Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Control Cable

Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)


Specification
:
SNI IEC 60502-1 : 2009

Constructions:
Conductor
Annealed plain copper round solid or round circular stranded
according to SNI IEC 60228

Outer Sheath
The Outer Sheath shall be a layer of Extruded Polyvinyl Chloride (PVC)
Grade ST1 to SNI IEC 60502-1. Black colour.

Insulation
Extruded layer of Polyvinyl Chloride (PVC) complied with
SNI IEC 60502-1
Colour :
- Black, with White printed number

Applications:
For indoor installation, in power and switching stations. As underground cable,
for difficult installation where the low weight is particularly advantageous.
Special Features on Request :
Fire Resistance Flame Retardant Cat. A/B/C Oil Resistance
UV Resistance Anti termite Anti rodent Low Smoke Zero Halogen

Inner Covering / filler


Extruded Polyvinyl Chloride (PVC), Black colour
Shield
Annealed copper wire with transverse helix of Annealed copper
tape

No. of Cores
and Cross
Section Area

Nominal
Nominal
Cross secThickness tion Area of Thickness
of Insulation Concentric of Outer
Sheath
Shield

Overall
Diameter
(approx)

Note : [re] Round solid conductor


[rm] Circular stranded conductor
Packing : [D] Drum

Current Carrying
Weight Min. Insulation
Capacity at 30C
of Cable DC. Resistance
at 20C
(approx)
In Ground
In Air

Short Circuit
Current
Capacity at
1.0 second

Standard
Delivery
Length

sq.mm

mm

sq.mm

mm

mm

kg/km

M.Ohm.km

kA

5 x 1.5 re/2.5

0.8

2.5

1.8

16.4

361

50

19

15

0.17

1000/D

5 x 1.5 rm/2.5

0.8

2.5

1.8

16.6

372

50

19

15

0.17

1000/D

7 x 1.5 re/2.5

0.8

2.5

1.8

17

407

50

17

13

0.17

1000/D

7 x 1.5 rm/2.5

0.8

2.5

1.8

17.6

441

50

17

13

0.17

1000/D

8 x 1.5 re/2.5

0.8

2.5

1.8

18

445

50

16

12

0.17

1000/D

8 x 1.5 rm/2.5

0.8

2.5

1.8

18.7

485

50

16

12

0.17

1000/D

10 x 1.5 re/2.5

0.8

2.5

1.8

20.1

542

50

15

11

0.17

1000/D

10 x 1.5 rm/2.5

0.8

2.5

1.8

20.9

592

50

15

11

0.17

1000/D

12 x 1.5 re/2.5

0.8

2.5

1.8

20.6

594

50

14

11

0.17

1000/D

12 x 1.5 rm/2.5

0.8

2.5

1.8

21.5

649

50

14

11

0.17

1000/D

14 x 1.5 re/2.5

0.8

2.5

1.8

21.4

647

50

13

10

0.17

1000/D

14 x 1.5 rm/2.5

0.8

2.5

1.8

22.3

710

50

13

10

0.17

1000/D

16 x 1.5 re/4

0.8

1.8

22.7

721

50

12

10

0.17

1000/D

16 x 1.5 rm/4

0.8

1.8

23.3

775

50

12

10

0.17

1000/D

19 x 1.5 re/4

0.8

1.8

23.2

784

50

12

0.17

1000/D

19 x 1.5 rm/4

0.8

1.8

24.3

865

50

12

0.17

1000/D

21 x 1.5 re/6

0.8

1.8

24.2

866

50

11

0.17

1000/D

21 x 1.5 rm/6

0.8

1.8

25.3

955

50

11

0.17

1000/D

24 x 1.5 re/6

0.8

1.8

25.8

958

50

11

0.17

1000/D

24 x 1.5 rm/6

0.8

1.8

27

1058

50

11

0.17

1000/D

30 x 1.5 re/6

0.8

1.8

27.7

1125

50

11

0.17

1000/D

30 x 1.5 rm/6

0.8

1.8

29

1247

50

11

0.17

1000/D

40 x 1.5 re/10

0.8

10

1.8

30.7

1417

50

11

0.17

1000/D

40 x 1.5 rm/10

0.8

10

1.8

32.2

1576

50

11

0.17

1000/D

52 x 1.5 re/10

0.8

10

1.9

34.8

1785

50

11

0.17

1000/D

52 x 1.5 rm/10

0.8

10

1.9

36.5

1988

50

11

0.17

1000/D

61 x 1.5 re/10

0.8

10

2.0

37

2025

50

11

0.17

1000/D

61 x 1.5 rm/10

0.8

10

2.0

38.7

2259

50

11

0.17

1000/D

sales@kabelindo.co.id

35

Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable

Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)


