Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

S000 60 031

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SERVICE BULLETIN

Kobelco Construction Machinery Co., Ltd.


Excavator Field Support Group, Q.A. Department.
Authorized by; Checked by; Issued by;
CLASSIFICATION : Information QA Dept QA Dept QA Dept
14/Sep/2017 14/Sep/2017 13/Sep/2017
Issue Date : 13th September 2017 Udo Tatsumi Oshita
Bulletin No. : S000-60-031
Subject : Hydraulic oil filter clogging alarm system
Applicable Area : KCMSA
Applicable Model : Mark 10

1. Background
It used Hydraulic oil clogging detection control option seting for the 20t~45t Std.Machine, and other model.
Hydraulic oil filter clogging alarm system is the internal pressure of the Hyd. tank and the internal pressure of
the filter case are detected by a different pressure switch.
If switch judged that the filter is clogged. Alert on cluster gauge 『Need to replacement Filter was alarm』,
"KOMEX""GEO SCAN" is shown error code 「Z040」

2. Failler discription
When "NG" judgment is continued for 3 times, Alarm is shown on cluster gauge "Replacement of Hyd. oil filter"
If switch judged "OK", befor "NG" is cancal detaction decision.and, then it will be reset zero.

3. System Overview

Equipment Control over view


Hyd. oil temp. more than 30 ℃, E/G rpm more than 1600 min -1
and control lever is neutral.

N&B return line



If the different pressure switch is activated, it judged clogging
Differenti (Eingine Key OFF Count the previous judgment as 1 time)
pressure switch

Hyd. Oil temp. 8 solenoid T It gives warning , if it detects 3 times abnormality detection.
Sensor or
PT block T

・If the different pressure switch is activated by back presure, mechatro controller ignore
abnormality detection.

1 of 2 pages