measuring

Low Volume
Rotating Vane Flow Meter

monitoring

for Liquids

analysing

DPL
Model: DPL

Measuring ranges:
0.025- 0.5...1-25 L/min water
Linearity: 1%
pmax: 10 bar; tmax: 70 C
Viscosity range: low viscosity
Connection: G male, hose connector
Material of case: PP
Model: DPL with
pointer indication

Output: pulse
without magnets or metal parts
Medium: infrared light transmissive

Model: DPL with


compact electronics

1/11- 2013

KOBOLD companies worldwide:

ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLUMBIA, CZECHIA,


DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE,
SOUTH KOREA, SPAIN, SWITZER-LAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM

KOBOLD Messring GmbH


Nordring 22-24
D-65719 Hofheim/Ts.
Head Office:
+49(0)6192 299-0
+49(0)6192 23398
info.de@kobold.com
www.kobold.com
1

Low Volume Rotating Vane Flow Meter Typ DPL

Application
The KOBOLD ow meters model DPL are used to measure
and monitor liquids. Its compact design allows it to be used
in equipment where space is at a premium. The large number
of pulse evaluation options offered means that the system is
suited for a wide range of applications.

Frequency output (option frequency divider)


Power supply:
24 VDC 20%
Supply current:
40 - 50 mA
Signal amplitude high: approx. power supply
Signal amplitude low:
0.2 V
Output loss:
max. 2.5 mWatt
Electrical connection:
plug M12x1
(option: 2 m PVC cable)
Division ratio (option): 1...1128 factory set
Pulse output:
PNP, open collector,
max. 20 mA

Technical details
Accuracy:

2,5% of full scale


5% of full scale (OEM version)
Linearity:
1% of full scale
Medium temperature:
-40 ... +70 C
Ambient temperature: -30 ... +60 C
Max. operating pressure: 10 bar
Protection:
IP 65

Analogue output (option plug-on display)


Power supply:
24 VDC 20%
Output:
0-20 mA or 4-20 mA,
3-wire technology
Max. Brde:
500
Electrical connection:
plug connector M12x1 or
DIN 43 650
Option:
plug-on display (with plug
connector DIN 43 650 only)
Compact electronics
Display:
Analogue output:
Switching outputs:

polypropylene
polypropylene
sapphire
polysulfone
NBR, FPM or EPDM

Contact operation:
Setting:
Power supply:
Electrical connection:

Operating principles
The medium ows through a specially shaped ow housing
and causes a vane to rotate. This rotary motion is sensed by
optoelectronics in a non-contacting manner, and converted
to an asymmetric frequency signal or an analogue signal. A
frequency divider with symmetrical output is available as an
option. The frequency is proportional to the ow velocity.
The vane is sapphire-supported: this ensures a high degree
of linearity and long service life.

3-position LED
(0)4...20 mA adjustable,
max. 500
1 (2) semiconductor PNP or
NPN, set at the factory
programmable N/C/ N/O contact
via 2 buttons
24 VDC 20%, approx. 100 mA,
3-wire technology
plug connector M12x1

Pointer indication with analogue output


Housing:
aluminium (PA6 GF30)
Display:
moving coil instrument,
240 display
Power supply:
24 VDC 20%
Output:
(0)4...20 mA, set at the
factory, 3-wire technology
Max. load:
250
Electrical connection:
plug connector M12x1

www.kobold.com

No responsibility taken for errors;


subject to change without prior notice.

