Save a Copy operations, any modified object that is not renamed will be saved in the new directory.No- Any modified object that is not renamed will be saved to the retrieval directory. Sets a specified coordinate system as the default for the cavity layout origin. Do not perform automatic rollback while modifying mold volumes or parting surfaces. Displays the Motion Envelope alert the first time the quality level is increased. Specifies the level of mass properties calculation. Yes - Allows adding an MP_DENSITY column in FT when a material is assigned to a model. When set may cause the same material to have different values for the Density parameter in different instances. Does not affect legacy models. Specifies language in which Messages are displayed when running non-English version of Pro/ENGINEER. If set to "Yes" Pro/E will automatically convert units in materials from a library to the model system of units. Allows/restricts multiple skeleton. yes, no assembly_only, all_models no, yes yes, no no yes, no no yes, no no

Category

Description

Values

Default value

modeltree_show_gen_of_instance

User Interface

modified_objs_in_new_dir

File Storage & Retrieval

mold_layout_origin_name

Casting & Mold Design

mold_vol_surf_no_auto_rollback

Casting & Mold Design

motion_envlp_alert

Mechanism

yes assembly_only no

mp_calc_level

Without category

mp_dens_ft_column_mtrl_assigned

Assembly

msg_translation

User Interface

yes, no

yes

mtrl_convert_units

Assembly

yes, no

yes

multiple_skeletons_allowed

Without category

yes, no

no

Parametric Technology Corporation

68

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the maximum number of cable locations to allow in one feature. To create locations as features, set to 1.To limit the number of locations in one feature, set to a number between 2 and 100. Specifies support of keyboard macros written in native language (for example, German). Location of the setup file that describes which process parameters will be included in the parameter table. Location for storing the report and images generated by the shop floor documentation tool. Location for documentation setup files that describe which process parameters will be included in the parameter table. Location of the style sheet and default images used for shop floor documentation. Yes - make "Submit Path" and "Abort Path" visible. No - make "Submit Path" and "Abort Path"invisible. Vericut will be used for NC material removal simulation. Sets the default file extension for Pro/MFG CL data files. Enter the file extension only (without the preceding "."). For example, apt produces filename.apt. Sets path for storage and retrieval of stock instances for creating workpiece in NC Model. Specify full path, including part name, to avoid problems. yes, no no no, yes no 1

Category

Description

Values

Default value

multipoint_location_count

Electromechanical

native_kbd_macros

User Interface

nc_autodoc_param_dir

Manufacturing

nc_autodoc_report_dir

Manufacturing

nc_autodoc_setup_dir

Manufacturing

nc_autodoc_template_dir

Manufacturing

nc_jobman_visible

Without category

nccheck_type

Manufacturing

vericut, nccheck

vericut ncl

ncl_file_extension

Manufacturing

ncmdl_bar_stock_part_path

Manufacturing

/devsrc1/spg/system_1 /text/ncmdl_data/ncmdl _bar.prt

Parametric Technology Corporation

69

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets path for storage and retrieval of stock instances for creating workpiece in NC Model. Specify full path, including part name, to avoid problems. Set to GPOST to access the default post processor supplied with Pro/NCPOST. Yes - Create out bound curve. Yes - Create out bound curve. Enable the new parameter editor and user interface. yes, no Enable the new relations editor and user interface. Allows to use New turn scan types for Turning NC sequences. Yes - Use Component Chooser base Simp Rep UI, No - Use old Simp Rep definition UI. Specifies the maximum number of different wireframe colors that can display in the graphics area(s) at any given moment. Specifies the color that offset lines are displayed in drawings. Specifies the font in which offset lines are displayed in drawings. Yes - datum properties dialog has button for old-style set datum. No - datum properties dialog does not have button for old-style set datum. yes, no yes yes, no yes, no yes, no yes, no yes yes yes yes yes yes no no gpost, ncpost

Category

Description

Values

Default value /devsrc1/spg/system_1 /text/ncmdl_data/ncmdl _billet.prt

ncmdl_billet_stock_part_path

Manufacturing

ncpost_type

Manufacturing

ncseq_outbnd_curve

Without category

ncseq_outbound_curve

Manufacturing

new_parameter_ui

User Interface

new_ref_part_name_disabled

Without category

new_relation_ui

User Interface

new_turn_scan_type

Manufacturing

new_wf5_simp_rep_ui

Without category

number_user_colors

Colors

-1

offset_line_def_color

Assembly Process

offset_line_def_font

Assembly Process

old_style_set_datum

Without category

Parametric Technology Corporation

70

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specify your own URL for the Online Resources button in the help menu. Set to "Yes" to always invoke the open rep dialog when opening a drawing. Retrieves a model in a specified representation. Yes - uses Open Rep dialog. No - retrieves the Master representation. Specified Name - retrieves the model in the specified representation name if it exists or the Default representation. Establishes the initial standard view orientation. User_default - System uses Xaxis and Y-axis values defined by options x_axis and y_axis. Set spin orientation style to dynamic or anchored. Controls non-90 degree routing in Pro/DIAGRAM. Yes - Turns the Ortho Snap function on. You can sketch wires only at the default horizontal and vertical orientation. No - Enables you to sketch wires in drawings at angles other than the default. Allows export/import mfg model to/from xml file. Yes- make Export/Import options visible. No - make them invisible. Yes - Enables Pro/ENGINEER screens and menus to be placed on different overlay layers of the hardware graphics card. This frees memory for Pro/ENGINEER use. 71 isometric, trimetric, user_default no yes, no no

Category

Description

Values

Default value

online_resources_location

User Interface

open_draw_simp_rep_by_default

File Storage & Retrieval

open_simplified_rep_by_default

File Storage & Retrieval

orientation

Model Display

trimetric

orientation_style

Without category

anchored, dynamic

dynamic

orthogonal_snap

Electromechanical

yes, no

yes

output_mfg_xml

Without category

yes, no

no

overlays_enabled

System

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Forces the storage of objects retrieved from other directories to the current working directory. Action to take for packaged components in Assembly mode. Update - Updates components if assembly changes. Freeze - Does not move components if assembly changes. Disallow - Does not allow packaged components in assembly (must be fully constrained). Control whether alert dialog is given when packaged component is referenced. Yes Allow alert when a packaged component is referenced. No -No Alert is given when a packaged component is referenced. Sets the number of decimal places (0-14) to display in parameters. Setup for the parameter dialog configuration file. Encloses reference dimensions in parentheses. No - Follows reference dimensions with the text "REF". When pattern incremental dimensions are calculated from expressions, round them to the decimal places set by config option default_dec_places. Determines whether relations of pattern leader are inherited by pattern members. 0 - Butt cap: stroked lines are squared off at the endpoint of the path.There is no projection beyond the end of the path. yes, no no yes, no no disallow, freeze, update update yes, no no

Category

Description

Values

Default value

override_store_back

File Storage & Retrieval

package_constraints

Assembly

package_ref_alert

Assembly

param_dec_places

User Interface

parameter_dialog_setup_file

User Interface

parenthesize_ref_dim

Dimensions & Tolerances

pattern_exact_incremental_dim

Without category

no, yes

no

pattern_relations_copy

User Interface

yes, no butt, round, projecting square

yes butt

pdf_linecap

Data Exchange

Parametric Technology Corporation

72

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name 0 - Miter join: outer edges of the strokes for the two segments are extended until they meet at an angle. No - PDF export does not use any defined pentable changes as would be applied to plotting the drawing. Specify how the system parameter, PDM_REV, should be formatted. Only useful for objects submitted to Pro/PDM or Pro/INTRALINK. Sets the pen speed for both x and y directions for plotters that are compatible with this option. Consult your plotter's user guide for more information. Sets the pen speed for the x and y directions individually for plotters that are compatible with this option.The first value is the x value and the second, the y value. They should be separated by a space. Specifies a default pen mapping table which supersedes other pen mapping information. Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). pdmrev_fmt_rev_ver, pdmrev_fmt_rev, pdmrev_fmt_branch_rev_ver, pdmrev_fmt_branch_rev no, yes no miter, round, bevel miter

Category

Description

Values

Default value

pdf_linejoin

Data Exchange

pdf_use_pentable

Data Exchange

pdm_rev

Data Management

pdmrev_fmt_rev_ver

pen_slew

Printing & Plotting

-1

pen_slew_xy

Printing & Plotting

-1

pen_table_file

Printing & Plotting

table.pnt

pen1_line_weight

Printing & Plotting

pen2_line_weight

Printing & Plotting

Parametric Technology Corporation

73

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). Sets the weight of entities plotted with pens using an electrostatic plotter. The weight is a range from 1 (thinnest) to 16 (thickest). Allows the user to disable warnings about PhotoLux only capabilities. Sets the default height (in pixels) for the custom size rendered output Sets the default width (in pixels) for the custom size rendered output yes, no 2 3 2

Category

Description

Values

Default value

pen3_line_weight

Printing & Plotting

pen4_line_weight

Printing & Plotting

pen5_line_weight

Printing & Plotting

pen6_line_weight

Printing & Plotting

pen7_line_weight

Printing & Plotting

pen8_line_weight

Printing & Plotting

photorender_capability_warnings

Photorender

yes 450 600

photorender_default_height

Photorender

photorender_default_width

Photorender

Parametric Technology Corporation

74

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the memory limit that Pro/PHOTORENDER allows for model processing. Do not use commas in the memory value, as Pro/ENGINEER interprets these as decimals. Allows user defined size ratio at which Pro/PHOTORENDER will render, using the default Render To: Full Window Preview setting. Increasing the value creates higher quality rendering with slower performance. Reducing the value produces reverse results. Specifies the size of the area about the mouse when making selections. Units are 1/1000 of screen size. Specifies the extent of draft entity chains selected. Yes - Only entities in the chain that are tangent will be selected. No - All entities connected end to end will be selected. Yes - Displays theoretical intersections and bends in three-dimensional models. Define which assembly units will be used for the piping bend locations calculations. Yes - to use coordinate system assembly units. No - to use pipeline assembly units. Convert bend report information generated prior to Pro/ENGINEER 2000i-2 to current saved analysis format. Yes - Display Pro/PIPING centerlines. No Do not display Pro/PIPING centerlines. yes, no 7 0.5 256

Category

Description

Values

Default value

photorender_memory_usage

Photorender

photorender_preview_scale

Photorender

pick_aperture_radius

System

pick_chain_tangent_only

Drawing

no

pipe_3d_bend_theor_int_pts

Without category

no, yes yes, no

no no

pipe_bend_locations_csys_units

Piping

pipe_pre_22_bendinfo_conv

Piping

yes, no

yes

pipe_solid_centerline

Piping

yes, no

yes

Parametric Technology Corporation

75

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specify the pipe solid label format that will be used to automatically generate pipeline labels. Yes - Pipelines created prior to Release 20.0 are updated with intersection point entities. The entities are created in session by Info>Regen Info or when you retrieve the model. Sets the default pipeline assembly library directory. Sets the default pipeline assembly name format. Specify the pipeline label format that will be used to automatically generate pipeline labels. Sets the default pipeline solid start part name. Specify the pipeline spool label format that will be used to generate the spool labels during pipeline spool generation. Sets the default pipeline start assembly name. Sets the default piping appearance map filename. yes, no no

Category

Description

Values

Default value size,-,specification,,mnemonic,-,number,,insulation

pipe_solid_label_format

Piping

pipe_update_pre_20_int_pts

Piping

pipeline_assembly_library_dir

Piping

/devsrc1/spg/system_1 /text/piping_data/pipeli nelib/ mnemonic,-,number size,-,specification,,mnemonic,-,number,,insulation pipeline_solid_start.prt mnemonic-numberprefix[0]spoolnum [01]suffix[] pipeline_start.asm

pipeline_assembly_name_format

Piping

pipeline_label_format

Piping

pipeline_solid_start_part_name

Piping

pipeline_spool_label_format

Piping

pipeline_start_assembly_name

Piping

piping_appearance_map_file

Piping

/devsrc1/spg/system_1 /text/piping_data/maste r_catalog/piping_appe arance.map /devsrc1/spg/system_1 /text/piping_data/maste r_catalog/piping_bolt_n ut_select.ptd 76 Pro/ENGINEER Wildfire 5.0 Configuration Options

piping_bolt_nut_select_file

Piping

Piping bolts and nuts selection file.

Parametric Technology Corporation

Name Sets the current Piping design method for pipeline modeling. Enable designatable reports for specdriven piping. Sets the default piping end compatibility filename. yes, no yes non_spec_driven, spec_driven, user_driven non_spec_driven

Category

Description

Values

Default value

piping_design_method

Piping

piping_enable_designate_report

Piping

piping_end_compatibility_file

Piping

/devsrc1/spg/system_1 /text/piping_data/maste r_catalog/piping_end_c ompatibility.ptd cartesian, cylindrical, spherical cartesian 1.5 /devsrc1/spg/system_1 /text/piping_data/sampl e_project/piping_fitt_ca tegory_map.ptd /devsrc1/spg/system_1 /text/piping_data/fittingl ib/ no, yes no /devsrc1/spg/system_1 /text/piping_data/sampl e_project/piping_insula tion_dir.ptd 1 1

piping_extend_dim_scheme Sets the default piping fitting angle tolerance value. Sets the default piping fitting category map filename.

Piping

Specify a dimension scheme for piping extend segment.

piping_fitt_angle_tolerance

Piping

piping_fitt_category_map_file

Piping

piping_fitt_library_dir

Piping

Sets the default piping fitting library directory. Enables/disables the Parameters tab in Create Pipeline Dialog Sets the default piping insulation directory filename.

piping_fluid_parameter

Piping

piping_insulation_dir_file

Piping

piping_joint_fitting_clearance

Piping

Sets the piping joint minimum fitting clearance value. Sets the piping joint minimum fitting offset value.

piping_joint_fitting_offset

Piping

Parametric Technology Corporation

77

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default piping manufacture directory filename.

Category

Description

Values

Default value /devsrc1/spg/system_1 /text/piping_data/maste r_catalog/piping_manu facture_dir.ptd /devsrc1/spg/system_1 /text/piping_data/maste r_catalog/piping_mater ial.ptd /devsrc1/spg/system_1 /text/piping_data/maste r_catalog/ /devsrc1/spg/system_1 /text/piping_data/maste r_catalog/piping_mcat_ dir.ptd 1 /devsrc1/spg/system_1 /text/piping_data/sampl e_project/

piping_manufacture_dir_file

Piping

piping_material_file

Piping

Sets the default piping material filename.

piping_mcat_dir

Piping

Sets the default piping master catalog directory. Sets the default piping master catalog directory filename.

piping_mcat_dir_file

Piping

piping_min_bolting_clearance Sets the default Project data directory.

