Transmitter supply isolator KFD2-CR-Ex1.

30300
Successor KFD2-STC4-Ex1

Connection

Input EEx ia IIC

3-wire transmitter ?
J

Hazardous area
• 1-channel
1+ 2- 3
• Input EEx ia IIC; U0 = 26 V
?
• 24 V DC supply voltage 2-wire transmitter J
• Output: allowable load max. 1 kΩ
• EMC acc. to NAMUR NE 21 1+ 3

Current source
Input 0/4 mA ... 20 mA
Output 0/4 mA ... 20 mA 2- 3

KFD2-CR-Ex1.30300
1+ 2- 3

Function

The devices are suited for the


connection of 2- and 3-wire + -
transmitters. They may also be used as

Safe area
repeaters for 0/4 mA ... 20 mA signals
(current source).
For a supply voltage that is > DC 20 V ,
the open circuit voltage at the terminals
is DC 25 V and is greater than DC 18 V
with a current of 20 mA .
2-wire transmitters are connected to
terminals 1 and 3. The input for the
signal current is terminal 3. The + -
minimum available voltage is 13.6 V at
9- 7- 8+ 11+ 12-
20 mA.
Output Power supply Power Rail
The power supply is provided to
terminals 1+ and 2- for 3-wire
transmitters. With a 25 mA supply
current, the voltage between the Composition
terminals is about 16.5 V.
Power supplies, whose currents do
not have to be transferred to the
hazardous area, are connected to
terminals 2 and 3. Terminal 1+ remains
free and the sources are not supplied
with power.
Release date 2006-03-01 15:08 Date of issue 2006-03-01 116314_ENG.xml

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 1
Technical data KFD2-CR-Ex1.30300

Supply
Connection Power Rail or terminals 11+, 12-
Rated voltage 20 ... 35 V DC
Ripple < 20 µArms
Power loss 1.3 W
Power consumption approx. 1.8 W
Input
Connection terminals 1+, 2+, 3-
Input resistance approx. 220 Ω terminals 2-, 3
Available voltage approx. 16.5 V at 25 mA terminals 1+, 2-
≥ 13.6 V at 20 mA terminals 1+, 3-
Output
Connection terminals 7-, 8+, 9-
Load ≤ 1 kΩ
Output signal 0 ... 20 mA
Ripple ≤ 20 µA ss
Available voltage 20 V DC
Transfer characteristics
Deviation
After calibration ≤ ± 10 µA incl. non-linearity and load fluctuations
Influence of ambient temperature ≤ ± 0.2 µA / K in the range of 273 K ... 333 K;
± 1.0 µA in the range of 253 K ... 273 K
Rise time approx. 50 µs; load = 250 Ω
De-energized delay approx. 50 µs; load = 250 Ω
Electrical isolation
Output/power supply function insulation acc. to EN 50178, rated insulation voltage 253 Veff
Directive conformity
Electromagnetic compatibility
Directive 89/336/EC EN 61326, EN 50081-2
Conformity
Electromagnetic compatibility EN 50081-2, EN 50082-2, NE 21, IEC 801-4, 801-5 and 801-6, intensity level 3
Protection degree IEC 60529
Ambient conditions
Ambient temperature -20 ... 60 °C (253 ... 333 K)
Mechanical specifications
Protection degree IP20
Mass approx. 100 g
Dimensions 20 x 107 x 115 mm (0.8 x 4.2 x 4.5 in)
Data for application in conjunction
with hazardous areas
EC-Type Examination Certificate BAS 00 ATEX 7164 , for additional certificates see www.pepperl-fuchs.com
Group, category, type of protection ¬ II (1) G D [EEx ia] IIC (-20 °C ≤ Ta ≤ 60 °C) [circuit(s) in zone 0/1/2]
Equipment terminals 1, 2, 3 terminals 1, 2 terminals 1, 3 terminals 3, 2
Input EEx ia IIC
Voltage U0 26 V 26 V 26 V 4.3 V
Current I0 115 mA 93 mA 56 mA 22 mA
Power P0 0.624 W 0.6 W 0.36 W 0.024 W
Release date 2006-03-01 15:08 Date of issue 2006-03-01 116314_ENG.xml

Supply
Safety maximum voltage Um 250 V eff (Attention! The rated voltage can be lower.)
Type of protection [EEx ia]
Explosion group IIA IIB IIC
External capacitance 2.6 µF 0.77 µF 0.099 µF
External inductance 23.98 mH 12 mH 2.82 mH
Output
Safety maximum voltage Um 250 V eff (Attention! The rated voltage can be lower.)
Statement of conformity TÜV 02 ATEX 1797 X , observe statement of conformity
Group, category, type of protection, ¬ II 3 G EEx nA II T4 [device in zone 2]
temperature classification
Electrical isolation
Input/output safe electrical isolation acc. to EN 50020, voltage peak value 375 V
Input/power supply safe electrical isolation acc. to EN 50020, voltage peak value 375 V
Directive conformity
Directive 94/9 EC EN 50014, EN 50020, EN 50021
Entity parameter
Certification number 4Z6A5.AX

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 2
Technical data KFD2-CR-Ex1.30300

FM control drawing No. 116-0129


Suitable for installation in division 2 yes
Input I terminals 1, 3
Voltage VOC 28 V
Current It 93 mA
Explosion group A&B C&E D, F&G
Max. external capacitance Ca 0.14 µF 0.43 µF 1.14 µF
Max. external inductance La 4.18 mH 16.83 mH 34.21 mH
Input II terminals 2, 3
Voltage VOC 4.4 V
Current ISC 22.2 mA
Explosion group A&B C&E D, F&G
Max. external capacitance Ca 1000 µF 3000 µF 8000 µF
Max. external inductance La 67.82 mH 239 mH 597 mH
Input III terminals 1, 2, 3
Voltage Vt 29 V
Current It 115 mA
Explosion group A&B C&E D, F&G
Max. external capacitance Ca 0.13 µF 0.39 µF 1.05 µF
Max. external inductance La 2.68 mH 11.46 mH 22.41 mH
Safety parameter
CSA control drawing LR 65756-13
Control drawing No. 116-0132
Input I terminals 1, 2
Safety parameter 28 V / 300 Ω
Input II terminals 2, 3
Safety parameter 4.1 V / 200 Ω
Input III terminals 1, 2, 3
Voltage VOC 28 V
Current ISC 113 mA
Explosion group A&B C&E D, F&G
Max. external capacitance Ca 0.14 µF 0.42 µF 1.14 µF
Max. external inductance La 2.7 mH 11.8 mH 23.2 mH

Supplementary information
EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity and instructions have to be observed. For
information see www.pepperl-fuchs.com.

Accessories

Power Rail PR-03


Power Rail UPR-03
Power feed module KFD2-EB2...
Using Power Rail PR-03 or UPR-03 the devices are supplied with 24 V DC by means of the power feed modules. If no Power
Rails are used, power supply of the individual devices is possible directly via their device terminals.
Release date 2006-03-01 15:08 Date of issue 2006-03-01 116314_ENG.xml

Each power feed module is used for fusing and monitoring groups with up to 100 individual devices. The Power Rail PR-03 is
an inset component for the DIN rail. The Power Rail UPR-03 is a complete unit consisting of the electrical inset and an aluminium
profile rail 35 mm x 15 mm x 2000 mm. To make electrical contact, the devices are simply engaged.
The Power Rail must not be fed via the device terminals of the individual devices!

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com 3

You might also like