Specification
:
SNI IEC 60502-1 : 2009

Constructions:
Conductor
Annealed plain copper round solid or round circular stranded
according to SNI IEC 60228

Outer Sheath
The Outer Sheath shall be a layer of Extruded Polyvinyl Chloride (PVC)
Grade ST1 to SNI IEC 60502-1. Black colour.

Insulation
Extruded layer of Polyvinyl Chloride (PVC) complied with
SNI IEC 60502-1
Colour :
- Light Blue, Brown

Applications:
Indoor, in ducts, in the open, underground, if mechanical damage is
not expected.
Special Features on Request :
Fire Resistance Flame Retardant Cat. A/B/C Oil Resistance
UV Resistance Anti termite Anti rodent Low Smoke Zero Halogen

Inner Covering / filler


Extruded Polyvinyl Chloride (PVC), Black colour
Shield
Annealed copper wire with transverse helix of Annealed copper
tape

No. of Cores
and Cross
Section Area

Nominal
Nominal
Cross secThickness tion Area of Thickness
of Insulation Concentric of Outer
Sheath
Shield

Overall
Diameter
(approx)

Note : [re] Round solid conductor


[rm] Circular stranded conductor
Packing : [D] Drum

Current Carrying
Weight Min. Insulation
Capacity at 30C
of Cable DC. Resistance
at 20C
(approx)
In Ground
In Air

Short Circuit
Current
Capacity at
1.0 second

Standard
Delivery
Length

sq.mm

mm

sq.mm

mm

mm

kg/km

M.Ohm.km

kA

2 x 1.5 re/1.5

0.8

1.5

1.8

13.5

230

50

27

21

0.17

1000/D

2 x 1.5 rm/1.5

0.8

1.5

1.8

13.9

242

50

27

21

0.17

1000/D

2 x 2.5 re/2.5

0.8

2.5

1.8

14.5

281

50

36

29

0.29

1000/D

2 x 2.5 rm/2.5

0.8

2.5

1.8

16.2

290

50

36

29

0.29

1000/D

2 x 4 re/4

1.0

1.8

16.8

370

50

47

38

0.46

1000/D

2 x 4 rm/4

1.0

1.8

17.2

395

50

47

38

0.46

1000/D

2 x 6 re/6

1.0

1.8

17.8

454

50

59

48

0.69

1000/D

2 x 6 rm/6

1.0

1.8

18.1

485

50

59

48

0.69

1000/D

2 x 10 re/10

1.0

10

1.8

19.8

635

50

78

66

1.15

1000/D

2 x 10 rm/10

1.0

10

1.8

20.2

658

50

78

66

1.15

1000/D

2 x 16 rm/16

1.0

16

1.8

22

891

40

102

90

1.84

1000/D

2 x 25 rm/16

1.2

16

1.8

25.6

1207

40

134

120

2.88

1000/D

2 x 35 rm/16

1.2

16

1.8

27.8

1476

40

180

150

4.03

1000/D

2 x 50 rm/25

1.4

25

1.9

31.3

1928

30

210

180

5.75

1000/D

2 x 70 rm/35

14

35

2.0

35.8

2605

30

260

230

8.05

1000/D

2 x 95 rm/50

1.6

50

2.2

40.4

3557

30

315

280

10.93

1000/D

2 x 120 rm/70

1.6

70

2.3

43.6

4376

30

320

320

13.80

1000/D

2 x 150 rm/70

1.8

70

2.4

48.5

5208

20

355

375

17.25

500/D

2 x 185 rm/95

2.0

95

2.6

53.8

6546

20

409

430

21.28

500/D

2 x 240 rm/120

2.2

120

2.8

60.6

8368

20

472

510

27.60

500/D

2 x 300 rm/150

2.4

150

3.0

67.5

10385

20

525

590

34.50

500/D

32

www.kabelindo.co.id

Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Control Cable

Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)


Specification
:
SNI IEC 60502-1 : 2009

Constructions:
Conductor
Annealed plain copper round solid or round circular stranded
according to SNI IEC 60228

Outer Sheath
The Outer Sheath shall be a layer of Extruded Polyvinyl Chloride (PVC)
Grade ST1 to SNI IEC 60502-1. Black colour.