Piping

Sets the default piping minimum bolting clearance value.

piping_project_data_dir

Piping

piping_schematic_driven

Piping

Set the Schematic Driven Pipeline Modeling ON/OFF Specify directory with full path containing schematic information XML file(s). Sets the default piping specification directory filename.

no, yes

no /home/kapig/config_pr o/ /devsrc1/spg/system_1 /text/piping_data/sampl e_project/piping_spec_ dir.ptd mnemonic 1

piping_schematic_xml_dir

Piping

piping_spec_dir_file

Piping

piping_system_tree_format

Piping

Sets the default piping model tree format. Sets the default piping thumb wheel increment value. 78

piping_thumb_wheel_increment

Piping

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default piping thumb wheel ratio increment value. Always ask before converting old piping assemblies to update the network structure. Retrieves the assembled component in a specified representation. None - retrieves the representation specified in configuration option open_simplified_rep_by_default. Specifies the directory where plot files should be written. Use the full pathname to avoid problems. For example /home/users/plotfiles. Specifies the scaling factor for the DOTFONT line style in a plot. Yes - Plot files are given descriptive extensions when created. No - All plot files are simply given the extension .plt. Yes - Plot file names are appended with _(sheet number) before file extension. Yes - Enables the Plot Proceed dialog which provides a choice for delaying the printing of plot files. This is useful for large plots when using lp print commands. The lp command may not access the plot file before it is removed resulting in no output. Provides the ability to exclude empty window space when plotting the model to scale. Establishes the default plotter for making plot files. yes, no 1 none manual, never, automatic manual 0.01

Category

Description

Values

Default value

piping_thumb_wheel_ratio_inc

Piping

piping_wildfire_convert

Piping

placement_rep_by_default

File Storage & Retrieval

plot_file_dir

Printing & Plotting

plot_linestyle_scale

Printing & Plotting

plot_names

Printing & Plotting

plot_names_with_sheet

Without category

yes, no yes, no

no no

plot_proceed_dialog

Printing & Plotting

plot_to_scale_full_window

Printing & Plotting

yes, no

plotter

Printing & Plotting

Parametric Technology Corporation

79

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the command that you use to start a plot on your system; for Windows NT or Windows 95, windows_print_manager option configures Pro/ENGINEER to plot to a recognized device in the Windows NT or Windows 95 print manager. Specifies the type of plotter handshake initialization sequence generated in the plotter files. Specify font used in the Pro/ENGINEER pop-up help. Add the comma-delimited variables in any order (italic bold, 24, times or 24, times, italic bold have the same effect). Any omitted variable uses the standard setting. Specifies whether or not to compress exported shaded PostScript files. Yes - A shaded postscript file created with File>Export will be compressed. This will increase processing time. Set the default preferred deliverable for the Publish Context in Drawings. Allows customizing the order of the Type selections found under File ->Save A Copy. Yes - Selectable items beneath the pointer are highlighted prior to being selected. No - Selectable items beneath the pointer are not highlighted prior to being selected. Yes ? Selectable items in the model tree and layer tree are highlighted prior to being selected. 80 yes, no yes yes, no no hardware, software windows_print_manager

Category

Description

Values

Default value

plotter_command

Printing & Plotting

plotter_handshake

Printing & Plotting

popuphelp_font

User Interface

postscript_compression

Printing & Plotting

preferred_publish_deliverable

Drawing

print, iges, set, dxf, step, cgm, pdf, dwg, tiff, medusa, stheno

print

preferred_save_as_type

File Storage & Retrieval

prehighlight

Environment

prehighlight_tree

Environment

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - During component placement, component being assembled will retain its normal colors.No - During component placement, component being assembled is shown in preview color. Specify the default color for components added to a process assembly in a previous step. Specify the default font for previously added components in a process assembly. Specifies path to ANSYS executable. Sets the path to the catalog directory containing the catalog menu and the names of other catalog files, such as ejector pins. For example: pro_catalog_dir proe_loadpoint/apps_data/mold_data/catal og. Use full path name to avoid problems. Sets the default directory for cavity layout rules. Use the full path name to avoid problems. Sets the directory from which terminators are retrieved. Use the full pathname to avoid problems. Specifies the directory path for a color map (.map) file to be loaded from disk. Use the full path name to avoid problems. Specifies a default directory for your crosshatch library in which you can save crosshatching patterns for later retrieval. Its value is the full path name of the default directory. 0 no, yes no

Category

Description

Values

Default value

preserve_comp_color_in_preview

Assembly

prev_proc_comp_def_color

Assembly Process

prev_proc_comp_def_font

Assembly Process

pro_ansys_path

Without category

pro_catalog_dir

Casting & Mold Design

pro_cav_lay_rule_dir

Casting & Mold Design

pro_cbltrm_dir

Electromechanical

pro_colormap_path

Colors

pro_crosshatch_dir

File Storage & Retrieval

Parametric Technology Corporation

81

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the directory for the drawing setup files. If this option is not set, the system uses the default setup directory. Enables use of an editor other than the system editor when the option editor has been specified as the value for the options part_table_editor or relation_file_editor. Sets the default font directory (Pro/ENGINEER will load all fonts in this directory into the drawing regardless of the contents of the system and working directories). Sets the default directory for the drawing format library. Use the full pathname to avoid problems. Specifies the directory in which Granite application plug-ins are located. Use the full pathname to avoid problems. Sets the default directory for the userdefined feature (UDF) library. If not specified, your current working directory is the default. Use the full pathname to avoid problems. Specifies the directory to search for insulation files used in Pro/PIPING. Use full path name to avoid problems. Sets the default directory for the Pro/ENGINEER libraries (or any libraries you have built containing the proper index menu files). Use the full pathname to avoid problems.

Category

Description

Values

Default value

pro_dtl_setup_dir

Drawing

pro_editor_command

User Interface

pro_font_dir

File Storage & Retrieval

/devsrc1/spg/system_1 /text/fonts/

pro_format_dir

Drawing

pro_gplug_dir

Data Exchange

/devsrc1/spg/system_1 /sun_solaris_x64/gplug s/

pro_group_dir

Features

pro_insulation_dir

Piping

pro_library_dir

File Storage & Retrieval

Parametric Technology Corporation

82

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default directory for the part material library. Use the full pathname to avoid problems. Sets the default directory for the Machinability Database (MDB) files. Use the full pathname to avoid problems. Sets the default directory for the manufacturing CL data files.Use the full pathname to avoid problems. Specifies the directory where the manufacturing clamps can be found. Sets the default directory for the manufacturing parameter files. Use the full pathname to avoid problems. Sets the default directory for the manufacturing tool files. Use the full pathname to avoid problems. Sets the default directory for the manufacturing workcell files. Use the full pathname to avoid problems. Sets the default directory for the syntax menu files in Pro/MFG. Use the full pathname to avoid problems. Specifies the path to the MSC/NASTRAN executable (nastran). Specifies the directory from which to retrieve notes entered from a file. Use the full path name to avoid problems. Sets the default directory for drawing symbol palette files. Specifies the directory to search for fittings used in Pro/PIPING. 83

Category

Description

Values

Default value

pro_material_dir

File Storage & Retrieval

pro_mdb_dir

Manufacturing

pro_mf_cl_dir

Manufacturing

pro_mf_clamp_dir

Manufacturing

pro_mf_param_dir

Manufacturing

pro_mf_tprm_dir

Manufacturing

pro_mf_workcell_dir

Manufacturing

pro_mfg_cmdsyn_dir

Manufacturing

pro_nastran_path

Without category

pro_note_dir

Drawing

/home/kapig/config_pr o/ /devsrc1/spg/system_1 /symbols/palette/

pro_palette_dir

Drawing

pro_pip_fitt_dir

Piping

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the directory to search for linestock files used in Pro/PIPING. Use full path name to avoid problems. Sets the directory of your user-defined plotter configuration file. Use the full pathname to avoid problems. Sets the default directory of your userdefined bend tables. If not set, the Pro/SHEETMETAL supplied bend tables are used. Use the full path name to avoid problems. Specifies the directory to save/retrieve Sheet metal parameters files.Use full path name to avoid problems. Specifies the name of the user-defined solver to be included in the SOLVE menu. See also pro_solver_path. Specifies the path to the user-defined solver whose name is defined in the SOLVE menu. See also pro_solver_name Sets the directory from which spools are retrieved. Use the full pathname to avoid problems. Specifies the command for Stheno launch. Sets the default directory for your userdefined surface finish symbols. Use the full pathname to avoid problems. Set and automatically create the default directory for saving and retrieving userdefined symbols. If you do not specify a directory, the system uses the current working directory. Use full path name to avoid problems. 84

Category

Description

Values

Default value

pro_pip_lnstk_dir

Piping

pro_plot_config_dir

Printing & Plotting

pro_sheet_met_dir

Sheetmetal

pro_smt_params_dir

Sheetmetal

pro_solver_name

Without category

pro_solver_path

Without category

pro_spool_dir

Electromechanical

/home/kapig/config_pr o/

pro_stheno_command

Data Exchange

pro_surface_finish_dir

File Storage & Retrieval

/devsrc1/spg/system_1 /symbols/surffins/ /home/kapig/config_pr o/

pro_symbol_dir

Drawing

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Allows the user to specify a different graphics library. Sets the default units for new objects. Sets the default units for mass for new objects. Specifies the default system of units for new models. Specifies the directory to search when a weld parameter file is needed. Specify the name of the Pro/Develop registry file. Specify the size in megabytes of the memory buffer to be reserved by Pro/ENGINEER for system out of memory condition. You must restart Pro/ENGINEER for the change to take effect. Affects CL-Data output for profile milling sequences. Yes - Sequence parameter output_point is available with options: tip Toolpath is output with respect to the tool center; on_profile - Toolpath is output with respect to the profile of the tool. Specifies whether or not to display a prompt allowing you to save your undisplayed objects. This option is used in conjunction with the Erase > Not Displayed command on the File menu. yes, no 50 mks, cgs, mmns, fps, ips, proe_def, mmks unit_ounce, unit_pound, unit_ton, unit_gram, unit_kilogram, unit_tonne unit_inch, unit_foot, unit_mm, unit_cm, unit_m unit_inch unit_pound

Category

Description

Values

Default value

pro_texture_library

Photorender

pro_unit_length

Environment

pro_unit_mass

Environment

pro_unit_sys

Environment

pro_weld_params_dir

Weld

prodevdat

Application Programming Interfaces

proe_memory_buffer_size

Environment

profile_output_utils

Manufacturing

no

prompt_on_erase_not_disp

File Storage & Retrieval

yes, no

no

Parametric Technology Corporation

85

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines if you are prompted to save objects when exiting a Pro/ENGINEER session. Enter directory path to NCPost database file. When saving objects with option save_objects set to Changed or Changed_and_specified, Pro/ENGINEER verifies which models are. Yes - Any model that is a parent of a changed model is considered to be a changed model when determining what to save. Yes - causes the propagation of inactive annotation. Enables toolpath computation on a separate host machine. Required values are Processor name, Remote machine's hostname, Type of transport (always 0), RPC processor number (same as that of remote processor), Version of queue manager. Yes - Starts Pro/TABLE editor in the background. Reduces time between pressing a menu button that uses Pro/TABLE and entering the data. Specify the Pro/TOOLKIT registry file. no, yes yes no, yes yes, no no yes, no no

Category

Description

Values

Default value

prompt_on_exit

User Interface

proncpost_dbf

Manufacturing

propagate_change_to_parents

File Storage & Retrieval

propagate_inactive_annotation

User Interface

yes

prorembatch_queue_manager

Manufacturing

protable_in_background

System

protkdat

Application Programming Interfaces

provide_pick_message_always

User Interface

No - A message describing the (pre)selected item is provided only while querying. Yes - A message describing the selected item is provided in all cases (i.e. even when Query is not used). 86

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies whether or not to include pagesize information when generating postscript files from Pro/ENGINEER. No Pro/ENGINEER will omit Adobe level 2 pagesize information from the header of the postscript file. Enter directory path to NCPost database file. Yes - Enables the creation of punch axis points in Sheetmetal cuts and punches. Sets path to directory that contains the punch models. Specifies whether or not to suppress the output of the IGES drawing entity, #404, to the IGES file. No - The drawing entity is not output. Sets the warning style when quantity balloons have changed in a drawing.Dialog displays the warning in a dialog box, Message displays the warning in the message area only. Specify the path and name of a drawing template to be used by the File > Quick Print command. Specify the path and name of the default plotter config file to be used by the File > Quick Print command. YES - Option for creation of radial hole with a linear dimension will be available. Determines the resolution for plotter outputs variables are in dots per inch. Modify grid space in percentage units for handle movement. 87 yes, no 100, 200, 300, 400 no 100 0.05 yes, no yes yes, no no yes, no yes

Category

Description

Values

Default value

ps_output_with_pagesize

Printing & Plotting

ptncpost_dbf

Manufacturing

punch_axis_points

Sheetmetal

punch_models_directory

Sheetmetal

put_iges_drawing_entity

Data Exchange

qty_balloon_change_warning

Without category

dialog, message

dialog

quick_print_drawing_template

Without category

quick_print_plotter_config_file

Without category

radial_hole_linear_dim

Without category

raster_plot_dpi

Printing & Plotting

ratio_grid_interval

Features

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name No - Ignores filename.ptd. Yes - Creates and saves filename.ptd and uses that file when retrieving the generic. Allow Pro/ENGINEER designated parameters on excluded objects in Simplified Representation to be visible in Model Tree columns. Disable realtime rendering. Indicates whether to recompute associative dimensions upon import of an IGES file. Set the color of backed up references according to RGB values. Enter RGB values between 0 and 100 separated by space. Enable changing colors of backuped references during selection. Disable selecting references backuped by references control. Disable selecting references prohibited by references control. Set the color of prohibited references according to RGB values. Enter RGB values between 0 and 100 separated by space. Enable changing colors of prohibited references during selection. no, yes no, yes no, yes no, yes yes, no disable, transparent_floor, room_display disable no yes, no no no, yes no

Category

Description

Values

Default value

read_famtab_file_on_retrieve

File Storage & Retrieval

read_parameters_of_excluded

Data Management

real_time_rendering_display

Model Display

recompute_iges_dim_value

Data Exchange

ref_scope_copy_color

Without category

55

ref_scope_copy_color_change

Without category

yes no yes 45

ref_scope_no_pick_to_copy

Without category

ref_scope_no_pick_to_prohibit

Without category

ref_scope_prohibit_color

Without category

ref_scope_prohibit_color_change

Without category

yes

Parametric Technology Corporation

88

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the directory in which the system stores regen_backup models. (See regen_backup_using_disk.) The primary default is the current directory, but if that directory is read-only, the secondary default is the /tmp directory. Specifies whether or not the system backs up the current model to disk before each regeneration. Specifies whether to enter resolve mode when regeneration failures occur.Resolve_mode - Enter resolve mode when regeneration failures occur. No_resolve_mode - Don't enter resolve mode when regeneration failures occur. Ask_user - Let the user decide whether to enter resolve mode or not when regeneration failures occur. Yes to regen models intersected with assem feats during assembly retrieval. Specifies whether or not the layout will be automatically regenerated upon assembly regeneration. Regenerate the assembly when retrieving an assembly simplified representation. Yes - Regenerates the assembly on retreival.No - The assembly is not regenerated on retrieval. Determines whether an object retrieved from PDM database with read only status can be regenerated in a Pro/ENGINEER session. Sets the editor used to edit relations. 89 yes, no yes, no resolve_mode, no_resolve_mode yes, no no

Category

Description

Values

Default value

regen_backup_directory

Environment

regen_backup_using_disk

Environment

regen_failure_handling

Without category

no_resolve_mode

regen_int_mdls_on_retr

Without category

no yes

regen_layout_w_assem

Assembly

regen_simp_retrieve

File Storage & Retrieval

yes, no

no

regenerate_read_only_objects

Data Management

yes, no

yes

relation_file_editor

User Interface

protab, editor

editor Pro/ENGINEER Wildfire 5.0 Configuration Options

Parametric Technology Corporation

Name No - Disable trail output from Text layout in Relation Parameter UI if it hasn't been changed. Will control how mapkeys will be executed in relation tool / dialog.Incremental will add/remove text incrementally to the current set.Full_output will record the original set state and replace the current one with it. Note: this config is dependent on relation_text_trail_output. Specifies whether diagnostic should be issued when an unitless numeric value causes relation expression evaluation trouble. Set the default unit sensitivity (ignore or take into account parameter/dimensions units) in creation of new relation data (legacy relation data will not be unit sensitive until "converted" to one). Yes - Sets the default of the ATTACH TYPE menu of the last options picked. Yes - Sets the default of the GET POINT menu as the last option picked among Pick Pnt, Vertex and On Entity. Controls whether the system copies associated drawings automatically with parts and assemblies. Sets the naming convention used when replacing components. yes, no yes, no yes, no yes, no no increment, full_output increment yes, no yes

