Dike Wall Design
Dike Wall Design
Dike Wall Design
B1
B1 = 400 mm GL+ 1.500M
B2 = 400 mm
L1 = 1500 mm
D= 600 mm H2
H1 = 1100 mm GL- 0.300M
H2 = 1800 mm
H1
L1 B2
3.3 FORCE DIAGRAM
GL+ 1.500M
FL1
SURCHARGE LOAD (S)
W4
GL- 0.300M W1
yL1
FL2 W3
(Soil Weight) TOE
yL2
W2
Liquid Pressure
(L) Bouyant Force (Bf)
3.4 DESIGN PARAMETER
Soil Properties
Ø= 30.0 deg., soil internal friction angle
2
gs = 9.0 kN/m , unit weight of soil (Dry)
Ka = 0.33 Active Pressure Coeficient, (1-SIN Ø)/(1+SIN Ø) ]
Material Properties
3
gc = 24.0 kN/m , unit weight of reinforced concrete
2
f'c = 24.0 N/mm , cylindrical compressive strength of concrete
2
Fy = 390.0 N/mm , yield strength of steel reinforcement
3
gw = 10.0 kN/m , unit weight of Ground Water
3
gL = 9.0 kN/m , unit weight of Liquid
2
Allowable Soil Pressure for Permanent Case, qa = 250.0 kN/m
Lever Arm
Item Force (kN) Mr (kN-m)
(m)
W1 27.8 0.200 5.57
W2 27.4 1.150 31.46
W3 31.4 0.950 29.78
W4 24.3 0.950 23.09
Bf -32.3 0.950 -30.69 <--- Bouyant Force
total = 78.6 59.2
Overturning Check
∑Mr
FOS = = 1.57 > 1.50, OK!
∑Mo
Lever Arm,
Item Force (kN) Me (kN-m)
y (m)
∑Me 58.60
e= =
∑W 110.9 (No Bouyant Force)
= 0.529 m
0.5
Vcapwall = φs*1/6*f'c *dwall