ABC Moments in The Beams As Shown in Figure 1 Below.: Plastic Centroid. A A A Plastic Centroid. A A A
ABC Moments in The Beams As Shown in Figure 1 Below.: Plastic Centroid. A A A Plastic Centroid. A A A
ABC Moments in The Beams As Shown in Figure 1 Below.: Plastic Centroid. A A A Plastic Centroid. A A A
Varma
V(x)
M(x)
Figure 1. Internal shear force and bending moment diagrams for transversely loaded beams.
These internal shear forces and bending moments cause longitudinal axial stresses and shear
Figure 4. Section Moment - Curvature (M-) behavior.
the shape factor f for the section.
For a rectangular section, f is equal to 1.5. For a wide-flange section, f is equal to 1.1.
Calculation of Mp: Cross-section subjected to either +y or -y at the plastic limit. See Figure
5 below.
y
Plastic centroid.
A1
y1
A2
y A 2
y A 1
y2
A1 A
y
(a) General cross-section
F y A1
Where , y
y
A1
y1
A2
y A 1
y2
y A 2
F y A1 y A 2 0
A1 A 2 A / 2
A
( y1 y 2 )
2
Where , y1 centroid of A1
M y
y 2 centroid of A 2
(d) Equations
Figure 5. Plastic centroid and Mp for general cross-section.
The plastic centroid for a general cross-section corresponds to the axis about which the total
area is equally divided, i.e., A1 = A2 = A/2
The plastic centroid is not the same as the elastic centroid or center of gravity (c.g.) of the
cross-section.
As shown below, the c.g. is defined as the axis about which A1y1 = A2y2.
y2
A 1, y 1
y1
c.g. = elastic N.A. A , y
2 2
For a cross-section with at-least one axis of symmetry, the neutral axis corresponds to the
centroidal axis in the elastic range. However, at Mp, the neutral axis will correspond to
the plastic centroidal axis.
For a doubly symmetric cross-section, the elastic and the plastic centroid lie at the same
point.
Mp = y x A/2 x (y1+y2)
As shown in Figure 5, y1 and y2 are the distance from the plastic centroid to the centroid of
area A1 and A2, respectively.
A/2 x (y1+y2) is called Z, the plastic section modulus of the cross-section. Values for Z are
tabulated for various cross-sections in the properties section of the LRFD manual.
Mp = 0.90 Z Fy
where,
Mp = plastic moment
My = moment corresponding to onset of yielding at the extreme fiber from an elastic stress
distribution = Fy S for homogenous cross-sections and = Fyf S for hybrid sections.
Z = plastic section modulus from the Properties section of the AISC manual.
S = elastic section modulus, also from the Properties section of the AISC manual.
Example 2.1 Determine the elastic section modulus, S, plastic section modulus, Z, yield
moment, My, and the plastic moment Mp, of the cross-section shown below. What is the design
moment for the beam cross-section. Assume 50 ksi steel.
12 in.
F1
0.75 in.
16 in.
W t = 0.5 in.
w
F2
1.0 in.
15 in.
31.125
15.5625
2
y p 2.125 in.
in.
Zx = A/2 x (y1 + y2) = 15.5625 x (10.5746 + 1.5866) = 189.26 in3
Mp-x = Zx Fy = 189.26 x 50 = 9462.93 kip-in. = 788.58 kip-ft.
Design strength according to AISC Chapter F= bMp= 0.9 x 788.58 = 709.72 kip-ft.
Mp, the plastic moment capacity for the steel shape, is calculated by assuming a plastic stress
distribution (+ or - y) over the cross-section.
The development of a plastic stress distribution over the cross-section can be hindered by two
different length effects:
(1) Local buckling of the individual plates (flanges and webs) of the cross-section before
they develop the compressive yield stress y.
(2) Lateral-torsional buckling of the unsupported length of the beam / member before
the cross-section develops the plastic moment Mp.
The analytical equations for local buckling of steel plates with various edge conditions and
the results from experimental investigations have been used to develop limiting slenderness
ratios for the individual plate elements of the cross-sections.
Steel sections are classified as compact, non-compact, or slender depending upon the
slenderness () ratio of the individual plates of the cross-section.
If p, then the individual plate element can develop and sustain y for large values of
before local buckling occurs.
If p r, then the individual plate element can develop y but cannot sustain it
before local buckling occurs.
If r , then elastic local buckling of the individual plate element occurs.
Compact
Non-Compact
Slender
Figure 8. Stress-strain response of plates subjected to axial compression and local buckling.
Thus, slender sections cannot develop M p due to elastic local buckling. Non-compact
sections can develop My but not Mp before local buckling occurs. Only compact sections can
develop the plastic moment Mp.
7
All rolled wide-flange shapes are compact with the following exceptions, which are noncompact.
-
W40x174, W14x99, W14x90, W12x65, W10x12, W8x10, W6x15 (made from A992)
The definition of and the values for p and r for the individual elements of various crosssections are given in Table B5.1 and shown graphically on page 16.1-183. For example,
Section
Wide-flange
Channel
Square or Rect.
Box
Plate element
Flange
Web
Flange
Web
Flange
Web
bf/2tf
h/tw
bf/tf
h/tw
(b-3t)/t
(b-3t)/t
p
0.38
3.76
0.38
3.76
1.12
3.76
E / Fy
E / Fy
E / Fy
E / Fy
E / Fy
E / Fy
r
0.38
5.70
0.38
5.70
1.40
5.70
E / FL
E / Fy
E / FL
E / Fy
E / Fy
E / Fy
In CE470 we will try to design all beam sections to be compact from a local buckling
standpoint
(a)
M
(b)
M
M
Lateral-torsional buckling is fundamentally similar to the flexural buckling or flexuraltorsional buckling of a column subjected to axial loading.