Category

Description

Values

Default value

relation_text_trail_output

Miscellaneous

relation_tool_mapkey_behavior

Miscellaneous

relations_num_const_units

Without category

relations_units_sensitive

Without category

yes

remember_last_attach_type

Without category

yes no

remember_last_get_point_option

Drawing

rename_drawings_with_object

File Storage & Retrieval

none, part, assem, both

none

replace_comp_name_method

Assembly

transfer, remove, preserve

transfer

Parametric Technology Corporation

90

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specify treatment of notes when components are replaced. Transfer transfer to new component. Remove remove the notes. Preserve - save notes in case component is restored. Set the default order of the history evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. Set the default order of the interface evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. Set the default order of the same id evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. Set the default order of the same name evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. Set the default order of the same parameters evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. 91 disable, 1, 2, 3, 4, 5 1 disable, 1, 2, 3, 4, 5 3 transfer, remove, preserve transfer

Category

Description

Values

Default value

replace_comp_notes_method

Without category

replace_history_rule_order

Assembly

replace_interface_rule_order

Assembly

replace_sameid_rule_order

Assembly

disable, 1, 2, 3, 4, 5

replace_samename_rule_order

Assembly

disable, 1, 2, 3, 4, 5

replace_sameparam_rule_order

Assembly

disable, 1, 2, 3, 4, 5

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Availability of automatic reference pairing in unrelated replace. No - Automatic reference pairing is not available. Yes Automatic reference pairing is available. Setup whether the terminal splices of cables are reported. Reserves space for extra menus to the right of the Pro/ENGINEER window (0.04.0). This option overrides windows_scale. Determines whether the Geometric Tolerance dialog restricts the user by graying out elements that are considered "illegal". Specify name and path of the file contained restricted values definition. Determines if the display of an object currently on the screen is kept in memory when you quit the window. Doing so (yes) makes the retrieval of objects in memory faster. Automatic reference parts retrieval for dependent data sharing features. Controls whether or not graphics data is loaded in the background. Determines whether to retrieve the dependencies of the generic when an instance is retrieved. Automatic reference parts retrieval for dependent Merge. If the option value is 1, the tool path is obtained from standard one by reversing it; if the option value is 2, the tool path starts from an inner circle. 92 yes, no yes yes, no 1 yes, no no yes, no no

Category

Description

Values

Default value

replace_unrelated_automatic

Assembly

report_end_splice

Electromechanical

reserved_menu_space

User Interface

restricted_gtol_dialog

Dimensions & Tolerances

yes

restricted_val_definition

Without category

retain_display_memory

File Storage & Retrieval

retrieve_data_sharing_ref_parts

File Storage & Retrieval

yes, no, ignore_missing background foreground instance_deps_only, instance_and_generic_deps, instance_req_generic yes, no, ignore_missing

no background instance_req_generic

retrieve_display

Without category

retrieve_instance_dependencies

Assembly

retrieve_merge_ref_parts

Without category

no

reverse_spiral_finish_type

Without category

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Flat ribbon cables in the y-axis of entry ports. Specify whether or not the right mouse button pop up menu is available or not. yes, no yes y_axis, x_axis y_axis

Category

Description

Values

Default value

ribbon_cable_flat_direction

Electromechanical

right_mouse_button_popup

User Interface

room_rotation_lock

Photorender

Default room rotation setting at session start.studio - Lock room rotation to studio.model - Lock room rotation to model. Specifies rotation for printing. Yes Rotates a PostScript plot 90 degrees counterclockwise. Use when you are plotting a landscape drawing on a portraittype laser printer, or a portrait drawing on a landscape-type laser printer. No - newly created or first shown dimension is displayed with all its significant decimals."Rounded Dimension Value" Check Box will be unchecked while opening Dimension Properties Dialog. Yes - number of decimals is rounded according to default dec places option."Rounded Dimension Value" Check Box will be checked while openingDimension Properties Dialog. Will control default option when setting a model or component as the current object. Sets the search scope for children when entering the reference viewer. Session Search all objects in session. Window Search objects in the active window only. yes, no yes, no

studio, model

studio

rotate_postscript_print

Printing & Plotting

round_displayed_dim_values

Dimensions & Tolerances

yes

rv_current_object

Assembly

component, model, component + model session, window

component session

rv_search_scope

Assembly

Parametric Technology Corporation

93

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name When performing a save on a model, determines what level of the assembly will have bitmap images created of modified components. When performing a save on a model, determines the type of image file that is created for that model. Used with "save_bitmap" option. Yes - clipping status is saved with model. No - clipping status is not saved. Controls whether the Save dialog is shown for models whose storage location is already known. Yes - Stores view geometry and detail items such as solid dimensions. These items are displayed when retrieving the drawing in View-Only mode. If set to no, the top level assembly will store sub model layer display status, allowing lower level display status to be stored without having to save the sub models. Embed - Embeds a picture file inside a drawing for preview purposes. Export Saves a drawing file as a picture file in the working directory when saving a drawing. Both - Does both embed and export. The items on the "Hidden Items" temporary layer are stored permanently when layer display status is saved with Save Status command. yes, no no, yes yes, no yes, no no yes bmp, tiff, gif, cgm, jpeg bmp none, toplevelonly, alllevels none

Category

Description

Values

Default value

save_bitmap

Data Management

save_bitmap_type

Data Management

save_clipped_view

File Storage & Retrieval

save_dialog_for_existing_models

File Storage & Retrieval

save_display

Drawing

no

save_display_status_in_submodel

Layers

yes

save_drawing_picture_file

Drawing

no, export, embed, both

embed

save_hidden_items_w_status

Without category

yes, no

yes

Parametric Technology Corporation

94

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name With family tables of solid parts, determines saving instance accelerators. None - Accelerator files not used. Explicit Save when instance is explicitly saved. Saved objects - Save when objects were modified. Always - Always save. Sets amount of graphical data stored. Wireframe - Wireframe data. Shading_high - Most detail (shaded). Shading_low Least detail (shaded). Shading_lod - Detail determined by ViewPerformance dialog (shaded). Determines whether the system saves the model after you have changed it. No Saves the model every time that you store the drawing. Use with the override_store_back option. Yes - Objects retrieved from a directory where you do not have write permission will be stored in the current directory. No These objects are not saved at all. Determines when an object and its dependent objects (such as a part used in an assembly) are stored. Yes - Automatically update the model with current scene information when saving the model; No - Scene information embedded in model must be updated manually. Yes - Embed applied texture and tracesketch bitmap files into the model file. Spinning shaded images with software graphics only.Note: This option has no effect if your system uses hardware graphics. 95 yes, no no, yes shading_lod wireframe shading_low shading_high shading_lod none, explicit, always, saved_objects saved_objects

Category

Description

Values

Default value

save_instance_accelerator

File Storage & Retrieval

save_model_display

File Storage & Retrieval

save_modified_draw_models_only

Drawing

yes

save_object_in_current

File Storage & Retrieval

no

save_objects

File Storage & Retrieval

all, changed, changed_and_specified, changed_and_updated yes, no

changed_and_specifie d no

save_scene_with_file

Photorender

save_texture_with_model

Photorender

yes, no no, yes

no no

save_triangles_flag

Model Display

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines how to save in the current working directory an object fetched from a Pro/PDM database into a Pro/ENGINEER session. Yes - Enables Pro/ENGINEER popup helptext and menus to retain the portion of the window they obscure to be used to restore the window image when they are dismissed. Prohibit - System will abort all attempts to create external reference violating the scope. Backup - Warning appears. Abort reference creation or declare as out-ofscope reference. If you declare, backup copies to part/assembly and backup is referenced. Expands search to include models that have not been retrieved into session. If Yes, models will be brought into session possibly causing performance issues. Specifies list of directories to search (in order) for object/file retrieval. These directories, the working directory, and directories in search.pro file (refer to search_path_file) are Pro/ENGINEER's search path. Use full path name to avoid problems. Specifies path to text file search.pro (a list of directory path names). The directories listed in search.pro, the working directory, and directories specified by search_path are Pro/ENGINEER's search path. Use full path name to avoid problems. yes, no copy, prohibit copy yes, no yes as_ref, as_copy as_ref

Category

Description

Values

Default value

save_unchanged_pdm_object

Data Management

saveunders_enabled

System

scope_invalid_refs

Without category

search_not_retrieved_models

Assembly

yes

search_path

File Storage & Retrieval

search_path_file

File Storage & Retrieval

Parametric Technology Corporation

96

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the color of sketched sections. Yes - If the components used in the assembly instances are themselves generics, the systems asks if you want to choose an instance as each component is retrieved. No - The generic model of the component is retrieved automatically. Controls selectability of hidden edges in no-hidden drawing views. All_modes - Select a datum plane by clicking on its visual boundary. Sketcher_only - Select a datum plane by clicking on its tag in modes other than Sketcher. If you use Query frequently, set this option to Sketcher_only. Yes - Entities in front of cross-section (planar or offset) can be selected, clipped (using Z-clipping), or erased with EDGE DISP menu. No - Geometry, datum points or curves, cosmetic features, threads, grooves, or coordinate systems cannot be erased. Determines width of menu manager panels. Default value is equivalent to 8 character widths. Acceptable range is from 8 to 20. Values lower than 8 and higher than 20 are ignored. Determines which model types are used in the Save Changed command. The format is a list of extensions separated by spaces. Yes - Enables a trail file to be singlestepped by entering . 97 yes, no yes, no all_modes, sketcher_only yes, no yes all_modes yes, no no default, sketch_color, drawing_color

Category

Description

Values

Default value

section_color

Sketcher

sel_insts_on_comp_retrieval

Assembly

select_hidden_edges_in_dwg

Drawing

select_on_dtm_edges

Environment

selection_of_removed_entities

Drawing

no

set_menu_width

User Interface

-1

set_model_types_to_save

File Storage & Retrieval

asm

set_trail_single_step

System

no Pro/ENGINEER Wildfire 5.0 Configuration Options

Parametric Technology Corporation

Name No - Does not process reference parts when generating the shaded image (to save time). Yes - Shades reference parts when generating shaded images. Yes - Shades assembly components while they are being moved. No - Displays components in wireframe while they are being moved. Controls the shading of surface features. Enables shading of objects in all windows. This option does not also enable color shading. Controls the display of datum curves on shaded objects. Specifies how background colors are handled in Postscript files of shaded objects. Sets all mold layout buttons visible. Default value for annotations dialog Determines if axes are created for newly extruded arcs. Allows the printing of the transformation matrix of a Pro/Verify Fit into a file. Yes - show a column for Description field for all tabs in view manager. yes, no yes, no yes, no no no no yes, no curves, no all_windows, one_window yes, no yes all_windows yes, no yes no, yes yes

Category

Description

Values

Default value

shade_mfg_ref_models

Manufacturing

shade_moving_comp

Model Display

shade_surface_feat

Model Display

shade_windows

Model Display

shade_with

Model Display

curves

shaded_postscript_background

Printing & Plotting

no

show_all_mold_layout_buttons

Casting & Mold Design

yes, no

no

show_annotations_dialog_limit

Drawing

show_axes_for_extr_arcs

Model Display

show_cav_fit_loc_sys

Miscellaneous

show_description_view_mgr

Without category

Parametric Technology Corporation

98

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name No - Dimension values always appear positive. Negative value creates geometry to opposite side. Yes - Entering negative value for dim displayed as negative creates geometry to same side. Dims for csys and datum point offsets always show neg/pos value. Yes - The SHOW ERRORS menu appears at the end of feature creation when the feature being created has Geometry Checks. This option determines the default behavior for preview in Show/Erase. Show id of Pro/E and Sketcher geometry in query selection bin, collector and tool tip. Controls the edge color when shading. Yes - Edges are displayed in darker color than the surfaces to which they belong. No - Edges are displayed in the same color as the surfaces to which they belong. Determines how dimensions are displayed when shrinkage is applied to a model with Pro/MOLDESIGN. Percent_shrink Dimensions appear with the shrinkage percent. Displays the Shrinkwrap alert the first time the quality level is increased. Allows creation of Shrinkwraps from problematic geometry. Downstream referencing of Shrinkwrap geometry could cause issues asShrinkwrap may contain "Geometry checks". 99 no, yes no, yes keep, remove yes, no no yes, no no

Category

Description

Values

Default value

show_dim_sign

Environment

show_geom_checks_on_creation

Features

show_preview_default

Drawing

remove no

show_selected_item_id

Environment

show_shaded_edges

Model Display

no

shrinkage_value_display

Casting & Mold Design

final_value, percent_shrink

percent_shrink

shrinkwrap_alert

Assembly

yes, no yes, no

yes no

shrinkwrap_skip_geom_validation

Without category

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Treats Mass Idealizations as additive if they are applied to the same entity and suppresses Mass precedence rules. Sets the default value for the ratio of Edge Length / Radius of curvature. Sets the value for the target ratio of Edge Length / Radius of curvaturefor automatic creation of a global AutoGEM Control. Set the value to the part thickness. This causes AutoGEM to perform more boundary refinement, and can be very useful for thinner parts. Sets the default maximum angle tolerance for auto-mapping of pressure load. The valid range is from 0 to 90 degrees. Sets the default maximum distance tolerance (relative to model size) for automapping of pressure load. The default value is 0.0012. Set the value of characteristic thickness for auto-detection of shell pairs. Using this as a threshold value, auto-detection will find surface pairs with thickness smaller than this value. Yes - Regenerate model on entrance to Mechanica. No - Don't regenerate the model. Specifies the path where the Beam Sections will be stored. Enables node reaction calculations for point constraints within links. The default value is NO. yes, no no yes, no 0 2 yes, no no

Category

Description

Values

Default value

sim_additive_mass

Without category

sim_agem_edge_by_crv_default

Without category

sim_agem_edge_crv

Without category

sim_agem_model_thickness

Without category

-1

sim_auto_map_max_angle

Without category

10

sim_auto_map_max_dist

Without category

0.0012

sim_auto_pairing_thickness

Without category

sim_auto_regen_enabled

Without category

yes

sim_beamsection_path

Without category

sim_calculate_node_reaction

Without category

Parametric Technology Corporation

100

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name No - Suppress Jacobian checks at corner nodes (default). ANSYS and Nastran will check parabolic elements Jacobian at the integration points only and FEM will fix too curved elements for the same criterion. Yes - Jacobian is checked both at integration points and corner nodes. FEM mode will fix too curved elements accordingly. Toggles display of AutoGEM Controls. Toggles automatic arrow scaling. Toggles display of Load arrows to have tails or heads touching. Toggles display of Beam Release icons. Toggles display of beam section icons. Toggles display of beam icons. Toggles display of contact icons. Toggles display of the current coordinate system triad in the lower right corner of the window. Toggles display of Fastener icons. If set to yes, selecting a load/constraint will highlight its geometrical references. Toggles display of simulation objects in Dynamic Spin. Toggles display of structure connection icons. Specifies whether internal edges of mesh elements should be displayed in the wireframe mode. The default is "No". Toggles display of Load colors. 101 no, yes no, yes yes, no yes, no yes, no yes, no yes, no yes, no yes, no no

