SECTION 16130 BOXES

PART 1 - GENERAL 1 .1 RELATED DOCUMENTS

P A!N 16130 O"P #IE"N


P A!N 1 $ TO%NG QUA&T 1.1 TA'I LIE"U LIE"U QUAN

A.Provisions established within the General and Supplementary Conditions of the Contract, Division 1 - General e!uirements, the Specifications, "nstructions to #idders and the Drawin$s are collectively applicable to this Section. 1.2 A. REFERENCES A%S"&%'(A )# 1 * )ittin$s Supports for Conduit and Assemblies.

A. Ca7c 8ie9u :hoa;n thie<t la=p theo 8ie=n :ie=n bo> sun$ ? chun$ cu;a ho@Ap 8o9n$ pha9n 1 * Be@u ca9u chun$ 8aCc tDnh :yE thua=t, hFG7n$ daHn nhaI tha9u vaI ba;n veE 8FGAc F7n$ duAn$ thu tha=p tron$ muAc naIy. 1.2 T AM ( A)O A%S"&%'(A )# 1 - PhuA tuIn$ vaI trGA $iu7p o<n$ daHn vaI laJp ra7p ca7p A%S"&%'(A +S 1 * Ko=p 8a9u ra the7p, Ko=p duAn$ cuA, lG7p phu;, vaI cho<n$ 8GE ho=p A%S"&%)PA -. * Lie@u chua>n 8ie=n. )ederal Spec. /-C-012# * cho<n$ cha7y no> tha<m nFG7c CA&C CO*NG +IE"C #E" TR,N Ko=p

and A. Cable

#.

A%S"&%'(A +S 1 - Sheet-steel +utlet #. #o,es, Device #o,es, Covers, and #o, Supports. A%S"&%)PA Code. -. %ational 'lectrical C. D. 1. 3

C. D. 1. 3 A.

)ederal Spec. /-C-012# - ',plosionproof bo,es. SUBMITTALS Submit under specification

A. MFa ra ca7c co@n$ vie=c 8e= trNnh theo tho@n$ so< :yE thua=t #. Ghi nha=n vO trD chDnh ,a7c vaI $aJn 8o= cao 8a9u ra, 8a9u :e7o, vaI ho=p no<i. 1.4 CA&C YE*U CA!U #IE!U C -N

#. Accurately record actual locations and mountin$ hei$hts of outlet, pull, and 3unction bo,es. 1.4 A. -.. REGULATORY REQUIREMENTS Conform to re!uirements of A%S"&%)PA

A. Pa7c 8Onh 8u7n$ ye@u ca9u cu;a A%S"&%)PA -. #. Lran$ bO sa;n pha>m vaI pha@n loaAi theo thD n$hie=m thDch hGAp vG7i 8aCc tDnh 8FGAc chQ 8Onh 1.5 #IE!U (IE"N CO*NG TR,N #+P'S

#. )urnish products listed and classified by 4nderwriters 5aboratories, "nc. as suitable for purpose specified and shown. 1.5 A. PROJECT CONDITIONS 6erify field measurements are as shown

121R. - 1

on Drawin$s. #. 6erify locations of floor bo,es and outlets in offices and wor: areas prior to rou$h-in. C. 'lectrical bo,es are shown on Drawin$s in appro,imate locations unless dimensioned. "nstall at location re!uired for bo, to serve intended purpose. "nclude installation within R feet of location shown. PART 2 - PRODUCTS 2 .1 OUTLET BOXES

A. Wie>m tra phFGn$ pha7p sFA chDnh ,a7c 8FGAc the> hie=n tre@n ba;n veE. #. Pha@n loaAi vO trD ho=p saIn vaI loaAi ho=p taAi vaXn phoIn$ vaI :hu vFAc laIm vie=c trFG7c :hi laJp vaIo. C. $a9n ho=p ca7c nhau 6O trD ho=p 8ie=n tre@n ba;n veE nhF chDnh ,a7c trFI :Dch thFG7c. 5aJp 8u7n$ vO trD ye@u ca9u 8e> phuAc vuA muAc 8Dch dFA :ie<n. 5aJp moHi ca7ch R feet