Insulation
Extruded layer of Polyvinyl Chloride (PVC) complied with
SNI IEC 60502-1
Colour :
-Black, with White printed number

Applications:
For indoor installation, in power and switching stations. As underground cable,
for difficult installation where the low weight is particularly advantageous.
Special Features on Request :
Fire Resistance Flame Retardant Cat. A/B/C Oil Resistance
UV Resistance Anti termite Anti rodent Low Smoke Zero Halogen

Inner Covering / filler


Extruded Polyvinyl Chloride (PVC), Black colour
Shield
Annealed copper wire with transverse helix of Annealed copper
tape

No. of Cores
and Cross
Section Area

Nominal
Nominal
Cross secThickness tion Area of Thickness
of Insulation Concentric of Outer
Sheath
Shield

Overall
Diameter
(approx)

Note : [re] Round solid conductor


[rm] Circular stranded conductor
Packing : [D] Drum

Current Carrying
Weight Min. Insulation
Capacity at 30C
of Cable DC. Resistance
at 20C
(approx)
In Ground
In Air

Short Circuit
Current
Capacity at
1.0 second

Standard
Delivery
Length

sq.mm
5 x 2.5 re/2.5

mm
0.8

sq.mm
2.5

mm
1.8

mm
17.5

kg/km
432

M.Ohm.km
50

A
26

A
21

kA
0.29

m
1000/D

5 x 2.5 rm/2.5

0.8

2.5

1.8

17.8

453

50

26

21

0.29

1000/D

7 x 2.5 re/2.5

0.8

2.5

1.8

18.1

514

50

23

18

0.29

1000/D

7 x 2.5 rm/2.5

0.8

2.5

1.8

18.9

564

50

23

18

0.29

1000/D

8 x 2 5 re/2.5

0.8

2.5

1.8

19.3

565

50

21

17

0.29

1000/D

8 x 2.5 rm/2.5

0.8

2.5

1.8

20.2

620

50

21

17

0.29

1000/D

10 x 2.5 re/4

0.8

1.8

21.6

672

50

20

16

0.29

1000/D

10 x 2.5 rm/4

0.8

1.8

22.7

741

50

20

16

0.29

1000/D

12 x 2.5 re/4

0.8

1.8

22.2

743

50

18

15

0.29

1000/D

12 x 2.5 rm/4

0.8

1.8

23.3

822

50

18

15

0.29

1000/D

14 x 2.5 re/6

0.8

1.8

23.1

818

50

17

14

0.29

1000/D

14 x 2.5 rm/6

0.8

1.8

24.3

907

50

17

14

0.29

1000/D

16 x 2.5 re/6

0.8

1.8

24.5

914

50

17

13

0.29

1000/D

16 x 2.5 rm/6

0.8

1.8

25.4

997

50

17

13

0.29

1000/D

19 x 2.5 re/6

0.8

1.8

25.2

1007

50

16

13

0.29

1000/D

19 x 2 5 rm/6

0.8

1.8

26.5

1122

50

16

13

0.29

1000/D

21 x 2.5 re/10

0.8

10

1.8

26.4

1153

50

15

12

0.29

1000/D

21 x 2.5 rm/10

0.8

10

1.8

27.8

1281

50

15

12

0.29

1000/D

24 x 2.5 re/10

0.8

10

1.8

28.1

1278

50

14

11

0.29

1000/D

24 x 2.5 rm/10

0.8

10

1.8

29.7

1338

50

14

11

0.29

1000/D

30 x 2.5 re/10

0.8

10

1.8

30.3

1510

50

14

11

0.29

1000/D

30 x 2.5 rm/10

0.8

10

1.8

32

1687

50

14

11

0.29

1000/D

40 x 2.5 re/10

0.8

10

1.8

34.1

1917

50

14

11

0.29

1000/D

40 x 2.5 rm/10

0.8

10

1.8

36.1

2145

50

14

11

0.29

1000/D

52 x 2.5 re/10

0.8

10

1.9

38.4

2402

50

14

11

0.29

1000/D

52 x 2.5 rm/10

0.8

10

1.9

40.7

2694

50

14

11

0.29

1000/D

61 x 2.5 re/10

0.8

10

2.0

40.5

2716

50

14

11

0.29

1000/D

61 x 2.5 rm/10

0.8

10

2.0

43

3053

50

14

11

0.29

1000/D

36

www.kabelindo.co.id

Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable

Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)


