Technical Data: 1300KW / 1625KVA 1100KW / 1375KVA

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

www.Alborzgenerator.

com
Bargh Afshan Alborz

Technical Data
BA.A-CK1600 Diesel Generating Set
1300KW / 1625KVA Standby Power(50Hz)
1100KW / 1375KVA Prime Power(50Hz)

General Features:

 Engine (Cummins KTA50-G8)


 Radiator 40C max, fans are driven by
belt, with safety guard
 24V charge alternator
 Alternator: single bearing alternator IP23,
insulation class H/H
 Absorber
 Dry type air filter, double fuel filter, oil filter,
coolant filter
 Main line circuit breaker
 Permanent Magnet Generator(PMG)
 Standard control panel
 Two12V batteries, rack and cable
 Ripple flex exhaust pipe, exhaust siphon,
 flange, muffler
 User manual

Generator Ratings
Prime Standby Standby P.F Phase HZ Voltage
Ratings Ratings Amps (COS¢)
(KW/KVA) (KW/KVA)
1100/1375 1300/1625 2132 0.8 3 50 440/254
1100/1375 1300/1625 2260 0.8 3 50 415/240
1100/1375 1300/1625 2345 0.8 3 50 400/230
1100/1375 1300/1625 2469 0.8 3 50 380/220

Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load
application, in accordance with GB/T2820-97(eqv ISO8528); A 10% overload capability is available for a
period of 1 hour within a 12-hour period of operation.

Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the
duration of a utility power interruption. No overload, utility parallel or negotiated outage
operation capability is available at this rating.

Sales Promises

Bargh afshan alborz provides a full line of brand new and high quality products. Each and every unit is
strictly factory tested.
Warranty is according to our standard conditions: a, 15 months, counted on the day Bargh afshan alborz sold to
the first buyer; b, One year after installation; c, 1000 running hours (accumulated); subject to the earlier one.
Service and parts are available from Bargh afshan alborz or distributors in your location.

1/5Specifications may change without notice


www.Alborzgenerator.com
Bargh Afshan Alborz

Technical Data
BA.A-CK1600 Diesel Generating Set
ENGINE DATA
Manufacturer / Model: Cummins KTA50-G8, 4-cycle
Air Intake System: Turbo,Air/Water cooling
Fuel System: PT type fuel pump, EFC
Cylinder Arrangement: 16 in V
Displacement: 50.3L
Bore and Stroke: 159*159(mm)
Compression Ratio: 14.9
Rated RPM: 1500rpm
Max. Standby Power at Rated RPM: 1300KW/1766HP
Governor Type: Electronic
Exhaust System
Exhaust Gas Flow: 4350L/s
Exhaust Temperature: 510℃
Max Back Pressure: 6.7kPa
Air Intake System
Max Intake Restriction: 6.23kPa
Consumption: 1655L/s
Air Flow: 44000L/s
Fuel System
100%( Prime Power) Load: 289 L/h
75%(Prime Power) Load:
50%(Prime Power) Load::
Oil System
Total Oil Capacity: 204L
Oil Consumption: ≤4g/kwh
Engine Oil Tank Capacity: 178L
Oil Pressure at Rated RPM: 345-483kPa
Cooling System
Total Coolant Capacity: 199L
Thermostat: 82-93℃
Max Water Temperature: 104℃

2/5Specifications may change without notice


www.Alborzgenerator.com
Bargh Afshan Alborz

Technical Data
BA.A-CK1600 Diesel Generating Set
ALTERNATOR SPECIFICATION
GENERAL DATA
Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards.
Alternator Data
Number of Phase: 3
Connecting Type: 3 Phase and 4 Wires, “Y” type connecting
Number of Bearing: 1
Power Factor: 0.8
Protection Grade: IP23
Altitude: ≤1000m
Exciter Type: Brushless, self-exciting
Insulation Class, Temperature Rise: H/H
Telephone Influence Factor (TIF): <50
THF: <2%
Voltage Regulation, Steady State: ≤±1%
Alternator Capacity: 1600KVA
Alternator Efficiencies: 95.7%
Air Cooling Flow: 2.69m3/s
GENERATING SET DATA
Voltage Regulation: ≥±5%
Voltage Regulation, Stead State: ≤±1%
Sudden Voltage Warp (100% Sudden Reduce): ≤+25%
Sudden Voltage Warp (Sudden Increase): ≤-20%
Voltage Stable Time (100% Sudden Reduce): ≤6S
Voltage Stable Time (Sudden Increase) ≤6S
Frequency Regulation, Stead State: ≤5%
Frequency Waving: ≤0.5%
Sudden Frequency Warp (100% Sudden Reduce): ≤+12%
Sudden Frequency Warp (Sudden Increase): ≤-10%
Frequency Recovery Time (100% Sudden Reduce): ≤5S
Frequency Recovery Time (Sudden Increase): ≤5S

3/5Specifications may change without notice


www.Alborzgenerator.com
Bargh Afshan Alborz

Technical Data

BA.A-CK1600 Diesel Generating Set


Options
Engine Fuel System Control System
Heater 2KW & 4KW Daily Fuel Tank Auto Control Panel
Battery Charger 3.5A & 7A Base Fuel Tank Remote Control Panel
Water Separator Auto Transfer Switch (ATS)
Fuel Level Sensor Paralleling System
Alternator Others Data
Anti Condensation Heater Rainproof Type Engine Parts Drawing List
Drop CT(For Paralleling) Soundproof Type Spare Parts
Container Type
Dimension & Weight
Standard Configuration With Base Fuel Tank Soundproof Type
(Open Type)
Overall Size:5820(mm) Overall Size: Standard 40’ft high
×2200(mm)×2800(mm) container
Weight: 10600kg Weight: 32000kg

4/5Specifications may change without notice


www.Alborzgenerator.com
Bargh Afshan Alborz

Technical Data
BA.A-CK1600 Diesel Generating Set
Standard Control Panel
Auto Module Control Panel

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel
adopts auto module control system, with large LCD display to show the menu.

Features: MRS10-can receive remote output signal from ATS and realize auto start and stop of generators.

MRS16-can realize all functions of MRS10, add RS232 interface which can communicate with PC to realize
remote operation.

AMF25-Auto Mains Failure controller, can realize all functions of MRS16, furthermore can detect ATS and
control directly.

Auto Parallel Control Panel

Automatic Parallel Control Panel This new automatic parallel system adopts intelligent
modules, inserted and folded installed, no need the peripheral relay and logic circuit .

The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is
very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to