Static Characteristics of Measurement
Static Characteristics of Measurement
Static Characteristics of Measurement
characteristics of Instruments
Characteristics of
measurement systems
To choose the one most suited to a particular
measurement application, we have to know
the system characteristics.
The performance characteristics may be
broadly divided into two groups, namely
static and dynamic characteristics
Static characteristics
the performance criteria for the measurement
of quantities that remain constant, or vary only
quite slowly.
Dynamic characteristics
the relationship between the system input and
output when the measured quantity
(measurand) is varying rapidly.
In practice, the characteristics of the one group may well
influence the characteristics of the other. In order to access
overall instrument performance, however, the two groups of
characteristics are normally studied separately and then a
semi-quantitative superposition is carried out.
1. Accuracy
This is the closeness with which the measuring
instrument can measure the true value of the
measurand under stated conditions of use, i.e. its
ability to tell the truth.
The accuracy of an instrument is quantified by the
difference of its readings and the one given by the
ultimate or primary standard.
2. Precision
Precision is defined as the ability of instrument to
reproduce a certain set of readings within given
accuracy.
Precision describes an instruments degree of
random variations in its output when measuring a
constant quantity.
Precision depends upon repeatability.
3. Repeatability
Repeatability is defined as ability of instrument to
reproduce a group of measurements of same
measured quantity, made by same observer, using
same instrument, under same conditions.
Precision
Precision represents degree
of repeatability of several
independent measurements
of desired input at the same
reference conditions
Precision of instruments
depends on factors that
cause random or accidental
errors.
High
precision,
low
accuracy
High
precision,
High
accuracy
4. Resolution (Discrimination)
It is the minimum change or smallest increment in
the measured value that can be detected with
certainty by the instrument.
It can be least count of instrument.
6. Tolerance
- Tolerance is a term that is closely related to
accuracy and defines the maximum error that
is to be expected in some value.
- Tolerance describes the maximum deviation of
a manufactured component from some
specified value
7. Range or span
- The range or span of an instrument defines the
minimum and maximum values of a quantity
that the instrument is designed to measure.
8. Linearity
This is the closeness to a straight line
of the relationship between the
true process variable and the
measurement.
i.e. deviation of transducer output
curve from a specified straight line.
1. Independent of Input
2. Proportional to Input
3. Combined independent &
proportional to Input.
Linearity is usually reported as non-linearity, which is the maximum of
the deviation between the calibration curve and a straight line
positioned so that the maximum deviation is minimized.
9. Sensitivity of measurement
The sensitivity of measurement is a measure of the change in
instrument output that occurs when the quantity being
measured changes by a given amount. Thus, sensitivity
is the ratio:
Static Sensitivity K = Change of Output Signal
Change in Input Signal
qi
qo
10. Reliability
Reliability is the probability that a device will adequately
perform (as specified) for a period of time under specified
operating conditions. Some sensors are required for safety or
product quality, and therefore, they should be very reliable.
12. Hysteresis
Careful observation of the output/input relationship of a block will
sometimes reveal different results as the signals vary in direction of
the movement.
Mechanical systems will often show a small difference in length as
the direction of the applied force is reversed.
The same effect arises as a magnetic field is reversed in a magnetic
material.
This characteristic is called hysteresis.
Hysteresis is defined as the magnitude of error caused in the output
for a given value of input, when this value is approached from
opposite directions ; i.e. from ascending order & then descending
order.
Causes are backlash, elastic deformations, magnetic characteristics,
frictional effects (mainly).
Hysteresis can be eliminated by taking readings in both direction and
then taking its arithmetic mean.
13. Backlash
It is defined as the maximum distance or angle
through which any part of mechanical system may be
moved in one direction without causing motion of
next part.
Can be minimized if components are made to very
close tolerances.