DIgSILENT PowerFactory Function
DIgSILENT PowerFactory Function
Functions
PowerFactory: Functions
Load Flow/Transmission
Fast and Accurate Load Flow Algorithm (Full Newton Raphson, Newton-Raphson Current Iteration) AC and DC Networks (for HVDC Transmission) Secondary Power-Frequency Control Primary Control Secondary Reactive Power-Voltage Control Load Profiling P-V Curves All Types of Sensitivities (dv/dQ, dphi/dP, Branch Sensitivities etc.) Modal dv/dQ Analysis
PowerFactory: Functions
Load Flow/Distribution
Any Type of Network Technology: Three-Phase,Three-Phase-Four Wire, Two-Phase, Bi-Phase, Single Wire-Earth Return, DC Networks Any Type of Network Topology (Meshed and Radial) Suited for Extremely Large MV Networks (>20000 Bus Bars) Voltage Profile Diagrams Stochastic Load Models for Considering Load Diversity in LV Networks One- and Two-Dimensional Load Profiles Feeder Scaling Open Point Optimization
PowerFactory: Functions
PowerFactory: Functions
Short Circuit
Short Circuits According to IEC 60909, ANSI C37 and Complete Superposition Method Full Implementation of IEC 60909/2001 Multiple Faults Analysis Fault Types: Three-Phase Two-Phase Two-Phase to Ground Single-Phase to Ground Inter-Circuit (also Between Different Voltage Levels) Open Conductor Sliding Faults along Lines
PowerFactory: Functions
Stability
Transient and Dynamic Stability Highly Accurate Generator and Load Models Large Library of Standard Models User Defined Modeling Variable Step Size Algorithm Easy-to-Use Chart Definition Interactive Event Definition Small Signal Analysis (Modal Analysis)
PowerFactory: Functions 6
Electromagnetic Transients
Detailed Network Model Transformer Saturation Transformer Capacitances Distributed Parameter Line Models (Constant and Frequency Dependent) Detailed (Switching) Power Electronics Device Models Easy-to-Use Chart Definition Interactive Event Definition Variable Step Size Algorithm
PowerFactory: Functions 7
Overcurrent Protection
Modeling CT and VT Models Fuses OCT-Relays Directional Relays Differential Relays LV Circuit Breakers Coordination Selectivity Diagrams Simulation Steady State Time Domain
PowerFactory: Functions 8
Distance Protection
Modeling CT and VT Models MHO-Characteristics Quadrilateral Characteristics X/R-Blinder Starting Characteristics Inter-Tripping Schemes Coordination R-X Diagrams Time-Distance Diagrams Simulation Steady State Time Domain
PowerFactory: Functions 9
Harmonics
Balanced and Unbalanced Harmonic Sources Characteristic, Non-Characteristic and Inter-Harmonics Frequency- and Time-Domain Charts Harmonic Loadflow Frequency Scan Frequency Dependent Line Parameters Distributed Parameter Line Models Filter Sizing
PowerFactory: Functions
10
Reliability
Weibul-Markov Failure Models Line/Transformer/Bus Bar Failures Common Mode Failures Double Earth Faults Circuit Breaker Failures Protection Failures Analytical State Enumeration Monte Carlo Simulation Advanced System Restoration Models including Generator Dispatch and Load Shedding
PowerFactory: Functions
11
PowerFactory: Functions
12