Renderoc LA55
Renderoc LA55
Renderoc LA55
Uses Properties
The high fluid nature of Renderoc LA55 obviates the need The following typical results were obtained at a water to
for compaction and vibration and are most suitable for: powder ratio of 0.133 and temperature of 20ºC.
Test method Typical result
Repair zones with restricted access or congested
Compressive strength : > 25 N/mm2 at 3 days
reinforcement
(BS 1881 Pt.116 )
1
> 45 N/mm2 at 7 days
Reinstatement of large, strctural sections of concrete > 55 N/mm2 at 28 days
Description
Specification
Refer to your local Fosroc office for the method statement Shelf life
specifying surface preparation, priming, mixing, application
Renderoc LA55 has a shelf life of 12 months; if kept in a dry
and cleaning methods.
environment, in its original, unopened packing. If stored in
conditions of high humidity and/or temperature, the shelf life
Estimating
of Renderoc LA55 will be reduced to as little as 4 months.
Supply
Renderoc LA55 : 25kg bags Precautions
Actual coverage rate is approximate, and will be wholly Renderoc LA55 contains cement powders which, when
dependent upon the general substrate condition. It is mixed with water or upon becoming damp, release alkalis
recommended, therefore, that site trials over a typical area which can be harmful to the skin.
are conducted to determine the likely usage/coverage rates
During use, avoid inhalation of the dust and contact with the
for a particular substrate.
Renderoc LA55 : 12 litres/25kg bag skin or eyes. Wear suitable protective clothing - eye protec-
tion, gloves and respiratory equipment (particularly in
confined spaces).
Limitations
The use of barrier creams to provide additional skin protec-
- Renderoc LA55 should not be used when the ambient
tion is also advised. In case of contact with the skin, rinse
temperature is below 5°C and falling.
with plenty of clean water, then cleanse thoroughly with soap
- Renderoc LA55 should not be part mixed. and water.
- Renderoc LA55 should not be exposed to running water In case of contact with eyes, rinse immediately with plenty of
either during application or prior to final set. clean water and seek medical advice. If swallowed seek
medical attention immediately - do not induce vomiting.
- Water ponding is not recommended for curing.
Fire
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the Supply of
Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s responsibility to obtain the latest version.
Head Office
telephone: (+9714) 2039699 fax: (+9714) 2859649 email: agf@fosroc.com
Al Gurg Fosroc LLC
Regional offices
Post Box 657, Dubai Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: abudhabi@fosroc.com
Bahrain, YBA Kanoo telephone: 17738200 fax: 17732828 email: bahrain@fosroc.com
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: kuwait@fosroc.com
Oman, Al Amana telephone: 24815080 fax: 24817554 email: oman@fosroc.com
www.fosroc.com