-
The differences are that lateral-torsional buckling is caused by flexural loading (M), and
the buckling deformations are coupled in the lateral and torsional directions.
There is one very important difference. For a column, the axial load causing buckling
remains constant along the length. But, for a beam, usually the lateral-torsional buckling
causing bending moment M(x) varies along the unbraced length.
The worst situation is for beams subjected to uniform bending moment along the
unbraced length. Why?
Consider a beam that is simply-supported at the ends and subjected to four-point loading as
shown below. The beam center-span is subjected to uniform bending moment M. Assume
that lateral supports are provided at the load points.
Lb
If the laterally unbraced length Lb is less than or equal to a plastic length Lp then lateral
torsional buckling is not a problem and the beam will develop its plastic strength Mp.
Lp = 1.76 ry x
E / Fy
10
If Lb is greater than Lp then lateral torsional buckling will occur and the moment capacity of
the beam will be reduced below the plastic strength Mp as shown in Figure 10 below.
Mn = Mp
Zx Fy = Mp
Lb L p
M n M p ( M p M r )
L L
r
p
Sx (Fy 10) = Mr
Moment Capacity, M n
Mn =
Lp
2 EI y
L2b
GJ
2 ECw
L2b
Lr
Unbraced length, Lb
Lb
E I y G J
Lb
Iy Cw
Mn = moment capacity
Lb = laterally unsupported length.
Mcr = critical lateral-torsional buckling moment.
E = 29000 ksi;
G = 11,200 ksi
11
This equation is valid for ELASTIC lateral torsional buckling only (like the Euler equation).
That is it will work only as long as the cross-section is elastic and no portion of the crosssection has yielded.
As soon as any portion of the cross-section reaches the yield stress F y, the elastic lateral
torsional buckling equation cannot be used.
Lr is the unbraced length that corresponds to a lateral-torsional buckling moment
Mr = 0.70 Sx Fy.
Mr will cause yielding of the cross-section due to residual stresses.
When the unbraced length is less than Lr, then the elastic lateral torsional buckling equation
cannot be used.
When the unbraced length (Lb) is less than Lr but more than the plastic length L p, then the
lateral-torsional buckling Mn is given by the equation below:
If Lp Lb Lr,
Lb L p
then M n M p ( M p M r )
Lr L p
12
As mentioned previously, the case with uniform bending moment is worst for lateral torsional
buckling.
For cases with non-uniform bending moment, the lateral torsional buckling moment is
greater than that for the case with uniform moment.
Sometimes, if you cannot calculate or figure out Cb, then it can be conservatively
assumed as 1.0.
Cb
2.5 M max
12.5 M max
3 MA 4 MB 3 Mc
Important to note that the increased moment capacity for the non-uniform moment case
cannot possibly be more than Mp.
Therefore, if the calculated values is greater than Mp, then you have to reduce it to Mp
13
Moment Capacity, Mn
Mp
Mr
Cb = 1.5
Cb = 1.2
Cb = 1.0
Lp
Lr
Unbraced length, Lb
Steel beams are designed for the factored design loads. The moment capacity, i.e., the
factored moment strength (bMn) should be greater than the moment (Mu) caused by the
factored loads.
14
The AISC Specification gives little guidance other than a statement in Chapter L,
Serviceability Design Considerations, that deflections should be checked. Appropriate
limits for deflection can be found from the governing building code for the region.
The following values of deflection are typical maximum allowable total (service live load)
deflections.
Plastered floor construction L/360
Unplastered floor construction L/240
Unplastered roof construction L/180
In the following examples, we will assume that local buckling and lateral-torsional buckling
are not controlling limit states, i.e, the beam section is compact and laterally supported along
the length.
15
Example 5.2 Design a simply supported beam subjected to uniformly distributed dead
load of 450 lbs/ft. and a uniformly distributed live load of 550 lbs/ft. The dead load
does not include the self-weight of the beam. The length of the beam is 30 ft.
Step II. Select the lightest section from the AISC Manual design tables.
From page 3-18 of the AISC manual, select W14 x 30 made from 50 ksi steel with bMp =
177.0 kip-ft.
- OK!
Note that the serviceability design criteria controlled the design and the section
16
Example 5.3 Design the beam shown below. The unfactored dead and live loads are shown in
the Figure.
15 ft.
30 ft.
Step II. Select the lightest section from the AISC Manual design tables.
From page 3-17 of the AISC manual, select W21 x 44 made from 50 ksi steel with bMp =
358.0 kip-ft.
Self-weight = wsw = 44 lb/ft.
- OK!
18
24 ft.
(Note b = 0.9)
bMn = moment capacity = Cb x ( bMn for the case with uniform moment) bMp
Pages 3-96 to 3-139 in the AISC-LRFD manual, show the plots of bMn-Lb for the case
of uniform bending moment (Cb=1.0)
19
Therefore, in order to select a section, calculate Mu/Cb and use it with Lb to find the first
section with a solid line as shown in class.
Mu/Cb = 354.24/1.14 = 310.74 kip-ft.
Select W16 x 67 (50 ksi steel) with bMn =327 kip-ft. for Lb = 24 ft. and Cb =1.0
For the case with Cb = 1.14,
bMn = 1.14 x 327 = 373 kip-ft., which must be bMp = 491 kip-ft.
OK!
Thus, W16 x 67 made from 50 ksi steel with moment capacity equal to 373 kip-ft. for an
unsupported length of 24 ft. is the designed section.
- compact flange
- compact web
Compact section.
- OK!
This example demonstrates the method for designing beams and accounting for Cb > 1.0
20
Example 5.5
Design the bea
21