Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Chemflake Special

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Technical Data Sheet

Approved 408 1,2 408 vinyl ester ^(ValidationDate) 1

Chemflake Special

Product description
This is a glass flake reinforced vinyl ester coating. It is an ultra high build, extremely chemical resistant and fast
curing barrier coating. Can be used as primer, mid coat or finish coat in atmospheric and immersed
environments. Suitable for properly prepared carbon steel, stainless steel and concrete substrates.

Typical use
Specially designed as an internal lining for offshore, onshore and buried tanks and pipes such as chemical tanks,
flue gas ducts, cooling towers, funnels, pipes, waste water, grey water, concrete bund, pressure vessels.
Specially suitable in acidic conditions. Refer to Protective Product Resistance List. Recommended for areas
subject to extreme chemical exposure and mechanical wear and where future maintenance is challenging.
Other

Colours
red, white

Product data
Property Test/Standard Description

Solids by volume calculated 96 ± 2 %


Gloss level (GU 60 °) ISO 2813 semi gloss (35-70)
Flash point ISO 3679 Method 1 34 °C
Density calculated 1.2 kg/l
VOC-EU IED (2010/75/EU) (theoretical) 10 g/l
VOC-China GB/T 23985-2009 (tested) 23 g/l
VOC-Korea Korea Clean Air Conservation Act (tested) 57 g/l

The provided data is typical for factory produced products, subject to slight variation depending on colour.
Gloss description: According to Jotun Performance Coatings' definition.

Film thickness per coat


Typical recommended specification range

Dry film thickness 600 - 1000 μm


Wet film thickness 650 - 1080 μm
Theoretical spreading rate 1.6 - 0.9 m²/l

All vinyl ester and polyester resin systems are subject to some shrinkage during the curing process. This results
in a practical spreading rate lower than the theoretically calculated. The shrinkage depends on actual dry film
thickness applied and conditions during application.

Date of issue: 27 September 2019 Page: 1/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Chemflake Special

Surface preparation
To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any
contamination.

Surface preparation summary table

Surface preparation

Substrate Minimum Recommended

Carbon steel Sa 2½ (ISO 8501-1) with a surface Sa 2½ (ISO 8501-1) with a surface
profile Medium to Coarse G (ISO profile Medium to Coarse G (ISO
8503-2) 8503-2)
Concrete Dry abrasive blast cleaning to SSPC- Minimum 4 weeks curing. Moisture
SP 13/NACE No. 6. content maximum 5 %. Dry abrasive
blast cleaning to SSPC-SP 13/NACE
No. 6.

Application
Application methods
The product can be applied by

Spray: Standard airless spray may be used. Dedicated two component airless spray is an option.
Brush: Recommended for stripe coating and small areas, care must be taken to achieve the
specified dry film thickness.

Mixing ratio table - Additives


The steel temperature shall not be lower than the paint temperature and not more than 20 °C above the paint
temperature.
Additive volumes (ml) in 16 litres product.
Due to local regulations, local variants in pack size and filled volume may exist. Note that the amount of
additives must be adjusted accordingly.

Paint temperature
Additive 5-9 °C 10-14 °C 15-19 °C 20-24 °C 25-29 °C 30-34 °C 35-40 °C

Jotun Accelerator CO1P or


Accelerator 9802 P 400 300 300 200 200
Jotun Accelerator DMA10 or
Accelerator 9826 100 100 100 100 100
Jotun Peroxide 1, Norox KP-9,
Jotun Peroxide 11, Norox MEKP-925H or 400 400 300 300 300
Butanox M-50
Jotun Inhibitor 53 30

Date of issue: 27 September 2019 Page: 2/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Chemflake Special

Note: 5-9 °C and 10-14 °C - Applicable for selected markets only.

For other additive suppliers please consult Jotun.

