Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

De Cero A Empresario.

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

DN-60977:A

FSP-951 Series
Intelligent Plug-In Photoelectric
Smoke Detectors
Intelligent/Addressable Devices

General
The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors
are designed for both performance and aesthetics. A new modern,
sleek, contemporary design and enhanced optical sensing chamber
is engineered to sense smoke produced by a wide range of combus-
tion sources in accordance with more stringent code standards. The
FSP-951 Series detector sensitivity can be programmed in the con-
trol panel software. Sensitivity is continuously monitored and
reported to the panel. Point ID capability allows each detector’s
address to be set with rotary, decimal address switches, providing
exact detector location for selective maintenance when chamber
contamination reaches an unacceptable level. Dual electronic
thermistors add 135°F (57°C) fixed temperature thermal sensing on
the FSP-951T. The FSP-951R is a remote test capable detector for
use with DNR Series duct detector housings. FSP-951 series detec-
tors are available for both FlashScan® and CLIP applications as
designated.

Features
• New modern profile for improved aesthetics.
• Designed to meet UL268 7th Edition. FSP-951 in B300-6 Base
• Stable communication technique with noise immunity.
• Low standby current.
• FSP-951R installed in a DNR/DNRW, -20°C to 70°C (-4°F to
• Two-wire SLC connection.
158°F).
• Compatible with FlashScan® and CLIP protocol systems.
UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.),
• Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on suitable for installation in ducts.
FlashScan systems).
Relative Humidity: 10%-93% noncondensing.
• Optional remote, single-gang LED accessory.
• Dual LED design provides 360° viewing angle. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C).
• Visible bi-color LEDs blink green every time the detector is DETECTOR SPACING AND APPLICATIONS
addressed, and illuminate steady red on alarm (FlashScan sys- NOTIFIER recommends spacing detectors in compliance with NFPA
tems only). 72. In low airflow applications with smooth ceiling, space detectors
• Remote test feature from the panel. 30 feet (9.1m). For specific information regarding detector spacing,
• Walk test with address display (an address on 121 will blink the placement, and special applications refer to NFPA 72. System
detector LED: 12-[pause]-1(FlashScan systems only). Smoke Detector Application Guide, document A05-1003, is available
• Built-in functional test switch activated by external magnet. at systemsensor.com
• Built-in tamper-resistant feature. ELECTRICAL SPECIFICATIONS
• Sealed against back pressure. Voltage Range: 15-32 volts DC peak.
• Expanded color options. Standby Current (max. avg.): 200μA @ 24VDC (one communica-
• SEMS screws for wiring of the separate base. tion every five seconds with LED enabled).
• Optional relay, isolator, and sounder bases. LED Current (max.): 4.5mA @ 24 VDC (“ON”).

Specifications Installation
Sensitivity: FSP-951 series plug-in detectors use a separate base to simplify
• UL Applications: 0.5% to 4.0% per foot obscuration. installation, service, and maintenance.
• ULC Applications: 0.5% to 3.5% per foot obscuration. Mount base (all base types) on an electrical backbox which is at
Size: 2.0" (5.3 cm) high; base determines diameter. least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes,
see DN-60981.
– B300-6: 6.1" (15.6 cm) diameter.
NOTE: 1) Because of inherent supervision provided by the SLC loop,
– B501: 4" (10.2 cm) diameter. end-of-line resistors are not required. Wiring “T-taps” or branches are
For a complete list of detector bases see DN-60981. permitted for Style 4 (Class “B”) wiring. 2) When using relay or sounder
bases, consult the ISO-X(A) installation sheet I56-1380 for device limita-
Shipping weight: 3.4oz (96.4g) tions between isolator modules and isolator bases.
Operating Temperature range:
• FSP-951, 0°C to 50°C (32°F to 122°F).
• FSP-951T, 0°C to 38°C (32°F to 100°F).

DN-60977:A • 4/17/18 — Page 1 of 3


Agency Listings and Approvals B224BI-WH: White, isolator detector base.

These listings and approvals apply to the detectors specified in this B224BI-IV: Ivory isolator detector base.
document. In some cases, certain detectors or applications may not B224BIA-WH: White, isolator detector base, ULC listing.
be listed by certain approval agencies, or listing may be in process.
B224BIA-IV: Ivory isolator detector base, ULC listing.
Consult factory for latest listing status.
B200S-WH: White, Intelligent addressable sounder base capable of
• UL/ULC Listed: S911 producing sound output in high or low volume with ANSI Temporal 3,
• FM Approved ANSI Temporal 4, continuous tone, marching tone, and custom tone.
• CSFM: 7272-0028:0503 Uses FlashScan protocol.

