Pile Cap Design 1
Pile Cap Design 1
DESIGN REQUIREMENTS
Reactions Allowable soil bearing stress = 300 kPa
Py = 1,800 kN Height of surcharge = 0.3 m
3
Vx = 60 kN Unit weight of surcharge = 17.3 kN/m
Vz = 10 kN Bar diameter = 16 mm
Mx = 50 kN-m Materials:
Mz = 300 kN-m fc' = 21 MPa
fy = 414 MPa
Column Dimensions: m= 23.193
bx = 0.5 m
bz = 0.5 m
Pile Dimensions
bx = 0.35 m
bz = 0.35 m
P' = 1894.032 kN
Mx' = 56 kN-m
Mz' = 336 kN-m
2
∑z = ∑z2 = m2
fmax = 574.81 kPa
Pcomp = 675.61 kPa D/C Ratio = 1.175363 (Fail!!!)
fmin = 182.81 kPa
Pten = 283.61 kPa D/C Ratio = 1.551403 (Fail!!!)
A: Punching shear
Effective depth, d = 501 mm 3 bo
bc = 1 1. Corner column 20 1.501
bo = 4.004 m 2. Edge column 30 2.502
as = 40 3. Interior column 40 4.004
B: Beam shear
B.1 Bending about the x-axis
d= 501 mm
fmax = 515.508 kPa
y1 = 0.751 m
f1 = 505.05 kPa
Beam Shear, Vu = 730.1565 kN
fVc = 650.49662 kN D/C Ratio = 1.12246