01 DESCRIPTION This Section covers providing everything necessary for, and incidental to, the execution required for all concrete joint WORK as shown on the Construction Drawings and specified herein, complete and acceptable to Company Representative. 1.02 QUALITY ASSURANCE Reference Codes and Standards: Comply with applicable SAUDI ARAMCO Standards, and Codes and Standards as specified herein. REFERENCE STANDARDS A. American Society for Testing and Materials (ASTM) 1. 2. 3. ASTM C 920, Standard Specifications for Elastomeric Joint Sealants. ASTM C 962, Standard Guide for use of Elastomeric Joint Sealant. ASTM D 1751, Standard Specification for Preformed Expansion joint fillers for concrete paving and structural construction (Non-extruding and resilient Bituminous types).
B.
American Concrete Institute (ACI) 1. ACI-504-R-77, Guide to Joint Sealants for Concrete Structures.
1.04
SUBMITTAL A. Submit the following to SAUDI ARAMCO Representative for approval prior to ordering of materials: 1. Product data for all materials stating the location where product to be used. 2. Certification that materials meet the specifications. 3. Manufacturers application and installation instructions. 4. Samples of water stops and joint fillers. 5. Colors samples or charts for joint compounds.
1.05
CONSTRUCTION SPECIFICATIONS
DOC
SABG GIRLS ELEMENTARY SCHOOL AND BOYS INTERMEDIATE SCHOOL MUBARRAZ AND HOFUF
089/ 090
A 2050
BE-315756
1 of 5
Store epoxy joint materials in a cool place. containers. PART 2 - PRODUCTS 2.01 MATERIALS A. Expansion Joints:
Joint filler shall be preformed non-extruding Bituminous filler type conforming to ASTM D1751 and shall be with thickness equivalent to joint width indicated and of suitable length , as far as practicable, so no longitudinal field cutting will be required. B. Joint sealant 1. General Compounds abutting each other are to be compatible. 2. Horizontal Joints Joints sealant for joints in horizontal or nearly horizontal surfaces conform to ASTM C 920, Type S or M, Grade P, Class 25. Use T (traffic sealant) in pedestrian and vehicular traffic areas, and use NT (non traffic) sealant in non-vehicular area. 3. Wall Joints Joint sealant for joints in walls conforms to ASTM C 920, Type S or M Grade NS, Class 25. 4. Bond breaker for joint sealant Polyethylene tape, coated paper, metal foil or similar type materials. 2.02 MIXING A. Joint Sealant: 1. 2. Minimum Temperatures: Mix only when temperatures of both components are above 10 deg. C. Procedure: a. Mix per manufacturer instructions.
SECTION 03410
CONSTRUCTION SPECIFICATIONS
DOC
SABG GIRLS ELEMENTARY SCHOOL AND BOYS INTERMEDIATE SCHOOL MUBARRAZ AND HOFUF
089/ 090
A 2050
BE-315756
2 of 5
b.
During warm weather (26 deg.C. and above) do not mix more material than can be placed within 5 minutes of mixing, 30 minutes in cool weather (11 to 25 deg.C).
2.3
MANUFACTURER 1. 2. Joint Sealant: Hilti/Gurisil No. 260, or approved equal. Joint Primer: Hilti/Gurisil No. 435.5 or approved equal.
PART 3 - EXECUTION 3.01 CONSTRUCTION JOINTS A. General Locate and install construction joints, which are not shown on the drawings, so as not to impair strength and appearance of the structure, as acceptable to the Company Representative. 1. Form a key with a width of one-third the thickness of the thinner member and a depth of 40 mm unless otherwise shown (12mm for slabs-ongrade). Tape key to facilitate removal of form. Carry all reinforcement through the joint. Do not remove key or forms until concrete has cured. Clean key of laitance, curing compound foreign materials and protrusions of hardened concrete before casting abutting WORK.
2. 3. 4. 5. B. Forms
Use slightly tapered key groove forms to permit form removal without damage to groove after concrete is cured. C. Concrete Placement Consolidate concrete during placement in vicinity of key and key groove. Do not remove key to key groove forms until after concrete has cured. D. Concrete Cleaning and Protection Clean key or key groove of curing compound, foreign materials, protrusions of hardened concrete and blow out debris and dust with oil free compressed air, protect exposed key and key groove from damage. SECTION 03410
CONSTRUCTION SPECIFICATIONS
DOC
SABG GIRLS ELEMENTARY SCHOOL AND BOYS INTERMEDIATE SCHOOL MUBARRAZ AND HOFUF
089/ 090
A 2050
BE-315756
3 of 5
3.02
EXPANSION JOINTS A. Provide expansion joint in slabs on grad at all points of contact between slabs on grade and vertical surfaces, such as column pedestals, foundation walls, grade beams and elsewhere as indicated.
3.04
PRE-MOLDED JOINTS FILLER A. General Treat cut surface as recommended by manufacturer, when filler strips are cut. B. Placement 1. 2. Place filler against the bulkhead form and fasten to the inside of the form with non-corrodible fasteners. Prevent disturbance of or damage to joint filler.
3.
Fill expansion joint completely. C. Wood Strips and Placement 1. Secure wood strips to surfaces, which are to receive joint compound. 2. Use slightly tapered wood strips of the same width as the expansion joint and of the depth necessary to install the joint compound. 3. Use materials to secure joint filler and wood strips, which will not harm concrete or affect the joint compound bond to concrete. 4. Do not remove wood strips until after the concrete curing period. D. Cleaning and Protection Clean groove of curing compound, foreign materials, protrusions of hardened concrete, blow out dust with oil-free compressed air. 3.05 JOINT SEALANT A. General Clean and dry concrete to be sealed in accordance with manufacurers printed instruction.
SECTION 03410
CONSTRUCTION SPECIFICATIONS
DOC
SABG GIRLS ELEMENTARY SCHOOL AND BOYS INTERMEDIATE SCHOOL MUBARRAZ AND HOFUF
089/ 090
A 2050
BE-315756
4 of 5
B.
Sealant Placement 1. Prime concrete, fill flush with joint compound of required thickness, tool to concave joint and seal, if required, all in accordance with the manufacturers instructions and ASTM C 962. 2. Prevent spilling sealant over adjoining surfaces. Use tape adjacent to joint if required. Remove all tape completely from concrete surface. 3. Do not apply sealant when sealant, air or concrete temperature is less than 40F.
C.
CONTRACTOR shall protect sealant from pedestrian traffic a minimum of 24 hours or until product is satisfactory cured. END OF SECTION
SECTION 03410
CONSTRUCTION SPECIFICATIONS
DOC
SABG GIRLS ELEMENTARY SCHOOL AND BOYS INTERMEDIATE SCHOOL MUBARRAZ AND HOFUF
089/ 090
A 2050
BE-315756