S000 60 031
S000 60 031
S000 60 031
1. Background
It used Hydraulic oil clogging detection control option seting for the 20t~45t Std.Machine, and other model.
Hydraulic oil filter clogging alarm system is the internal pressure of the Hyd. tank and the internal pressure of
the filter case are detected by a different pressure switch.
If switch judged that the filter is clogged. Alert on cluster gauge 『Need to replacement Filter was alarm』,
"KOMEX""GEO SCAN" is shown error code 「Z040」
2. Failler discription
When "NG" judgment is continued for 3 times, Alarm is shown on cluster gauge "Replacement of Hyd. oil filter"
If switch judged "OK", befor "NG" is cancal detaction decision.and, then it will be reset zero.
3. System Overview
・If the different pressure switch is activated by back presure, mechatro controller ignore
abnormality detection.
1 of 2 pages