P A!N 2 $ SA)N P A%M 2.1 O"P P A*N P O.I A%S"&%'(A

A. Ko=p 8a9u ra :im loaAi S +S 1, the7p maA :eEm

A. Sheet (etal +utlet #o,esS A%S"&%'(A +S 1, $alvaniTed steel. 1.)or masonry wallsS throu$h 2UU.

1.Mo<i vG7i tFGIn$ S :ie>u 2U0 * 2UU.

V.Ko=p 8a9u ra * Lo>n$ !ua7t S voIn$ $iaEn aco model 2U0 nG; co7 :Dch thFG7c vaI 8o= sa@u thDch hGAp, co7 ta<m phu; 8e> ba;o ve= thie<t bO. R. %haI tha9u seE 8e= trNnh ,in phe@ duye=t. #. Ko=p pha@n A%S"&%'(A +S V. pho<i %onmetallicS

V.+utlet #o, -GeneralS /ith e,tension rin$ of proper siTe and depth, with coverplate to match device cover. R. Contractor shall submit for approval #. %onmetallic +utlet #o,esS +S V. A%S"&%'(A

C. Ko=p 8u7c saYn %'(S )#1, :ie>u )D, feralloy 8u7c saYn. Cun$ ca<p mie<n$ 8e=m cho nhaI sa;n ,ua<t ho=p 8ie=n. Cun$ ca<p bo= no<i ren. D. Ko=p ra ba7o cha7yS 1.V.R , 1.V.R , 0R.U- mm co7 voIn$ $iaEn nGE n$an$. La<t ca; thie<t bO co7 :hun$ phaZn$ '. Ko=p 8a9u ra he= tho<n$ an toaInS ho=p 1.V.R , 1.V.R , 0R.U- mm co7 voIn$ $iaEn n$an$ o>@n. 2.2 O"P (E&O +A' O"P NO.I

C. Cast #o,esS %'(A )# 1, Lype )D, cast feralloy. Provide $as:eted cover by bo, manufacturer. Provide threaded hubs. D. )ire Alarm +utlet #o,esS 1.V.R , 1.V.R , 0R.U- mm bo, with sin$le $an$ e,tension rin$. All devices shall be flush mounted. '. Security System +utlet #o,esS 1.V.R , 1.V.R , 0R.U- mm. bo, with sin$le $an$ e,tension rin$. 2.2 PULL AND JUNCTION BOXES

A. Ko=p :im loaAi ta<m S %'(A +S 1, the7p maA :eEm. #.


121R. - 2

A. Sheet (etal #o,esS %'(A +S 1, $alvaniTed steel.

P6CS 45 0.1. #+P'S

#. C.

P6CS 45 0.1. SiTeS "n accordance with %'C.

C.

WDch thFG7c S theo %'C.

