Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

608 750G

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

RECIRCULATING LOOP CHILLERS

MODEL............................................. PCP or POC-750G


DESCRIPTION Recirculating chillers recirculate a clean coolant at constant temperature and pressure to increase the stability and consistency of water cooled machines and instruments. Air cooled chillers eliminate the use of tap water and prevent clogging and corrosion of small diameter heat exchangers due to rust and scale build-up. PCP -Closed Loop Chillers: Use a storage type cooling tank, with immersion coil evaporator, to provide close temperature control of recirculating coolants. The tank is sealed to prevent coolant evaporation and fouling, and supplied with a liquid level gauge, ll port and clean out. The pump recirculates coolant at constant pressure and ow, which is adjustable by turning a manual bypass valve. POC - Open Loop Chillers: Pump liquid from an open tank or sump, through the chiller and back to the sump. An adjustable thermostat senses the make up liquid temperature, cycling the chiller to insure constant temperature in the sump.

HERMETIC SCROLL MODELS

TYPICAL CHILLER SHOWN APPLICATIONS


Jacket Cooling Lasers Induction Heaters Machine Tools Welders MRI Equipment CAT Scans Computers Power Supplies Vacuum Ovens Injection Molding Plasma Spraying Linear Accelerators Electron Microscopes

SPECIFICATIONS COOLING CAPACITY @ 68OF (20OC) Discharge & 90OF (32OC) Ambient
MODEL PCP or POC-750G-80 PCP or POC-750G-96 BTU/HR 80,000 96,000 WATTS 23.400 28,128 FULL LOAD AMPS @230 / 460 42 / 21 42 / 21

Energy Saving Design Unlike most process chillers, compressor runs only as needed. Storage design provides close temperature control and safety from freeze-up without constant operation. Complete Temperature Control Temperature adjustable within a range of 40O to 90OF (5O to 32OC) and will hold temperature within 1.5OF (1OC) of setting. (.5OF optional) Welded Stainless Steel Cooling Tank Recirculates clean coolant sealed from the atmosphere, eliminates bacterial build-up and internal corrosion. Uses HFC Refrigerant Eliminates use of ozone-depleting refrigerant as per Montreal Protocol. Design the perfect cooling system for any application. Over 50 options to meet almost any special need. Refer to Bulletin O & A.
WARRANTY All parts covered FOB jobsite for (12) months from start-up date or (15 months) from date of shipment - whichever comes rst. Some exceptions may apply... consult factory for details. START-UP and FIRST YEAR SERVICE AVAILABLE FILTRINE MFG CO can arrange start-up and first year service on all parts and labor. Regular maintenance, helping to prevent costly down time, is available on a contractual basis. FILTRINE IS ISO 9001-2001 REGISTERED PRODUCT LINE APPROVED MARK AVAILABLE

FEATURES

UNLIMITED OPTIONS

COMPRESSOR: HP........................................................................................................ 7.5 Lifetime lubricated, hermetic scroll type supplied with high/low pressure stat, freeze control, head and suction gauges, pump down solenoid valve, thermostatic expansion valve, refrigerant sight glass and dehydrator. STANDARD CONDENSERS (Designated by sux) A ..................Fan cooled condenser for indoor installation. AR ...............Remote Air cooled condenser furnished separately for mounting on roof. W ................Water cooled condenser for hookup to city or tower water A-WP .........Self-contained air cooled condenser; complete unit made weather-resistant for outdoor installation COOLING TANK & EVAPORATOR: Capacity ..................................... 95 gal (361 l) Welded stainless steel shell and immersion coil evaporator. Tank tested at 250# for 125# working pressure. Supplied with liquid level gauge and insulated with closed cell thermoelastomer with an R factor of 3.7. PUMP: HP ........................................................................................................................ 1.5 Capacity ....................................................................30 gpm (114 lpm) @ 40 PSI Stainless steel centrifugal pump mounted on rubber pads over a stainless steel condensation tray and supplied with unions and service valves and manually adjustable bypass valve. All piping and ttings brass, copper, or bronze and insulated with closed cell thermo-elastomer with an R factor of 3.7. THERMOSTAT: Adjustable Range .................................. 40O to 90OF (5O to 32OC) Temperature Stability ....................................................................... 1.5OF (1OC) CABINET: Enameled aluminum panels with stainless steel corner legs and top on a welded angle iron frame. Panels removable for access to all components. SUPPLY POWER: ......................................................... 208 - 230/60/3 or 460/60/3 PLUMBING CONNECTIONS IN & OUT .............................. 1-1/4" (31mm) MPT

FILTRINE Mfg Co 15 Kit St. Keene, NH 03431 USA 800-930-3367 603-352-5500 FAX 603-352-0330 WEB: www.filtrine.com EMAIL: cool@filtrine.com