Specification
:
SNI IEC 60502-1 : 2009

Constructions:
Conductor
Annealed plain copper round solid or round circular stranded
according to SNI IEC 60228

Outer Sheath
The Outer Sheath shall be a layer of Extruded Polyvinyl Chloride (PVC)
Grade ST1 to SNI IEC 60502-1. Black colour.

Insulation
Extruded layer of Polyvinyl Chloride (PVC) complied with
SNI IEC 60502-1
Colour :
- Yellow Strip Green, Light Blue and Brown
- Brown, Black And Grey

Applications:
Indoor, in ducts, in the open, underground, if mechanical damage is
not expected.
Special Features on Request :
Fire Resistance Flame Retardant Cat. A/B/C Oil Resistance
UV Resistance Anti termite Anti rodent Low Smoke Zero Halogen

Inner Covering / filler


Extruded Polyvinyl Chloride (PVC), Black colour
Shield
Annealed copper wire with transverse helix of Annealed copper
tape
No. of Cores
and Cross
Section Area

Nominal
Nominal
Cross secThickness tion Area of Thickness
of Insulation Concentric of Outer
Sheath
Shield

Overall
Diameter
(approx)

Note : [re] Round solid conductor


[rm] Circular stranded conductor
[Sm] Sector shape conductorPacking
Packing : [D] Drum
Current Carrying
Weight Min. Insulation
Capacity at 30C
of Cable DC. Resistance
at 20C
In Ground
(approx)
In Air

Short Circuit
Current
Capacity at
1.0 second

Standard
Delivery
Length

sq.mm
3x 1.5 re/1.5

mm
0.8

sq.mm
1.5

mm
1.8

mm
14.1

kg/km
260

M.Ohm.km
50

A
24

A
18

kA
0.17

m
1000/D

3 x 1.5 rm/1.5

0.8

1.5

1.8

14.4

271

50

24

18

0.17

1000/D

3 x 2.5 re/2.5

0.8

2.5

1.8

14.9

322

50

32

25

0.29

1000/D

3 x 2.5 rm/2.5

0.8

2.5

1.8

15.5

339

50

32

25

0.29

1000/D

3 x 4 re/4

1.0

1.8

16.9

427

50

41

34

0.46

1000/D

3 x 4 rm/4

1.0

1.8

17.5

456

50

41

34

0.46

1000/D

3 x 6 re/6

1.0

1.8

18.2

535

50

52

44

0.69

1000/D

3 x 6 rm/6

1.0

1.8

19.1

568

50

52

44

0.69

1000/D

3 x 10 re/10

1.0

10

1.8

20.9

759

50

69

60

1.15

1000/D

3 x 10 rm/10

1.0

10

1.8

21.3

787

50

69

60

1.15

1000/D

3 x 16 rm/16

1.0

16

1.8

23.2

1068

40

89

80

1.84

1000/D

3 x 25 rm/16

1.2

16

1.8

26.8

1476

40

116

105

2.88

1000/D

3 x 35 rm/16

1.2

16

1.8

29.5

1438

40

138

130

4.03

1000/D

3 x 50 sm/25

1.4

25

1.9

29.7

2216

30

165

160

5.75

1000/D

3 x 70 sm/35

1.4

35

2.0

32.4

2985

30

205

200

8.05

1000/D

3 x 95 sm/50

1.6

50

2.2

36.6

4065

30

245

245

10.93

1000/D

3 x 120 sm/70

1.6

70

2.3

40.2

5073

30

285

285

13.80

1000/D

3 x 150 sm/70

1.8

70

2.4

43.7

6082

20

315

325

17.25

500/D

3 x 185 sm/95

2.0

95

2.6

49.4

7516

20

355

370

21.28

500/D

3 x 240 sm/120

2.2

120

2.8

54.8

9768

20

415

435

27.60

500/D

3 x 300 sm/150

2.4

150

3.0

61.3

12186

20

465

500

34.50

500/D

sales@kabelindo.co.id

33

Copper Conductor PVC Insulated, Concentric Copper wire Screened & PVC Sheathed Power Cable