P A!N 3 $ T I CO*NG 3.1 LA/P #A0T

PART 3 - EXECUTION 3 .1 INSTALLATION

A. "nstall electrical bo,es as re!uired for splices, taps, wire pullin$, e!uipment connections and compliance with re$ulatory re!uirements. #. 5aJp ho=p 8ie=n 8e> ba;o trN phoIn$ chDnh vaI be9 maCt ma7y mo7c :Dn #. "nstall bo,es to maintain headroom and to C. ChQ laJp ho=p :e7o vaI ho=p no<i present neat mechanical appearance. tre@n tra9n tG7i 8FGAc vaI tre@n :hu vFAc chFa hoaIn thie=n C. "nstall pull bo,es and 3unction bo,es above D. Whu vFAc tra9n :ho@n$ tG7i 8FGAc S accessible ceilin$s and in unfinished areas laJp ho=p ra ho=p no<i :ho@n$ lG7n hGn 2 only. inch tFI panel 8e<n tra9n. D. "naccessible Ceilin$ AreasS "nstall outlet and 3unction bo,es no more than 2 inches from ceilin$ access panel. '. "nstall bo,es to preserve fire resistance ratin$ of partitions and other elements. ). 4se flush mountin$ outlet bo,es in finished areas. G. "nstall flush mountin$ bo, without dama$in$ wall insulation or reducin$ its effectiveness. K. Do not fasten bo,es to ceilin$ support wires. ". Support all 3unction bo,es independently of conduit, e,cept cast bo, that is connected to two ri$id metal conduits both supported within R.[.1 mm. of bo,. \. 4se $an$ bo, where more than one device is mounted to$ether. Do not use sectional bo,. W. 4se $an$ bo, with plaster rin$ for sin$le device outlets. '. 5aJp ho=p ba;o ve= cho<n$ cha7y cu;a va7ch n$aXn vaI ca7c va=t :ha7c ). DuIn$ ho=p 8a9u ra ba]n$ :huo@n tron$ :hu vFAc hoaIn thie=n G. 5aJp ho=p ba]n$ :huo@n laIm hF haAi maCt ca7ch tFGIn$ hay $ia;m tDnh hie=u !ua;. K. Who@n$ :ho7a ho=p 8e<n da@y 8ie=n tra9n. ". KoH trGA ta<t ca; ho=p no<i 8o=c la=p cu;a o<n$ daHn 8ie=n, trFI ho=p 8u7c saYn 8FGAc no<i vaIo V o<n$ daHn :im loaAi cF7n$, co7 :ha; naXn$ cho<n$ 8GEE tron$ ho=p R.[.1mm \. GaJn nhie9u duAn$ cuA vaIo maCt naA ho=p. Who@n$ duIn$ ho=p pha@n 8oaAn W. DuIn$ maCt naA ho=p co7 voIn$ tra7t vFEa cho 8a9u ra thie<t bO 8Gn. 5. DuIn$ ho=p 8a9u ra 8u7c saYn taAi vO trD n$oaIi 8e<n vO trD a>m FG7t vaI thGIi tie<t. (. Cho phe7p V.V0 inch R hay R2.1R cm &so< da@y daHn 1V vaIo moHi ho=p. %. Ko=p :e7o lG7n S ho=p :e7o lG7n hGn #+P'S

A. 5aJp ho=p 8ie=n theo ye@u ca9u cho phe7p, nha7nh reE :e7o da@y, :e<t no<i thie<t bO theo ye@u ca9u !uy 8Onh.

121R. - 3

5. 4se cast outlet bo, in e,terior locations e,posed to the weather and wet locations. (. Allow V.V0 cubic inches or R2.1- cubic centimeters&%o. 1V conductor in each bo,. %. 5ar$e Pull #o,esS #o,es lar$er than 1.. cubic inches or RV--.[ cubic centimeters in volume or R.[.1 mm. in any dimension. 1. "nterior Dry 5ocationsS enclosure as re!uired. 4se hin$ed

1.. inch hay RV--.[ cm R tron$ :ho<i lFGAn$ hay R.[.1 mm taAi ba<t :yI :Dch thFG7c naIo. 1. 6O trD :ho@ be@n tron$ S duIn$ :hG7p no<i 8o7n$ laAi. V. Ca7c vO trD :ha7c S duIn$ ho=p 8u7c $aJn vaIo be9 maCt 3.2 #IE!'U C -N

A. Mie9u chQnh 8a9u ra :hun$ ba]n$ phaZn$ 8e> laIm maCt trFG7c co7 tFGIn$ hoaIn thie=n hay va=t lie=u tra9n. #. 5aJp :noc:out 8Dnh :eIm vaIo ho=p. END OF SECTION

V. +ther 5ocationsS 4se surface mounted cast bo,es. 3.2 ADJUSTING

A. Ad3ust flush-mountin$ outlets to ma:e front flush with finished wall or ceilin$ material. #. "nstall :noc:out closure in unused bo, openin$ END OF SECTION

121R. - 4