SERVICE BULLETIN

Kobelco Construction Machinery Co., Ltd.


Customer Support Department FS Group
Authorized by; Issued by;
CLASSIFICATION : IMPROVEMENT
Issue Date : September 17, 2005
Bulletin No. : S030-60-K003
Subject : Adjusting "Cold mode" procedure. (Hidden mode)
Applicable Area : ALL
Applicable Model : SK200-6E / SK230-6E

Applicable S/No. : Show below

1. Background of Information
We would like to inform you that the adjusting procedure of "Cold mode". This function is
added from "Environmental version" of SK200-6E & SK230-6E. This function corrects and
improves the machine ARM jerky operation while working in cold temperature.

2. Applicable serial No. of Manufacturers improvement


MODEL APPLICABLE S/No
SK200-6E YN08-34130 and up
SK210-6E YQ08-04773 and up
SK230-6E Running change
SK250-6E Running change

3. Information
1. Initial value depends on the HYD temperature.
2. After turn off the key switch, this function cannot be memorized for more than three hours.
3. Change to "5", when it is necessary to operate at mass excavation operation while the HYD
oil is in low temperature.

4. Adjusting procedure

1-1 Turn on key switch while pressing buzzer stop switch.


You will enter "Service Diagnosis" function, which monitor screen show No.1 display.
(Refer to display A)

1-2 Press screen change switch to display the desired screen display No. 7, which shows
Sol Valve for Power Boost. (Refer to display B)

Cluster gauge Switch location


No.1 NO.7 Screen change Buzzer stop Work mode selector
MAIN CONT. P/N SOL VALVE
"YN22E0123F1" F-1 POWER BOOST
COMP. OFF
PROGRAM VER
MEAS. OFF
VER 12.00
SWITCH OFF

Display A Display B
This bulletin is issued for information only and is not
an authorization for warranty claim submission. Working light
1
Issue Date : 2005/9/17
Bulletin No. : S030-60-K003
4. Adjusting procedure
1-3 Press "Working light switch" 3 times, keeping "Work mode selector switch" pressed, and
the "adjustment mode" appears. (Refer to Display C)

1-4 Setting procedure:


Initial adjustment mode display: (Refer to display C)
MAIN CONT. P/N
"LOW TEMP ADJ"
VER "00.00"

Press "Work mode switch"..... The adjusting value rises.


Press "Buzzer stop switch"..... The adjusting value lowers.
"00.00" (for cold mode) and "00.05" (to resume normal conflux operating condition.)

1-5 Return the diagnosis screen.


Press "Screen change switch" to confirm and data will be memorized by controller.
Display will return to the No.1 - display A condition.

No.1 NO.7 NO.1


MAIN CONT. P/N SOL VALVE MAIN CONT. P/N
"YN22E0123F1" F-1 POWER BOOST "LOW TEMP ADJ"
COMP. OFF
PROGRAM VER PROGRAM VER
MEAS. OFF
VER 12.00 VER 00.00
SWITCH OFF

Display A Display B Display C

1. The value range from (00.00 to 00.05) are the operation time Change to "00.05", when it is
which accumulated by the low pressure sensor. necessary to full spec operation
2. During ARM-IN operation, one pump is working for the first 5 when the HYD oil is low
min. temperature.
3. During ARM-OUT operation, 2 pumps operate together for
00.00 = work as cold mode
the first 5 min. However, oil flow of P2 pump is reduced by 00.05 = to resume normal conflux
the operating condition
controller.
4. After 5 min of operation, the machine resumes its normal
conflux operating condition.
5. Change the "Low Temp Adjust" setting to "5", to obtain Cluster gauge Switch location
normal 2 pump conflux condition while the HYD oil is at low
Screen change Buzzer stop Work mode selector
temperature.
6. After turn off the key switch, this function cannot be
memorized for more than 3 hours.

Working light