Cu/PVC/CWS/PVC 0.6/1 kV (NYCY)


Specification
:
SNI IEC 60502-1 : 2009

Constructions:
Conductor
Annealed plain copper round solid or round circular stranded
according to SNI IEC 60228

Outer Sheath
The Outer Sheath shall be a layer of Extruded Polyvinyl Chloride (PVC)
Grade ST1 to SNI IEC 60502-1. Black colour.

Insulation
Extruded layer of Polyvinyl Chloride (PVC) complied with
SNI IEC 60502-1
Colour :
- Yellow Strip Green, Brown, Black and Grey
- Light Blue, Brown, Black And Grey

Applications:
Indoor, in ducts, in the open, underground, if mechanical damage
is not expected.
Special Features on Request :
Fire Resistance Flame Retardant Cat. A/B/C Oil Resistance
UV Resistance Anti termite Anti rodent Low Smoke Zero Halogen

Inner Covering / filler


Extruded Polyvinyl Chloride (PVC), Black colour
Shield
Annealed copper wire with transverse helix of Annealed copper
tape
No. of Cores
and Cross
Section Area

Nominal
Nominal
Cross secThickness tion Area of Thickness
of Insulation Concentric of Outer
Sheath
Shield

Overall
Diameter
(approx)

Note : [re] Round solid conductor


[rm] Circular stranded conductor
[Sm] Sector shape conductor
Packing : [D] Drum
Current Carrying
Weight Min. Insulation
Capacity at 30C
of Cable DC. Resistance
at 20C
(approx)
In Ground
In Air

Short Circuit
Current
Capacity at
1.0 second

Standard
Delivery
Length

sq.mm

mm

sq.mm

mm

mm

kg/km

M.Ohm.km

kA

4 x 1.5 re/1.5

0.8

1.5

1.8

14.7

236

50

24

18

0.17

1000/D

4 x 1.5 rm/1.5

0.8

1.5

1.8

15.2

249

50

24

18

0.17

1000/D

4 x 2.5 re/2.5

0.8

2.5

1.8

15.8

303

50

32

25

0.29

1000/D

4 x 2.5 rm/2.5

0.8

2.5

1.8

16.4

324

50

32

25

0.29

1000/D

4 x 4 re/4

1.0

1.8

18.1

428

50

41

34

0.46

1000/D

4 x 4 re/4

1.0

1.8

18.9

457

50

41

34

0.46

1000/D

4 x 6 re/6

1.0

1.8

19.3

546

50

52

44

0.69

1000/D

4 x 6 rm/6

1.0

1.8

20.2

585

50

52

44

0.69

1000/D

4 x 10 re/10

1.0

10

1.8

22.7

789

50

69

60

1.15

1000/D

4 x 10 rm/10

1.0

10

1.8

22.3

817

50

69

60

1.15

1000/D

4 x 16 rm/16

1.0

16

1.8

25.3

1155

40

89

80

1.84

1000/D

4 x 25 rm/16

1.2

16

1.8

29.2

1648

40

116

105

2.88

1000/D

4 x 35 rm/16

1.2

16

1.8

31.8

2095

40

138

130

4.03

1000/D

4 x 50 sm/25

1.4

25

2.0

33.7

2664

30

165

160

5.75

1000/D

4 x 70 sm/35

1.4

35

2.1

40.2

3573

30

205

200

8.05

1000/D

4 x 95 sm/50

1.6

50

2.3

42.6

4880

30

245

245

10.93

1000/D

4 x 120 sm/70

1.6

70

2.4

47.4

6153

30

285

285

13.80

1000/D

4 x 150 sm/70

1.8

70

2.6

50.6

7377

20

315

325

17.25

500/D

4 x 185 sm/95

2.0

95

2.8

57.5

9195

20

355

370

21.28

500/D

4 x 240 sm/120

2.2

120

3.0

63.8

11865

20

415

435

27.60

500/D

4 x 300 sm/150

2.4

150

3.2

71.6

14420

20

465

500

34.50

500/D

34