WARNING:
Accelerators must never come in direct contact with peroxides.
All peroxides must be stored in a dark and cool storage room (below 25 °C), and kept away from all kind of
combustible materials. Exposure to direct sunlight must be avoided. Use only original or approved containers.
Empty containers should be washed with water and kept in separate storage/containers.
The peroxide may catch fire if exposed to sparks or to hot metal dust from grinding or other mechanical work.
The curing reaction develops heat. For leftovers of mixed paint it is recommended to fill the tin with water to
avoid excessive heat development.

Thinner/Cleaning solvent
Thinner: Styrene
Thinning max.: 5 %

Cleaning solvent: Jotun Thinner No. 17 / Jotun Thinner No. 23 / Jotun Thinner No. 27

Guiding data for airless spray


Nozzle tip (inch/1000): 27-35
Pressure at nozzle (minimum): 150 bar/2100 psi

Drying and Curing time


Substrate temperature 5 °C * 10 °C * 15 °C 23 °C 40 °C

Surface (touch) dry 6h 4h 8h 4h 2h


Walk-on-dry 6h 4h 8h 4h 2h
Dry to over coat, minimum 6h 4h 8h 4h 2h
Dry to over coat, maximum, immersed 48 h 48 h 36 h 24 h 12 h
Dried/cured for service 14 d 10 d 8d 4d 2d

For maximum overcoating intervals, refer to the Application Guide (AG) for this product.

Drying and curing times are determined under controlled temperatures and relative humidity below 85 %, and
at average of the DFT range for the product.

* Applicable for selected markets only.

Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.

Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.

Dry to over coat, minimum: The recommended shortest time before the next coat can be applied.

Dry to over coat, maximum, immersed: The longest time allowed before the next coat can be applied.

Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.

Date of issue: 27 September 2019 Page: 3/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Chemflake Special

Paint temperature 23 °C

Pot life 35 min

Heat resistance
Temperature
Continuous Peak

Dry, atmospheric 160 °C 180 °C


Immersed, sea water 85 °C 90 °C

Further resistance information can be found in Protective Product Resistance List available on Jotun's website, or
contact your local Jotun office.

Peak temperature duration max. 1 hour.


The temperatures listed relate to retention of protective properties. Aesthetic properties may suffer at these
temperatures.
Note that the coating will be resistant to various immersion temperatures depending on the specific chemical
and whether immersion is constant or intermittent. Heat resistance is influenced by the total coating system. If
used as part of a system, ensure all coatings in the system have similar heat resistance.

Product compatibility
Depending on the actual exposure of the coating system, various primers and topcoats can be used in
combination with this product. Some examples are shown below. Contact Jotun for specific system
recommendation.

Previous coat: vinyl ester


Subsequent coat: vinyl ester

Tankguard Holding Primer can be used as a temporary protection and is fully compatible with the tank coating
system.

Packaging (typical)
Volume Size of containers
(litres) (litres)

Chemflake Special 16 20

The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary
due to local regulations.

Storage
The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well
ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle
with care.

Storage temperature not to exceed 25 °C.

Date of issue: 27 September 2019 Page: 4/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Chemflake Special

Shelf life at 23 °C
Chemflake Special 4 month(s)

In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf
life, thereafter the paint quality is subject to re-inspection.

Caution
This product is for professional use only. The applicators and operators shall be trained, experienced and have
the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical
documentation. Applicators and operators shall use appropriate personal protection equipment when using this
product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit
the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing
the work.

Health and safety


Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do
not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable
cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

Colour variation
When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations
from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering.

Colour and gloss retention on topcoats/finish coats may vary depending on type of colour, exposure
environment such as temperature, UV intensity etc., and application quality. Contact your local Jotun office for
further information.

Disclaimer
The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and
practical experience. Jotun's products are considered as semi-finished goods and as such, products are often
used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product
itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves
the right to change the given data without further notice.

Users should always consult Jotun for specific guidance on the general suitability of this product for their needs
and specific application practices.

If there is any inconsistency between different language issues of this document, the English (United Kingdom)
version will prevail.

Date of issue: 27 September 2019 Page: 5/5

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com

You might also like