Product Line Information B200S-IV: Ivory, Intelligent addressable sounder base capable of
producing sound output in high or low volume with ANSI Temporal 3,
NOTE: ANSI Temporal 4, continuous tone, marching tone, and custom tone.
• Detectors must be mounted to one of the Intelligent Bases listed Uses FlashScan protocol.
below. B200SA-WH: Same as B200S-WH, ULC listing.
• “A” suffix indicates ULC Listed model. B200SA-IV: Same as B200S-IV, ULC listing.
• “IV” suffix indicates FlashScan® and CLIP device. B200SCOA-WH: White, Intelligent, programmable sounder base in
English/French (required in Canada for ULC applications with SO
FSP-951: White, low-profile intelligent photoelectric sensor, FlashS- Series detector applications.
can only.
B200SCOA-IV: Ivory Intelligent, programmable sounder base in
FSP-951A: Same as FSP-951 but with ULC listing. English/French (required in Canada for ULC applications with SO
FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. Series detector applications, ULC listing.
B200S-LF-WH: White, Low Frequency Intelligent, programmable
FSP-951A-IV: Same as FSP-951-IV but with ULC listing.
sounder base. Produces a fundamental frequency of 520 Hz +/-
FSP-951T: White, same as FSP-951 but includes a built-in 135°F 10% with a square wave or its equivalent; designed to meet the
(57°C) fixed-temperature thermal device. FlashScan only. NFPA 72 sleeping space requirement.
FSP-951TA: Same as FSP-951T but with ULC listing. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/-
FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F 10% with a square wave or its equivalent; designed to meet the
(57°C) fixed-temperature thermal device. NFPA 72 sleeping space requirement.
FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing. B200SR-WH: White, Intelligent sounder base capable of producing
FSP-951R: White, low-profile intelligent photoelectric sensor, sound output with ANSI Temporal 3 or continuous tone. Intended for
remote test capable. For use with DNR/DNRW. FlashScan only. retrofit applications.
FSP-951RA: Same as FSP-951R but with ULC listing. For use with B200SR-IV: Ivory, Intelligent sounder base capable of producing
DNRA. sound output with ANSI Temporal 3 or continuous tone. Intended for
retrofit applications.
FSP-951R-IV: Ivory, low-profile intelligent photoelectric sensor,
remote test capable. For use with DNR/DNRW. B200SRA-WH: Same as B200SR-WH with, ULC listing.
B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing.
FSP-951RA-IV: Same as FSP-951R-IV but with ULC listing. For use
with DNRA. B200SR-LF-WH: White, Low Frequency Intelligent, programmable
sounder base. Produces a fundamental frequency of 520 Hz +/-
INTELLIGENT BASES 10% with a square wave or its equivalent; designed to meet the
NOTE: For details on intelligent bases, see DN-60981 NFPA 72 sleeping space requirement. Intended for retrofit applica-
tions.
B300-6: White, 6” base, standard flanged low-profile mounting base.
B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable
B300-6-IV: Ivory,6” base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/-
base. 10% with a square wave or its equivalent; designed to meet the
B300A-6: Same as B300-6, ULC listed. NFPA 72 sleeping space requirement. Intended for retrofit applica-
tions.
B300A-6-IV: Ivory, 6” standard flanged low-profile mounting base,
ULC listed. MOUNTING KITS AND ACCESSORIES
B300-6-BP: Bulk pack of B300-6, package contains 10 TR300: White, replacement flange for B210LP(A) base.
B501-WHITE: White, 4” standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A) base.
base. UL/ULC listed. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a
B501-BL: Black, 4” standard European flangeless mounting base. U.S. single-gang electrical box. For use with B501(A) and B300(A)-
UL/ULC listed. 6.
B501-IV: Ivory color, 4” standard European flangeless mounting M02-04-00: Test magnet.
base. UL/ULC listed. M02-09-00: Test magnet with telescoping handle.
B501-WHITE-BP: Bulk pack of B501-WHITE contains 10.
B224RB-WH: White, relay base.
B224RB-IV: Ivory, relay base.
B224RBA-WH: White, relay base, ULC listing.
B224RBA-IV: Ivory, relay base, ULC listing.

Page 2 of 3 — DN-60977:A • 4/17/18


©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this
document is strictly prohibited.

This document is not intended to be used for installation purposes.


We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.

For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118.
www.notifier.com

Page 3 of 3 — DN-60977:A • 4/17/18