Category

Description

Values

Default value

sim_check_jacobian_corners

Without category

sim_display_agem_controls

Without category

sim_display_arrow_scale

Without category

sim_display_arrow_tail_touching

Without category

sim_display_beam_releases

Without category

sim_display_beam_sections

Without category

sim_display_beams

Without category

sim_display_contacts

Without category

sim_display_current_csys_triad

Without category

sim_display_fasteners

Without category

yes, no yes, no yes, no no, yes yes, no no

sim_display_highlight_refs

Without category

sim_display_in_spin

Without category

sim_display_interfaces

Without category

sim_display_internal_mesh_edges

Without category

sim_display_load_colors

Without category

yes, no Pro/ENGINEER Wildfire 5.0 Configuration Options

Parametric Technology Corporation

Name Toggles display of distributed load vectors over entire entity. Toggles display of load icons. If set to yes, the load/constraint name is displayed in the label. Toggles display of Load values. Toggles display of loads and constraints defined on lower-level components of assembly. Toggles display of mass icons. Toggles display of Material Assignment icons. Toggles display of Simulation Measure icons. Toggles display of Mesh together with Model. If set to yes, the Mesh/AutoGEM control name is displayed in the label. If set to yes, the Mesh/AutoGEM control value is displayed in the label. Toggles display of Mesh Controls. Toggles display of Mesh entities. Specifies the mode of mesh display in FEM preprocessor. Values: NO_MESH, WIREFRAME, HIDDEN, NOHIDDEN, SHADING. Specifies the quality of mesh display in Mechanica. Values: FINE, MEDIUM, COARSE. yes, no yes, no yes, no yes, no yes, no no_mesh, wireframe, hidden, nohidden, shading yes, no yes, no no, yes yes, no yes, no yes, no yes, no yes, no

Category

Description

Values

Default value

sim_display_load_distribution

Without category

sim_display_load_icons

Without category

sim_display_load_name

Without category

sim_display_load_value

Without category

sim_display_loads_from_comps

Without category

sim_display_masses

Without category

sim_display_matl_assignments

Without category

sim_display_measures

Without category

sim_display_mesh_and_model

Without category

sim_display_mesh_control_name

Without category

sim_display_mesh_control_value

Without category

sim_display_mesh_controls

Without category

sim_display_mesh_entities

Without category

sim_display_mesh_mode

Without category

sim_display_mesh_quality

Without category

fine, medium, coarse

Parametric Technology Corporation

102

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Toggles the display of shell thickness in Mechanica mesh. YES - Display shells with real thickness. NO - Display shells with zero thickness. Controls display of Mesh through a specified percentage of shrinking of its elements. Toggles the display of the Simulation model setup in the lower left corner of Pro/E screen. Toggles display of Simulation Object names. Toggles display of Rigid Link DOF icons. Toggles display of Rigid Link icons. Toggles display of shells pairs. Toggles display of shell icons. Toggles display of spring icons. Toggles display of structure constraint icons. Toggles display of structure load icons. Toggles display of Thermal Boundary Condition icons. Toggles display of thermal load icons. Toggles display of Weighted Link DOF icons. Toggles display of Weighted Link icons. Toggles display of Weld icons. Toggles z-buffered display of Mechanica icons. no, yes no, yes no, yes yes, no yes, no yes, no yes, no yes, no yes, no yes, no yes, no yes, no yes, no yes, no yes, no yes -1 no, yes

Category

Description

Values

Default value

sim_display_mesh_shells_thick

Without category

sim_display_mesh_shrink_elems

Without category

sim_display_model_type

Without category

sim_display_names

Without category

sim_display_rigid_dof

Without category

sim_display_rigid_links

Without category

sim_display_shell_pairs

Without category

sim_display_shells

Without category

sim_display_springs

Without category

sim_display_struct_constraints

Without category

sim_display_struct_loads

Without category

sim_display_therm_bcs

Without category

sim_display_therm_loads

Without category

sim_display_weighted_dof

Without category

sim_display_weighted_links

Without category

sim_display_welds

Without category

sim_display_z_buffered

Without category

Parametric Technology Corporation

103

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Mechanica will perform an expanded set of diagnostic checks during meshing a model or running an analysis. These include checks for interferences in an assembly and for singular geometry. No Mechanica will not perform expanded checks. Controls the maximum angle between a surface to be extended during shell compression and its adjacent surfaces. If the angle is higher than specified, the adjacent surfaces will be extended. The default is 30 degrees. The range is from 0 to 90 degrees. Controls the use of biaxiality correction. The default value is YES. Controls which method is used to model biaxiality: Klann-Tipton-Cordes, HoffmanSeeger, or the most conservative (worst) of the two methods. The default value is WORST. Specifies the percentage confidence in the predicted life result value. The default value is 90, and range is from 0.1 to 99.9 Controls the use of external material data. The default value is NO. Specifies the gate applied to cycle counting as a percentage of peak load. The default value is 1 and range is from 0 to 50. Specifies the value for the lives beyond cutoff. The default value is 1e20 and range is from 1e15 to 1e30. 104 no, yes yes, no worst, ktc, hs 30 yes, no no

Category

Description

Values

Default value

sim_expanded_diagnostics

Without category

sim_extend_surf_max_angle

Without category

sim_fatigue_biaxiality_correct

Without category

yes worst

sim_fatigue_biaxiality_method

Without category

sim_fatigue_confidence_level

Without category

90

sim_fatigue_external_matdata

Without category

no 1

sim_fatigue_hysteresis_gate

Without category

sim_fatigue_infinite_life_value

Without category

1E+20

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls the application of the mean stress correction. The default value is YES. Controls which method is used to model mean stress: the Smith-Watson-Topper Approach, Morrow Correction, or the most conservative (worst) of the two methods. The default value is WORST. Specifies a factor used to determine the Life Confidence quantity. The default value is 3 and range is from 1.1 to 100. Specifies the directory for user files (for example, external material files). The default value is the current directory. Controls writing of surface stresses to a neutral file. The default value is NO. Yes - use PSHELL cards, No - use PCOMP cards for laminate composite shells in NASTRAN output file. Specifies the path to the Simulation post processor HTML report preferences file. Sets the default method for calculating coefficients for hyperelastic materials. If set to "normalized", normalized stresses will be used. If set to "non-normalized", non-normalized stresses will be used.) Determines how many icons are drawn for a distribution. 1 is fewer, 10 is the highest. Yes - Unpaired surfaces are ignored when meshing the model, placing you directly into the AFTER COMP menu (the CONT MESH menu is skipped). yes, no normalized, non-normalized normalized yes, no no, yes no no 3 worst, swt, morrow worst yes, no yes

Category

Description

Values

Default value

sim_fatigue_mean_stress

Without category

sim_fatigue_mean_stress_method

Without category

sim_fatigue_safety_margin

Without category

sim_fatigue_user_directory

Without category

sim_fatigue_write_surf_stress

Without category

sim_fem_nastran_use_pshell

Without category

sim_html_report_prefs_file

Without category

sim_hyperelastic_material_fit

Without category

sim_icon_distribution_density

Without category

-1 no

sim_ignore_unpaired

Without category

Parametric Technology Corporation

105

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default for the display of diagnostics during the run of an analysis in Mechanica Native mode. If set to prompt, the user is prompted to rundiagnostics every time he/she starts a run. No - The user is prompted to load the existing Mechanica mesh file from the current working directory. Yes - The mesh file, if exists, is loaded automatically and the mesh is displayed. Sets the type of load preview: vectors, fringe or mesh. Specifies the convention used for defining Poisson's ratio for anisotropic materials as being either Tsai (Column-normalized) or Jones (Row-normalized). This option affects only the labels for Poisson's ratio on the Material data form. Specify the maximum number of iterations for contact analysis. The default is 200. Specifies the maximum amount of memory in megabytes to be allocated during FEM meshing. If this option is not set, or set to zero, the mesher can use all available memory. Add PARAM,COUPMASS,1 in the Nastran deck file to enforce consistent mass matrix generation. Outputs FEM mesh element IDs on each layer into XML file. Output Beam Sections names, Analyses names, Coordinate Systems names as comments. 106 yes, no no tsai, jones vectors, fringe, mesh no, yes no yes, no, prompt prompt

Category

Description

Values

Default value

sim_invoke_diagnostics_on_run

Without category

sim_load_mech_mesh

Without category

sim_loadpreview

Without category

fringe tsai

sim_mat_poissons_notation

Without category

sim_max_contact_iterations

Without category

200

sim_max_memory_usage

Without category

sim_nastran_use_coupmass

Without category

sim_output_ids_for_layers

Without category

yes, no yes, no

no no

sim_output_obj_names

Without category

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the background color of the work area for the results display. The default value is PROE. Sets the thickness for beams and 2Dshells display in Post Processor. Numerical values specify the thickness in pixels. Sets the default for the behavior of mouse spinning the model in results. Enable legacy selection of geometrical entities from Mechanica postprocessor on Mechanica geometry. Determines if the legend will be continuous tone (YES) or discrete colors (NO). The default number of legend levels (from 1 to 16; the default is 9). If set to NO, the legend is not displayed in newly created results windows by default. If set to NO, the gray minimum and maximum values are not displayed by default in the legend. This string sets the default color legend used in the definition of a results window. This file will be looked up in the sim_pp_template_dir location, or, if this is not specified, in the current working directory. Choose Absolute (Yes) or Relative (No) path to "rwd" file. Sets the default value for the display of the WCS location in dynamic query in results. 107 yes, no yes, no no no yes, no yes, no yes, no no, yes yes, no yes no actual, 1, 2, 3, 4, 5 5 proe, blue, black, white proe

Category

Description

Values

Default value

sim_pp_background_color

Without category

sim_pp_display_beam_thickness

Without category

sim_pp_display_spin_center

Without category

sim_pp_legacy_selection

Without category

sim_pp_legend_continuous

Without category

no

sim_pp_legend_levels

Without category

9 yes yes

sim_pp_legend_show

Without category

sim_pp_legend_show_min_max

Without category

sim_pp_legend_spectrum

Without category

sim_pp_path_absolute

Without category

sim_pp_query_location

Without category

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default directory for results template files. To draw 2D arrows instead of 3D arrows while post-processing vector results. It is useful when system memory is not sufficient to display3D vector arrows. Flags to denote VRML1.0 or VRML2.0 (default) output. Flag to enable the inclusion of feature edges in the VRML file. The default value is NO. Sets the default value for reentrant geometry detection in both Isolation for Exclusion AutoGEM Control and expanded diagnostics checks. The valid range is from 0 to 180 degrees. The default is 120 degrees. Yes - The system ignores unopposed surfaces when meshing the model; the system also deselects the UseUnopposed option. No - the system uses the unopposed surfaces in the shell model. Controls whether the FEM neutral file (with extension .fnf) is copied into the study directory. The default value is YES. Controls the number of CPUs that Mechanica Native mode will use for running the analysis. The possible values are: ALL (default), ALL_BUT_1, ALL_BUT_2, 2, 1, HALF. Specifies the directory for Mechanica run output storage. By default, the current directory is used. 108 yes, no no, yes vrml2.0, vrml1.0 vrml2.0 no yes, no no

Category

Description

Values

Default value

sim_pp_template_dir

Without category

sim_pp_vector_plot_arrow_2d

Without category

sim_pp_vrml_export_format

Without category

sim_pp_vrml_feature_edges

Without category

sim_reentrant_geom_angle

Without category

120

sim_remove_unopposed

Without category

no

sim_run_copy_fem_neutral_file

Without category

yes, no

yes

sim_run_num_threads

Without category

all, all_but_1, all_but_2, 2, 1, half

all

sim_run_out_dir

Without category

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specifies the directory for Mechanica run temporary storage. By default, the current directory is used. Sets the element aspect ratio criterion for the mesh smoothing process. Sets the element edge angle criterion (Quad elements only), measured in degrees, for the mesh smoothing process. Sets the element skew angle criterion (Quad elements only), measured in degrees, for the mesh smoothing process. Sets the element taper criterion (Quad elements only) for the mesh smoothing process. Sets the element warp angle criterion (Quad elements only), measured in degrees, for the mesh smoothing process. Specifies the amount of memory in megabytes reserved for solving equations and for storing element data created by the iterative solver. The default value is 128. If set to YES (default), the elements that touch the end of the spot weld are created in a circle the same diameter as the weld (AutoGEM only). Sets the default for the interfaces created between the geometry in a structural model for meshing and running analysis. Sets the default for the interfaces created between the geometry in a thermal model for meshing and running analysis. yes, no 30 7

Category

Description

Values

Default value

sim_run_tmp_dir

Without category

sim_smooth_aspect_ratio

Without category

sim_smooth_edge_angle

Without category

sim_smooth_skew

Without category

45

sim_smooth_taper

Without category

0.5

sim_smooth_warp_angle

Without category

10

sim_solver_memory_allocation

Without category

128

sim_spotweld_split_mesh

Without category

yes

sim_struct_interface_default

Without category

bonded, free, contact

sim_therm_interface_default

Without category

bonded, adiabatic, resistance

Parametric Technology Corporation

109

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Allows layers to become groups for Mechanica Independent mode. Determines the default model status while defining a new simplified rep. Enables retrieving on-demand the Master rep ofan activated model. When an assembly is activatedthe Assembly only rep is retrieved. Determines if a model retrieved on demandshould be removed or erased.Disabled - the model will not be removedand will remain in the assembly.Removed - the model will be removed. Remove_Erase - The model will be removedand erased from memory. Enables on demand retrieval of an edited item and its parent references.Configuration tools (Family Tables, Relations, etc) will retrieverequired models accordingly.Automatic - Retrieves the minimum rep required to perform the operation. Enables on demand retrieval of requiredmodels during regeneration.Can affect regeneration performance. Determines the rep to be retrieved when selecting a reference. AutomaticRetrieves the minimum rep required to perform the operation. disable, remove, remove_and_erase yes, no yes exclude, master, graphics, geometry exclude no, yes no

Category

Description

Values

Default value

sim_use_layers

Without category

simprep_default_model_status

Assembly

simprep_ondemand_activation

Without category

simprep_ondemand_cleanup

Without category

remove

simprep_ondemand_editing

Without category

disable, master, automatic, master_with_ancestors

automatic

simprep_ondemand_regeneration

Without category

automatic, master, disable

automatic

simprep_ondemand_selection

Assembly

automatic, master, disable

automatic

Parametric Technology Corporation

110

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines on-demand retrieval behavior in simplified representation views. Prompt - Ask for confirmation before retrieving ondemand. Never_prompt - Retrieve models on-demand automatically with no confirmation. Disabled - on demand is disabled. Yes - Activates FEM mode. No - Allows access to Mechanica only. Prompt (default) - Brings Mechanica Model Type Dialog. This option is used only if information about FEM mode is not yet stored with model. If set to yes the Process Guide will advance to the next set automatically upon completion of the current step. If set to yes, the Process Guide will be launched automatically upon entry into Mechanica, if template files are present. Specifies the default location of the Process Guide template files. Set Mechanica product being selected (Structure/Thermal). Prompt (default) Brings Mechanica Model Type Dialog. This option is used only if the information about Mechanica product is not yet stored with model. Specifies the color Pro/ENGINEER uses to display new skeleton models. The three decimal values ranging from 0 through 100 specify (in order) the percentages of red, green, and blue in the resulting color. For example, 0 0 49 specifies medium blue. structure, thermal, prompt prompt yes, no yes, no yes, no, prompt prompt prompt, never_prompt, disable never_prompt

Category

Description

Values

Default value

simprep_ondemand_settings

Assembly

simulation_fem_mode

Without category

simulation_process_auto_advance

Without category

no

simulation_process_prompt

Without category

no

simulation_process_template_dir

Without category

simulation_product

Without category

skeleton_model_default_color

Assembly

Parametric Technology Corporation

111

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determine if the original line style and color should be preserved on Copy/Paste, Sketcher Palette and Import from file. Yes - Preserve original line style and color. No - The section is not animated as modifications are regenerated. The option values are: 2: the system automatically creates 2 dimensioning references; 1: the system automatically adds the orientation reference as a dimensioning reference; 0: the system does not automatically create dimensioning references. This option controls whether the blended background should be used in 3D Sketcher.The option has no effect if blended background is turned off generally. Yes - collinear constraints will be used by Intent Manager; No - collinear constraints will not be used by Intent Manager. Automatically set kerning for text entities in Sketcher. Yes - Kerning will be set for new text entities. No- Kerning will not be set automatically. If this option is set all dimensions created by Intent Manager to Axis of Revolution will be diameter dimensions. Automatically lock strong sketcher dimensions. Shows the constraints when sketching in Sketcher Mode; for example, H for horizontal, V for vertical, and so on. 112 no, yes no, yes 1, 2 2 yes, no yes yes, no no