1/11- 2013

Areas of application:
low viscosity liquids
non-conductive liquids
volume dosing with external electronics
lter aid
beverage industry

Materials:
Housing:
Rotating vane:
Axle/bearing:
Vane mount:
Gasket:

Electronics
Frequency output (OEM without CE-Sign)
Power supply:
4.5 - 12 VDC
Supply current:
typ. 7 mA
Signal amplitude high: approx. power supply
Signal amplitude low:
0.2 V
Transmitter cut-off
voltage:
3 V max.
Transmitter supply
current:
10 - 12 mA
Output loss:
max. 2.5 mWatt
Electrical connection:
solder pins
Pulse output:
NPN, Open Collect., max.10 mA

Low Volume Rotating Vane Flow Meter Typ DPL

Order Details (Example: DPL-1P05 G4 0000)


Meas.
range
[l/min]
water

approx.
approx.
frequency pressure
[Hz] at
[bar] at
max. value max. value

Gasket model
NBR

FPM

Connection

EPDM

0,025 - 0,5

272

0,77

DPL-1P05 DPL-1V05 DPL-1E05

0,05 - 1,8

471

0,77

DPL-1P10 DPL-1V10 DPL-1E10

G4..=
G male
S4..=
DPL-1P15 DPL-1V15 DPL-1E15 Hose
connector
(for inner of
hose 12 mm
+ 14 mm)

0,2 - 6

505

0,70

0,4 - 12

265

1,0

DPL-1P20 DPL-1V20 DPL-1E20

1 - 25

399

1,3

DPL-1P25 DPL-1V25 DPL-1E25

Electronic analyser

Frequency output
..0000 = Frequency output, NPN,
without cable (OEM), no CE
..F300 = Frequency output, plug M12x1, PNP
..F320 = Frequency divider 1:2, plug M12x1, PNP
..F340 = Frequency divider 1:4, plug M12x1, PNP
..F390 = Freq. divider 1...1/128, plug M12x1, PNP
..F500 = Frequency output, PNP, 2 m PVC cable
..F520 = Frequency divider 1:2,
2 m PVC cable, PNP
..F540 = Frequency divider 1:4,
2 m PVC cable, PNP
..F590 = Freq. divider 1...1/128, 2 m PVC cable, PNP
Analogue output
..L303 = 0-20 mA output, M12x1 plug
..L343 = 4-20 mA output, M12x1 plug
..L403 = 0-20 mA output, plug DIN 43 650
..L443 = 4-20 mA output, plug DIN 43 650
Compact electronics*
..C3R = LED display, 2x open collector, PNP,
plug M12x1
..C30M = LED display, 2x open collector, NPN,
plug M12x1
..C34P = LED display, 4-20 mA, 1x open collector,
PNP, plug M12x1
..C34N = LED display, 4-20 mA, 1x open collector
NPN, plug M12x1
Pointer indication*
..Z300 = 240 pointer indication, 0-20 mA,
plug M12x1
..Z340 = 240 pointer indication, 4-20 mA,
plug M12x1

* Please specify ow direction in writing

Plug-on display
for model DPL...L443... (with 4 -20 mA output and DIN plug connector)
Description

Order number

4-position LED, plug connector DIN 43 650,


3-wire, power supply through analogue output

AUF-3000

Electrical connection
DPL..0000

DPL..L3 / DPL..Z / DPL..F3

DPL..C

DPL..L4
2 GND

Signal
+UB
Sender

nc

+ Vs
1

GND

+UB

(0)4-20 mA

+ Vs

switch out 2
GND

Signal
out

GND

1
5

3 out 4-20 mA
Switch out 1

1 + Vs

1/11 - 2013

DPL...F5...
brown: +Vs
blue: GND
black: signal

No responsibility taken for errors;


subject to change without prior notice.

www.kobold.com

Low Volume Rotating Vane Flow Meter Typ DPL

Dimensions

DPL-...F3..; DPL-...L3...

DPL-...C with compact electronics

32

86,4

32

102,7

23,7

DPL-...0000

32

1
13

24 AF
SW
24
1
13

1
13

24
SWAF
24

24
SWAF
24

75

1
13

1
13

75

DPL-...L4... with analogue output and plug-on display

75

DPL-...Z with analogue output and pointer indication

79.7

32

32

1
13

G
24
SWAF
24
1
13

www.kobold.com

75