608-7.5G (PCP-750G) REV. A 03.03.09

CHILLER DIMENSIONS and WEIGHTS


FILTRINE Model No. PCP or POC-750G-A PCP or POC-750G-W PCP or POC-750G-AR PCP or POC-750G-A-WP PCP or POC-750G-A-WP-LP* PCP or POC-750G-A-SSD** PCP or POC-750G-W-SSD** PCP or POC-750G-AR-SSD** W in 82 82 82 92 94 52 52 52 cm 208 208 208 234 238 132 132 132 in 39 30 30 39 87 32 32 32 D cm 99 76 76 99 221 81 81 81 in 70 60 60 70 44 80 82 82 H cm 178 152 152 178 112 203 208 208 2200 990 SHIP WT lb kg

STANDARD MODELS: Sux A, AR, W & AWP


1
2

3
4
9

LEFT END

FRONT W

10

* Low prole weather-resistant unit for rooftop installation ** Space Saving Design NOTE: Chiller dimensions and shipping wts. may vary depending on options - conrm with factory. LEGEND 1. Air Vent 7. To Remote Condenser (AR Models) 2. Fill Port Condenser Water Out (W Models) 3. Coolant Return 8. From Remote Condenser (AR Models) 4. Coolant Discharge Condenser Water In (W Models) 5. Control Panel 9. Electrical Connection 6. Gauges 10. Channel Skids VENTILATION PANELS Standard models: air intake at rear, air discharge at right end on A & WP models. REMOVABLE SERVICE PANELS Front & rear on all models CHANNEL SKIDS Channel skids project 2" (5 cm) front and rear. Center of mounting holes located 6" (15 cm) from chiller end and 1" (2.5 cm) from chiller edge front and rear. STANDARD OPERATING CONDITIONS OUTDOOR AMBIENT -20O to 100OF (-29O to 38OC) OPTIONAL OPERATING CONDITIONS OUTDOOR AMBIENT Up to 110OF (43OC) Up to to 120OF (49OC) Down to -30OF (-34OC) NOTE Higher ambient options may aect unit dimensions. NOTE Connections for remote condenser are at right end of chiller cabinet. REMOTE CONDENSER Use w/Standard or SSD Models - Furnished complete w/controls for operating in ambient temperatures to minus 20OF (-29OC); consult factory for specs. Connections for remote condenser are at right end of chiller cabinet. NOTE: Information given in this bulletin for general use only. Conrm exact specs with factory for your specic requirements.

D
NOTE: Manufacturer recommends 36 in. clearance at front for service and 18 in.clear space opposite all ventilation panels. NOTE: Allow an additional 4" to depth and 2" to height for channel skids. NOTE: Drawings are composites of various models to demonstrate plumbing locations. Conrm footprint with factory.

NEW -SSD MODEL: SPACE SAVING DESIGN


1
7
8

Suffix A, AR & W (AWP not available in SSD model)


6

NOTE: Manufacturer recommends 36 in. clearance at front for service and 18 in.clear space opposite all ventilation panels. NOTE: Allow an additional 4" to depth and 2" to height for channel skids. NOTE: Drawings are composites of various models to demonstrate plumbing locations. Conrm footprint with factory.

2
3
4
5
9

FRONT LEFT END


10

Kw 26.3

BTU 90,000 80,000 70,000 60,000 50,000 40,000 30,000 20,000 10,000 0

CHILLER CAPACITY
@ 90 F (32 C)
O O

MODEL 750G-96 750G-80

29.3 100,000

PUMP CAPACITY CHART


GPM at PRESSURE SHOWN PUMP MODEL STD-1.5C OP-2C OP-0.5T OP-0.75T psi ft 10 23 60 80 8 13 20 46 55 75 8 13 30 69 50 60 8 12 40 92 40 45 8 12 60 138 _ _ 8 11 80 184 _ _ 7 10 100 231 _ _ 6 8

23.4 20.5 17.6 14.6 11.7 8.8 5.9 2.9

Standard pump is 1 1/2 HP, centrifugal (C). Optional pumps (OP) include centrifugal or turbine (T) pumps. All turbine pumps include an adjustable pressure relief bypass in lieu of a manual bypass valve.

0O -18O

10O -12O

20O -7O

30O -1O

40O 4O

50O 10O

60O 16O

70OF 21OC

L - LOW TEMP RANGE

H - HIGH TEMP RANGE

FILTRINE Mfg Co 15 Kit St. Keene, NH 03431 USA 800-930-3367 603-352-5500 FAX 603-352-0330 WEB: www.filtrine.com EMAIL: cool@filtrine.com

608-7.5G (PCP-750G) REV. A 03.03.09

You might also like