Category

Description

Values

Default value

sket_import_geometry_line_style

Sketcher

sketcher_animated_modify

Sketcher

sketcher_auto_create_refs

Sketcher

sketcher_blended_background

Sketcher

no

sketcher_collinear_constr

Sketcher

yes

sketcher_default_font_kerning

Sketcher

yes, no

no

sketcher_dim_of_revolve_axis

Sketcher

no, yes

no

sketcher_dimension_autolock

Sketcher

no, yes yes, no

no yes

sketcher_disp_constraints

Sketcher

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name No - Suppresses the display of all dimensions while in sketcher. Specify whether or not to display the sketcher grid. No - Suppresses the display of yellow points on all vertices while in sketcher. Yes - weak dimensions will be displayed; No - weak dimensions will not be displayed. Yes - equal length constraints will be used by Intent Manager; No - equal length constraints will not be used by Intent Manager. Yes - equal radii constraints will be used by Intent Manager; No - equal radii constraints will not be used by Intent Manager. Enter a grid angle value to override the default grid angle value. During import in sketcher use exact geometry. Yes - line up horizontal constraints will be used by Intent Manager; No - line up horizontal constraints will not be used by Intent Manager. Yes - line up vertical constraints will be used by Intent Manager; No - line up vertical constraints will not be used by Intent Manager. Yes - modified dimensions will be locked; No - modified dimensions will not be locked. 113 yes, no no, yes no, yes no, yes yes, no yes yes, no yes yes, no no yes, no yes

Category

Description

Values

Default value

sketcher_disp_dimensions

Sketcher

sketcher_disp_grid

Sketcher

sketcher_disp_vertices

Sketcher

sketcher_disp_weak_dimensions

Sketcher

sketcher_equal_length_constr

Sketcher

yes

sketcher_equal_radii_constr

Sketcher

yes

sketcher_grid_angle

Sketcher

0 yes yes

sketcher_import_exact_geom

Sketcher

sketcher_lineup_hor_constr

Sketcher

sketcher_lineup_ver_constr

Sketcher

no, yes

yes

sketcher_lock_modified_dims

Sketcher

yes, no

no

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - midpoint constraints will be used by Intent Manager; No - midpoint constraints will not be used by Intent Manager. Sets the default directory for the user sketcher shape library. Use the full path name to avoid problems. Yes - parallel constraints will be used by Intent Manager; No - parallel constraints will not be used by Intent Manager. Yes - perpendicular constraints will be used by Intent Manager; No perpendicular constraints will not be used by Intent Manager. Yes - point on entity constraints will be used by Intent Manager; No - point on entity constraints will not be used by Intent Manager. Refits section after dimension modification in 2D section or when creating the first feature. Enter a sketcher relative accuracy. Yes - same points constraints will be used by Intent Manager; No - same points constraints will not be used by Intent Manager. This option controls whether section files should be saved with embedded image information which can be used to preview sections in File/Open dialog. "Automatic" - grid spacing will be automatically set, "Manual" - grid spacing will be manually set. no, yes yes, no no, yes no, yes no, yes yes no, yes yes

Category

Description

Values

Default value

sketcher_midpoint_constr

Sketcher

sketcher_palette_path

Sketcher

sketcher_parallel_constr

Sketcher

sketcher_perpendicular_constr

Sketcher

yes

sketcher_point_on_entity_constr

Sketcher

yes

sketcher_refit_after_dim_modify

Sketcher

yes

sketcher_rel_accuracy

Sketcher

-1 yes

sketcher_same_point_constr

Sketcher

sketcher_save_preview_image

Sketcher

no, yes

no

sketcher_set_grid_method

Sketcher

automatic, manual

automatic

Parametric Technology Corporation

114

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Enter an x-grid spacing value to override the default x-grid spacing value. Enter a y-grid spacing value to override the default y-grid spacing value. Defines initial model orientation in Sketcher mode. Yes - (2D orientation) Looking directly at section (sketching) plane. No - (Orientation unchanged) Sketch directly on the 3D part. This option enable the user to keep a highly precise value during creation or convertion strong dimension. Yes - symmetric constraints will be used by Intent Manager; No - symmetric constraints will not be used by Intent Manager. Yes - tangent constraints will be used by Intent Manager; No - tangent constraints will not be used by Intent Manager. Controls the ability to Undo view reorientation while in Sketcher. Yes - it is possible to Undo view reorientation in Sketcher. Sketcher saves a copy of each function performed. The number of possible saved functions depend on the number specified in the option. The undo menu can be used to remove the stored functions. Gives the user the option not to display small shaded surfaces. Disabling this option will improve display quality at the expense of speed.It is most useful for creating screen snap shots. 115 no, yes no, yes no, yes yes, no yes yes, no yes 1 1

Category

Description

Values

Default value

sketcher_set_grid_x_spacing

Sketcher

sketcher_set_grid_y_spacing

Sketcher

sketcher_starts_in_2d

Sketcher

sketcher_strngthn_to_def_dec_pl

Without category

sketcher_symmetric_constr

Sketcher

yes

sketcher_tangent_constr

Sketcher

yes

sketcher_undo_reorient_view

Sketcher

no, yes

no

sketcher_undo_stack_limit

Sketcher

200

skip_small_surfaces

Model Display

yes

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Choose whether to smooth lines by default or not. Yes - Allows flipping the sketch in Flat and Flange tools. No- Disables the ability to flip the sketch in Flat and Flange tools. Define the default state of Bend Note display (sheetmetal Mode) Define the Down Direction symbol for Bend Notes (sheetmetal Mode) Define the Up Direction symbol for Bend Notes (sheetmetal Mode) Define the Fields Order for Bend Notes (sheetmetal Mode) Define the Formed symbol for Bend Notes (sheetmetal Mode) Define the Rolled symbol for Bend Notes (sheetmetal Mode) Yes - Corner relief notes will be displayed. No - Corner relief notes will not be displayed. Yes - will always fail the Sheetmetal Form feature if there is a problem with its placement . MASS - Suppressed Flat Pattern and Flatten Forms will be temporary resumed before mass properties calculation of sheetmetal part. CG - Mass Properties calculation will be performed on current state of sheetmetal part.BOTH - Both methods will be used one after the other. no, yes yes, no yes default default yes, no no no, yes no

Category

Description

Values

Default value

smooth_lines

Model Display

smt_allow_flip_sketch

Sheetmetal

smt_bend_notes_dflt_display

Sheetmetal

smt_bend_notes_direction_down

Sheetmetal

smt_bend_notes_direction_up

Sheetmetal

smt_bend_notes_order

Sheetmetal

&type&direction&angle default default yes

smt_bend_notes_type_formed

Sheetmetal

smt_bend_notes_type_rolled

Sheetmetal

smt_crn_rel_display

Sheetmetal

smt_form_abort_on_fail_plc

Sheetmetal

yes, no

no

smt_mp_method

Sheetmetal

mass, cg, both

cg

Parametric Technology Corporation

116

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Outside Mold Lines will be created during Flat Pattern creation. yes, no no

Category

Description

Values

Default value

smt_outside_mold_lines

Sheetmetal

snap_single_constraints

Without category

When dynamically dragging components during component placement, allow to snap to references one constraint at a time. Size of Spherical map texture image used for environment mapping. Bigger size will have better image quality but will be slow to regenerate. Determines whether or not the spin center symbol displays. Allows slower spinning when zoomed in on a model. Yes - 3D feature and model notes are displayed during dynamic spinning of a model. Display orientation center while reorienting. Yes - Datum features will be displayed during dynamic spinning of a model. Yes - Silhouette lines will be displayed during dynamic spinning of a model. Determines whether or not the application manager starts when Pro/ENGINEER is started. Provides the complete path to the directory containing start parts and assemblies. yes, no yes, no yes, no 256x256, 512x512, 1024x1024

yes, no

yes

spherical_map_size

Model Display

256x256

spin_center_display

Environment

yes no yes

spin_rate_zoom_sensitive

Model Display

spin_with_notes

Model Display

spin_with_orientation_center

Without category

yes, no yes, no no, yes yes, no

yes no no yes

spin_with_part_entities

Model Display

spin_with_silhouettes

Model Display

start_appmgr

Environment

start_model_dir

File Storage & Retrieval

Parametric Technology Corporation

117

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the file path of a NASTRAN deck template. Use full path to avoid problems. No - Output of Appearances, Layers, and Groups is enabled for STEP standard AP214. Yes - Output of Appearances, Layers, and Groups is enabled for STEP standard AP203. Toggles the default setting of the File Structure field in the STEP Export dialog box for supported assembly STEP export files. AS_3D_VIEWS - Export 3-D model geometry with its associative views. AS_3D_VIEWS_ASSOC_DRAFT - Export 3-D model geometry with its associative views and view related annotations. NO Export only 2-D representations of the 3-D models. This is the default. Specifies output format when exporting to STEP. AP203_IS - Formats output to ISO 10303 AP203IS format. AP214_CD Formats output with geometry that meets the specification for the long-term schema for AP214cc1. Specifies how tool path information is computed. Yes - Tool path information stored in file filename.tph (filename is manufacturing model name). No - Tool path is computed each time manufacturing model is retrieved or parameters are changed. Yes - Enable auto regeneration of curves. ap203_is ap214_cd ap202_is 203_is_ext ap214_dis ap209_dis ap214_is yes, no no, as_3d_views, as_3d_views_assoc_draft single_file, separate_parts_only, separate_all_objects single_file yes, no no

Category

Description

Values

Default value

std_nastran_template

Without category

step_appearance_layers_groups

Data Exchange

step_export_ap214_asm_def_mode

Data Exchange

step_export_dwg_views

Data Exchange

no

step_export_format

Data Exchange

ap203_is

store_tool_path_file

Manufacturing

yes

style_auto_regen_curves

Without category

yes, no

yes

Parametric Technology Corporation

118

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Enable auto regeneration of shaded surfaces. Yes - Enable auto regeneration of surfaces. Set scale factor of surface connection arrow. Number should be greater then 0. Yes - Add connections to a newly created Style surface. Yes - Display grid for active datum plane. Set the number of lines to display on grid. Number should be equal or greater than 2. Set the value of transparency for components set to "Transparent" in style state.Value must be between 0 and 100. On - Display surfaces mesh. Off - Do not display surfaces mesh. Off When Shaded Display surfaces mesh except when shaded. Sets the quality of the surface mesh. Values range is between 0.1 to 10. Refers to the one-line help Messages that are either displayed or not displayed. Suppresses "License expired: List of options and expiration days" dialog Yes - Suppresses the 'Regained Floating License' dialog box. No - The 'Regained Floating License' dialog box will display. Yes - Dimensions will be displayed in their symbolic format during drawing note creation. No - Dimensions will be displayed in drawing notes as numerical values. 119 yes, no yes, no off, on, off when shaded yes, no yes, no yes yes 5 70 1 yes, no yes yes, no yes

Category

Description

Values

Default value

style_auto_regen_shaded_surface

Without category

style_auto_regen_surface

Without category

style_connection_arrow_scale

Without category

style_default_connections

Without category

style_display_grid

Without category

style_grid_spacing

Without category

style_state_transparency

Without category

style_surface_mesh_display

Without category

off

style_surface_mesh_quality

Without category

1 no 7 no

summary_help

User Interface

suppress_dlg_license_expired

User Interface

suppress_license_loss_dialog

User Interface

switch_dims_for_notes

Drawing

yes, no

yes

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name With Pro/DETAIL, automatically regroups weld symbol instances after you move the text. Specifies the location of the symbol instance palette. Controls the display of the special symbol palette during note creation. Defines default graphics area background color. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Specifies the system color file. Use the full path name to avoid problems. Defines default curve color. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Defines default secondary highlight color. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. 0 0 yes, no yes yes, no no

Category

Description

Values

Default value

sym_leader_orient_move_text

Drawing

symbol_instance_palette_file

Drawing

symbol_palette_input

Drawing

system_background_color

Colors

system_colors_file

Colors

system_curves_color

Colors

system_dimmed_menu_color

Colors

Parametric Technology Corporation

120

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Defines default edge highlight color. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Defines default color of solid wireframe entities. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Defines default color of hidden, wireframe entities. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Defines default primary highlight color. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Inserts specified text file into the Start section of IGES files (refer to user_iges_header_file). When used with user_iges_header_file, the system text appears first. 0 0

Category

Description

Values

Default value

system_edge_high_color

Colors

system_geometry_color

Colors

system_hidden_color

Colors

system_highlight_color

Colors

system_iges_header_file

Data Exchange

Parametric Technology Corporation

121

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Defines default color of datum tags. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Defines default section color. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Defines default color of Sheetmetal parts. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Defines default color of Manufacturing volumes. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using View>Display Settings>System Colors. Specifies the name of a digitizing tablet. For display purposes only. Sets the angle between two quilt surfaces below which the edge will be displayed as tangent. Enter an angle between 1.5 and 15 degrees. 122 0.02618 0 0

Category

Description

Values

Default value

system_letter_color

Colors

system_section_color

Colors

system_sheetmetal_color

Colors

system_volume_color

Colors

tablet_device_name

System

tan_angle_for_disp

Model Display

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Determines how edges between tangent surfaces are displayed. Tbl_driven_tol_val_edit Y/N* - "Yes" allows users to directly edit the tolerance value of dimensions whose tolerance values are driven by tolerance tables. Editing the tolerance value of a dimension will make the dimension non-table-driven. "No" disallows direct editing of the tolerance values of table driven tolerances. Specifies the designated template assembly. Use full path to avoid problems. Specify the drawing used as the default drawing template. Specify the model used as the default ECAD assembly template. Specify the model used as the default ECAD part template. Specifies the designated template ESR assembly. Use full path to avoid problems. Specify the model used as the default flattened Harness assembly template. Specify the model used as the default Harness part template. Specify the model used as the default manufacturing cast template. Specify the model used as the default manufacturing cmm template. Specify the model used as the default manufacturing expert machinist template. Specify the model used as the default manufacturing mold template. 123 inlbs_mfg_cast.asm inlbs_mfg_cmm.asm inlbs_mfg_emo.asm inlbs_mfg_mold.asm inlbs_asm_esr.asm yes, no no no, solid, centerline, phantom, dimmed solid

Category

Description

Values

Default value

tangent_edge_display

Model Display

tbl_driven_tol_val_edit

Dimensions & Tolerances

template_designasm

File Storage & Retrieval

inlbs_asm_design.asm c_drawing.drw

template_drawing

File Storage & Retrieval

template_ecadasm

File Storage & Retrieval

template_ecadpart

File Storage & Retrieval

template_esrasm

Without category

template_flat_harness

Electromechanical

template_harnesspart

Electromechanical

template_mfgcast

File Storage & Retrieval

template_mfgcmm

File Storage & Retrieval

template_mfgemo

File Storage & Retrieval

template_mfgmold

File Storage & Retrieval

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Specify the model used as the default manufacturing assembly template. Specify the mold layout assembly used as a default template. Specify the model used as the default sheetmetal part template. Specify the model used as the default part template. Specifies the full path to the terminal emulator command (the command that starts shell windows). Use the command for your system. Enter the complete path name and the terminal command. YES - Unicode strings are exported in terminator table files, NO - Unicode strings are converted to ASCII characters for terminator table export. Yes - Applied textures will be displayed when the model is shaded. Appends a directory to the search path for textures. Enables you to position the thermometertype scales whenever they appear, so that they do not overlap the Pro/ENGINEER windows (if space permits, for example, if windows have been scaled). TIFF exports are done without compression. Determines the type of tiff items are exported to variables refer to color sets no_window_overlap, window_overlap window_overlap no, yes yes, no yes inlbs_mfg_nc.asm inlbs_mold_lay.asm

Category

Description

Values

Default value

template_mfgnc

File Storage & Retrieval

template_mold_layout

File Storage & Retrieval

template_sheetmetalpart

File Storage & Retrieval

inlbs_part_sheetmetal. prt inlbs_part_solid.prt

template_solidpart

File Storage & Retrieval

terminal_command

User Interface

terminator_table_out_unicode

Electromechanical

texture

Model Display

yes

texture_search_path

Model Display

thermo_position_hint

User Interface

tiff_compression

Data Exchange

none, g4, packbits, deflate rgb, palette, grayscale, mono

none rgb

tiff_type

Data Exchange

Parametric Technology Corporation

124

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Controls the initial format of the date displayed in a drawing. The format for the setting is a string consisting of three portions: the year, the month, and the date. You can enter the portions in any order. Displays dimensions with or without tolerances. Sets the tolerance mode of newly created dimensions. Yes - The Default check boxes in the number of digits area of the Dimension Properties dialog will be checked when a dimension is created or first shown. No The check boxes will be unchecked when a dimension is created or first shown. Sets the default tolerance class for ISOstandard models. The system uses the tolerance class in conjunction with the dimension value when retrieving tolerances for General or Broken Edge dimensions. Sets the tolerance standard used when creating the model. Sets the default directory for user-defined tolerance tables for ISO-standard models. All Holes and Shafts tables overwrite existing tables when loaded. Tells Pro/E the full path to which toolkit registry file to be used. This option replaces the R17 option prodevdat. yes, no nominal, limits, plusminus, plusminussym, plusminussym_super yes, no no limits %dd-%mmm-%yy

Category

Description

Values

Default value

todays_date_note_format

Drawing

tol_display

Dimensions & Tolerances

tol_mode

Dimensions & Tolerances

tol_num_digits_default_driven

Drawing

yes

tolerance_class

Dimensions & Tolerances

fine, medium, coarse, very_coarse

tolerance_standard

Dimensions & Tolerances

ansi, iso

ansi

tolerance_table_dir

Dimensions & Tolerances

toolkit_registry_file

Application Programming Interfaces

Parametric Technology Corporation

125

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Display tracesketches outside of Style feature Sets a delay in seconds between trail file steps. Instructs Pro/ENGINEER to create its trail file in the specified directory rather than in the startup directory. Specifies the default directory for training files. The path name must start from the root of the directory, for example, /home/users/library/training. Yes - Transparent colors will appear as such when the model is shaded. Enable travel bounds display. Transparency value for machine bound display. Subdivide filled areas into triangles (may affect memory usage and plot files). When set to Yes this option will add a "Show info items" filter to the View panel in the Troubleshooter. Defines how annotations using True Type Fonts are written to the plot file. Use True Type Fonts will reduce the plot file size, but font substitution may occur due to device settings. Annotations that do not use True Type Fonts are unaffected by this option. If set to yes, a sequential number will be appended to the name of annotation feature in group from Copy and UDF placement. 126 yes, no no, yes yes, no no, yes yes no 0.8 no no no, yes yes

Category

Description

Values

Default value

tracesketch

Without category

trail_delay

System

trail_dir

System

train_file_path

System

transparency

Model Display

travel_bounds_display

Without category

travel_bounds_transparency

Without category

triangulate_filled_areas

Drawing

troubleshooter_show_info_gcheck

Features

ttf_handling_for_plot_files

Printing & Plotting

stroke all fonts, use true type fonts

use

udf_af_name_postfix

Features

yes, no

yes

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Setup Pro/E Theme.Standard will result in the Wildfire Theme on UNIX and "following the Windows theme on Windows XP & Win2K. Wildfire - Will always use the Wildfire Theme regardless of the OS settings. Specifies the file containing the mapping for MCAT filename and units. wildfire, standard wildfire

Category

Description

Values

Default value

ui_theme

Without category

units_system_dic_file

Piping

/devsrc1/spg/system_1 /text/piping_data/maste r_catalog/piping_units_ system_dic_file.ptd yes, no yes

update_copy_geom_location

Assembly

Yes-Copy Geometry will try to update location of copied geometry based on changes to component placements even if some components are excluded or in graphics rep. Update cable line color for harness-mfg part created in release 2000i or earlier. Yes - When a cable is added between two previously laid out locations in a threedimensional reference harness, display of the new cable will update automatically in pre-Release 13 flattened cable models. Yes - Harnesses containing cables routed prior to Release 16.0 will be automatically updated upon retrieval to comply with new display standards. "Yes" updates top assembly simplified reps for replacements during regeneration and upon replacement. Specifies whether to support up to 8 plotter pens. The initial default is 4 pens. yes, no yes, no

update_harness_mfg_line_color

Electromechanical

no no

update_pre_130_harness

Electromechanical

update_pre_16_cable_layers

Electromechanical

yes, no

no

update_rep_refs

Assembly

yes, no

yes

use_8_plotter_pens

Printing & Plotting

no, yes

no

Parametric Technology Corporation

127

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Opens export options dialog when exporting Pro/E drawing. No - exports file without the options dialog. Used to disable the use of IGES font 1003. Specifies whether to convert Kanji notes in Pro/ENGINEER to IGES Kanji notes (font code) when exporting. Yes - Converts Kanji notes to IGES Kanji notes. No Converts using Font 1. Determines if fractional dimensions are displayed in terms of feet-inches or metermm. Yes - The major units are used. For example, when the units are inches and 25.125 is converted to a fraction, the dimension becomes 2' 1-1/8". Yes to retrieve master rep when graphics rep has no display data. yes, no yes, no no yes, no no yes, no yes yes, no yes

Category

Description

Values

Default value

use_export_2d_dialog

Data Exchange

use_iges_font_1003

Data Exchange

use_iges_kanji_font_2001

Data Exchange

use_major_units

Dimensions & Tolerances

use_master_for_bad_disp_reps

Without category

no

use_nom_dim_val_in_expr

Dimensions & Tolerances

Yes - use dimensions' nominal values in expressions.No - use current values. Determines how to color the hidden lines of parts that have user defined colors. "YES" - Use the dimmed part color for hidden lines.SYSTEM_HIDDEN_COLOR is ignored if it has been specified. Yes - Use the old stroke-based PTC font as the default font. No - Use a True Type font as the default font.

yes, no no, yes

no no

use_part_color_for_hidden_lines

Colors

use_pre_wildfire_text_font

Model Display

no, yes

no

Parametric Technology Corporation

128

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - The exact line style used in Pro/ENGINEER is plotted, stroked out dot by dot, dash by dash, and space by space. No - plots lines using the line font it supports which most closely resembles the font used in Pro/ENGINEER. Perform extra validation of user interface actions when playing back trail files. Explicitly makes Pro/ENGINEER use the Temp directory for regenerating instances of models. Controls whether HTML reports use the browser's standard fonts. Modify grid space in user defined length units for handle movement. Filename - Insert specified text file into the Start section of IGES file. Valid parametric note symbols will be replaced during export. For example, &dwg_name in the text file is replaced by the drawing name when a drawing is exported. No - Variable plot sizes may be entered in millimeters. No - Drawing items moved/copied to a different sheet or located on a changed sheet keep same size and relative orientation on paper. Yes - Some items scale/reposition to be the same on paper, and others scale and/or reposition to be the same on screen. yes, no yes, no yes no yes, no no, yes yes, no yes no yes, no no

Category

Description

Values

Default value

use_software_linefonts

Printing & Plotting

use_strict_ui_trail

Without category

use_temp_dir_for_inst

File Storage & Retrieval

use_web_page_font_in_reports

Without category

no 0.5

user_defined_grid_interval

Features

user_iges_header_file

Data Exchange

variable_plots_in_inches

Printing & Plotting

variant_drawing_item_sizes

Drawing

Parametric Technology Corporation

129

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name The complete filename of the text file containing VDA header information. If you intend to use the same header for all VDA files, specify the full pathname. Yes - "Verify Now" action will be selected in the conflict dialog by default when an unverified family table instance is to be saved in PDM workspace.No - "Verify Now" action will not be selected by default. The user may explicitly specify the "Verify Now" action in the conflict dialog. Yes - Indicates that a cutter is installed on a Versatec plotter. Specify whether sub-model annotations will be visible in assemblies.If set to "Active model only", only annotations of the active model will be visible.If set to "All", all annotations in sub-models will also be displayed. Annotation display in part mode is not affected. No - Mapkeys will run without displaying picks being made in the Menu Manager menus. This does not affect the display of picks being made in menu bar menus or dialog boxes. Sets the default number of visible message lines in the Pro/ENGINEER message area. Enables you to place an anchor on a specified VRML component during the export to VRML. The keywords are optional. Yes - Exports a model to VRML with the Pro/ENGINEER background color. 130 yes, no no no, yes no, yes active model only, all active yes, no no

Category

Description

Values

Default value

vda_header

Data Exchange

verify_on_save_by_default

File Storage & Retrieval

versatec_cutter_installed

Printing & Plotting

visible_annotations_scope

Assembly

visible_mapkeys

User Interface

no

visible_message_lines

User Interface

vrml_anchor_url

Data Exchange

vrml_background_color

Data Exchange

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Yes - Exports a model to VRML with explode lines for assembly or assembly process data. Specifies the number of levels of detail (LODs) in models exported in VRML format. Allows the user to choose between exporting to the VRML 2.0 or 1.0 format. Yes - Ensures that the model components retain their true color. No - In some viewers, component colors might not be consistent. All - Exports top-level and lower-level assembly component views into VRML format. None - Does not export component views into VRML format. Top - Exports top-level object view only into VRML format. Controls the export of user parameters. Designated - Export only designated parameters. All - Export all parameters. None - Do not export parameters. Yes - Specifies direct and in memory export of top-level assembly simplified representation to Pro/FLY-THROUGH package files. Yes - Returns the user to the dimension properties dialog to select a different table. No - Applies the tolerance according to existing functionality. Specify name and path of the file containing workcell and fixture name info. none, all, top yes, no 2.0, 1.0 2 no high, medium, low medium yes, no yes

Category

Description

Values

Default value

vrml_explode_lines

Data Exchange

vrml_export_resolution

Data Exchange

vrml_export_version

Data Exchange

vrml_file_duplicate_material

Data Exchange

vrml_multiple_views

Data Exchange

all

vrml_parameters

Data Exchange

designated, all, none

designated

vrml_simprep_export

Data Exchange

yes, no

no

warn_if_iso_tol_missing

Without category

yes, no

no

wcell_fixt_info_setup_file

Without category

Parametric Technology Corporation

131

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Enter number of days to store history records. Enter location of Pro/E browser home page. 20

Category

Description

Values

Default value

web_browser_history_days

System

web_browser_homepage

System

/devsrc1/spg/system_1 /html/chinese_tw/proe/ helpsystop/resource_c enter_index.htm

web_disable_js_command

Application Programming Interfaces Enables or disables Pro/Web.Link in the embedded browser. Enable the subscription mechanism for Connections Sets Pro/Web.Link permission to read data from the local file system. Sets Pro/Web.Link permission to write data to the local file system. Sets Pro/Web.Link permission to read data from a Pro/ENGINEER session. Sets Pro/Web.Link permission to modify data in a Pro/Engineer session. Yes - The Security dialog box is displayed when a Pro/Web.Link function requires security access beyond the current settings. Set the maximum email attachment size in kilobytes. 132 yes, no yes, no no, yes on, off

Enter a specific javascript command to be disabled off yes

web_enable_javascript

Without category

web_enable_subscription

Application Programming Interfaces

web_link_file_read

Application Programming Interfaces

no

web_link_file_write

Application Programming Interfaces

no

web_link_proe_read

Application Programming Interfaces

yes, no

no

web_link_proe_write

Application Programming Interfaces

yes, no

no

web_link_security_autoprompt

Application Programming Interfaces

yes, no

yes

web_max_mail_size

Without category

5000

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name No - Do not ask for X-section references when creating weld features. Yes - Ask for X-section references when creating weld features. Defines default weld color. The three decimal values specify (in order) percentage of red, green and blue in the resulting color. For example, 0 0 49 specifies a medium blue. Change in session using Tools>Colors>System. Sets the default number of decimal places (0-10) to display in weld parameters. Determines if the edge preparation feature is created in the part or theassembly level. Specifies an initial default value for the angle cut edge preparation. Specifies an initial default value for the edge preparation depth. Controls whether a family table instance is created for edge preparation. Yes Instances of the components that receive edge preparation are created. Specifies the suffix name for the instance that will be created during edge preparation. Part name plus extension makes the instance name. Specifies an initial default value for the root opening edge preparation. yes, no part, assembly 3 part 45 0.25 0 no, yes no

Category

Description

Values

Default value

weld_ask_xsec_refs

Weld

weld_color

Weld

weld_dec_places

Weld

weld_edge_prep_driven_by

Weld

weld_edge_prep_groove_angle

Weld

weld_edge_prep_groove_depth

Weld

weld_edge_prep_instance

Weld

weld_edge_prep_name_suffix

Weld

_noep

weld_edge_prep_root_open

Weld

0.25

Parametric Technology Corporation

133

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Applies only if weld_edge_prep is set to Yes. Generic - Edge preparation features are resumed in the generic and suppressed in the instance. Instance Edge preparation features are suppressed in the generic and resumed in the instance. Specifies the directory to search when a weld parameter file is needed. Specifies the directory to search when a weld parameter file is needed. Sets the default weld geometry type. Specifies the directory to search when a weld parameter file is needed. Specifies an initial default value for the radius at weld notch corner. Specifies an initial default value for the weld notch height. Specifies an initial default value for the weld notch radius. Specifies an initial default value for the weld notch width. Specifies the directory to search when a weld parameter file is needed. Specifies the directory to search when a weld parameter file is needed. Specifies standard for welding user interface. ANSI - Use ANSI standards. ISO - Use ISO standards. Gamma correction to apply to images created by renderer. Default value is 1.0. 134 iso, ansi ansi 0.1 0.4 0.5 0.5 surface, light surface generic, instance

Category

Description

Values

Default value

weld_edge_prep_visibility

Weld

weld_fillet_preferences_file

Without category

weld_general_preferences_file

Without category

weld_geom_type_default

Weld

weld_groove_preferences_file

Without category

weld_notch_corner_radius

Weld

weld_notch_height

Weld

weld_notch_radius

Weld

weld_notch_width

Weld

weld_plug_slot_preferences_file

Without category

weld_spot_preferences_file

Without category

weld_ui_standard

Weld

window_gamma

Photorender

Parametric Technology Corporation

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Select the type of embedded browser to be used. Scales Pro/ENGINEER windows with a given coefficient. A value of 0.85 is usually adequate to allow dynamic menus to display to the right of the Pro/ENGINEER window. Cut out are created in Workpiece but not the family table instances. Creates additional frame for each process step or for assembly publication. Yes Auxiliary files aux.html are created for each step in assembly process (in each step00 directory) to be replaced by your .html file. No - Auxiliary files are not created. Specifies the output format by to one of the values All - Writes all views in any component to the appropriate VRML files. Top - Writes only named views that reside in the assembly or process assembly to top-level VRML files. None - Does not write named views to VRML files. Specifies the location of the model tree in the browser window. Out - Opens model tree in a separate window. In - Includes model tree in the Web page and removes the Tree checkbox from the control panel. no, yes steps, operations_and_steps, none, operations no 1 ie_in_process, ie_in_sep_process, mozilla_based_browser

Category

Description

Values

Default value

windows_browser_type

System

windows_scale

User Interface

workpiece_instances

Without category

www_add_aux_frame

Data Exchange

www_export_geometry_as

Data Exchange

vrml, cgm, jpg, cgm_vrml, jpg_vrml, cgm_jpg, all none, all, top

jpg_vrml top

www_multiple_views

Data Exchange

www_tree_location

Data Exchange

out, in

out

Parametric Technology Corporation

135

Pro/ENGINEER Wildfire 5.0 Configuration Options

Name Sets the default view orientation for models (appears in the Orientation dialog box). The default orientation is the last option, x_angle, y_angle, or orientation, in the configuration file. Sets the default view orientation for models (appears in the Orientation dialog box). The default orientation is the last option, x_angle, y_angle, or orientation, in the configuration file. 0 0

Category

Description

Values

Default value

x_angle

Model Display

y_angle

Model Display

Parametric Technology Corporation

136

Pro/ENGINEER Wildfire 5.0 Configuration Options

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes


Category Without category undocked, docked docked Description Values Default value

Name

Status

accessory_window_display

NEW

advanced_style_surface_edit

CHANGED

Features Without category Assembly yes, no, prompt

Docked - Displays the accessory window embedded in the active window. Undocked - Displays the accessory window as a stand alone window. Use advanced options by default for Surface Edit in Style. yes, no no yes

allow_update_part_simp_rep_data

CHANGED

animate_explode_states

NEW

Model Display

Allow updating part Simplified Rep data in session automatically when switching from one Simp Rep to another.Yes - Allow updating part simplified rep data. No Do not update part simplified rep data. Prompt - Prompt the user if the current simplified Animate the transition between explode states and mold opening steps. yes, no Yes - Create Component Reference Backup, No - Do not Create Component Reference Backup. If the option is "yes" newly created rep would be updated each time on retrieve/regeneration. yes, no

no

auto_backup_new_placemnt_refs

NEW

Assembly

no

auto_evaluate_simprep_rules

NEW

Assembly

no, yes

no

Parametric Technology Corporation

137

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Data Exchange yes, no yes

Status

Category

Description

Values

Default value

cdt_transfer_details

DELETED

cmm_custom_tool_param_file

NEW

Manufacturing

No - Details (dittos) associated with the imported CADAM drawing are placed on the current Pro/ENGINEER drawing sheet. Yes - Each detail (ditto) associated with the imported CADAM drawing converts to a separate additional sheet. Defines the file that contains the user-defined tool parameters' list. Enable / Disable combined views customization. Sets the maximum allowable gap between weld contact surfaces. yes, no yes 0

combined_views_customization Without category

NEW

Without category

contact_surfaces_gap

NEW

datum_point_symbol

CHANGED

Model Display

cross

default_ang_units

NEW

Dimensions & Tolerances

Specifies the shape of datum point symbols displayed in Part or Assembly mode. Sets the display of newly created angular dimensions to decimal degrees (ang_deg),degrees and decimal minutes (ang_min) or degrees, minutes and decimal seconds (ang_sec) both in the model and in the drawing. Does not affect dimensions that already hav

dot dot, cross, circle, triangle, square ang_deg, ang_min, ang_sec

ang_deg

Parametric Technology Corporation

138

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Model Display Controls the display of dimension z-extension lines. Yes - z-extension lines will be displayed; No - z-extension lines will not be displayed. yes, no yes

Status

Category

Description

Values

Default value

display_z_extension_lines

CHANGED

dm_adv_import_file_types dm_adv_import_system_params dm_enable_import_export_ui drawing_setup_file yes, no

NEW NEW NEW CHANGED

Without category Without category Without category Drawing

no /shipsrcl01/spg/syste m_1/text/prodetail.dtl /devsrc1/spg/system _1/text/prodetail.dtl

dwg_unicode_conversion_languag e

CHANGED

Drawing

Sets the default drawing setup file option values for your Pro/ENGINEER session, otherwise, the system uses the default drawing setup file option values. Certain parameters in the file are valid only if you have a license for Pro/DETAIL. Defines the language used during Unicode conversion of pre-Wildfire 4.0 drawings. This option does not affect the conversion of models. File uses the language stored in the drawing header file; Session uses the language of the current Pro/E session. file, session file, session, usascii, english, japanese, french, german, russian, italian, spanish, korean, chinese_tw, chinese_cn, hebrew, greek, turkish, czech, polish, hungarian, slovenian, portuguese, slovak

file

Parametric Technology Corporation

139

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Data Exchange

Status

Category

Description

Values

Default value

dxf_export_mapping_file

DELETED

dxf_out_stroke_text

DELETED

Data Exchange

none, special, all

none

ecad_comp_xsec_def_name

CHANGED

Without category Data Exchange

Specifies the DXF export mapping file. Absolute or relative path to the file can be used. Strokes == text is converted to lines and dots. "NONE"Does not stroke out the text for export to DXF or DWG. "ALL" - Strokes out all the text. "SPECIAL" - Strokes out only special characters. Will allow pre-setting default X-section to be used for component outline output to *.eda format. Setup the default for the import of ECAD Holes type MTG (IDF 3.0 or IDX ONLY) yes, no, as lightweight yes, no yes, no, as lightweight yes

ecad_mtg_hole_import

NEW

Data Exchange

ecad_pin_hole_import

CHANGED

Data Exchange

no

ecad_tool_hole_import

NEW

Data Exchange

Setup the default for the import of ECAD Holes from type PIN (IDF 3.0 ONLY)Setup the default for the import of ECAD Holes from type PIN (IDF 3.0 or IDX ONLY) Setup the default for the import of ECAD Holes type TOOL (IDF 3.0 or IDX ONLY)

yes, no, as lightweight

yes

Parametric Technology Corporation

140

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Data Exchange yes, no yes, no, as lightweight yes

Status

Category

Description

Values

Default value

ecad_via_hole_import

CHANGED

enable_3dmodelspace_browser_ta b

NEW

Without category

yes, no

yes

explode_animation_max_time

NEW

Model Display

Setup the default for the import of ECAD Holes from type VIA (IDF 3.0 ONLY)Setup the default for the import of ECAD Holes from type VIA (IDF 3.0 or IDX ONLY) Yes - Display 3DModelSpace tab in the browser when Pro/E starts. No - Display 3DModelSpace tab only when user click a 3DModelSpece link in the navigator Sets the maximum amount of time an animation between explode states will take. 1 Sets the default shell element type in FEM mode. Specify the initial view for file dialogs: "LIST" or "DETAILS". Loads feature recognition application. Specifies the location of the geometry analysis color scheme file. tri, quad list, details quad list

fem_shell_elem_type

NEW

Without category

file_open_default_view

CHANGED

frt_enabled File Storage & Retrieval

NEW

Without category File Storage & Retrieval Without category

yes, no

no

geometry_analysis_color_scheme

NEW

Parametric Technology Corporation

141

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name System Sets the optional graphics environment used by certain platforms for running Pro/ENGINEER. Refer to the Installation Guide for a list of defaults and optional graphics.

Status

Category

Description

Values

Default value

graphics

CHANGED

opengl x_windows starbase xgl win32_gdi opengl

help_center_path

NEW

User Interface

URL of an active Pro/ENGINEER Help Center, if the Help Center is not installed at the default path (along with Pro/E product), of nature http://localhost:/index.jspx. Or, URL of the Pro/ENGINEER Help Center, that is deployed on a web server. Specifies not to generate or generate short or long log files for data exchange import operations. Specifies the name of the existing import profile to use by default. yes, no no, short, long no short

idd_repair_tangency intf_generate_log_file

NEW NEW

Without category Data Exchange

intf_in_profile_default

NEW

Data Exchange

intf_profile_dir

NEW

Data Exchange

intf2d_in_dxf_mapping_file

NEW

Data Exchange

Specifies the directory where import and export profiles are kept. Use the full path to avoid problems. Specifies the mapping file for DXF and DWG import. Absolute or relative path to the file can be used. 142 Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Parametric Technology Corporation

Name Data Exchange yes, no yes

Status

Category

Description

Values

Default value

intf2d_in_iges_symbols

NEW

intf2d_in_open_log_window

NEW

Data Exchange

Controls whether to import IGES symbols as symbols or entities by default. Yes Import IGES symbols as symbols by default. No Import IGES symbols as entities by default. Yes - Opens Import Log File in separate window. No - the Log File will not appear in the window. yes, no no If set to Yes, non-ASCII characters will be written in UNICODE encoding. Specifies the mapping file for DXF and DWG export. Absolute or relative path to the file can be used. none, special, all none yes, no no

intf2d_out_acad_unicode

NEW

Data Exchange

intf2d_out_dxf_mapping_file

NEW

Data Exchange

intf2d_out_stroke_text

NEW

Data Exchange

intf3d_out_annotations Data Exchange

NEW

Data Exchange

Strokes == text is converted to lines and dots. "NONE"Does not stroke out the text for export. "ALL" - Strokes out all the text. "SPECIAL" Strokes out only special characters. Export annotations with models.

yes, no

yes per_part

intf3d_out_jt_structure

NEW

intf3d_out_notes intf3d_out_parameters

NEW NEW

Data Exchange Data Exchange 143

Specifies product structure to file structure mapping defined in JT Open Toolkit. Exports notes with models. Exports parameters with models.

per_part, fully_shattered, monolithic yes, no all, none, designated

yes all Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Parametric Technology Corporation

Name Piping Specifies the mapping between isogen parameter and attribute name.

Status

Category

Description

Values

Default value

isogen_attribute_map_file

CHANGED

isogen_endtype_map_file

CHANGED

Piping

Specify name of file mapping Pro/Piping endtypes with ISOGEN endtypes

isogen_nominal_size_map_file

CHANGED

Piping

Specify name of file mapping Pro/Piping Size with Nominal Sizes in MM and Inches

isogen_symbol_map_file

CHANGED

Piping

Specify name of file for mapping Pro/Piping selection names with ISOGEN symbol keys (SKEY)s

/shipsrcl01/spg/syste m_1/text/piping_data/ isodata/isogen_attrib ute_map.ptd /devsrc1/spg/system _1/text/piping_data/is odata/isogen_attribut e_map.ptd /shipsrcl01/spg/syste m_1/text/piping_data/ isodata/isogen_endty pe_map.ptd /devsrc1/spg/system _1/text/piping_data/is odata/isogen_endtyp e_map.ptd /shipsrcl01/spg/syste m_1/text/piping_data/ isodata/isogen_nomi nal_size_map.ptd /devsrc1/spg/system _1/text/piping_data/is odata/isogen_nomina l_size_map.ptd /shipsrcl01/spg/syste m_1/text/piping_data/ isodata/isogen_symb ol_map.ptd /devsrc1/spg/system _1/text/piping_data/is odata/isogen_symbol _map.ptd

Parametric Technology Corporation

144

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Without category no, yes no

Status

Category

Description

Values

Default value

keep_model_in_open_window

NEW

keep_style_items_hidden_on_exit

CHANGED

Features Without category Without category Sets the directory that holds the temp files for the session recording mechanism. yes, no

Controls whether a model will be kept displayed in its window while accessory window is used. Keep style entities hidden after exiting of the Style feature definition. yes, no no /home/kapig/.wf/.setti ngs yes

last_session_directory_path

NEW

last_session_retrieval

NEW

Without category

make_aux_view_notes

CHANGED

Drawing

yes, no

no

menu_manager_position

NEW

User Interface

Yes - Activates recording mechanism that enables the session to be retrieved during the next session. No - The recording mechanism is not available and the session can not be retrieved. Automatically adds view names to auxiliary views using AUX VIEW* viewnameviewname. You can modify the view name after adding the view to the drawing. outside: Top left corner of Menu Manager is aligned to top right corner of window,inside: Top right corner of Menu Manager is aligned to top right corner of graphics area,adaptive: Behavior is like 'outside' unless there's not enough room available,

outside, inside, adaptive

adaptive

Parametric Technology Corporation

145

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Features User Interface Determines whether the generic name is displayed as an extension of the instance name in the model tree and other model name lists. Location of the setup file that describes which process parameters will be included in the parameter table. yes, no no Sets the default merge type surface merge operations. join, intersect intersect

Status

Category

Description

Values

Default value

merge_type

NEW

modeltree_show_gen_of_instance

NEW

nc_autodoc_param_dir

NEW

Manufacturing

nc_autodoc_report_dir

NEW

Manufacturing

nc_autodoc_setup_dir

NEW

Manufacturing

nc_autodoc_template_dir

NEW

Manufacturing

Location for storing the report and images generated by the shop floor documentation tool. Location for documentation setup files that describe which process parameters will be included in the parameter table. Location of the style sheet and default images used for shop floor documentation. Sets path for storage and retrieval of stock instances for creating workpiece in NC Model. Specify full path, including part name, to avoid problems. /shipsrcl01/spg/syste m_1/text/ncmdl_data/ ncmdl_bar.prt /devsrc1/spg/system _1/text/ncmdl_data/n cmdl_bar.prt

ncmdl_bar_stock_part_path

CHANGED

Manufacturing

Parametric Technology Corporation

146

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Manufacturing

Status

Category

Description

Values

Default value

ncmdl_billet_stock_part_path

CHANGED

new_wf5_simp_rep_ui

NEW

Without category

yes, no

/shipsrcl01/spg/syste m_1/text/ncmdl_data/ ncmdl_billet.prt /devsrc1/spg/system _1/text/ncmdl_data/n cmdl_billet.prt yes

pipeline_assembly_library_dir

CHANGED

Piping

Sets path for storage and retrieval of stock instances for creating workpiece in NC Model. Specify full path, including part name, to avoid problems. Yes - Use Component Chooser base Simp Rep UI, No - Use old Simp Rep definition UI. Sets the default pipeline assembly library directory.

piping_appearance_map_file

CHANGED

Piping

Sets the default piping appearance map filename.

piping_bolt_nut_select_file

CHANGED

Piping

Piping bolts and nuts selection file.

/shipsrcl01/spg/syste m_1/text/piping_data/ pipelinelib/ /devsrc1/spg/system _1/text/piping_data/pi pelinelib/ /shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/pipin g_appearance.map /devsrc1/spg/system _1/text/piping_data/m aster_catalog/piping_ appearance.map /shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/pipin g_bolt_nut_select.ptd /devsrc1/spg/system _1/text/piping_data/m aster_catalog/piping_ bolt_nut_select.ptd

Parametric Technology Corporation

147

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Piping Sets the default piping end compatibility filename.

Status

Category

Description

Values

Default value

piping_end_compatibility_file

CHANGED

piping_extend_dim_scheme

CHANGED

Piping

Specify a dimension scheme for piping extend segment. Sets the default piping fitting category map filename.

cartesian, cylindrical, spherical

/shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/pipin g_end_compatibility. ptd /devsrc1/spg/system _1/text/piping_data/m aster_catalog/piping_ end_compatibility.ptd spherical cartesian

piping_fitt_category_map_file

CHANGED

Piping

piping_fitt_library_dir

CHANGED

Piping

Sets the default piping fitting library directory.

/shipsrcl01/spg/syste m_1/text/piping_data/ sample_project/pipin g_fitt_category_map. ptd /devsrc1/spg/system _1/text/piping_data/s ample_project/piping _fitt_category_map.pt d /shipsrcl01/spg/syste m_1/text/piping_data/ fittinglib/ /devsrc1/spg/system _1/text/piping_data/fit tinglib/

Parametric Technology Corporation

148

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Piping Sets the default piping insulation directory filename.

Status

Category

Description

Values

Default value

piping_insulation_dir_file

CHANGED

piping_manufacture_dir_file

CHANGED

Piping

Sets the default piping manufacture directory filename.

piping_material_file

CHANGED

Piping

Sets the default piping material filename.

piping_mcat_dir

CHANGED

Piping

Sets the default piping master catalog directory.

/shipsrcl01/spg/syste m_1/text/piping_data/ sample_project/pipin g_insulation_dir.ptd /devsrc1/spg/system _1/text/piping_data/s ample_project/piping _insulation_dir.ptd /shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/pipin g_manufacture_dir.pt d /devsrc1/spg/system _1/text/piping_data/m aster_catalog/piping_ manufacture_dir.ptd /shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/pipin g_material.ptd /devsrc1/spg/system _1/text/piping_data/m aster_catalog/piping_ material.ptd /shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/ /devsrc1/spg/system _1/text/piping_data/m aster_catalog/

Parametric Technology Corporation

149

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Piping Sets the default piping master catalog directory filename.

Status

Category

Description

Values

Default value

piping_mcat_dir_file

CHANGED

piping_project_data_dir

CHANGED

Piping

Sets the default Project data directory.

piping_spec_dir_file

CHANGED

Piping

Sets the default piping specification directory filename.

popup_refpairintch_window

DELETED

Without category

Bring forward the window being used with the reference pairing table. Set the default preferred deliverable for the Publish Context in Drawings. Sets the default font directory (Pro/ENGINEER will load all fonts in this directory into the drawing regardless of the contents of the system and working directories).

yes, no

/shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/pipin g_mcat_dir.ptd /devsrc1/spg/system _1/text/piping_data/m aster_catalog/piping_ mcat_dir.ptd /shipsrcl01/spg/syste m_1/text/piping_data/ sample_project/ /devsrc1/spg/system _1/text/piping_data/s ample_project/ /shipsrcl01/spg/syste m_1/text/piping_data/ sample_project/pipin g_spec_dir.ptd /devsrc1/spg/system _1/text/piping_data/s ample_project/piping _spec_dir.ptd no

preferred_publish_deliverable

NEW

Drawing

print, iges, set, dxf, step, cgm, pdf, dwg, tiff, medusa, stheno

print

pro_font_dir

CHANGED

File Storage & Retrieval

/shipsrcl01/spg/syste m_1/text/fonts/ /devsrc1/spg/system _1/text/fonts/

Parametric Technology Corporation

150

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Data Exchange Specifies the directory in which Granite application plug-ins are located. Use the full pathname to avoid problems. Allows the user to specify the path to LWA library.

Status

Category

Description

Values

Default value

pro_gplug_dir

CHANGED

pro_lwa_library_path

DELETED

Without category

/shipsrcl01/spg/syste m_1/sun_solaris_x64 /gplugs/ /devsrc1/spg/system _1/sun_solaris_x64/g plugs/ /shipsrcl01/spg/syste m_1/graphiclibrary/smdata/archiv es/

pro_lwa_license_path Drawing Sets the default directory for drawing symbol palette files.

DELETED

Photorender

Allows the user to specify the path to LWA license file.

pro_palette_dir

CHANGED

pro_surface_finish_dir

CHANGED

File Storage & Retrieval

Sets the default directory for your user-defined surface finish symbols. Use the full pathname to avoid problems. Sets path to directory that contains the punch models. Disable realtime rendering. disable, transparent_floor, room_display

/shipsrcl01/spg/syste m_1/symbols/palette/ /devsrc1/spg/system _1/symbols/palette/ /shipsrcl01/spg/syste m_1/symbols/surffins / /devsrc1/spg/system _1/symbols/surffins/

punch_models_directory Model Display

NEW

Sheetmetal

real_time_rendering_display

NEW

disable

Parametric Technology Corporation

151

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Without category resolve_mode, no_resolve_mod e no_resolve_mode

Status

Category

Description

Values

Default value

regen_failure_handling

NEW

regen_simp_retrieve

CHANGED

File Storage & Retrieval

yes, no

yes no

replace_history_rule_order

CHANGED

Assembly

disable, 1, 2, 3, 4, 5

replace_interface_rule_order

CHANGED

Assembly

Specifies whether to enter resolve mode when regeneration failures occur.Resolve_mode - Enter resolve mode when regeneration failures occur. No_resolve_mode - Don't enter resolve mode when regeneration failures occur. Ask_user - Let the user decide wh Regenerate the assembly when retrieving an assembly simplified representation. Yes - Regenerates the assembly on retreival.No - The assembly is not regenerated on retrieval. Set the default order of the history evaluation rule in the replace operation. Disable the evaluation rule will be disabled by default. Number set the order of the rule relative to other evaluation rules. Set the default order of the interface evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. disable, 1, 2, 3, 4, 5 1

Parametric Technology Corporation

152

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Assembly disable, 1, 2, 3, 4, 5 5

Status

Category

Description

Values

Default value

replace_sameid_rule_order

CHANGED

replace_samename_rule_order

CHANGED

Assembly

disable, 1, 2, 3, 4, 5

replace_sameparam_rule_order

CHANGED

Assembly

disable, 1, 2, 3, 4, 5

replace_unrelated_automatic

CHANGED

Assembly

Set the default order of the same id evaluation rule in the replace operation. Disable the evaluation rule will be disabled by default. Number set the order of the rule relative to other evaluation rules. Set the default order of the same name evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. Set the default order of the same parameters evaluation rule in the replace operation. Disable - the evaluation rule will be disabled by default. Number - set the order of the rule relative to other evaluation rules. Availability of automatic reference pairing in unrelated replace. No - Automatic reference pairing is not available. Yes - Automatic reference pairing is available. yes, no no Setup whether the terminal splices of cables are reported. yes, no no

report_end_splice

NEW

Electromechanic al

Parametric Technology Corporation

153

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name User Interface 1

Status

Category

Description

Values

Default value

reserved_menu_space

CHANGED

round_displayed_dim_values

NEW

Dimensions & Tolerances

yes, no

yes

save_drawing_picture_file

CHANGED

Drawing

no, export, embed, both

no embed

show_annotations_dialog_limit Without category

NEW

Drawing

Reserves space for extra menus to the right of the Pro/ENGINEER window (1.04.0). This option overrides windows_scale.Reserves space for extra menus to the right of the Pro/ENGINEER window (0.0-4.0). This option overrides windows_scale. No - newly created or first shown dimension is displayed with all its significant decimals."Rounded Dimension Value" Check Box will be unchecked while opening Dimension Properties Dialog. Yes number of decimals is rounded according to defa Embed - Embeds a picture file inside a drawing for preview purposes. Export Saves a drawing file as a picture file in the working directory when saving a drawing. Both - Does both embed and export. Default value for annotations dialog Yes - show a column for Description field for all tabs in view manager. yes, no no

show_description_view_mgr

NEW

Parametric Technology Corporation

154

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Without category 0.0012

Status

Category

Description

Values

Default value

sim_auto_map_max_dist

CHANGED

sim_auto_pairing_thickness

NEW

Without category

sim_check_jacobian_corners

NEW

Without category

yes, no

no

sim_display_current_csys_triad

NEW

Without category

yes, no

sim_display_highlight_refs

NEW

Without category

Sets the default maximum distance tolerance for automapping of pressure load.Sets the default maximum distance tolerance (relative to model size) for auto-mapping of pressure load. The default value is 0.0012. Set the value of characteristic thickness for auto-detection of shell pairs. Using this as a threshold value, autodetection will find surface pairs with thickness smaller than this value. No - Suppress Jacobian checks at corner nodes (default). ANSYS and Nastran will check parabolic elements Jacobian at the integration points only and FEM will fix too curved elements for the same criterion. Yes - Jacobian is checked both at integration p Toggles display of the current coordinate system triad in the lower right corner of the window. If set to yes, selecting a load/constraint will highlight its geometrical references. yes, no

Parametric Technology Corporation

155

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Without category yes, no

Status

Category

Description

Values

Default value

sim_display_load_name

NEW

sim_display_mesh_control_name

NEW

Without category

If set to yes, the load/constraint name is displayed in the label. If set to yes, the Mesh/AutoGEM control name is displayed in the label. yes, no If set to yes, the Mesh/AutoGEM control value is displayed in the label. Toggles display of shells pairs. Toggles z-buffered display of Mechanica icons. yes, no 30 no, yes yes, no

sim_display_mesh_control_value

NEW

Without category

sim_display_shell_pairs Without category Without category

NEW

Without category

sim_display_z_buffered

NEW

sim_extend_surf_max_angle

NEW

sim_icon_distribution_density

NEW

Without category

Controls the maximum angle between a surface to be extended during shell compression and its adjacent surfaces. If the angle is higher than specified, the adjacent surfaces will be extended. The default is 30 degrees. The range is from 0 to 90 degrees. Determines how many icons are drawn for a distribution. 1 is fewer, 10 is the highest. Yes - Unpaired surfaces are ignored when meshing the model, placing you directly into the AFTER COMP menu (the CONT MESH menu is skipped). yes, no

-1

sim_ignore_unpaired

NEW

Without category

no

Parametric Technology Corporation

156

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Without category actual, 1, 2, 3, 4, 5 5

Status

Category

Description

Values

Default value

sim_pp_display_beam_thickness

NEW

sim_pp_path_absolute

CHANGED

Without category

yes, no

yes no

sim_remove_unopposed

NEW

Without category

yes, no

no

simprep_default_model_status

NEW

Assembly

exclude

simulation_product

CHANGED

Without category

exclude, master, graphics, geometry structure, thermal, prompt

prompt

sketcher_dec_places

DELETED

Sketcher

Sets the thickness for beams and 2D-shells display in Post Processor. Numerical values specify the thickness in pixels. Choose Absolute (Yes) or Relative (No) path to "rwd" file. Yes - The system ignores unopposed surfaces when meshing the model; the system also deselects the UseUnopposed option. No the system uses the unopposed surfaces in the shell model. Determines the default model status while defining a new simplified rep. Set Mechanica product being selected (Structure/Thermal). Prompt (default) -Brings Mechanica Model Type Dialog. This option is used only if the information about Mechanica product is not yet stored with model. Sets the default number of decimal places displayed for dimensions in Sketcher. The extrusion depth or any other dimension you enter to create 3D geometry is controlled by the default_dec_places option. 2 157

Parametric Technology Corporation

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Sketcher Specifies which sketcher to use. Yes - Intent Manager is the default. No - Old sketcher is the default. This option enable the user to keep a highly precise value during creation or convertion strong dimension. yes, no yes yes, no yes yes, no yes

Status

Category

Description

Values

Default value

sketcher_intent_manager

DELETED

sketcher_strngthn_to_def_dec_pl

NEW

Without category

snap_single_constraints

NEW

Without category

step_export_format

CHANGED

Data Exchange

ap203_is ap214_cd ap202_is 203_is_ext ap214_dis ap209_dis ap214_is yes, no yes, no

ap203_is

style_auto_regen_curves Without category

NEW

Without category

When dynamically dragging components during component placement, allow to snap to references one constraint at a time. Specifies output format when exporting to STEP. AP203_IS - Formats output to ISO 10303 AP203IS format. AP214_CD - Formats output with geometry that meets the specification for the long-term schema for AP214cc1. Yes - Enable auto regeneration of curves.

yes yes

style_auto_regen_shaded_surface

NEW

style_auto_regen_surface Without category

NEW

Without category

Yes - Enable auto regeneration of shaded surfaces. Yes - Enable auto regeneration of surfaces. Set scale factor of surface connection arrow. Number should be greater then 0. Yes - Display grid for active datum plane.

yes, no

yes 1

style_connection_arrow_scale

NEW

style_display_grid

NEW

Without category 158

yes, no

yes Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Parametric Technology Corporation

Name Without category 5

Status

Category

Description

Values

Default value

style_grid_spacing

NEW

style_surface_mesh_display

NEW

Without category

off, on, off when shaded

off

style_surface_mesh_quality

NEW

Without category

Set the number of lines to display on grid. Number should be equal or greater than 2. On - Display surfaces mesh. Off - Do not display surfaces mesh. Off When Shaded Display surfaces mesh except when shaded. Sets the quality of the surface mesh. Values range is between 0.1 to 10. 1 Refers to the one-line help Messages that are either displayed or not displayed. yes, no yes no

summary_help

CHANGED

User Interface

template_mfgcast

CHANGED

File Storage & Retrieval File Storage & Retrieval File Storage & Retrieval File Storage & Retrieval File Storage & Retrieval

inlbs_mfg_cast.mfg inlbs_mfg_cast.asm inlbs_mfg_cmm.mfg inlbs_mfg_cmm.asm inlbs_mfg_emo.mfg inlbs_mfg_emo.asm inlbs_mfg_mold.mfg inlbs_mfg_mold.asm inlbs_mfg_nc.mfg inlbs_mfg_nc.asm

template_mfgcmm

CHANGED

template_mfgemo

CHANGED

template_mfgmold

CHANGED

template_mfgnc

CHANGED

Specify the model used as the default manufacturing cast template. Specify the model used as the default manufacturing cmm template. Specify the model used as the default manufacturing expert machinist template. Specify the model used as the default manufacturing mold template. Specify the model used as the default manufacturing assembly template.

Parametric Technology Corporation

159

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Drawing yes, no yes

Status

Category

Description

Values

Default value

tol_num_digits_default_driven

CHANGED

ttf_handling_for_plot_files

NEW

Printing & Plotting

stroke all fonts, use true type fonts

use

units_system_dic_file

CHANGED

Piping

Yes - The Default check boxes in the number of digits area of the Dimension Properties dialog will be checked when a dimension is created or first shown. No The check boxes will be unchecked when a dimension is created or first shown. Defines how annotations using True Type Fonts are written to the plot file. Use True Type Fonts will reduce the plot file size, but font substitution may occur due to device settings. Annotations that do not use True Type Fonts are unaffected by this op Specifies the file containing the mapping for MCAT filename and units.

update_copy_geom_location

NEW

Assembly

Yes-Copy Geometry will try to update location of copied geometry based on changes to component placements even if some components are excluded or in graphics rep. 160

yes, no

/shipsrcl01/spg/syste m_1/text/piping_data/ master_catalog/pipin g_units_system_dic_f ile.ptd /devsrc1/spg/system _1/text/piping_data/m aster_catalog/piping_ units_system_dic_file .ptd yes

Parametric Technology Corporation

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name Data Exchange yes, no no

Status

Category

Description

Values

Default value

use_cadam_plot_data

DELETED

web_browser_homepage

CHANGED

System

Determines whether the information in the Plot Axis System element should be taken into account when importing a CADAM drawing. Enter location of Pro/E browser home page. /shipsrcl01/spg/syste m_1/html/chinese_tw /proe/helpsystop/reso urce_center_index.ht m /devsrc1/spg/system _1/html/chinese_tw/p roe/helpsystop/resour ce_center_index.htm

weld_fillet_preferences_file

NEW

Without category

Specifies the directory to search when a weld parameter file is needed. Specifies the directory to search when a weld parameter file is needed. solid, light surface, light solid surface

weld_general_preferences_file

NEW

Without category

weld_geom_type_default Without category

CHANGED

Weld

weld_groove_preferences_file

NEW

Sets the default weld geometry type. Specifies the directory to search when a weld parameter file is needed. Specifies the directory to search when a weld parameter file is needed. Specifies the directory to search when a weld parameter file is needed.

weld_plug_slot_preferences_file

NEW

Without category

weld_spot_preferences_file

NEW

Without category

Parametric Technology Corporation

161

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

Name System Select the type of embedded browser to be used.

Status

Category

Description

Values

Default value

windows_browser_type

NEW

workpiece_instances

CHANGED

Without category

Instances are created in Workpiece for each steps.Cut out are created in Workpiece but not the family table instances.

ie_in_process, ie_in_sep_proces s, mozilla_based_br owser steps, operations_and_ steps steps, operations_and_ steps, none, operations

Parametric Technology Corporation

162

Pro/ENGINEER Wildfire 4.0 to 5.0 Configuration Options Changes

You might also like